| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹27.8 LAccepted-AOC 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹34.3 L+₹4.4 L (14.7%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹34.8 L+₹4.8 L (16.2%)Rejected-Finance 154 GANDHI MARKET AMBALA CANTT HARYANA 133001 | AMBALA CANTT | AMBALA | HARYANA | 133001 | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹34.9 L+₹5.0 L (16.8%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹35.4 L+₹5.5 L (18.4%)Rejected-Finance 303 GHS 888 SECTOR 20 PANCHKULA 134116 HARYANA | PANCHKULA | PANCHKULA | HARYANA | 134116 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹44.5 L
EMD Value
₹89,040
Closing Date
3 Aug 2020, 6:00 pmClosed
GE UTILITY AMBALA CANTT
GE UTILITY AMBALA CANTT- 133001
SPECIAL REPAIRS REPLACEMENT OF LT PANELS WITH ALLIED CABLE WORKS AT JCO OR MD ACCN AND SPECIAL REPAIRS OF HPSV HPMV FTL SECURITY PERIMETER LIGHTS INTO ENERGY EFFICIENT LED SECURITY LIGHTS ALONG WITH UG CABLES UNDER GE UTILITY AMBALA CANTT
2020_MES_354122_1
GE(U)/AMB-31/2020-21
Open Tender
Civil Works
Item Rate
240 days
AMBALA CANTT
As per tender documents
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹89,040
Yes
7 Oct 2020
6 Jul 2020
5 Aug 2020
6 Jul 2020
3 Aug 2020
20 Jul 2020
6 Jul 2020 - 19 Jul 2020
Amount
Excavation in trenches n.exc 1.5 mtr wide and n.exc 1.5 mtr deep in loose/soft soil and getting out for underground cable/erection of poles, stays etc complete al las specified and directed by Engineer-in-Charge.
Description all as per Item Ser No 1.00 above but exceeding 1.5 mtr deep but not exc 3.0mtr deep.
M & L sand cushioning for cable with river washed clean dry sharp sand and punning to provide required cover as per SSR Part I complete all as specified and as directed by Engineer-in-Charge. Note- Punned thickness shall be measured and paid to the contractor.
Supply and laying old size bricks common burnt clay sub class 'B' for cable protection to provide required cover complete all as specified and as directed by Engineer-in-Charge.
Description all as per Item Ser No 4.00 above but except bricks.
M&L PCC 1:4:8 type D-2 (using 40mm graded aggregate, mechanically crushed stone) for mass filling in pole pit and foundation etc including provision of necessary form work to achieve fair finished surfaces complete all as specified and as directed.
Material and labour Plain Cement concrete 1:3:6 type C-2 (using 20 mm graded crushed stone aggregate) for coping of poles without using extra cement all as specified and directed by Engr-in-Charge.
Returning filling in, including spreading, leveling, watering and well ramming in layers n.exc 25 cm thick layers complete all as specified and as directed by Engineer-in-Charge.
Removal of excavated material n.exc 50 mtr away and depositing where directed at a level n.exc 1.5 mtr above from starting point complete all as specified directed by Engineer-in-Charge.
Supplying and erecting ( in true vertical position) steel tubular swaged poles complete with cast iron base plate final taper plug, bolts nuts and screws all as specified of type 410-SP-31 (9.0 mtr length) complete all as specifed in IS 2713 (part-II) 1980 including one coat or red oxide primer and two coats of aluminium paint to exposed surfaces and with black bituminous paint for embedded portion of pole all as specified and directed at site. Note: Earth work and PCC shall be measured and paid for separately. (ii) Description and matter as specified and directed by Engr-in-Charge will be printed on each pole without any extra cost.
S&F Integral LED street light Luminaries (90 Watts) consisting of 18x5W HPLED/LS 18 LED mounted on MCPCB high pressure die cast aluminium housing with sealed toughened glass cover, Top opening separate driver compartment with frame, IP 66 protection suitable for pole mounting SMD led array with lense, cool white 6500 K, LED efficiency >90 lm/Watt and system efficiency 90 lm/W , 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160 V-270 V, Power factor> 0.95, working temperature range -20ºC to 60ºC,built in surge protection of more than 10kV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting , welding , drilling holes, nut bolts, washer complete all as directed by Engineer-in-charge. Note- Confirm the tests from auth labs : LM70, LM79 & LM 80.
Supply and laying, connecting and testing XLPE insulated, screened, PVC bedded, galvanized steel strip or wire armoured electrical power cable( Heavy Duty) 1100 volts grade stranded aluminium conductor of size 6 sqmm 2.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 2.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Supply and laying, connecting and testing XLPE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 10 sqmm 4.0 core laid in trenches/ on poles/ road crossing or passing through existing/new pipe under road crossing, clamping on wall etc. Note: (i) Earth work, sand, bricks , removing, returning filling Aluminium thimbles/lugs will be paid separately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates. (iii) All equipments , machinery or tools if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Description all as per Item Ser No. 14.00 here in before but for 16 Sqmm 4.0 core.
Description all as per Item Ser No. 14.00 here in before but for 25 Sqmm 4.0 core.
Description all as per Item Ser No. 14.00 here in before but for 35 Sqmm 3.5 core.
Description all as per Item Ser No. 14.00 here in before but for 50 Sqmm 3.5 core.
Description all as per Item Ser No. 14.00 here in before but for 70 Sqmm 3.5 core.
Description all as per Item Ser No. 14.00 here in before but for 95 Sqmm 3.5 core.
Description all as per Item Ser No. 14.00 here in before but for 150 Sqmm3.5 core.
Description all as per Item Ser No. 14.00 here in before but for 185 Sqmm 3.5 core.
Description all as per Item Ser No. 14.00 here in before but for 240 Sqmm 3.5 core.
Disconnecting & taking out defective underground cable any size and any type from trenches, pole, pipe, floor, wall etc complete all as directed by Engr-in charge. Note : Excavation and earth work shall be measured and paid separately here in before.
Disconnecting & taking out defective underground cable from trenches, pole, pipe, floor, wall etc and locate the fault, rectify the defect and relaying the XLPE cable underground PVC insulated and overall sheathed aluminum conductor heavy duty 1100 volts including connecting and testing for any size complete all as directed by Engineer-in-Charge. Note- Excavation/earth work & sand cushioning , bricks and joint shall be measured & paid for separately.
M&L drilling hole of any size manually as per site requirement for laying pipes under the road for crossing electrical cables complete all as per direction of Engr-in-charge. Note: Pipe will be measured & paid for separately.
Supply and fix of rigid non-metallic PVC conduit of dia 40 mm exclusive of boxes (Junction/terminal) but inclusive of all tees, bends, elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. Note : PVC pipe will be clamped at three position on pole and cost of clamp, nut, bolts etc are incl in quoted rates.
Supply and Fixing of rigid non-metallic PVC conduit of dia 25 mm exclusive of boxes (junction/terminal) but inclusive of all tees, bends elbows, reducers, bell mouth tube ends and fixing accessories such as couplers, lock nuts saddles pipe hooks etc.
Supply and fix in repair PVC street light junction box heavy duty, with locking arrangement with single phase aluminum bus bar (Make : Sintex) including 2 Nos PVC conduit up to the height of toppest level of coping from ground level, required steel fabrication work and one MCB SP 240 V, 6 Amps complete all as directed and specified.
S&F PVC insulated single core unsheathed multi stranded cable copper conductor wire 1100 volts grade of size 2.5 sq mm 2 runs for street lights and connecting with street lights and connecting with street light & MCBs after inserting into GI pipe in position complete all as directed
S & F in replacement new street light bracket made out of GI pipe light grade 40mm bore suitable to fit with LED street light approx length not less than 120cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting, welding drilling holes, nut, bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
S & F in replacement new street light bracket made out of GI pipe light grade 50mm bore suitable to fit with LED street light approx length not less than 120cm bent to shape including new clamps made of MS flat of size 40x5 mm thick including cutting, welding drilling holes, nut, bolts washers etc including two coat of aluminium paint over one coat of red oxide primer on MS work complete all as specified and as directed.
Dismantling and taking down old unserviceable earthing and Material & labour new earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable earthing and Material & labour new earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick buried directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm tor steel bars @10cm C/C both ways, 40mm bore medium grade GI protection pipe, watering pipe 20mm bore medium grade, funnel, wire mesh, also including earth work, common salt, charcoal dust complete all as specified and as directed by Engineer-in-Charge.
S & F in replacement GI tubing 80 mm bore light grade, on poles,on walls, under floors, road crossing, as required at site including fixing with suitable size MS clamps and nut bolts etc. complete all as directed by Engr-in Charge.
Description all as per Item Ser No 35.00 above but 50 mm dia.
Description all as per Item Ser No 35.00 above but 40 mm dia.
Supply and Fix in replacement Isolator/MCB 6-32 Amps, 240 volts, SP, breaking capacity 10 KA, ISI marked all as specified and directed.
Supply and Fix in replacement MCCB TPN 400 Amps , 415 Volts, 50 KA ,4 Pole, Ics=100% Icu ,overload adjustable short circuit adjustable type incl complete connection all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB TPN 250 Amps , 415 Volts, 40 KA ,4 Pole, Ics=100% Icu , overload adjustable short circuit adjustable type incl complete connection all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB TPN 160 Amps , 415 Volts, 25 KA ,4 Pole, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection all as specified and directed by Engr-in-Charge.
Supply and Fix in replacement MCCB TPN 100 Amps , 415 Volts, 16/18 KA ,4 Pole, Ics=100% Icu , overload adjustable short circuit fixed type incl complete connection all as specified and directed by Engr-in-Charge.
Taking out of Old ACB and Supply and fixing LT Air Circuit Breaker, 4 pole, manual drawout type, 415 volt with microprocessor release IPRE, 630 Amp, Icu=Ics=Icw (1s)=50 KA, neutral overload protection , inbuilt temp protection upto 90 degree Celcious, rotatable terminals for horizontal/vertical orientation, fast operation and fixing the same in existing panel board including necessary modification with angle iron and plain sheet all as directed.
Taking down old switches and S & F of Automatic street light control with infrared sensor based NATRURE SWITCH and VOLTAGE MONITORING SYSTEM (VMS) . Three phase load of 8 KW for automatic switching of street lights. Nature switch operation should be based on Natural light Lux level . Required illuminance level for switching ON is < 30 Lux and for switching OFF < 10 Lux. The sensoe should also have part night operation facility of min.4 hrs to max 12 hrs. VMS should have adjustable over & under voltage trip level and protection against phase loss, Neural loss & phase reverse incl power contractors ( 3 nos of capacity 25 Amps per phase each) and incoming ( 3 nos of capacity 32 Amps each) - outgoing MCB (3 nos of capacity 32 amps each) & main load circuit wiring (Copper) of minimum 10 Sqmm. The sensor, VSM, power contractor, MCBs incl conected items should be enclosed in a pole/wall mountable enclosure made of rust proof, electric sock proof termite proof and FR grade SMC junction box conforming to IP54. The circuit should also have provision for manual operation (i.e sensor & VMS By pass option). Model: Swadeep 02EC8KW3P - VMS /Schneider/Havells/Legrand. Make (i) Nature switch : Kakatiya Energy Systems/Healer/Bajaj (ii) Power contractor - L&T / BCH/Schneider (iii) Voltage Controlling Device - L&T or equivalent (IV) MCB- Hager/Schneider/L&T/Legrand, (v) Enclosure & circuit sheet - Sintex (shock proof , rust proof, termite proof, FR rade) (v) Circuit wiring-Polycab/Finolex Note (i)Cost of SS Nut bolts, clamp for fixing on poles/wall shall be included in quoted rates. (ii) The sensor must have the warranty of min of 2 years . (iii) The test certificate and warranty cirtificate must be provided by contractor.
Supply and fix in replacement indoor/outdoor end termination joint heat shrinkable 1100 volts for XLPE cable of size 3.5/4.0 x 10 - 50 Sqmm complete all as directed by Engr-in-Charge.
Dismantling and taking down old UNSV street light fitting and Material and labour for new LED street light fitting of 70 watt system wattage and high pressure die cast aluminium housing with sealed toughened glass cover, TOP opening separate driver compartment with frame IP 66 protection suitable for pole mounting SMD led array with lense , cool white 6500 K LED efficiency>120 lm/W and system efficiency 90 lm/W, 240 Volts AC, 50 Hz, CRI>70% operating voltage range 160V-300 V, power factor>0.95, working temperature range - 20 decree C to 60 degree C , built in surge protection of more than 9KV with facility of power supply shall be removed without removing light fitting from pole incl make proper connection complete including cutting, welding, drilling holes,SS nut bolts& washer complete all as directed by Engr-in-Charge.
S&F in replacement shock proof fire retradrant non transparent Kiosk pole box of size 310x210x120 mm made of engineering plastic on piece mounting, for out door type heavy duty, with three phase and neutral connectors suitable for connecting cable upto 95 sqmm. Suitable to house 3 nos cable with end termination joint with rail din for fixing DP MCB, incl MCB DP 6 Amp 'B' curve, fixing on steel tubular pole with the help of 02 nos clamp 20x4 mm including nuts, bolts washer etc and duly painted both side with two coats of synthetic enemel paint over a coat of red oxide primer complete all as specified and directed. Make : Universal switch gearscontrol/Schneider/Sintex/Hensel or as approved by GE.
M&L LT feeder pillar box size (1.2mX1.2mX0.6m) having thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
(a) Incomming :- (i) MCCB , 400 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 630 Amps - Set of three.
(b) Outgoing :- (i) MCCB , 200 Amps, 4P, 415V,25KA - 02 Each, (ii) MCCB, 100 Amps, 4P, 415V, 10 KA- 02 Nos.
(e) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three.
(f) CT Coils of suitable ratio -01 Set.
M&L LT feeder pillar box size (1.2mX1.2mX0.6m) having thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
(a) Incomming :- (i) MCCB , 315 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 400 Amps - Set of three.
(b) Outgoing :- (i) MCCB , 100 Amps, 4P, 415V,25KA - 03 Each, (ii) MCCB, 63 Amps, 4P, 415V, 10 KA- 01 No.
(e) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three.
(f) CT Coils of suitable ratio -01 Set.
M&L LT feeder pillar box size (1.2mX1.2mX0.6m) having thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
(a) Incomming :- (i) MCCB , 400 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 630 Amps - Set of three.
(b) Outgoing :- (i) MCCB , 200 Amps, 4P, 415V,25KA - 01 Each, (ii) MCCB, 160 Amps, 4P, 415V, 10 KA- 02 Nos (iii) MCCB, 100 Amps, 4P,10 KA -01 No
(e) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three.
(f) CT Coils of suitable ratio -01 Set.
M&L LT feeder pillar box size (1.0mX1.0mX0.6m) having thickness of 3.15mm and inner shell made out of 2mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platform 60 cm above and 45 cm below the ground level, frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body and door) lockable/open able by Keys having chromium plated 19 mm dia fancy lock, “U” type gasket shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 Volt, 50 Hz, tested at factory approved from CPRI factory fabricated having modern fabrication and testing process followed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction confirming to IS:8623/93 comprising of the following :-
(a) Incomming :- (i) MCCB , 250 Amps, 4P, 415V,35KA - 01 Each, Al busbar of capacity 315 Amps - Set of three.
(b) Outgoing :- (i) MCCB, 160 Amps, 4P, 415V, 10 KA- 01 Each, (ii) MCCB, 100 Amps, 4P,10 KA -02 Nos
(e) Indicator Lamp RYB 22.5mm dia LED type 240 volts AC with incoming includin back up protection by 2 Amp MCB RYB with holder-01 set of three.
(f) CT Coils of suitable ratio -01 Set.
Supply ,installation commissioning and testing out door type cubical panel board outer shell of size 400x400x300 mm made out of 3.15 mm thick MS sheet and inner shell made of 2 mm thick MS sheet and MS angle section 50x50x6 mm mounted on PCC 1:2:4 type B-1 platfrom 60 cm above and 45 cm below the ground level frame factory fabricated with front openable double door system and cable alloy (Each door hinged with body at 3 places with body and hinges should be welded with body abd door ) lockable/openable with arrangement of pad locking on both doors incl 2 No of pad locks of three keys shall be used to make the outer shell completely vermin proof suitable for 3 phase 4 wire 415 volts, 50 Hz, incl Aluminium bus bar of capacity 200 Amps. tested at factory approved from CPRI approved factory fabricated having modern febrication and testing process follwed by powder coat painting having thickness not less than 100 microns provided with suitable gasket to make it dust/vermin proof and general construction conforming to IS : 8623/93 including taking down old panel and comprising of the following :-
(i) Supply and fixing MCCB 100 Amps, 16 KA 4 pole 415 Volts AC, Complete all as directed by Engr-in-Charge (incoming) - 01 No
(ii) Supply and fixing MCCB 63 Amps, 16 KA 4 pole 415 Volts AC, Complete all as directed by Engr-in-Charge (Outgoing) - 01 No
(iii) Supply and fixing connected with MCCB 4 pole over voltage relay 230 V AC, U>275 V AC, 3 Phase in 1 module suitable for 3 Ph+N complete all as specified and directed by Engr-in-Charge - 01 No
(iv) RYB indication LED type 22.5 mm dia, 230 volts protected with MCB SP 2 Amp showing 3 phase supply - 03 Nos.
Notes for item Sr No. 48.00 to 52.00 (i) The quoted rate shall include minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) All internal wiring shall be done with suitable size of PVC insulated solid copper conductor FRLS cable conforming to IS-694. (iii) Panel drawing shall be got approved before placing of order from Engr-in-Charge/GE. (iv) The bus connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (v) Cable will be entered in panles through gland. (vi ) Cost of marking description and matter on the front door as specified and directed by Engr-in-Charge is incl in quoted rate. (vii) The MCCBs incorporated in these items should be adjustable type in both thermal and short circuit.
Cleaning surfaces of PCC/steel tubular poles 9 mtr long including removing old paint particles and applying one coat of cement based paint on PCC pole and aluminium paint on steel tubular pole any tint on complete pole surface and one coat of cement base paint on PCC block including one coat of aluminium paint on cross arms, bracing, supports, clamps, eye hooks, security light bracket, clamp etc and providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints on PCC pole incl repairing damaged coping and cement base paint complete all as directed. Note: (i) The quoted rate shall includes marking of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall deemed to be included the repairing of coping with cement / PCC.
Note :- Amount of credit of Rs. 2,15,620.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
Raman Electric Trading Co
Esha Engineers
Bal Singh and Sons
R D Bansal
MAHESH KUMAR SINGLA CONTRACTOR
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .