Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹4.8 LAccepted-Finance | L1 | Accepted-Finance responsive | |
| 2 | L2₹5.1 L+₹22,855 (4.72%)Accepted-Finance | L2 | Accepted-Finance responsive | |
| 3 | L3₹5.7 L+₹81,650 (16.9%)Accepted-Finance | L3 | Accepted-Finance responsive |
Tender Value
₹5.5 L
EMD Value
₹11,000
Closing Date
20 Jul 2022, 3:00 pmClosed
Executive Engineer
Executive Engineer ED sumbal Sonawari
Contract for Replacement of worn-Out conductor and rotten Poles at various locations within The jusrisdiction of Electric Sub-Division Hajin Electric Division Sumbal Under Capex Budget 2022-23
2022_PDD_177261_1
EDS 50 OF 2022-23
Open Tender
Electrical Works
Item Rate
hajin
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
Executive Engineer ED Sumbal
₹11,000
Yes
2 Aug 2022
2 Jul 2022
21 Jul 2022
2 Jul 2022
20 Jul 2022
2 Jul 2022
Amount
Loading from Divisional stores ,transportation to site ,installation, testing and Commissioning of ST Poles 9 Mtr long (410-SP-33) including excavation of pit and back filling soil & consolidating each deposit layer of by ramming and watering etc. (as per the latest specification and drawing approved by the department).(Poles Shall be provided by the Deptt.)
Loading from Divisional store ,transportation to site ,installation, testing and Commissioning of ST Poles 8 Mtr long (410-SP-15) including excavation of pit and back filling soil & consolidating each deposit layer of by ramming and watering etc. (as per the latest specification and drawing approved by the department).(Poles Shall be provided by the Deptt.)
Loading from Divisional store transportation to site , Laying, testing and commissioning and stringing of overhead 0.05 ACSR conductor (Rabbit) on cross arms through insulators including binding and twisting with soft aluminium wire both side of insulator complete in all respects (as per the latest specification and drawing approved by the department).(Conductor Shall be provided by the Deptt.)
Loading from Divisional store transportation to site , testing and commissioning and stringing of overhead 0.03 ACSR conductor (Weasel) on cross arms through insulators including binding and twisting with soft aluminium wire both side of insulator complete in all respects (as per the latest specification and drawing approved by the department).(Conductor Shall be provided by the Deptt.)
Providing and fixing of V -Shaped GI Cross Arms (75X40X6 mm) with top Bracket including Clamps and GI Nuts and Bolts.
Providing and Fixing of Galvanised Stay Set with 50x8mm stay clamp, guy insulator(2Nos.), anchor plate (200x 200 x 6 mm), nut-bolts, 2 Nos turn-buckles, 1.8m long, 16 mm diameter solid GS stay rod & 7/3.15 mm dia GI stranded wire complete
Providing, transportation and fixing of 11 KV Pin insulators with G.I Pins (as per the latest specification and drawing approved by the department).
Supply and fixing of GI Clamps( Muky Clamps) with LT Shackle insulators complete (GI Back Clamps to be fixed with out drilling/punching of poles) including Gi Nuts & Bolts)
Providing and fixing of HT pole Earthing Complete by GI Rod 20mm 2.5 mtr long through GI Strip
Providing and fixing of LT pole spiral earthing 125 SWG Complete (as per latest specifications and drawing adopted /approved by the department.
Painting of pole with one coat of Red-Oxide and Two coats of Aluminium paint (including cost of paint)
Supply and laying of Cement Bottoming 1:2:4 mix as per REC standards 0.5 cum/pole including muffing 20 cm above ground level plaster and curing for 9 Mtr ST poles respectively (the leftover pit after concreting to be filled with soil and boulders).
Supply and laying of Cement Bottoming 1:2:4 mix as per REC standards 0 .45 cum/pole including muffing 20 cm above ground level plaster and curing for 8 Mtr ST poles respectively (the leftover pit after concreting to be filled with soil and boulders).
Providing ,transportation ,installation, testing and Commissioning of GI Channel Cross arms 75X40X40X6 mm),fabricated out of Galvanised steel of different sizes to be fixed with GI Nuts and bolts and washers.(as per the latest specification and drawing approved by the department).
Providing & fixing of 11 kV Polymeric composite Disc insulator 12 kV,minimum failing load of 45 kN,lighting impulse of 75 kV positive & 80 kV negative and with creepage distance of 320 mm.
Providing and fixing of Galvanised Nuts and Bolts
Providing and fixing of Danger Plates with Clamps
Anti-Climbing Device with Clamps
Dismentaling of old damaged wooden/Wornout LT poles along with damaged Cross arms, Bracess & Pin Insulators and carriage of same to Divisional Store
Dismentaling of barbed/G.I/Worn out Stranded conductor and carriage of same to Divisional Store
M/s Bilal Electricals
T.N.Electrical and suppliers
tech_eval.pdf
fin_eval.pdf
finance_429076.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .