Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹72.7 LAccepted-AOC H NO 698 SECTOR 10 PANCHKULA HARYANA 134109 | PANCHKULA | PANCHKULA | HARYANA | 134109 | L1 | Accepted-AOC Being lowest bidder | |
| 2 | L2₹76.8 L+₹4.1 L (5.64%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L2 | Rejected-Finance Not lowest bidder | |
| 3 | L3₹77.7 L+₹5.0 L (6.82%)Rejected-Finance FLAT NO 151 BLOCK NO 1 DIAMOND SQUARE CGHS LTD PLOT NO 13A SECTOR 6 DWARKA NEW DELHI 110075 | NEW DELHI | SOUTH WEST DELHI | DELHI | 110075 | L3 | Rejected-Finance Not lowest bidder | |
| 4 | L4₹78.1 L+₹5.4 L (7.44%)Rejected-Finance 441 G F LIG FLATS PH 2 SEC 14 PKT 3 DWARKA NEW DELHI SECTOR 14 DWARKA DWARKA SOUTH WEST DELHI DELHI 110078 | SOUTH WEST DELHI | DELHI | 110078 | L4 | Rejected-Finance Not lowest bidder | |
| 5 | L5₹85.6 L+₹12.9 L (17.7%)Rejected-Finance | L5 | Rejected-Finance Not lowest bidder |
| Sl No | Description | Qty | Unit | Esha Engineers L6 | R D Bansal L2 | KULBHUSHAN AGGARWAL L5 | Raman Electric Trading Co L7 | BRIJ MOHAN LAL AND CO. L3 | bharat contrectors L1 | OMVIN ENTERPRISES LLP L4 |
|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Material and labour for taking down the old ceiling fan of any make and Supply and fixing connecting & testing of ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed.
Notes:- (a) Old taking down ceiling fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 339 | Each | 3,100 ₹10,50,900 | 2,650 ₹8,98,350 | 2,450 ₹8,30,550 | 3,150 ₹10,67,850 | 2,437 ₹8,26,143 Lowest | 2,470 ₹8,37,330 | 2,650 ₹8,98,350 |
| 2.00 | Material and labour for taking down the old ceiling fan of any make and Supply and fixing connecting & testing of ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1400 sweep , Min air delivery 245 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed.
Notes:- (a) Old taking down ceiling fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 478 | Each | 3,300 ₹15,77,400 | 2,830 ₹13,52,740 | 2,600 ₹12,42,800 Lowest | 3,300 ₹15,77,400 | 2,697 ₹12,89,166 | 2,970 ₹14,19,660 | 3,000 ₹14,34,000 |
| 3.00 | Material and labour for taking down the old exhaust fan of any make and Supply and fixing exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Notes:- Old taking down exhaust fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 8 | Each | 2,000 ₹16,000 | 1,930 ₹15,440 Lowest | 2,400 ₹19,200 | 2,500 ₹20,000 | 2,145 ₹17,160 | 2,530 ₹20,240 | 2,600 ₹20,800 |
| 4.00 | Material and labour for taking down the old exhaust fan of any make and Supply and fixing exhaust fan 450 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Notes:- Old taking down exhaust fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 23 | Each | 6,000 ₹1,38,000 | 4,810 ₹1,10,630 Lowest | 6,000 ₹1,38,000 | 4,900 ₹1,12,700 | 4,999 ₹1,14,977 | 4,990 ₹1,14,770 | 5,500 ₹1,26,500 |
| 5.00 | Material and labour for taking down the old split type unit of any make and capcity and Supply and fixing connecting & testing of air cooled split unit indoor & outdoor complete with cordless remote control unit air conditioner electric driven,single phase 230V, 50 hz, turbo cooling, inverter type of capacity of 1.5 TR, BEE 5 star rated inverter split AC with anti dust filter, copper condensor, R-32 refrigerant,Environment friendly- no ozone depletion potential & low global warming potential with & including suitable MS mounting stands for indoor and outdoor unit including connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe, energy efficient, high ambient cooling, anti microbial air filtration, self dignosis, LED Display and Completed all as specified and directed. NOTES :
(a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(b). Old taking down split AC shall be deposited to E/M-II store yard.
(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 18 | Each | 55,000 ₹9,90,000 | 49,000 ₹8,82,000 | 65,000 ₹11,70,000 | 52,000 ₹9,36,000 | 49,000 ₹8,82,000 | 42,000 ₹7,56,000 Lowest | 43,000 ₹7,74,000 |
| 6.00 | Material and labour for taking down the old split type unit of any make and capcity and Supply and fixing connecting & testing of air cooled split unit indoor & outdoor complete with cordless remote control unit air conditioner electric driven,single phase 230V, 50 hz, turbo cooling, inverter type of capacity of 2.0 TR, BEE 5 star rated inverter split AC with anti dust filter, copper condensor, R-32 refrigerant,Environment friendly- no ozone depletion potential & low global warming potential with & including suitable MS mounting stands for indoor and outdoor unit including connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe, energy efficient, high ambient cooling, anti microbial air filtration, self dignosis, LED Display and Completed all as specified and directed. NOTES :
(a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(b). Old taking down split AC shall be deposited to E/M-II store yard.
(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 4 | Each | 65,000 ₹2,60,000 | 67,000 ₹2,68,000 | 75,000 ₹3,00,000 | 70,000 ₹2,80,000 | 72,500 ₹2,90,000 | 52,000 ₹2,08,000 Lowest | 55,000 ₹2,20,000 |
| 7.00 | Material and labour for dismantling the old split type unit of any make and capcity and Supply and fix connecting / testing of air cooled split unit indoor/outdoor complete with cordless remote control unit air conditioner electric driven,three phase 415V, 50 hz of capacity 3 TR, BEE Star rating, copper condensor,Refrigerant R-32 / R-410A (Eco-friendly, non-ozone depleting),MS mounting stands for indoor and outdoor unit includig connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe,energy efficient, high ambient cooling , anti microbial air filtration, self dignosis,LED Display and Completed all as specified and direted. NOTES :
(a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(b). Old taking down split AC shall be deposited to E/M-II store yard.
(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 2 | Each | 1,15,000 ₹2,30,000 | 96,000 ₹1,92,000 | 75,000 ₹1,50,000 Lowest | 1,00,000 ₹2,00,000 | 79,000 ₹1,58,000 | 85,000 ₹1,70,000 | 1,00,000 ₹2,00,000 |
| 8.00 | Material and labour for taking down the old window AC unit of any make and capcity and Supply and fix connecting & testing of heav duty window type air conditioner with cordless remote control unit,Cooling Capacity Full Load 5100W, Cooling Capacity Half Load 2550W inverter type,single phase 230V, 50 hz of capacity of 1.5TR, copper condensor coil, R-32 Eco Friendly Refrigerant,Turbo Cooling, LED Display, energy efficient, BEE 5 star rated Completed all as specified and direted.
Notes:- (a) Old taking down window AC shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 1 | Each | 36,000 ₹36,000 | 58,000 ₹58,000 | 45,000 ₹45,000 | 53,000 ₹53,000 | 45,000 ₹45,000 | 32,000 ₹32,000 Lowest | 44,000 ₹44,000 |
| 9.00 | Material and labour for taking down the old refrigerator of any make and capcity and Supply and fixing connecting & testing of refrigerator, electric driven single phase 230V, 50 hz, single door, capacity not less than 185 Litres or nearest higher capacity . BEE star rated Completed all as specified and direted.
Notes:- (a) Old taking down refregerator shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 6 | Each | 15,000 ₹90,000 Lowest | 16,600 ₹99,600 | 19,500 ₹1,17,000 | 18,500 ₹1,11,000 | 24,500 ₹1,47,000 | 35,000 ₹2,10,000 | 23,000 ₹1,38,000 |
| 10.00 | Material and labour for dismantling the old desert cooler of any make and capcity and Supply and fix connecting / testing of desert cooler electric driven single phase230V, 50 hz, having nominal Air Delivery 4000 CFM ±5% ,window type, with copper wound exhaust fan (metal blades) Motor Speed 1350–1450 RPM, Fan Diameter 18" to 20" (450–500 mm),Power Consumption 400–600 W (approx.),Heavy gauge galvanized steel body including honey compo pads,Water Tank Capacity 60–80 liters Dimension (Approx.) 700 mm × 650 mm × 950 mm (L×W×H),Overhead water distributor with plastic piping Pump Type Submersible water pump18–25 W Completed all as specified and direted.
Notes:- (a) Old taking down desert coolers shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | 31 | Each | 11,500 ₹3,56,500 | 10,850 ₹3,36,350 | 6,500 ₹2,01,500 | 13,400 ₹4,15,400 | 6,075 ₹1,88,325 Lowest | 8,500 ₹2,63,500 | 16,000 ₹4,96,000 |
Tender Value
₹97.7 L
EMD Value
₹1.7 L
Closing Date
28 Apr 2026, 6:00 pmClosed
CWE (AF) Ambala
HQ CWE (AF) Ambala Cantt-133001
CWE/AF AMB/AMB-T68/2025-26 SPECIAL REPAIR REPLACEMENT OF BER EM APPLIANCES PROVN OF EXHAUST FANS AND PROVN OF DEFICIENT SECURITY LIGHTS ALONGWITH CONNECTED ITEMS IN TECHNICAL AND DOMESTIC AREA AT AF STN AMBALA UNDER GE AF AMBALA
2026_MES_758637_1
CWE/AF AMB/AMB-T68/2025-26
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Ambala
For MES enlisted contractor Class C Category b i and for un-enlisted contractor
refer NIT
8 documents required · 8 mandatory
₹1,000
GE (AF) Ambala
₹1.7 L
Yes
11 Aug 2026
1 Apr 2026
30 Apr 2026
1 Apr 2026
28 Apr 2026
22 Apr 2026
1 Apr 2026 - 21 Apr 2026
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | Material and labour for taking down the old ceiling fan of any make and Supply and fixing connecting & testing of ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1200mm sweep , Min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed.
Notes:- (a) Old taking down ceiling fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old ceiling fan of any make and Supply and fixing connecting & testing of ceiling fan complete with blades, down rods, fan regulator socket type and accesssories, 230V , 1400 sweep , Min air delivery 245 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) without reomte complete all as directed.
Notes:- (a) Old taking down ceiling fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old exhaust fan of any make and Supply and fixing exhaust fan 300 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Notes:- Old taking down exhaust fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old exhaust fan of any make and Supply and fixing exhaust fan 450 mm sweep, anti corrsive metal body, sturdy metal bird guard copper wounded, double ball bearing, five star rating,1320 RPM,50HZ, 240 volts complete with dynamically balanced blade for vibration free rotation, split pin, clamp and fixing at site on and including MS fabricated base frame using flexible wire after making hole in wall as required at site and making good the disturbed surfaces and including making the electrical connection by using three core wire with colour code complete all as specified and as directed by Engineer-in-Charge.
Notes:- Old taking down exhaust fan shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old split type unit of any make and capcity and Supply and fixing connecting & testing of air cooled split unit indoor & outdoor complete with cordless remote control unit air conditioner electric driven,single phase 230V, 50 hz, turbo cooling, inverter type of capacity of 1.5 TR, BEE 5 star rated inverter split AC with anti dust filter, copper condensor, R-32 refrigerant,Environment friendly- no ozone depletion potential & low global warming potential with & including suitable MS mounting stands for indoor and outdoor unit including connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe, energy efficient, high ambient cooling, anti microbial air filtration, self dignosis, LED Display and Completed all as specified and directed. NOTES :
(a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(b). Old taking down split AC shall be deposited to E/M-II store yard.
(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old split type unit of any make and capcity and Supply and fixing connecting & testing of air cooled split unit indoor & outdoor complete with cordless remote control unit air conditioner electric driven,single phase 230V, 50 hz, turbo cooling, inverter type of capacity of 2.0 TR, BEE 5 star rated inverter split AC with anti dust filter, copper condensor, R-32 refrigerant,Environment friendly- no ozone depletion potential & low global warming potential with & including suitable MS mounting stands for indoor and outdoor unit including connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe, energy efficient, high ambient cooling, anti microbial air filtration, self dignosis, LED Display and Completed all as specified and directed. NOTES :
(a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(b). Old taking down split AC shall be deposited to E/M-II store yard.
(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for dismantling the old split type unit of any make and capcity and Supply and fix connecting / testing of air cooled split unit indoor/outdoor complete with cordless remote control unit air conditioner electric driven,three phase 415V, 50 hz of capacity 3 TR, BEE Star rating, copper condensor,Refrigerant R-32 / R-410A (Eco-friendly, non-ozone depleting),MS mounting stands for indoor and outdoor unit includig connecting Cu cable and connecting copper pipe up to 5 mtr length, drain pipe,energy efficient, high ambient cooling , anti microbial air filtration, self dignosis,LED Display and Completed all as specified and direted. NOTES :
(a). The rates quoted shall deem to include the cost of cutting holes in the brick wall for passing copper tubing and making good the surfcaes to match with adjoining surfaces include fixing with angle iron into any type of wall for out door unit whereever reqd.
(b). Old taking down split AC shall be deposited to E/M-II store yard.
(c) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old window AC unit of any make and capcity and Supply and fix connecting & testing of heav duty window type air conditioner with cordless remote control unit,Cooling Capacity Full Load 5100W, Cooling Capacity Half Load 2550W inverter type,single phase 230V, 50 hz of capacity of 1.5TR, copper condensor coil, R-32 Eco Friendly Refrigerant,Turbo Cooling, LED Display, energy efficient, BEE 5 star rated Completed all as specified and direted.
Notes:- (a) Old taking down window AC shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for taking down the old refrigerator of any make and capcity and Supply and fixing connecting & testing of refrigerator, electric driven single phase 230V, 50 hz, single door, capacity not less than 185 Litres or nearest higher capacity . BEE star rated Completed all as specified and direted.
Notes:- (a) Old taking down refregerator shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
| - | Material and labour for dismantling the old desert cooler of any make and capcity and Supply and fix connecting / testing of desert cooler electric driven single phase230V, 50 hz, having nominal Air Delivery 4000 CFM ±5% ,window type, with copper wound exhaust fan (metal blades) Motor Speed 1350–1450 RPM, Fan Diameter 18" to 20" (450–500 mm),Power Consumption 400–600 W (approx.),Heavy gauge galvanized steel body including honey compo pads,Water Tank Capacity 60–80 liters Dimension (Approx.) 700 mm × 650 mm × 950 mm (L×W×H),Overhead water distributor with plastic piping Pump Type Submersible water pump18–25 W Completed all as specified and direted.
Notes:- (a) Old taking down desert coolers shall be deposited to E/M-II store yard.
(b) The above appliances may be procured either directly from the manufacturer or their authorised dealers. In both cases, a "Pre dispatch" inspection at the "Factory Premises" shall be carried out by the Engineer-in-Charge alongwuth the representative of "Accepting Officer" to verify the major sepifications, star rating and factory test results. All such record shall be produced before the GE while releasing payment to the contractor. The "Pre dispatch" inspection shall be coordinated by the contractor to facilitate the necessary checks and verification. | - | Each | - | - |
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.27 MB
Tender68T.pdf
Tender Documents • 1.03 MB
BOQ_849730.xls
BOQ • 6.83 MB
Amendment68.pdf
PDF • 0.19 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .