Loading…
India Infra Updates on WhatsApp
Join the Tenderkart WhatsApp channel for India Infra Updates
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹14.8 LAccepted-AOC 301 2 SILVERLINE COMPLEX OPP BBC TOWER SAYAJIGUNJ VADODARA 390005 GUJARAT | VADODARA | VADODARA | GUJARAT | 390005 | L1 | Accepted-AOC L1 Status | |
| 2 | Not Admitted-Fee/PreQual/Technical PLOT NO 36 FLAT NO D 1ST CROSS STREET GOWRI NAGAR MUGALIVAKKAM CHENNAI TAMILNADU 600125 | CHENNAI | TAMIL NADU | 600125 | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received | |
| 3 | Not Admitted-Fee/PreQual/Technical NEAR SANSKAR SCHOOL PRABHAKAR NAGAR GAMBHIRIYA MAKRONIYA SAGAR | VIDISHA | MADHYA PRADESH | 464240 | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received | |
| 4 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received |
Tender Value
₹16.0 L
EMD Value
₹32,040
Closing Date
6 Jul 2024, 6:45 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
General Manager, HWP(M)
General Manager, HWP(M)
Testing of Protection relays and meters at Captive Power Plant, HWP(Manuguru) during MTA-2024
2024_HWB_813082_1
HWPM/EU/Meters/MTA/2024/NIT Dt.19.06.2024
Open Tender
Electrical Works
Item Rate
180 days
CPP, HWP(M), Works
Please refer Tender documents.
2 documents required · 2 mandatory
₹0
₹32,040
19 Oct 2024
27 Jun 2024
12 Jul 2024
27 Jun 2024
6 Jul 2024
27 Jun 2024
27 Jun 2024 - 2 Jul 2024
Amount
Item 1: Class IV Relays
3 phase, M/s Areva make, Type P442 Microprocessor based Distance protection relay.
3 phase M/s Areva make Type P343 relay (TG-4)
3 phase M/s Areva make P111 Non directional Over Current and Earth fault relay (TG-4)
3 phase percentage biased Differential protection relays of Type:RADSB, ASEA make
Restricted Earth fault relays on LV side of Type RADHD, ASEA make.
3 phase High Impedance Differential relays of Type RADHA, ASEA make
3 phase Over Current/ Earth fault protection relays [3 element] of Type RXIDF2H, ASEA make
3 phase Directional Over Current / Directional Earth fault/ Reverse power /Low Forward power Type RXPE 40/42/47, ASEA make
Generator Over load protection relays RXIG, ASEA make.
Generator Minimum Impedance stage I, stage II protection relays of Type RAKIB, ASEA make.
Generator Out of Step Protection Relay Type RXZP+RXPE, ASEA make.
Generator Rotor Earth Fault Relay State I, Stage II Type RXNB, ASEA make.
Generator Stator 0-95%,100% E/F protection relays of Type RAGEA, ASEA make
Over Fluxing / Loss of Excitation protection relays RAGPC, ASEA make.
Negative Sequence protection relays of Type RARIB, ASEA make.
Under Frequency relays of RXFE4, ASEA make.
3 phase Voltage balance scheme / Over Voltage protection relays of Type RXEG21, ASEA make.
Local Breaker Back up protection relays of Type RAICA, ASEA make
Schneider make P127 Micom Directional Over Current and Earth fault relay
ABB make REG 670 (Generator-2)
ABB make RET 670 (GT-2,UAT-2)
M/s ABB make SPAF340C3 df/dt
Check synchronizing relays of Type SKD, EE make
Check synchronizing relays of Type SKE, EE make
VAEM Rotor Earth fault relay (TG-4)
WCDM Reverse power relay (TG-4)
CAEM Battery Earth fault relays
Instantaneous differential Protection Relay of CAG type EE make
3 phase Over Current &E/F relays of Type : SPAJ 140,M/s. ABB make
3 phase inverse type over current relays, type CDG 31/33/63, Egnlish electric make
Instantaneous under voltage relays on various 6.6 KV, 415 V MCC, type VAGM/VAG English Electric make.
Motor protection relays of type SPAM 150, M/S. ABB make
Check Synchronising Relay Argus-7 2732H33008 of Siemens Make
SPAD 346C ABB make
Definite time relay VTT11, English Electric make
Master trip relay, VAJH/VAJS/VAJHM type, English Electric make
Neutral displacement relay, Type: VDG, Make:EE
Item 2: Class III relays
3 phase O/C (inverse) & E/F relay, Type-CDG, Make-EE
Neutral Displacement relay , Type-VDG, Make-EE
Instantaneous Differential relay , Type-CAG, Make-EE
Instantaneous U/V relay , Type-VAG, Make-EE
Instantaneous O/V relay , Type-VAG, Make-EE
Definite time Reverse Power relay , Type-CCUM, Make-EE
3 phase O/C (inverse) relay , Type-CDG, Make-EE
Instantaneous U/V relay , Type-VAGM, Make-EE
O/C relay(inverse) and E/F relay , Type-CDG, Make-EE
Item 3: Testing of meters
AC ammeters of range varying from 0-50 amps to 0-4000 amps with secondaryCT current of 1/ 5 A.
DC ammeters of range varying from 0-50 amps to 0-1000 amps.
AC voltmeters of range Varying from 0-220 KV to 0-150 volts with Secondary PT voltage of 110 V or 110 /√3 volts or direct 415 volts without PT.
DC voltmeters of range varying from 0-50 V to 0- 500 V.
MW Meters of range varying from 0-25 MW to 0-100 MW with CT secondary of 1A or 5A, secondary PT voltage of 110V or 110/√3 volts with transducers of 4-20 mA
Watt meters of range varying from 630 KW to 2000 KW with CT secondary of 1A Or 5A , PT Secondary Voltage 110 V or 110/√3 Volts.
Mvar meters of range varying from 0-20 to 0-80MVAR both in lagging and leading side with CT secondary of 1A or 5A, secondary PT voltage of 110V or 110 / √3 volts with transducers of 4-20 mA.
Frequency meters of range varying from 0-50 Hz, 45-55Hz, 45-0-55Hz with secondary PT voltage of 110 volts.
Synchronous Scopes with secondary PT voltage of 110 volts.
KWH meters with CT Secondary of 1A Or 5A, Secondary PT Voltage of 110 V Or 110/√3 Volts.
KVAH meters with CT secondary current of 1A or 5A and PT secondary voltage of 110 Volts or 110/√3 volts.
KVARH meters with CT secondary current of 1A or 5A and PT secondary voltage of 110 Volts or 110/√3 Volts.
Power factor meters of both lagging and leading side.
stage.html
html • 0.05 MB
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .