Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.7 LAccepted-AOC | L1 | Accepted-AOC Due to L1 | |
| 2 | L2₹10.7 L+₹94,450 (9.69%)Rejected-Finance H NO 19 6 243 1 NGO S COLONY SHIV NAGAR NORTH BIDAR 585401 | BIDAR | KARNATAKA | 585401 | L2 | Rejected-Finance Due to L2 | |
| 3 | L3₹11.3 L+₹1.6 L (16.4%)Rejected-Finance | L3 | Rejected-Finance Due to L3 |
Tender Value
Refer Docs
EMD Value
₹24,000
Closing Date
18 Nov 2020, 6:00 pmClosed
GE (AF) Bidar
GE AF Bidar, Naubad road, Bidar, Karnataka 585401
REPAIRS AND CLEANING OF SEWAGE LINES, MANHOLES, SEPTIC TANKS AND MISC WORKS IN TECHNICAL AREA AT AFS BIDAR
2020_MES_388278_1
8247/E8
Open Tender
Civil Works
Item Rate
180 days
GE (AF) Bidar
As per NIT
7 documents required · 7 mandatory
₹500
GE (AF) Bidar
₹24,000
Yes
11 Dec 2020
20 Oct 2020
19 Nov 2020
20 Oct 2020
18 Nov 2020
4 Nov 2020
Amount
Opening /Cleaning and making operational the blocked water closet (Indian/orrisa or English type) at any floor including cleaning of traps and CI drain pipe (any type and any position) from WC's/trap to manhole Cleaning and well flushing, pressure pumping, taking out all residues etc and removing the same to a distance not exceeding 1000m, burried the same underground in low lying area and covering the same with earth including removal of surplus soil to a distance not exc 500m. complete all as specified and directed.
Cleaning of blocked sewage lines of any dia and including man holes (between manhole to manhole and man hole to septic tank) of depth upto 1.50m by rodding with bamboo and gunny bags and removing muck sludge/silt/liquid/night soil (in foul position) and removing the same using sealed tins or sludge removal tankers to a distance exc 50m outside of MD land premises and refixing the manhole covers in same position and testing of man holes by filling with water etc complete all as directed.
All as per item No. 2 here in before but for depth exc 1.5m but not exc 3.00 m.
Cleaning of man hole chamber up to 1.50m depth, cleaning and removing muck sludge/ silt/ liquid mud etc (in foul position), and removing the same using sealed tins or sludge removal tankers to distance exc 50m outside of MD land premises including removing/ refixing the manhole covers in same position and testing of manholes by filling with water etc complete, all as directed.
All as per item No. 4 here in before but for depth exc 1.50m and not exc 3.00m.
Cleaning of Septic tank, Soak wells by opening covers, removing/ bailing out liquid alongwith floating material sludge from any position in foul conditions by mechinical means by using suction pump, hose pipe and its accessaries shall be mounted on vehicle so that pumping can be easily be carryout and clean the inlets and outlets with water, including removing/placing the covers back in position and disposing off the sludge to a distance exceeding 50m outside MD land premises complete including rough excavation for burring the liquid sludge inside the excavated area and levelling the same all as specified and as directed by the engineer in charge. Notes:- (i) Internal size of septic tank upto existing liquid depth will be measured for payment. (ii) The tenderer has to take cognizance of the approch to septic tank and the length of hose pipe required for pumping the sewage. No extra claim what so ever arising shall be entertained on this account. The unit rate quoted shall be deemed to include this aspect.
Cleaning of Septic tank/Soak well by taking out muck/sludge/silt/mud etc under any position including foul condition manually and disposing off the same in sealed tins to a distance exceeding 50 m out side MD land complete all as specified and as directed.
Surface dressing around septic tank/filter bed, soak well within fencing n.exc 15 cm deep in hard/ dense soil including cleaning away all grass, vegitations, saplings, shrubs, bushes, weed under growth, roots, trees n.exc 30cm girth etc and removing rubbish to a distance 50m and depositing where directed complete all as directed.
Excavating in trenches, n exc 1.5 m wide and n exc 1.5 m in depth; for foundation, etc. or for manholes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out in hard/ dense soil all as specified and directed.
Returning filling in including spreading leveling and well ramming in layers n.exc 25 cm thick.
Removing excavated material to a distance n.exc 50 m and depositing where directed at a level n.exc 1.50m from starting point.
Demolition of brick work/PCC block masonry built in cement mortar.
Demolition of cement concrete of any description and in any position not otherwise specifically provided for complete all as specified and directed.
Demolition of reinforced cement concrete of any description and in any position not otherwise specifically provided for cover slabs and similar work all as specified.
Plain cement concrete 1:4:8, type D-2 using 40mm graded stone aggregate as in foundation for Man holes etc.
Precast Cement concrete block masonry with solid blocks, type C1, 1:3:6 using 20 mm graded stone aggregate, exc 10 cm in width and setting in cement mortar 1:4, complete.
Plain cement concrete 1:2:4, type B-1 using 20mm graded stone aggregate as in benching inside manholes complete all as specified and directed.
Extra for forming fair finished channel or drain 30cm inner girth in cement concrete using extra cement including mitred/ stopped ends, forms mould etc, complete.
Plain cement concrete 1:3:6, type C-1 using 20mm graded stone aggregate as in bed block / coping including necessary form work.
Precast RCC 1:2:4 type B-1 using 20 mm graded stone aggregate, as in cover slab set and jointed in CM 1:6 including necessary form work. Note: Reinforcrment steel will be measured and paid seperately.
Rendering 15mm thick in CM (1:4) on fair faces of brick work or concrete surfaces mixed with approved water proofing compound as per manufacturers instructions, finished even and smooth with out using extra cement. Note: Supply only of water proofing compound will be measured and paid separately.
Supply only of integral water proofing compound.
Reinforcement for concrete with mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking bending and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips, all as specified and directed.
Demolition and breaking up drain pipes (SGSW, AC or RCC) 100 mm internal dia including concrete bed and haunching against the sides of pipes complete all as specified.
Demolition and breaking up drain pipes (SGSW, AC or RCC) 150 mm internal dia including concrete bed and haunching against the sides of pipes complete all as specified.
Salt glazed stone ware pipe Grade 'A' laid in trenches and jointed with cement nominal dia of pipe 100 mm.
Salt glazed stone ware pipe Grade 'A' laid in trenches and jointed with cement nominal dia of pipe 150 mm.
Plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 100 mm bore pipe.
Plain cement concrete 1:4:8, type D-2 using 40mm graded crushed stone aggregate as in bed to drain pipe including packing under and haunching against the sides of pipes after they are laid and tested for 150 mm bore pipe.
Mild steel miscellaneous works such as handles/rungs with round bars all as specified and directed.
ramesh construction co
Siddique constructions
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .