Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹30.1 LAccepted-AOC NAJISH INFRA BALLIWALA CHAWK INDIRA NAGAR ROAD DEHRADUN UTTARAKHAND 248001 | DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | 1 | Accepted-AOC AOC accepted. | |
| 2 | 2₹41.3 L+₹6.3 L (18.0%)Rejected-Finance WZ 1391 31 B NANGAL RAYA NEW DELHI 110046 | NEW DELHI | NEW DELHI | DELHI | 110046 | 2 | Rejected-Finance other than L1 | |
| 3 | 3₹41.3 L+₹6.4 L (18.2%)Rejected-Finance H NO 1366 3 GALI NO 6 MATA ROAD NEAR HAPPY MODEL SCHOOL RAJIV NAGAR GURGAON 122 001 HARYANA | GURGAON | GURGAON | HARYANA | 122001 | 3 | Rejected-Finance other than L1 |
Tender Value
Refer Docs
EMD Value
₹99,400
Closing Date
12 Dec 2023, 6:00 pmClosed
GE P DDN
GE P DDN
REPAIR/ RENOVATION OF SPORTS COMPLEX OF HQ COY, SFF HOSP, ARCHER COLN, VECTOR COLN, SIG COY, 34 VG SFF RECORDS AT AGE B/R (P) CHAKRATA UNDER GE (P) DEHRADUN
2023_MES_627662_1
GE P/ DDN/T-39 OF 23-24
Open Tender
Civil Works
Item Rate
80 days
Chakrata
Please refer Tender documents.
10 documents required · 10 mandatory
₹500
GE P DDN
₹99,400
Yes
13 Feb 2024
10 Nov 2023
14 Dec 2023
10 Nov 2023
12 Dec 2023
24 Nov 2023
Amount
Dismantling of plain or corrugated steel sheeting, any gauge, thickness, including Nainital or similar pattern roof coverings complete all as specified and directed.
Dismantling wall and ceiling board fiber, pulp insulation etc or insulation boards any thickness including cover fillets complete all as specified .
Dismantling structural steel work including doors, gates but excluding framed truss etccomplete all as specified and directed.
Demolition of brick /stone work , built in cement mortar or cement lime mortar including all quoins, arches, pillars, etc including demolition of precast RCC articles and disposal of debris out of MoD land complete all as specified and directed.
Demolition of Cement concrete (unreinforced) in ground floors and pavings n exc 15 cm thickness (below or above ground level) complete all as specified and directed.
Dismantling boarding, any descripition, fixed in any position with nail all as specified and directed
Taking down chowkhats or frames exc 1.50 and n.exc 4 Sqm each (without talking off shutters from the frame) complete all as specified and directed.
Taking down chowkhat or frames with shutters (without taking off shutters from the frames) area not exc1.5 Sqm each and removing from site.
Dismantling floor, hearth or wall tiling including cement mortar bedding (but not backing) removing serviceable tiles to store and rubbish off the premises complete all as specified and directed.
M&L of PVC wall panel of 10 feet length & 10mm thick cyclone wooden matt finish with PVC-U and bottom channels and R strip a uPVC section of size 35mm x10mm & 1.00mm average wall thickness, the distance between two R strips should not exceed 600mm, uPVC hollow multi chambered section taipan of size 255mm x7mm x0.7mm/0.2mm average wall thickness will be fixed to the R strip with synthetic wooden coating of panels complete all as specified and directed.
M&L 40 mm thick PCC 1:2:4 type B-0 using 12.5 mm thick agg thick as in sub base/base of floor complete all as specified and directed.
S&F Monopoly wooden flooring of 8 mm thick incl polishing duly approved by the GE complete all as specified and directed.
S&F synthetic Gym Flooring 24 mm thick the GE approved for Seprate wt lifting area complete all as specified and directed.
S&F of 8mm thick and 8 feet length of Super Clear mirrors Silvered Float Glass, Polished all Round, Foil Safety Backing, completely lead-free top coat and <0.15% lead in the wet basecoat with all fittings complete all as specified and directed.
M&L for 75mm thick PCC 1:2:4 type B-1 using 20 mm graded aggregate as in floors hard standings complete all as specified and as directed.
M&L for SYNTHETIC 8 LAYER OUTDOOR SPORTS SYNTHETIC SURFACE as per below specification of 8 layers as fallows :- 1st layer of applying Acrylic Resurface mixed with approved grade of silica sand and cement and water and applied with rubber squeegee @0.020 per sq.ft as per manufacturers specifications. 2nd layer of applying SBR granules mixed with rebound liquid rubber resin and water @0.17 ltrs per sq.ft as per manufacturer's specifications. 3rd layer of applying SBR granular mixed with rebound liquid rubber resin and water @0.17 ltrs per sq.ft as per manufacturer's specification. 4th and 5ty layer of applying SBR granules mixed with rebound liquid rubber resin @0.017 ltrs per sq.ft as per manufacturer's specifications. 6th layer of applying acrylic filler layer mixed with approved grade of silca sand and water @ 0.025 ltrs per sq.ft as per manufacturer's specification. 7th and 8th layer of UV resistant rebound Acrylic colour of approved shade mixed with approved grade of silica sand and water @0.022 ltrs per sq.ft as per manufacturer's specification. Application of UV protected white rebound line marking as per international standards. Product should be manufactured under ISO: 9001 2008 quality management complete all as specified and directed.
S & F Prefabricated structure, side exterior covering with 18 mm cemented water resistant Bison Panels, interior with PVC interior designer Panels, with separate glass door entry complete all as specified and directed
M & L for mapple wooden flooring with 75x35 mm mapple wooden planks with 18mm thick mapple wooden flooring with grinding, rubbing, polishing with international line markings for squash court complete all as specified and directed
S & F for 4 mm thick of size 600x600mm HSPC (high pressure Steam Cured) pre-primetered self embossed, textured designer board E-Board Classic to be fixed GI powder coated grid/section size 600mmx600mm with main runner 38x24x0.9mm thick ,cross tee 28.6x24x0.9 mm and wall angle 19x19xo.9 mm duly suspended with 2mm dia GI bar hangers 1200mm centre to centre both ways fixed with steel dash fasteners or from purling from the roof with alignment clip including providing provisions for light fixtures of any size complete all as specified and directed
S&F for pre-painted galvalume aluminum zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering /cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F for pre-painted galvalume aluminum zinc coating GI based Plain steel sheet 0.50mm thick of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed
S&F powder coating (minimum thickness pf power coating 50 micron) anodized aluminum frame for door, window, ventilators with one or more rebates including joining cleat for fixing etc complete all as specified and directed
S&F powder coating (thickness power coating not less than 50 micron) anodized aluminum door shutters aluminum section weighing 0.55kg/m including necessary joining cleats glazing clips rubber neoprene packing, handle 2 Nos in each door ,hings anodized aluminum snap beading screw lock etc complete all as specified and directed
S&F powder coating (thickness power coating not less than 50 micron) anodized aluminum window and ventilator shutters, fixed type without sash bar aluminum section weighing 0.55kg/m including necessary joining cleats glazing clips rubber neoprene packing, handle 2 Nos in each door ,hings anodized aluminum snap beading screw lock etc complete all as specified and directed
M&L for fixing 4 mm thick anodized aluminum composite panel fixed in aluminum frame including necessary rubber beading, jointing cleats complete all necessary items to fix with frame and all as specified and directed.
S&F Sheet glass 4.8mm thick clear/sun shade colour glass, ordinary quality and glazing with oil putty in squares exceeding 0.5sqm in each pane complete all as specified and directed
S&F Decorate type blinds vertical or horizontal for windows of any size & any colour, inside or outside mount, gives a neat and modern look, heat and UV reduction, made up with polyester or solid weave fabric, controlling the direction of light entering the room for blackout, dim out and sheer with all components and accessories like pulling cord, chain, plastic and iron roller blind control unit set, blind clips etc all as per manufacturers instruction complete all as specified and directed
M&L for Glazed ceramic tiles in vertical surface 350x 250x 7 mm/ 450X 350X 7mm thick set and jointed in neat cement slurry and pointed in white or colour cement to match over and including 10mm thick CM (1:4) backing coat complete all as specified and directed
S&F for Roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc confirming Fe 410 -W (Gde- E- 250) quality- A complete all as specified and directed
M & L Screed Bed or bedding layers of mortar 15 mm thick for laying floor finishes in CM 1:6 complete all as specified and directed.
S & F for 12mm thick exterior Parking tiles laid and jointed with grey cement slurry mixed with pigment in floor to match the shade of the tiles set and jointed in neat cement slurry and pointed in coloured cement complete all as specified and as directed
M&L Brick work with sub class 'B' brick, straight or curved on plan exc 6m mean radius, built in CM (1:6) complete all as specified and directed.
M&L Brick work with sub class 'B' brick, straight or curved on plan to any radius in half brick thick walls built in cement mortar 1:4 complete all as specified and directed.
M&L for 15 mm thick rendering on fair faces of brick/concrete surfaces in CM (1:4) and finished even and smooth without using extra cement all as specified & directed
M&L for complete removal of existing treatment of wall and applying two coats of interior emulsion paint with squash wall lines markings over a coat of 1mm thick wall care putty filling complete all as specified and directed.
M&L for complete removal of existing treatment of wall and applying two coats of exterior emulsion paint with squash wall lines markings over a coat of primer complete all as specified and directed.
M&L for preparation of new plastered or un plastered surface of walls including cornices, pilasters etc and applying two coats of Weather proof exterior emulsion paint over a coat of primer complete all as specified and directed.
M&L for preparation of new surfaces of steel and iron work of any description over 10 cm width or girth not otherwise described and applying two coat of synthetic enamel paint over a coat of red oxide on new surfaces in any tint complete all as specified.
S&F LED flood light 210 or higher watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp die-cast IP 66 aluminum housing , required to fix with existing bracket complete with all accessories incl taking down existing fitting complete all as specified and directed
Supply, fixing & testing in replacement of UNSV 150W LED Flood light IP66 Powder coated pressure die cast aluminum High power LED street light with heat resistant toughened glass with lens, complete with all accessories duly prewired and suitable fixing arrangement for mounting on existing MS frame/ bracket including connecting the fitting complete all as specified and directed
Supply and fixing LED luminare 600 mm x 600mm , 42 watt, 220 V AC recessed type with high efficiency PMMA diffuser soft glare free light complete with driver, holders & LED lamp suitable for roof ceiling including connecting up with driver three core flexible copper conductor cases of suitable size all as specified and directed
Excavation in trenches in any type of soil not exceeding 1.5 meter deep and not exceeding 1.5 mtr width and getting out soil including forming bottom surface to required slope/gradient for laying cables/pipes etc. including removing cable protection covers/ bricks complete all as specified and directed
Returning, filling in, including spreading leveling, watering and well ramming the excavated soil in layers not exceeding 25 cm thick complete all as specified and directed.
Removal of surplus excavated soil to a distance not exceeding 50 Mtr distance and depositing as directed at a level not exceeding 1.5 mtr above starting point complete all as specified and directed.
Material & labour for sand filling of 18 CM thick with clean dry fine sand unwashed including gently punning around cables in trenches/ducts for cable protection complete all as specified and directed
S&F for old size sub class `B` bricks, kiln burnt, as in cable protection laid flat with axis of brick perpendicular to the axis of the cable complete all as specified and directed .
Fixing / laying only old retrieved bricks of any description as obtained from dismantling of the cable complete all as specified and directed.
Disconnecting and taking out old unserviceable GI pipe and Supplying, laying & jointing GI water tubing, 50 mm bore, light grade as in sleeving etc laid in trenches / pole post etc, cutting and making necessaries arrangement by means of welding and jointing suitable for post of lantern/ street light fitting including PCC work complete all as specified and directed
Disconnecting and taking out old existing unserviceable/ non- functional LT Cable and Supplying, laying, jointing and testing cable XLPE insulated IS 7098 (Part-I)-1988 marked, screened, PVC sheathed, armored electric power cable (heavy duty) with aluminum conductor for working voltage up to and including 1100 Volts, cross sectional area of under mentioned size of cables laid in trenches/fixed on pole/wall / passed through pipe complete all as specified and directed 10 Sqmm 2 core
16 Sqmm 4 core
M&L in replacement of UNSV cross arms, bracing, supports, clamps and black plates fabricated from structural steel sections including nut, bolts and washer welding, bending cold or hot ,drilling holls for bolts in any shape or size as indicated or directed and inclusive one primer coat one under coat and one finishing coat of paints complete all as specified and directed.
Taking down old unserviceable MS junction boxes from the pole with disconnecting all connections, Supplying and fixing in position new Pole box made of thermoplastic Polycarbonate having IP65/IP66 degree of protection (shock proof, dust proof, jet water proof and acid resistive). The gasket should be internally embedded, and made of Polyeutherene. The boxes shall be tested as per IEC 60670-2/ 60670-22. The boxes shall have self threaded holes & provision for mounting din rail. The lid should be hinged type with sealing screw. The screw should be of stainless steel so that there is no corrosion. The boxes should withstand temperature of -40c to +120c. The glow wire test should be conducted at 960 c or 750 c and material should be flame retardant & self extinguishing. UL subject 94, V-0. The boxes should be free from toxic substances like hal ogen and silicon. The boxes should have suitable pre-molded knock out /or plan wall depending on requirement. Box dimension shall not be less than 200 X 160 X98 MM (LXBXH). Box shall be suitable for 16/25Sqmm cables including one no. MCB SP 230 volts 6 amps and connecting the bus bars to cables with using suitable GI nut, bolts and washers and aluminum lugs etc fixed on pole using 30x5mm FI clamps, nuts ,bolts & washers complete all as specified and directed
Material & labour of PCC 1:3:6 type C-2 using 40 mm graded stone aggregate in mass concrete and filling complete for foundation/hard standing all as specified & directed.
M & L for cutting chases in hard standing road/path/drain etc for passing cables/pipes etc. size of cutting 100mm wide and 200mm deep and removing the excavated materials and disposal at 50 meter distance and making good the cutting after the pipe and cables are laid with PCC (1:3:6) type C-1 using 20mm graded stone aggregates complete all as specified and directed.
Supplying, erecting and fixing in replacement of UNSV steel tubular swaged pole (410 SP – 31), 9 mtr long, in true vertical position complete conforming to IS : 2713 (Part-I & III) 1980 with cast iron base plate, pole cap / finial taper plug, bolts, nuts and washers, welded reduced section and longitudinal weld throughout entire length of pole with and including 2 coats of black bituminous paint externally up to planting depth and remaining exterior portion of pole finished with one coat of red oxide primer complete, all as specified and directed
M&L in replacement UNSV of sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 2.5 Sqmm of voltage rating up to and including 1100 Volts drawn in and including concealed PVC conduit (Medium grade) of suitable dia not less than 20 mm dia with standard accessories along-with one run of PVC (green colour) insulated , unsheathed, stranded copper conductor of size 1.5Sqmm as earth continuity conductor complete all as specified and directed.
S & F in replacement of unserviceable MCB 40 Amps,TP 415 volts, short circuit breaking capacity,Icn 10 kA, 'C' Curve suitable for fixing in existing MCB DB/LT Panel complete all as specified and directed.
M&L for earthing complete for bldg with galvanized mild steel earth plate electrode 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25 meters below ground level) with top edge of earth plate not less than 1.5 meters below ground level connected to galvanized earth wire 4.00 mm dia by means of nuts, bolts, thimbles, chuck nuts, washers of GI or steel, PCC (concrete chamber of size 300 mm x 300 mm x 300 mm inside dimension) shall be PCC 1:3:6 type C-1 using 20mm graded stone aggregate with fair finish , internal surface of concrete chamber shall be given 15mm thick plaster in CM 1:4, funnel with wire mesh, 80 mm thick PCC pit cover 320 mm x 320 mm of RCC 1:2:4 type B-1 using 20 mm graded stone aggregate reinforced with XPM, JALLI and charcoal dust and common salt all as shown in electrical plate No 5 of MES SSR Part-I (1991) and specified including provision of earth wire protected by 15mm dia medium grade GI pipe and watering GI pipe shall be 20mm bore medium grade etc complete, all excavation and earth work & connecting the earthing to an earthing test point main switch board as specified and testing on completion complete all as specified & directed
Material and labour for cleaning and preparation of all existing steel surfaces of straight Electric/ steel tubular poles 9/11 mtrs long for painting including mild steel cross arms, clamps and street light brackets, protection pipe, MS boxes etc and applying Two coat of aluminum paint all round the exposed steel surfaces of existing steel tubular poles of any description and in any position above the height of 1.50 mtr from the plinth of the pole and applying one coat of synthetic enameled paint of different colours in strips of 150mm width up to the height 1.5 mtr from the plinth of pole complete all as specified and directed.
G M CONSTRUCTION COMPANY
PAWAN KUMAR
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .