| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.8 LAccepted-Finance 10 SUBASH COLONY DEF LAB ROAD RATANADA JODHPUR 342006 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342006 | L1 | Accepted-Finance LOWEST | |
| 2 | L2₹6.8 L+₹115 (0.02%)Rejected-Finance H 10 KARNI NAGAR NEW NAGAUR ROAD NEAR MANDORE POLICE STATION 8TH MILL MANDORE JODHPUR 342304 | JODHPUR | JODHPUR | RAJASTHAN | 342304 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹7.9 L+₹1.2 L (17.6%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST |
Tender Value
₹9.5 L
EMD Value
₹19,000
Closing Date
30 Jun 2023, 6:00 pmClosed
AGE (I) R AND D JODHPUR
AGE (I) R AND D DEFENCE LAB JODHPUR
REPAIR AND MAINT OF VRF-III BASED AC PLANT LOCATED IN (NTC BLOCK 1 AND 2) AT DEFENCE LAB JODHPUR
2023_MES_601672_1
8553/E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
AGE (I) R AND D JODHPUR
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
AGE (I) R AND D JODHPUR
₹19,000
Yes
22 Mar 2024
7 Jun 2023
3 Jul 2023
7 Jun 2023
30 Jun 2023
16 Jun 2023
8 Jun 2023 - 15 Jun 2023
Amount
M&L for servicing of Daikin VRF-III including (outdoor and indoor) at the existing location with suitable electronic machine, cleaning of condenser, cooling coil and other components with approved chemical solution & clean water, greasing of fan, motor, blower,rewinding, assembling, testing and commissioning etc complete all as specified and directed by Engr-in-charge.
Supply and charging of gas R- 410A inside the compressor and testing Complete all as specified and as directed by Engr-in-Charge.
S&F in replacement Remote controller for indoor unit as per sample Complete all as specified and as directed by Engr-in-Charge.
S&F in replacement Battery Cell 1.5 Volt, Complete all as specified and as directed by Engr-in-Charge.
S&F in repair of Printed Circuit Board for indoor unit of any capacity available at site complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Printed Circuit Board for indoor unit of any capacity available at site complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Adopter for fixing of Printed Circuit Board in indoor unit of any capacity available at site complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of inverter PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Noise filter PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Main control PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Power/ Over Voltage PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Fan driver PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Reverse phase PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of earth leakage PCB for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Magnetic contactor for outdoor unit complete all as specified and as directed by Engr-in-Charge.
S&F in replacement of Fan motor for outdoor unit any capacity complete all as specified and as directed by Engr-in-Charge. Make - Daikin
S&F in replacement of Sheet metal encloseure with 3 pin plug and socket with 25 Amp MCB single pole. Complete all as specified and as directed by Engr-in-Charge. Make : L&T/Legrand/Schnider
S&F MCB SP 6 - 32 Amps 230 V including taking down old UNSV MCB Complete all as specified and as directed by Engr-in-Charge. Make L&T/Legrand/Schnider/Havells or any equivalent approved make
Supply and fixing MCCB 4 pole 200 Amp rotary type 415 volt breaking capacity 36 KA including taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge .Make L&T/Legrand/Schnider/Havells or any equivalent approved make
S&F MCCB 4 pole 415 volts 160 Amp rotary type breaking capacity 36 KA including taking down old UNSV MCCB Complete all as specified and as directed by Engr-in-Charge .Make L&T/Legrand/Schnider/Havells or any equivalent approved make
Supply and Fixing in replacement Scroll Fix Compressor for outdoor of any capacity as per existing size and model complete all as specified and directed by Engineer-in-charge.
Supply and Fixing in replacement inverter Compressor for outdoor of any capacity as per existing size and model complete all as specified and directed by Engineer-in-charge.
Note:- (a) One Electrician for Electric related issues in VRF system for Outdoor Main Electric panels/indoor circuits provided by contractor. (b) Material (submain wire, lugs & cable of suitable size etc.) to resolve the Electrical issue occurred on site provided by contractor itself.
Shri Electrical Enterprises
SHRI BHIKSHU ART AND CONSTRUCTION CO
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .