Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-Finance | ₹1.2 L | L1 | Accepted-Finance found eligible as L1 |
| 2 | L2₹3.4 LAccepted-Finance 06 THEVAR MAHAL DIGNABAD ABERDEEN VILLAGE PORT BLAIR ANDAMAN AND NICOBAR 744101 UDYAM AN 01 0000174 35ALIPK4742J1ZX B R MSME STATUS AS VERIFIED | SOUTH ANDAMANS | ANDAMAN AND NICOBAR ISLANDS | 744101 | ₹3.4 L | L2 | Accepted-Finance found eligible as L2 |
| Sl No | Description | Qty | Unit | NEW TECH ENGINEERING L2 | HARSHITHA ELECTRICAL SERVICE L1 |
|---|---|---|---|---|---|
| 1.00 | Repairing of 100 KVA, 3 Phase, 415 V Diesel Generator Set by removing of damaged stationary coil complete from the body of alternator including cleaning, rewinding of stationary coil with bare copper wire 16.5 SWG, providing with "F" Class insulation, filling-up and making good of weared armature portion, replacement of bearings etc as required complete for motor and re-assembling and commissioning of the same for testing on "No load" & "Full load" condition up to the satisfactory performance of Generator Set as directed by Engineer In-Charge. | 1 | Job | 3,35,002 ₹3.4 L | 1,18,000 ₹1.2 L |
Tender Value
₹84,013
EMD Value
₹10,000
Closing Date
23 Jan 2026, 3:00 pmClosed
Executive Engineer
Executive Engineer PHED APWD Prothrapur
Re winding of 100 KVA generator at Lambaline water treatment plant
2026_APWD_21392_1
QN/DB/PHED/2025-26/2118
Open Tender
Miscellaneous Services
30 days
Lambaline
Please refer Tender documents.
4 documents required · 4 mandatory
₹0
₹10,000
Yes
28 Jan 2026
8 Jan 2026
23 Jan 2026
8 Jan 2026
23 Jan 2026
9 Jan 2026
Repairing of 100 KVA, 3 Phase, 415 V Diesel Generator Set by removing of damaged stationary coil complete from the body of alternator including cleaning, rewinding of stationary coil with bare copper wire 16.5 SWG, providing with "F" Class insulation, filling-up and making good of weared armature portion, replacement of bearings etc as required complete for motor and re-assembling and commissioning of the same for testing on "No load" & "Full load" condition up to the satisfactory performance of Generator Set as directed by Engineer In-Charge.
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.71 MB
BOQ_22629.xls
BOQ • 0.28 MB
Download all tender documents and submit your bid