Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.6 CrAccepted-AOC G 21 MADHURA NAGAR HYDERABAD TELANGANA 500038 | HYDERABAD | TELANGANA | TELANGANA | 500038 | ₹1.6 Cr | L1 | Accepted-AOC L1 Bidder |
| 2 | L2₹1.6 Cr+₹6.1 L (3.84%)Rejected-AOC 8 34A FATHIMAPURAM TAMILNADU | TAMILNADU | ₹1.6 Cr+₹6.1 L (3.84%) | L2 | Rejected-AOC L2 Bidder |
| 3 | L3₹1.7 Cr+₹12.5 L (7.94%)Rejected-AOC 61 3134 1ST FLOOR MATHA ARCADE KSN MENON ROAD VRM ROAD JN RAVIPURAM KOCHI 682016 | KOCHI | ERNAKULAM | KERALA | 682016 | ₹1.7 Cr+₹12.5 L (7.94%) | L3 | Rejected-AOC L3 bidder |
| Sl No | Description | Qty | Unit | Fathima Engineering Co. Pvt. Ltd. L2 | ADDYUTHIYA POWER PROJECTS PRIVATE LIMITED L3 | elmech enterprises limited L1 |
|---|---|---|---|---|---|---|
| 1.00Matetrial Details | ||||||
| 1.01 | Cable End Termination Kit 11 kV XLPE 3c x 300Sq.mm -Heat Shrinkable
(Outdoor) | 13 | Nos | 2,993 ₹38,909 | 4,650 ₹60,450 | 2,400 ₹31,200 Lowest |
| 1.02 | UG Cable Route Marker HT | 60 | Nos | 400 ₹24,000 | 402 ₹24,120 | 165 ₹9,900 Lowest |
| 1.03 | 11 Kv,CC RMU, Make :Snider, gCCg,compatible with existing RMU FBX-E 12-21 155995 M+CCT2 with bus coupling kit | 3 | Nos | 4,65,760 ₹13,97,280 | 5,46,480 ₹16,39,440 | 3,80,000 ₹11,40,000 Lowest |
| 1.04 | 11 Kv,BC RMU, Make :Snider, Bus couplercompatible with existing RMU FBX-E 12-21 155995 M+CCT2 with bus coupling
kit | 3 | Nos | 4,46,625 ₹13,39,875 | 4,62,134 ₹13,86,402 | 3,55,500 ₹10,66,500 Lowest |
| 1.05 | Pipe GI 40 mm dia -2.5 m,Length( Earth Pipe) | 6 | Nos | 2,927 ₹17,562 | 1,320 ₹7,920 | 1,000 ₹6,000 Lowest |
| 1.06 | Bolt & Nut GI M 16 x 40 (11/2"x 5/8") | 10 | Kg | 148 ₹1,480 | 145 ₹1,450 | 110 ₹1,100 Lowest |
| 1.07 | Pipe GI 125 mm dia | 12 | Meter | 2,311 ₹27,732 | 2,006 ₹24,072 | 2,000 ₹24,000 Lowest |
| 1.08 | Cable Straight Joint Kit 11kV XLPE 3c x 300 Sq.mm-Heat Shrinkable (Outdoor) | 10 | Nos | 6,920 ₹69,200 | 9,576 ₹95,760 | 5,500 ₹55,000 Lowest |
| 1.09 | UG cable 11kV 3X300 mm2 XLPE Aluminium (Armoured) | 4,200 | Meter | 1,710 ₹71,82,000 | 1,680 ₹70,56,000 | 1,290 ₹54,18,000 Lowest |
Tender Value
₹1.7 Cr
EMD Value
₹50,000
Closing Date
28 Feb 2026, 5:00 pmClosed
Sudha VP
Executive Engineer, Electrical Division Kazhakuttam
Drawing a dedicated feeder to STFE complex as per request of M/S Brahmos Aerospace under Electrical Section Beach.Work code-CW-4513-202526-58
2026_KSEB_838116_1
Tender/ED-KZM/4102/2025-26
Open Tender
Electrical Works
Supply and Service
Electrical Section Beach
Please refer Tender documents.
4 documents required · 4 mandatory
₹5,900
₹50,000
14 May 2026
19 Feb 2026
4 Mar 2026
19 Feb 2026
28 Feb 2026
19 Feb 2026
Matetrial Details
Cable End Termination Kit 11 kV XLPE 3c x 300Sq.mm -Heat Shrinkable (Outdoor)
UG Cable Route Marker HT
11 Kv,CC RMU, Make :Snider, gCCg,compatible with existing RMU FBX-E 12-21 155995 M+CCT2 with bus coupling kit
11 Kv,BC RMU, Make :Snider, Bus couplercompatible with existing RMU FBX-E 12-21 155995 M+CCT2 with bus coupling kit
Pipe GI 40 mm dia -2.5 m,Length( Earth Pipe)
Bolt & Nut GI M 16 x 40 (11/2"x 5/8")
Pipe GI 125 mm dia
Cable Straight Joint Kit 11kV XLPE 3c x 300 Sq.mm-Heat Shrinkable (Outdoor)
UG cable 11kV 3X300 mm2 XLPE Aluminium (Armoured)
GI STRIP 32X6
Pipe PVC 315 mm dia 6 mm Thick -300 mm Length (PVC Earth Chamber)
RMU 11kV 630 A Bus Bar Coupling Kit
11 Kv,1C RMU, Make :Snider,FBX/12-20/C(E)/Motorized compatible with existing RMU FBX-E 12-21 170826 CT2CT2 with bus coupling kit
Earth Chamber (PVC) With RCC Covering Slab
Labour Details
Additional rate for excavating trench on tarred/concrete surface of specified size.
Doing straight joint on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sqmm using the cable jointing kit as per specification after providing proper traffic signalling and caution board fencing etc. wherever necessary, including charges for cable jointer and other for cable jointer and other sundries etc. as per the direction of departmental officers at site.
Doing one cable end termination on HT XLPE UG cables of sizes beyond 3x185 sqmm and upto and including 3x300 sq mm using the cable jointing kit after making fencing,caution board and all other safety measures including charges for cable jointer etc. complete as per the direction of the departmental officers.
Transporting Transformers by hired vehicle to a distance upto 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units excluding loading & unloading charges.
Supppplying and laying 160 mm dia 63 grade,PN-6 (wall thickness 11-12.6 HDPE pipewith coupling collars etc... in the existing trunch already made for loopin one circuit 11kv, 3 core cable through pipe for crossing radd drain channels and bridges as the drawing and specifications. with coupling collars etc... in the existing trunch alreadymade for loopin one circuit 11kv, 3 core cable through pipe for crossing radd drain channels and bridges as the drawing and specifications .
Dismantling the cable ends of all sizes upto and incl. 3x300 sqmm with special type cable clamps including connections ( Half rate of Key 934 )
Estimate is prepared for fabrication and fixing Roof for RMUs installed at beach area . For this work Alluminium sheets and double pillars of GI pipes are proposed. The double pillars are erected with concrete footing.
Providing Transformer fencing to a height of 1.8 m above ground level using MS Angle frames of size ISA 50x50x6mm for outer frame,2 runs of 40 x 6 MS flat for horizondal brasing and grills with MS rods 8 mm Dia @ 10cm c/c for verticals, providing gate with locking arrangements, providing danger board & name board, embeding the legs in cement concrete 1:2:4, footing of size 30cmx30cmx50cm, painting with synthetic enamel paint two coats over one coat of iron primer etc complete, incl cost of transportation
Transporting Transformers by hired vehicle to a distance beyond 5km and carrying upto 2 numbers of 63/100/160/250kVA Transformers / Ring Main Units (Running km) .
Cleaning and levelling of transformer yard/RMU, spreading 40 mm broken stone in yard for a thickness of 10 cm above bed of 10 cm thick 6 mm broken stone, after constructing a curb wall of height 20cm above groundand 10cm below level including cost of all materials and charges for conveying,spreading, consolidating etc.
Cement concrete 1:2:4 (1cement : 2 coarse sand :4 graded stone aggregate 20mm nominal size), having (M20) GRADE, in column base, columns etc upto plinth level excluding cost of centering, shuttering , finishing and reinforcement including cost of all materials watering, curing etc. as per the standard specifications and direction of Board staff .
Labour charges for loading LT PSC pole from the stacking place and unloading the same at work site (transportation by any vehicle).
Transporting poles by hired vehicle to a distance upto 5km and carrying upto 4 numbers of poles excluding loading& unloading charges.
Erecting one LT PSC Pole in position including digging & back filling pit in ordinary soil.
Mounting and connecting HT XLPE UG cable ends of all sizes upto and including 3x300 sq mm with special type cable clamps, bolts, nuts, terminal protectors etc.including cost of extra materials if needed and giving necessary jumper connections
Labour charges for HDD works
Cost of construction of foundation, base plates, fixing anchor bots, loading & unloading, handling, erection, allignment and allied works for the installation of Data Aquisition compatibleExtensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector, interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertaing proper phase sequence, providing location name & warning boards, burying cables & refilling, conducting all precommissioning tests as required, complete, except cost of conveyance. RMUs with two nos load break switches & one VCB allied works for the installation of Data Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector, interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertaing proper phase sequence, providing location name & warning boards, burying cables & refilling, conducting all precommissioning tests as required, complete, except cost of conveyance. RMUs with two nos load break switches & one VCB
Cost of construction of foundation, base plates, fixing anchor bots, loading & unloading, handling, erection, allignment and allied works for the nstallation of Data Aquisition compatible Extensible type Ring MainUnits with terminal protector boots & extension modules,actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertaing proper phase sequence, providing location name & warning boards, burying cables & refilling, conducting all precommissioning tests as required, complete, except cost of conveyance. RMU Bus Couplers / Add-On units with Load Break switch(s) & Earth switch i ,
Cost of construction of foundation, base plates, fixing anchor bots, loading & unloading, handling, erection, allignment and allied works for the installation of Data Aquisition compatible Extensible type Ring Main Units with terminal protector boots & extension modules, actuators for remote operatios, communicable FPIs, CTs, PTs & relay contacts for SCADA, giving power & control wiring and connections, providing terminal protector,interconnecting RMU bus bar and control cables, providing metered LT supply from nearest LT pole, providing earth leads, cable mounting & terminations, giving connections after ascertaing proper phase sequence, providing location name & warning boards, burying cables & refilling, conducting all precommissioning tests as required, complete, except cost of conveyance. Additional rate for RMUs with one additional Load Break switch / VCB.
Excavation of cable trench of appropriate size ( normally 1.2m deep and 0.35m /0.5m wide for single/double run) in all classes of soil including breaking clods, watering, ramming and sectioning of soil bank etc. and back filling the soil after cable laying and consolidating the soil in layers of 75cm (excluding laying of cable).
Laying HT XLPE UG cable of sizes beyond 3x185 sq mm and upto and including 3x300 sqmm including conveying cable from Sub Regional Store/stacking place to work site and laying it carefully using cable rollers, taking through stone ware/G.I.pipes at road crossing/culverts/bridges etc.whereever necessary, providing identification tags at 5m intervals, filling the space around the cable with riddled soil and covering the top with bricks, providing cable route markers at 100m intervals, inclusive of cost of all materials (other than cost of GI/HDPE pipe & UG Cable), labour and transport including crane charges excluding excavation and backfilling .
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.35 MB
GST-Registration-Questionnaire.pdf
Other Document • 0.52 MB
BOQ_1411734.xls
BOQ • 0.36 MB
TenderDocument.pdf
Tender Documents • 1.95 MB
Corrigendam.pdf
PDF • 0.31 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .