Loading…
Loading…
Tender Value
₹65.6 L
EMD Value
₹1.3 L
Closing Date
1 Oct 2026, 3:00 pm
No
No
Single Packet System
Normal Tender
No
Not Applicable
Lowest to Highest
60 days
Expenditure
Capital (Works)
Above/Below/Par
ELEC CTA
17 conditions · 6 needing a document upload
The tenderer must have successfully completed or substantially completed any one of the following categories of work(s) during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of SGCC, with prior approval of Chief Engineer in writing. Three similar works each costing not less than the amount equal to 30% of advertised value of the tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of the tender, OR One similar work costing not less than the amount equal to 60% of advertised value of the tender In case of tenders for composite works (e.g. works involving more than one distinct component, such as Civil Engineering works, S&T works, Electrical works, OHE works etc. and in the case of major bridges - substructure, superstructure etc.), tenderer must have successfully completed any of the following during last 07 (seven) years, ending last day of month previous to the one in which tender is invited: Three similar works each costing not less than the amount equal to 30% of advertised value of each component of tender, OR Two similar works each costing not less than the amount equal to 40% of advertised value of each component of tender, OR One similar work each costing not less than the amount equal to 60% of advertised value of each component of tender. Separate completed works of minimum required values shall also be considered for fulfillment of technical eligibility criteria for different components. In such cases, what constitutes a component in a composite work shall be clearly predefined with estimated tender cost of it, as part of the tender documents without any ambiguity. To evaluate the technical eligibility of tenderer, only components of work as stipulated in tender documents for evaluation of technical eligibility, shall be considered. The scope of work covered in other remaining components shall be either executed by tenderer himself if he has work experience as mentioned in clause 7 of the Standard General Conditions of Contractor through subcontractor fulfilling the requirements as per clause 7 of the Standard General Conditions of Contract or jointly i.e., partly himself and remaining through subcontractor, with prior approval of Chief Engineer in writing. However, if required in tender documents by way of Special Conditions, a formal agreement duly notarized, legally enforceable in the court of law, shall be executed by the main contractor with the subcontractor for the component(s) of work proposed to be executed by the subcontractor(s), and shall be submitted along with the offer for considering subletting of that scope of work towards fulfilment of technical eligibility. Such subcontractor must fulfill technical eligibility criteria as follows. The subcontractor shall have successfully completed at least one work similar to work proposed for subcontract, costing not less than 35% value of work to be subletted, in last 5 years, ending last day of month previous to the one in which tender is invited through a works contract
Note: for subletting of work costing up to Rs 50 lakh, no previous work experience of subcontractor shall be asked for by the Railway. In case after award of contract or during execution of work it becomes necessary for contractor to change subcontractor, the same shall be done with subcontractor(s) fulfilling the requirements as per clause 7 of Part-II of SGCC, with prior approval of Chief Engineer in writing. Work experience certificate from private individual shall not be considered. However, in addition to work experience certificates issued by any Govt. Organization, work experience certificate issued by Public listed company having average annual turnover of Rs 500 crore and above in last 3 financial years excluding the current financial year, listed on National Stock Exchange or Bombay Stock Exchange, incorporated/registered at least 5 years prior to the date of closing of tender, shall also be considered provided the work experience certificate has been issued by a person authorized by the Public listed company to issue such certificates. In case tenderer submits work experience certificate issued by public listed company, the tenderer shall also submit along with work experience certificate, the relevant copy of work order, bill of quantities, bill wise details of payment received duly certified by Chartered Accountant, TDS certificates for all payments received and copy of final/last bill paid by company in support of above work experience certificate. The tenderer must have minimum average annual contractual turnover of V or V/N crore, whichever is less; were V= Advertised value of the tender in crore of Rupees N= Number of years prescribed for completion of work for which bids have been invited. The average annual contractual turnover shall be calculated as an average of "total contractual payments" in the previous three financial years, as per the audited balance sheet. However, in case balance sheet of the previous year is yet to be prepared/ audited, the audited balance sheet of the fourth previous year shall be considered for calculating average annual contractual turnover. The tenderers shall submit requisite information as per Annexure-VIB, along with copies of Audited Balance Sheets duly certified by the Chartered Accountant/ Certificate from Chartered Accountant duly supported by Audited Balance Sheet
Similar work :- Wiring/Re-wiring in buildings with associated electrical works like control gear and protection arrangements in residential buildings or service buildings or railway stations /yards or colony/highway lightings. OR Lighting arrangement in buildings, circulating area, yard, street etc. with associated electrical works. OR Wiring/Rewiring, Lighting arrangement in buildings with associated electrical works
Tenderer has to submit attested copy of valid electrical contractors license as per IE rule 45, which can be in his own name or in the name of his firm
E. New Annexure - V(A), Part I of GCC shall be read as under Annexure - V(A), Reference - Para 6.1 of ITT (This certificate is to be given by attorney /authorized signatory /each member of Partnership firm /Joint Venture (JV) / Hindu Undivided Family (HUF)/Limited Liability Partnership (LLP) etc.) I/We.....................................................(Name), attorney /authorized signatory of the .........................................(constituent firm/constituent partner) and member/partner of the ............................................. (tenderering firm) hereby solemnly affirm and state as under: 1. I/we certify that .................................................. (constituent firm /constituent partner) is /are not blacklisted or debarred by Railway or any other Ministry /Department of Govt. of India from participation in tender on the date of submission of bids, either in individual capacity or as a HUF/member of the partnership firm/LLP/JV/Society/Trust. 2. I/We have read the clause regarding restriction on procurement from a bidder of a country which shares a land border with India and certify that I am /We are not from such a country or, if from such a country, have been registered with the competent Authority. I/We hereby certify that I/we fulfill all the requirements in this regard and am/are eligible to be considered (evidence of valid registration by th competent authority is enclosed), SEAL AND SIGNATURE OF THE CONSTITUENT FIRM/CONSTITUENT PARTNER Place :_________________________ Dated:_____________________________
1 condition
Please enter the percentage of local content in the material being offered. Please enter 0 for fully imported items, and 100 for fully indigenous items. The definition and calculation of local content shall be in accordance with the Make in India policy as incorporated in the tender conditions.
(a) Rajkot Division: -Providing 10 bed GRP barrack at RJT& Improvement to GRP police thana at Surendranagar, Rajkot, Jamnagar, Dwarka, Khambhaliya and OKHA & (b)Rajkot Division: -Provision of New Office Building for Reserved Company at Rajkot (RPF).
DRM-RJT-EL-2026-2027-34~WR
DRM-RJT-EL-2026-2027-34
Open
Works - General
6 Months
Rajkot, Gujarat
₹0
₹1.3 L
9 Sept 2026
9 Sept 2026
17 Sept 2026
134 items across 2 schedules
| # | Description | Unit | Qty | Rate | Amount |
|---|---|---|---|---|---|
| — | — | — | 17,17,376.12 | ||
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of concealed/surface wiring of light, fan and call bell point with modular switch board by 3 nos. 1.5 sq. mm. FRLS PVC insulated copper conductor multi-stand single core in PVC conduit pipe/casing caping and accessories. point wiring length up to and including 06 meters per technical specification | — | — | — | 71,588.8 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of additional length of wiring where length of wiring of light, fan and call bell point exceeds 06 meters concealed/surface wiring by 3 nos. 1.5 sq. mm. FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe/casing caping per technical specification. | — | — | — | 713 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of concealed/surface wiring of modular plug point 6 Amp 3 pin with modular switch on same board by 3 nos. 1.5 sq. mm. FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe/casing caping and accessories per technical specification. | — | — | — | 8,644.3 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of concealed/surface wiring of modular plug point 16/6 Amp with 5 pin modular switch on separate board by 3 nos. 4 sq. mm. FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe/casing caping and accessories per technical specification. | — | — | — | 10,401.4 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of concealed wiring of 3 nos. 2.5 mm sq. FRLS PVC insulated copper conductor multi stranded single core in PVC conduit pipe as per Technical Specification | — | — | — | 63,216 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of concealed wiring of sub main by 3 Nos. 4 sq. mm FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe as per Technical Specification | — | — | — | 28,101 | |
| — | Item Breakup | for details. | — | ||
| Supply of material, Installation, testing & commissioning of octagonal hot dip galvanized street light pole or similar complete per technical specification. | — | — | — | 1,46,208.9 | |
| — | Item Breakup | for details. | — | ||
| Supply, Installation, Connecting, testing and commissioning of LED 40-45 W with GI pipe clamp of street light complete per technical specification. | — | — | — | 76,168.4 | |
| — | Item Breakup | for details. | — | ||
| Supply, wiring, fixing, connecting testing and commissioning of energy efficient LED 18-20 W tube light fitting complete per technical specification | — | — | — | 41,266 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of 40 Watt weather proof LED Light fittings IP65 complete with all associated accessories. The contractor shall provide the mounting arrangement for fittings as required at site and as per technical specification. | — | — | — | 62,238.9 | |
| — | Item Breakup | for details. | — | ||
| Supply and Erection of LED tube light 18-20 watts batten dims to 4watt when no motion is detected for 20/30 seconds; TYPE-T5, Colour: Cool White, 100 lumens/watts. Detection Range 8mtrs, CRI > 80%. Diffuser Milky White. As per detailed technical specification | — | — | — | 6,894.2 | |
| — | Item Breakup | for details. | — | ||
| Supply, Installation, connecting, testing and commissioning of night light above plinth level complete per technical specification | — | — | — | 6,712.8 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing and commissioning of celling fan 1400 mm with down road, remote complete per technical specification | — | — | — | 1,49,152.8 | |
| — | Item Breakup | for details. | — | ||
| Fixing, testing and commissioning of electronic fan regulator suitable capacity complete fitting per technical specification | — | — | — | 17,579.6 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of 300 mm sweep heavy duty exhaust fan as per technical specification | — | — | — | 25,547 | |
| — | Item Breakup | for details. | — | ||
| Supply of Plastic Body Floor Standing with integral caster wheels Mosquito Breeding Proof Desert Cooler as per technical specification | — | — | — | 1,50,576 | |
| — | Item Breakup | for details. | — | ||
| Supply, Installation, connecting, testing and commissioning of vertical type 15 Ltrs. Capacity water heater (Geyser) per technical specification. | — | — | — | 17,559.22 | |
| — | Item Breakup | for details. | — | ||
| Supply, fixing, connecting, testing and commissioning of 16Amp 30mA RCBO with powder coated MS enclosure. as per Technical Specification. | — | — | — | 3,112 | |
| — | Item Breakup | for details. | — | ||
| Supply of 4x16 sq mm LT underground cable for Working Voltages Up to and including 1100 Volts as per Technical Specification | — | — | — | 81,255 | |
| — | Item Breakup | for details. | — | ||
| Supply of 4x25 sq mm LT underground cable for Working Voltages Up to and including 1100 Volts as per Technical Specification | — | — | — | 1,65,440 | |
| — | Item Breakup | for details. | — | ||
| Digging of cable trench 450X1000 mm & refilling as per technical specification. | — | — | — | 40,545 | |
| — | Item Breakup | for details. | — | ||
| Digging of Cable trench 450X1000mm in RCC/PCC/Hard Soil & Refilling as per technical specification. | — | — | — | 1,02,102.5 | |
| — | Item Breakup | for details. | — | ||
| Transportation, laying, installation, terminating, testing and commissioning of LT/HT cable of sizes 4 core 10 sq. mm. to 4 core 300 sq. mm. in existing trench, pipe or on structure as per technical specification. | — | — | — | 31,510 | |
| — | Item Breakup | for details. | — | ||
| Supply and laying of 50 mm DWC pipe for cable laying in circulating area pole/parking/footpath as per technical specification. | — | — | — | 61,345 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of HDPE Pipe 160 mm Nominal Dia, 6.2 mm thickness & Laying of HDPE/GI pipe by Push through Method under track/Road. per technical specification. | — | — | — | 95,474 | |
| — | Item Breakup | for details. | — | ||
| — | Item Breakup | for details. | — | ||
| — | Item Breakup | for details. | — | ||
| — | — | — | 29,499.5 | ||
| — | Item Breakup | for details. | — | ||
| — | — | — | 7,650 | ||
| Supply of Busbar Chamber Capacity 100 Amp wall mounted type 06 wayas per technical specification | — | — | — | 31,860 | |
| Supply of materials and providing 50 mm dia. G.I. pipe earthing with B class GI pipe as per IS 3043- 1987as amended latest per technical specification | — | — | — | 38,004 | |
| Supply and fixing G.I. strip hot dip galvanized of size 25 mm x 6mm for earthing, including cutting, bending, welding, excavation etc. per technical specification | — | — | — | 13,120.8 | |
| — | — | — | 48,39,943.72 | ||
| — | Item Breakup | for details. | — | ||
| Supply of material and carryout concealed wiring of Light / Fan Points without pipe up to 6 meters with FRLS PVC insulated, multistrand three Nos. copper wires of 1.5 sq.mm for phase, neutral and earth continuity conforming to IS694 (as amended latest). The point wiring shall include supply & providing modular switches with complete associate accessories such as chromium plated metal boxes, modular plates, cover plate, lamp holders, and three pin ceiling rose, adaptor etc. As per technical specification | — | — | — | 2,23,715 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing &commissioning of additional length of wiring where length of wiring of light, fan and call bell point exceeds 06meters concealed/surface wiring by 3nos.1.5sq.mm.FRLSPVC insulated copper conductor multi-strand single core in PVC conduit pipe/casing caping as per specification. | — | — | — | 2,852 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing &commissioning of concealed/surface wiring of modular plug point 6Amp 3pin with modular switch on same board by 3 nos. 1.5 sq .mm .FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe/casing caping and accessories. | — | — | — | 15,162.6 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing &commissioning of concealed/surface wiring of modular plug point16/6Amp with 5 pin modular switch on separate board by 3 nos. 4 sq.mm. FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe/casing caping and accessories. | — | — | — | 9,891.4 | |
| — | Item Breakup | for details. | — | ||
| Supply, erection, testing & commissioning of concealed wiring of 3 nos.2.5. mm sq FRLS PVC insulated copper conductor multi stranded single core in PVC conduit pipe as per Technical Specification | — | — | — | 79,020 | |
| — | Item Breakup | for details. | — | ||
| Supply, installation, testing & commissioning of concealed wiring of sub main by 3 Nos. 4 sq. mm FRLS PVC insulated copper conductor multi-strand single core in PVC conduit pipe as per Technical Specification | — | — | — | 61,590 | |
| — | Item Breakup | for details. | — |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
HTML
nit.pdf
NIT
GCCwithACS11.pdf
ATTACHMENT
ACS12GCCforWorks.pdf
ATTACHMENT
GCCApril2022final.pdf
ATTACHMENT
AnnexureVA.pdf
ATTACHMENT
AnnexureVIB.pdf
ATTACHMENT
Termandcondition10bedGRPbarracknewofficebuildingRPF.pdf
ATTACHMENT
TenderSpecforProviding10bedGRPbarrackNewofficebuildingRPF_1.pdf Tender specification
ATTACHMENT
TenderSpecforProviding10bedGRPbarrackNewofficebuildingRPF_1.pdf
ATTACHMENT
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .