| 1 | L1₹1.5 CrAccepted-AOC | ₹1.5 Cr | L1 | Accepted-AOC Lowest |
| 2 | L2₹1.5 Cr+₹60,882 (0.40%)Rejected-Finance DOOR NO 3 154 B MUTHYAMAMBA COLONY NEAR GOVT HIGH SCHOOL VEPAGUNTA VISAKHAPATNAM 530047 | VISAKHAPATANAM | ANDHRA PRADESH | 530047 | ₹1.5 Cr+₹60,882 (0.40%) | L2 | Rejected-Finance Not lowest |
| 3 | L3₹1.6 Cr+₹4.5 L (2.93%)Rejected-Finance 50 1 56 13 SURYA TOWERS ASR NAGAR SEETHAMMADHARA VISAKHAPATNAM 530 013 | VISAKHAPATANAM | ANDHRA PRADESH | 530013 | ₹1.6 Cr+₹4.5 L (2.93%) | L3 | Rejected-Finance Not lowest |
| 4 | L4₹1.6 Cr+₹9.0 L (5.85%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | VISAKHAPATANAM | ANDHRA PRADESH | 530001 | ₹1.6 Cr+₹9.0 L (5.85%) | L4 | Rejected-Finance Not lowest |
| 5 | L5₹1.7 Cr+₹14.2 L (9.28%)Rejected-Finance ASHOKA PARK PALLAVA PARK BVT INS VISHWAKARMA INDIAN NAVY OF GE ND VISAKHAPATNAM | ₹1.7 Cr+₹14.2 L (9.28%) | L5 | Rejected-Finance Not lowest |
Tender Value
₹1.8 Cr
EMD Value
₹2.5 L
Closing Date
8 Oct 2024, 6:00 pmClosed
CHIEF ENGINEER RND SECUNDERABAD
CHIEF ENGINEER RND SECUNDERABAD PICKET OPP JUBILEE BUS STATION SECUNDERABAD 500003
PROVISION OF FAMILY WELFARE CENTRE AT NSTL VISAKHAPATNAM
2024_MES_663747_2
87156
Open Tender
Civil Works
Lump-sum
365 days
NSTL VISAKHAPATNAM
Class B
Category a(i)
7 documents required · 7 mandatory
₹1,000
Yes
ASST GARRISON ENGINEER I RND NSTL VISAKHAPATNAM
₹2.5 L
Yes
3 Dec 2024
17 Sept 2024
15 Oct 2024
17 Sept 2024
8 Oct 2024
1 Oct 2024
Amount
Schedule 'A' Part-I (BUILDINGS AND STRUCTURES) This Schedule (contains under mentioned Sl item Nos. 1.01 & 1.02) is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6.
Lumpsum price worked out by the contractor for RCC framed construction with PCC block masonry panels complete including internal services for non-residential building upto 3.60 mtr Height family welfare centre building complete all as shown on drawings and as specified.
Lumpsum price worked out by the contractor for RCC framed construction with PCC block masonry panels complete including internal services for non-residential building upto 3.20 mtr for car parking complete all as shown on drawings and as specified.
Lump sum price worked out by the Contractor for “EARTHWORK EXCAVATION, SITE CLEARANCE AND DEVELOPMENT" as listed in Schedule ‘A’ Part - II representing _________ % _____________________ percent Above / Below the lump sum price of `4,58,246.68 inserted by the MES in Schedule ‘A’ Part - II
Lump sum price worked out by the Contractor for “INTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - III representing _______________ % ___________________ percent Above / Below the lump sum price of `3,25,834.00 inserted by the MES in Schedule ‘A’ Part - III
Lump sum price worked out by the Contractor for “INTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - IV representing __________ % ____________ percent Above / Below the lump sum price of ₹50,964.55 inserted by the MES in Schedule ‘A’ Part - IV
Lump sum price worked out by the Contractor for "AIR CONDITIONING & REFRIGERATOR” as listed in Schedule ‘A’ Part - V representing _______ % __________________ percent Above / Below the lump sum price of `0.00 inserted by the MES in Schedule ‘A’ Part - V
Lump sum price worked out by the Contractor for “ROADS / HARDSTANDING / CULVERT / PATH” as listed in Schedule ‘A’ Part - VI representing ____________ % ________________________ percent Above / Below the lump sum price of `13,83,912.03 inserted by the MES in Schedule ‘A’ Part - VI
Lump sum price worked out by the Contractor for “EXTERNAL WATER SUPPLY” as listed in Schedule ‘A’ Part - VII representing ________________ % _______________________________ percent Above / Below the lump sum price of `82,377.20 inserted by the MES in Schedule ‘A’ Part - VII
Lump sum price worked out by the Contractor for “EXTERNAL ELECTRIFICATION” as listed in Schedule ‘A’ Part - VIII representing ____________ % ___________________________ percent Above / Below the lump sum price of ₹8,52,306.40 inserted by the MES in Schedule ‘A’ Part - VIII
Lump sum price worked out by the Contractor for “SEWAGE DISPOSAL” as listed in Schedule ‘A’ Part - IX representing _____________ % ____________________ percent Above / Below the lump sum price of `2,25,810.00 inserted by the MES in Schedule ‘A’ Part - IX
Lump sum price worked out by the Contractor for “AREA DRAINAGE” as listed in Schedule ‘A’ Part - X representing _______________ % ____________________ percent Above / Below the lump sum price of `2,22,936.98 inserted by the MES in Schedule ‘A’ Part - X
Lump sum price worked out by the Contractor for “COMPOUND WALL” as listed in Schedule ‘A’ Part - XI representing _______________ % ____________________ percent Above / Below the lump sum price of `29,98,349.30 inserted by the MES in Schedule ‘A’ Part - XI
Lump sum price worked out by the Contractor for “RAIN WATER HARVESTING” as listed in Schedule ‘A’ Part - XII representing _____________ % _________________ percent Above / Below the lump sum price of `2,31,864.15 inserted by the MES in Schedule ‘A’ Part - XII
This Schedule is not prepriced by MES and the prepriced rate indicated in Col - 5 as ₹0.00 indicates this fact only. The tenderer is required to quote their rates in Column 6. This Schedule constitutes Sl. Item Nos. 14.00 to 34.00.
AIR CONDITIONING & REFRIGERATOR Supply, install & testing air cooled split unit air conditioners electric driven single phase, copper tube condensor coil of capacity of 1.5 TR BEE 5 star rated complete with cordless remote control complete all as specified and directed. Make: Blue star Model No. IC518NU and technically equivalent in Hitachi / Carrier / Voltas.
S&F, voltage stabilizer for automatic operation, single phase naturally air cooled indoor type and designed for input variation between 170V to 250V with output voltage stabilized at 230V with accuracy of + 2.5% and capacity 4 KVA complete all as specified and directed. Make: V GUARD Model No. VEW 400 PLUS.
S&F, refrigerator electric driven (single phase) capacity 360 litres, BEE 5 star rated complete all as specified and directed. Make: LG Cat Part No. Ebony Sheen, GL-T382VESX.
Supply, install, testing & commissioning of water cooler BEE 5 star rated partly stainless steel, electric driven single phase having approx storage capacity 80 ltrs and nominal cooling capacity 60 ltrs/hrs with inbuilt UV filter complete all as specified and directed. Make: Blue star Cat Part No. SWCSDLX6080UV and technically equivalent in Voltas.
ROADS / HARDSTANDING / CULVERT / PATH S&F, Poly carbonate road convex mirror outdoor type 1000mm dia made out fibre alongwith bracket and fixing the MS pipe embeded in PCC 1:2:4 type B1 using 20mm graded stone aggregate concrete complete all as specified and directed. Make: Poly carbonate convex mirror is DARK EYE / Frontier polymers Pvt Ltd or equivalent as approved by GE.
EXTERNAL WATER SUPPLY M&L for cutting in position existing 50 mm bore GI water pipe and tapping in position for taking the branch connection of size 40 mm, supply & installation of suitable GI Tee including all ends, suitable size of reducer, flanges complete as required as per site condition nuts & bolts, washers etc for tapping out branch connection including all as directed by Engineer-in-Charge.
M&L for boring of holes under road, pavement, hard standing by trenchless technology using ultra sounding technique and necessary machine including HDPE pipe of 150 mm dia suitable for 0.4 mpa working pressure complete all as specified and directed.
EXTERNAL ELECTRIFICATION S&F, pole mounted PVC junction box one piece moulded SMS base and SMC door fixed with hinges on left side of size 280 x 130 x 95 mm inside of off white colour, Make: Sintex including one No SP MCB of 6 Amp capacity and suitable neutral link and necessary fixing arrangement complete all as specified and directed.
Cutting trench of width 30cm and depth n.exc. 60cm through road / hard standing for laying cable through GI pipe and returning, filling in including spreading leveling watering and well ramming in layers not exc 25cm after laying the cable complete all as specified and directed.
M&L for re-routing of 11KV HT cable in service this includes taking out HT cable from site by carefully excavation and removal from ground with out any damage to existing cable and relaying of same cable as after providing straight through joint as per IS standard including required excavation, covering of cable with sand filling and covered by PCC HT cable cover complete all as specified and directed by Engineer-in-Charge.
M&L for carefully shifting of existing 5 way 11 KV RMU with help of hydra by disconnecting the HT supply & refixing the same 5 way 11 KV RMU at suitable location alongwith suitable PCC foundation for RMU & connecting all the HT 11 KV electrical cables, testing after installation complete all as specified & directed by Engineer-in-Charge.
INTERNAL WATER SUPPLY S&F in 15mm dia Pillar taps, cast copper alloy with long neck, chromium plated fancy type with aerator, screwed down high pressure with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S&F in cast copper alloy, chromium plated 2 way bib cock 15mm dia with crutch handle with wall flange complete all as specified and directed.
S&F in CP push taps for urinals with connecting CP pipes complete all as specified and directed.
S&F, brass chromium plated soap dish complete all as specified and directed.
INTERNAL ELECTRIFICATION S&F, (4FT) 20 W LED fitting batten for surface and wall conduit mounting high transmissitivity diffuser high lumen output PF > 0.98, thd < 10 % wall mounted type fitting with LED tube rod, complete all as specified and directed by Engineer-in-Charge. Make: Bajaj Cat No. BCLAB20WLEDPS.
S&F, LED luminaire 600 mm x 600 mm (2ft x 2ft), 36 watt, 220 V AC surface mounted type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size complete all as specified and directed by Engineer-in-Charge. Make: Bajaj BZSSQL 36L LED WH GX.
S&F, LED light fitting mirror type with high out put diffuser 2 feet, 10 watt 220 V AC decorative type with driver holder and LED lamp including connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed. Make: Bajaj BCLSB 10 W WH.
Supply, fixing & installation of 5 star ceiling fans AC single phase 230/240 V of size 1200 mm sweep with blades complete including connecting up with 3 core cord flexible from ceiling rose to ceiling fan etc, complete all as specified and directed by Engineer-in-Charge. Make: Orient Electric smart saver 50.
Supply, fixing & installation of exhaust fans AC single phase 230/240 V of size 250 mm sweep with louvres complete including connecting up with 3 core cord flexible from ceiling rose to exhaust fan etc, complete all as specified and directed by Engineer-in-Charge. Make: Orient Electric.
S&F, LED building security light 24 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP-66 protection with impact and corrosion resistant complete with driver and lamp complete all as specified and directed by Engineer-in-Charge. Make: Bajaj ENXT P 36L WH PO PC SD MT.
SRI ADITYA CONSTRUCTIONS (BID ID -3132917)
SAI KRISHNA ASSOCIATES (BID ID -3128588)
RAGHU RAMA PANDA (BID ID -3132283)
SREE CONSTRUCTIONS (BID ID -3131500)
MURALI KRISHNA ASSOCIATES (BID ID -3132553)
MERIDIAN CONSTRUCTIONS PRIVATE LIMITED (BID ID -3133031)
P Govinda Reddy Infrastructure (BID ID -3132589)
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .