Loading…
Loading…
Tender Value
₹29.4 L
EMD Value
₹58,733
Closing Date
4 May 2026, 4:00 pmClosed
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
RNB ELECTRIC DIVISION KASHMIR ENGINEERING COMPLEX RAJ BAGH
Const of New Server Building at Data Center Premises Bemina, Srinagar, Infrastructure for Data Center at Srinagar B.W.O Providing 40 KVA UPS, Cabling and other allied works in new server building at KPDCL Data Centre premises PDD Complex, Bemina
2026_PWDJK_308260_1
NIT No.12//2026-27 Dt/20/04/2026
Open Tender
Electrical Works
Percentage
Bemina srinagar
Please refer Tender documents.
4 documents required · 4 mandatory
₹1,100
EXECUTIVE ENGINEER RNB ELECTRIC DIVISION KASHMIR
₹58,733
20 Apr 2026
20 Apr 2026
5 May 2026
20 Apr 2026
4 May 2026
20 Apr 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| - | SITC of on-line UPS 40 KVA 3-phase IN ,3-Phase Out with 60 minutes battery back up and isolation transformer, complete with SMF VRLA type battery bank with minimum VAH of 64000 including MS battery racks, Linksets, Battery breakers, UPS to battery bank cable. ,SNMP card with each UPS.The ups & batteries shall have comprehensive warranty of 3 years from the date of successful commissioning.The specifications are mentioned below.
Rating 4OKVA / Input Phase 3PH+N+PE,/Input voltage 3 phase-380/400/415V (selectable) /Input Frequency 45-55 Hz-55 H2 @ 50Hz, Auto sensing for 50/60 Hz, /Input power factor> 0.99/Generator Input support/ THDI <2% linear load/Rated output active power 72KW/Output voltage 3 phase-380/400/415 V (selectable)/Output power factor 0.9 leading/Outout wave form pure sine wave/Voltage variation +/- 1%/Load Crest Ratio>31/ Overload capacity 105%~110%-60 min~110%~125%-10 min~125%~150%-1'min/ Efficiency upto 94% double conversion mode/Operating temperature 0-45 deg C/Relative Humidity 0- 95%/ Noise level <55 Bm/Display LCD+ LED/Safety comply to CE/Backuptime 60 minutes (Minimum VAH-64000 for each UPS ), Make of UPS :- APC / VERTIV/BORRI /Eaton Make :- Make of batteries VRLA SMF AMARON Quanta / Exide/ Eq. make .
The Job includes providing and fixing of Phase Sequencer correction Panels for each UPS to be installed on input supplies.The Job includes CMC Contract for ups and battery banks for a period of Two years reckoned from date of sucessful handing over of site to intending departnment (The CMC Includes replacement of damaged accessories /devices by fresh one during CMC Period) | 1 | No | - | - |
| - | S/L , testing and commissioning of PVC COpper cable 650 V/1100 V Grade as per IS 7098 (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer incharge and making end termination with brass compression gland and Copper lugs of required size. | - | - | - | - |
| - | a)35 sq.mm 3.5 core ( un-armoured) | 40 | mt. | - | - |
| - | (UPS Panel) Design,Supplying,Installation,Testing and Commissioning of Cubical Type double door, indoor LT Panel Board Suitable for 415 V 3 Phase 4 Wire 50 HZ AC Supply System including Incomers,Out Goings,Bus Bars etc. as required as per the Following Description.(IP:42) General Floor Distribution Panel.The successful tenderer shall take prior approval for the panel builder/fabricator alongwith G.A. drawing, wiring diagrams, single line diagram before start of fabrication of LT panel.Circuit breaker shall be capable of carrying the full load current defined for 50 degree Celsius without any derating.The Panel Builder Shall be CPRI /ERDA/ANY NABL ACCREDITED LAB approved with latest amendments IEC-61439. Size of wiring for CTS:- 2.5 sqmm, Size of wiring for voltage sensing Metering :-4.0 Sq.mm, Size of wiring of all push buttons, indicating lamps:-1.5 Sq.mm,Types of wires:-PVC insulated 1100V grade ,Multistrand copper conductor Flexible FR-LSH, Hinged Door Earthing:-Device mounted hinged doors connected to cubicles body by means of 2.5 sqmm.green copper flexible wire, The Complete Panel Shall be Made out of 2.0 mm CRCA sheet including Frame/Partitions/Doors etc, Gland Plates to be 3.0 mm Thick. ( As per approved design,size may vary as per site requirement) | 12 | CFT | - | - |
| - | Providing and fixing of following protection equipments and other allied accessories including connections, inter connections, with suitable size of PVC insulated copper conductor cable including earthing etc. as required. | - | - | - | - |
| - | Normal INCOMING | - | - | - | - |
| - | a)160A 4P MCCB 36 KA including spreader links including spreader links, icu=ics=100% ( Adjustable thermal and Adjustable magnetic release ) Legrand/ Shinider/Semiens/ABB/ eq. make to be approved by EIC. | 1 | Nos | - | - |
| - | b) 4 No. of Aluminium Bus Bar of 200 Amp. | 1 | SET | - | - |
| - | c)Digital meters and phase indicators -1 set. | 1 | SET | - | - |
| - | OUTGOING: | - | - | - | - |
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 1.56 MB
BOQ_999175.xls
BOQ • 0.29 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .