Construction of Forest Hut at Panchanpathri Forest Range D.H Pora, Special Forest Division, Kulgam B.W.O Electric work
2026_PWDJK_302223_1
NIT No.277/2025-26 Dt/03/02/2026
Open Tender
Electrical Works
Percentage
DH Pora Kulgan
Please refer Tender documents.
4 documents required · 4 mandatory
₹200
Yes
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹3,883
4 Feb 2026
4 Feb 2026
14 Feb 2026
4 Feb 2026
13 Feb 2026
4 Feb 2026
Wiring for lighting points/fan points/exhaust fan points/call bell points with 2x1.5 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit, with 240V 6A modular switch ,modular plate, suitable GI box and earthing the point with 1.5 sq mm FRLS PVC insulated copper conductor single core cable, etc. as required. (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit.
Supply, Installation, Testing and Commissioning of 15W/+ LED recessed/mounted (round or square) Down lighters having aluminum body, minimum 100lm/w, average life 50000 hours, Operating temperature -10°C to +45°C.Certification:- LM79 & LM80 test report should be from govt approved In-house NABL lab/ government of India.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending department. (Havells/ Philips/ Crompton/ Jaguar/Wipro/ eq. make to be approved by EIC).
Supply, Installation, Testing and Commissioning of 1200 mm sweep ceiling fan with 3 No. Aluminium blades, reqd. long down rod, 2nos. canopies,safety cable, shackle kit, Power Factor not less than 0.9, 45-54W, Air flow 7200-7500cfm, RPM>340, Service Value including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, and including iron hook complete job.The job includes replacement warranty of fixture if damaged/ burnt out what so ever reason for a period of two years reckoned from the date of successful commissioning/ handing over of site to the intending departm (USHA/Havells/Crompton/Phillips/bajaj/ eq. make) as directed by engineer incharge.
Supply and fixing of 6A/250 V AC fan dimmer step type 2 module with cover plate Anchor Roma plus/SSK NV/ equivalent make as directed by engineer incharge.
Supply, Installation, Testing and Comm. Of 200/250mm sweep exhaust fan Shutter type of havell /Bajaj/ Crompton/equivalent make as directed by engineer incharge,Air Flow capacity >850cmph, 35-50Watts,Noise level 44db, 1200 rpm,water resistant, including making of space in wall/ window as per site requirement and necessary connections.The job includes replacement warranty of fixture if damaged/burn out what so ever reason for a period of two years reckoned from the date of sucessful commissioning / handing over of site to the intending department.(To be got approved before installation from EIC)
Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A modular socket outlet and 15/16 A modular switch connections etc. as required.( Anchor roma plus/Legrand Mylinc /SSK/Schneider Zencelo /Crabtree athena / eq. make to be approved by EIC).
Supplying and fixing of GI box along with modular base and cover plate for modular sockets, switches in recess etc as required 6 module (200mm x 75mm)
Supplying and fixing of 5pin 5-10A socket and 5-10A switch on existing modular plate, incl connections etc as required. (Havells/SSK/Anchor/ABB/Schneider/ eq. make to be approved by EIC)
Wiring for light/power plug points (15/16A heating points) with 2x4 sq mm FRLS PVC insulated flexible stranded copper conductor wires in recessed or surface medium class PVC conduit along with 1x4 sq. mm FRLS PVC insulated copper conductor single core cable for earthing, etc. as required.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) including the cost of conduit.
Wiring for 5-10A socket out lets for computer with 2X2.5 sq. mm FRLS PVC insulated copper conductor (Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ) as directed by engineer incharge.) single core cable in surface/recessed medium class PVC conduit, alongwith 1 No. 2.5 sq. mm FRLS PVC insulated copper conductor single core cable for earthing etc. as required including the cost of conduit.
Supplying and fixing of indicators on existing modular plate and switch box , incl. connections, etc. as required. (Havells/ SSK/ Anchor/ ABB/Schneider or equivalent).
Supplying and fixing modular blanking plate on the existing modular plate switch box excluding modular plate as recquired.
Supply and fixing of 6 way (4+18), Double door surface/ recess mounting, Horizontal type,three pole and neutral, sheet steel, MCB distribution board ,415V, dust protected, duly powder painted, inclusive of tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs, excluding cost of MCBs and Incomer. (Havells/Legrand/SSK/Schnider/ABB/ eq. make to be approved by EIC)
Supply, installation, testing and commissloning of 5-32A single pole rating 240/415V, 10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/ eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 32A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/L&T/ABB/ eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 40A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/ eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 63A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/ eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 100A DP rating 240/415V,10 KA "C" curve MCB of Legrand/ Havells/ L&T/ABB/ eq. make to be approved by EIC suitable for inductive load in the MCB distribution board complete with necessary connections.
Supply, installation, testing and commissioning of 100A 4Pole Connector inside PVC enclosure of Legrand/ Havells/ L&T/ABB complete with necessary connections.
Wiring for Circuit/Sub mains along with earth wire in FRLS PVC insulated 660/1100 volt grade flexible stranded copper conductor wires in recessed or surface conduiting system, including the cost of conduit.(Havells/ Polycab/ Anchor/ SSK/KEI/RR or equivalent make ).
2x 2.5 sq mm + 1x 2.5 sq mm Lighting circuit
2x10 sq mm
Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required.Complete Job.
Providing and laying earth connection from earth electrode with 8 mm dia copper wire in 15 mm dia G.l. pipe from earth electrode including connection with copper thimble excavation and re-filling as required.
Supply, laying, connecting and commissioning of 25 sq mm 2 core XLPE/ PVC Insulated and steel armored 1.1 KV grade Aluminum LT cable for Service line, incl. cost of required al. thimbles duly crimped, including saddles Complete Job. (Over head/ under ground).(Havells/Polycab/SSK/ eq. make to be approved by EIC)
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 2.05 MB
BOQ_980664.xls
BOQ • 0.26 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .