Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹17.9 LAccepted-AOC 10 MAKHAN LAL SADHUKHAN LANE PO PS BARRACKPORE KOLKATA 700120 W B | KOLKATA | NORTH 24 PARGANAS | WEST BENGAL | 700120 | L1 | Accepted-AOC Being L1 and reasonable | |
| 2 | L2₹22.1 L+₹3.7 L (20.3%)Rejected-Finance SAI VILLA C 65 EKTA NAGAR BAREILLY UTTAR PRADESH 243 122 | BAREILLY | UTTAR PRADESH | 243122 | L2 | Rejected-Finance Being other than L1 | |
| 3 | L3₹25.7 L+₹7.4 L (40.0%)Rejected-Finance SRIPUR BICHWA VILLAGE MAJRA FARM KHATIMA UDHAM SINGH NAGAR UTTARAKHAND 262308 | KHATIMA | UDHAM SINGH NAGAR | UTTARAKHAND | 262308 | L3 | Rejected-Finance Being other than L1 |
Tender Value
₹32.4 L
EMD Value
₹64,800
Closing Date
9 Oct 2024, 6:00 pmClosed
GE Pithoragarh
GE Pithoragarh Post - Bharkatiya Pithoragarh - 262520
PROVN OF OPEN FRESH SHED, PROVN OF STORE ROOM, SPL REPAIR TO BCD-37, BCD-38 (D COY), T-55 AND T-24 HEALTH SECTION AT MIL STN BANBASA.
2024_MES_673532_1
8635/PGH/E8
Open Tender
Civil Works
Item Rate
240 days
Banbasa
Please refer Tender documents.
6 documents required · 6 mandatory
₹500
GE Pithoragarh
₹64,800
Yes
7 Dec 2024
10 Sept 2024
12 Oct 2024
10 Sept 2024
9 Oct 2024
25 Sept 2024
11 Sept 2024 - 18 Sept 2024
Amount
DESCRIPTION OF ITEMS
Dismantling of AC corrugated, semi-corrugated sheets in roof coverings & ridges complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base corrugated steel sheet 0.50 mm thick trapezoidal pattern of any colour having tensile strength of 550 Mpa as in roof covering/cladding to wall, fixed with self tapping screws complete all as specified and directed.
S & F of pre-painted galvalume aluminium zinc coating GI base plain steel sheet 0.50 mm thick of any colour having tensile strength of 550 Mpa as in ridge of roof covering / cladding to wall, fixed with self tapping screws complete all as specified and directed.
Dismantling timber scantling 40 sq cm and over in framed work in any position complete all as specified and directed.
S & F of second class hard wood timber scantling clean sawn framed and fixed in any position and direction complete all as specified and directed.
S & F of rolled mild steel sections as in main and cross beams, hip and jack rafters; purlins where connected to common rafters and running rails and guides fixed with angle cleats or other connecting plates conforming to Gde Fe-410 W complete all as specified and as directed.
Dismantling of wall and ceiling boards (fibre, pulp, insulation etc) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as directed.
S & F of suspended ceiling system of grid/section of size 600x600mm comprising of interlocking GI powder coated main T-runners of size 24x38x0.33mm thick of length 3000mm, cross-T of size 24X32X0.33mm thick of length 1200mm and secondary intermediate cross-T of size 24X32X0.33mm thick of length 600mm and perimeter wall angle of size 24x24x0.40mm thick of length 3000mm to be fixed on periphery wall/partition with the help of plastic rawl plugs @ 450mm center to center and 40mm long dry wall S.S. screws with and including 4 mm thick E-board false ceiling tiles of size 595x595mm of approved texture, design and pattern to be placed in the grid system duly suspended with 6 mm dia GI wire hangers fixed with steel dash fasteners or from purlin of the roof with clip complete all as specified and directed.
Demolition of brick work /stone work built in cement mortar all as specified and directed.
M & L for brick work built in CM 1:6 with sub class old size bricks straight or curved on plan exceeding 6 m mean radius all as specified and directed.
Dismantling of floor, hearth or wall tiling including cement mortar bedding (but not backing), removing rubbish off the premises complete all as specified and directed.
M & L for joint free non-skid ceramic coloured floor tiles exc 0.11sqm but not exc. 0.18sqm as in floors set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 15mm thick screed bed in CM(1:6) complete all as specified and directed.
M & L for glazed ceramic coloured wall tiles 300x450x7 to 8mm thick as in vertical surface such as skirting/dado tiles set and jointed in neat cement slurry and pointed in white cement mixed with pigment to match the shade over and including 10mm thick rendering in CM(1:4) complete all as specified and directed.
M & L for machine cut Kota stone slab 20-25mm thick as in flooring over and including 15 mm thick screed bed in CM (1:6) laid and bedded jointed in cement slurry mixed with pigment to match to shade of the slab incuding grinding, mirror polishing complete all as specified and directed.
M & L for machine cut Kota stone slab 20-25mm thick as in riser of steps, skirting, dado and pillar over and including 10mm thick rendering in CM (1:4) laid and bedded jointed in cement slurry mixed with pigment to match to shade of the slab including rubbing & polishing complete all as specified and directed.
Demolition of cement concrete unreinforced in Ground floor & paving n.exc 15cm thickness and removal of debris from site all as specified and directed.
M & L for 75mm thick cement concrete type C2 (1:3:6) using 40mm graded stone aggregate for plinth protection, path etc finished surface even and smooth without using extra cement all as specified and directed.
Taking down cement plaster of any description in any position incl raking out joints making for key, scrubbing down with water etc and removal of debris from site all as specified and directed.
Removing old lime wash (if any), hacking for key, raking out joints of old brick work or stone work built in cement mortar; not previously plastered; and scrubbing down with water etc. to receive plaster and removal of debris from site all as specified and directed.
M & L for 15mm thick rendering in CM (1:4) on fair faces of brick work in walls and finishing the surfaces even and fair complete all as specified and directed.
M & L for 15mm thick rendering in CM (1:6) on other than fair faces of brick work in walls and finishing the surfaces even and fair complete all as specified and directed.
M & L for applying two coats of cement base paint over a coat of alkali resistant primer on walls and including preparation of surfaces complete all as specified and directed.
M & L for preparing the new surfaces of walls and applying three coats of white wash on complete all as specified and directed.
M & L for preparing the old surfaces of walls and applying one coat of white wash complete all as specified and directed.
M & L for preparation of newly plastered surfaces of walls and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
M & L for preparation of old plastered surfaces of walls by complete removal of existing treatment by brooming down or steel wire brushing, moulds, moss and efflorescent salts etc and applying two coats of oil emulsion distemper of white or tinted, over & including a layer of wall care putty (average thickness 1mm) finished smooth, complete all as specified and directed.
M & L for preparation of old painted wood and wood based surfaces of any description, not otherwise described, over 10 cm width or girth and applying one coat of synthetic enamel paint (ordinary tint) complete all as specified and directed.
M & L for preparation of new wood and wood based surfaces of any description, not otherwise described, over 10cm width or girth and applying two coats of synthetic enamel paint (ordinary tint) over a coat of pink primer complete all as specified and directed.
M & L for preparation of new steel surfaces of any description, over 10cm width or girth, not otherwise described and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
Taking down chowkhats or frames with shutter(without taking off shutter from the frame) area not exc. 1.5 sqm and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down chowkhats of any description without taking of shutter from the frame exceeding 1.5 sqm but not exc. 4.0 sqm each and making the surface of brick wall good plastering, around the opening complete all as specified and directed.
Taking down shutters of any description area not exceeding 1 sqm and removing from site all as specified and directed.
Taking down shutters of any description area exc 1 sqm and not exc 2 sqm all as specified and directed.
S & F Solid PVC door frame of size 50mm x 47mm made out of 5mm plain colour PVC sheet reinforced with mild steel square tube 47x47mm (19 gauge) all as specified and directed.
S & F factory made solid panel PVC door shutters 30 mm thick (style) consisting of frame made out of MS tube for top and bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for style and plain colour PVC sheets for top rail, lock rail and bottom rail on either sides & as gap insert for top- rail and bottom rails. Paneling of plain colour PVC sheet to be fitted in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading, and joined together with solvent cement supplying and fixing in the frame at site as per specification and drawing.
S & F of aluminium butt hinges medium weight 100mm type C-21 complete all as specified.
S & F of 150mm aluminium anodised barrel tower bolt complete all as specified.
S & F of 150mm aluminium anodised handles cast type complete all as specified.
M & L IInd class hard wood plain solid straight chowkats and frame wrought, framed rebated on the solid put together with glue, pinned at joints and fixed in position complete all as specified and directed.
S & F Mild steel Angles, bars, flats etc., as in supports for stiffening of fencing, wall ties, hold fasts, clamps and similar small articles conforming to Fe 410-O 0r Fe 310-O complete all as specified and directed.
M & L for Plain Cement Concrete 1:3:6 type C-1 (using 20mm graded stone aggregate) as in bed blocks for hold fast, coping, benching and similar work etc complete all as specified and directed.
S & F of 35 mm thick factory made flush shutters, solid core construction with block board core and plywood face panels, commercial type on both sides complete all as specified and directed.
S & F mild steel Butt hinges of medium weight and fixed 100mm all as specified and directed
S & F 150mm long extruded aluminium alloy handles, fabricated type, anodised complete all as specified and directed.
S & F 200mm long aluminium anodised, barrel tower bolts of extruded section and fixed complete all as specified and directed.
S & F 300mm long ISI marked mild steel sliding door bolts, bolt type, stove enamelled black, with bright bolt not less than 12 mm dia with and minimum of 6 bolts and nuts, four on bolt plate and two on staple plate complete all as specified and directed.
M & L for 30mm thick 2nd class hard wood glazed shutter divided into square with plain,chamfered or rounded mitered and rebated sash bar any numbers, fitted with cut and mitred beads for securing glass etc and fitted to chowkat all as specified and directed.
M & L for 35mm thick 2nd class hard wood factory made wire gauged shutter edged of frame plain chamfered or rounded fitted with cut and mitred beads for securing glass etc size of members of shutters as specified and fitted to chowkat complete all as specified and directed.
S & F 300 mm mild steel ordinary rat tail rod pattern springs including roller and roller plate complete all as specified and directed.
S & F 100mm long ISI marked mild steel barrel tower bolts, stove enamelled black with bright bolts and fixed complete all as specified and directed.
S & F 125mm long ISI marked mild steel pressed handle, oval type, stove enamelled black complete all as specified and directed.
S & F mild steel Butt hinges of medium weight and fixed 75mm all as specified and directed
S & F small fitting such as brackets, lach and hinge block shaped door and window stops and like including necessory labaours articles not exc 200 cu cm of Ist Class hardwood each all as specified and directed.
S & F sheet glass of 3mm thick ordinary quality and glazing with oil putty in square n exc 0.5sqm in each pane complete all as specified and directed.
S & F of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair of Stainless Steel wire cloth of 0.36mm nominal dia of wire and average width of aperture 1.40 mm and fixed with stainless steel wire staples complete all as specified and direceted.
S & F in repair harrison/curtain rails, mild steel, chromium plated with fixing brackets, stops, rollers etc complete all as specified and directed.
S & F in repair of vitreous china wash hand basin white flat back of size 550mm x 400mm including cutting for and pinning ends of brackets including 32mm bore PTMT waste coupling (half or full threaded) and PVC waste pipe 32mm dia and 15mm bore PVC connection 450mm long with brass union and jam nuts on both sides and fixed on a pair of MS cantilever bracket of appropriate size complete all as specified and directed.
S & F in repair of 15mm bore fancy type pillar taps, cast copper alloy, with capstan heads, chromium plated, screwed down high pressure, with or without lettered 'Hot' or 'Cold' with long screwed shanks and fly-nuts, screwed for iron pipe and fixed complete all as specified and directed.
S & F in repair of towel rail 600mm long of PTMT fixed with and including chromium plated brass screws and wooden/plastic cleats (Minimum weight 190gms) complete all as specified and directed.
S & F in repair of vitreous china squatting pan of Orissa pattern, size 580x440 mm size white with integral foot rest with Cast Iron `P' or `S' trap, front or back inlet and including connection to trap and to flushing pipe, anti-syphonage pipe etc., including trap set in and including cement concrete bedding including providing new flush pipe complete all as specified and directed.
S & F in repair of PVC low level flushing cistern 10 Litres capacity with all internal accessories and fixed to wall including 450mm long PVC connection pipe 15mm bore with brass union and jam nuts on both sides, PVC flush pipe 32mm dia fixed properly to inlet of WC complete all as specified and directed.
S & F in repair of 15mm bore bib taps fancy type, cast copper alloy chromium plated with crutch or butterfly handle, screwed down, screwed for iron pipe all as specified or as directed.
S & F in repair of 15mm bore angular stop cock fancy type, cast copper alloy chromium plated screwed down, high pressure, with crutch or butterfly handle, screwed for iron pipe or for unions and fixed complete all as specified and directed.
S & F in repair of brass chromium plated shower rose of 125mm size with or without swivel joints including fixing to steel pipe or union all as specified and directed.
Taking down GI pipes and connection including cleaning for refixing or removal to store of 15mm bore all as directed.
Taking down GI pipes and connection including cleaning for refixing or removal to store of 20mm bore all as directed.
S & F of galvanised iron tubing medium grade, with all fittings and fixed complete to wall and ceiling or laid in floors concealed where necessary bore of tube 15mm all as specified and directed.
S & F of galvanised iron tubing medium grade, with all fittings and fixed complete to wall and ceiling or laid in floors concealed where necessary bore of tube 20mm all as specified and directed.
Supplying, hoisting and fixing in repair of rotational moulded PVC water storage tank, 500 litres capacity conforming to IS-12701 (1996) cylindrical vertical type triple-layered with closed top including 20mm bore PVC float valve and necessary fittings for inlet, outlet and wash out holes complete all as specified and as directed.
Taking down rainwater pipes (any size or pattern), including all fittings heads, shoes, bends, swan-necks etc., including cleaning or refixing or removal to Store (measured over all as fixed along the centre line over fittings and accessories) complete all as specified and directed.
S & F of PVC (SWR) 110mm dia rain water pipe single socket any length with rubber rings joints fixed to walls complete all as specified and directed.
S & F of PVC (SWR) 110mm dia rain water pipe single socket any length with rubber rings joints laid in trenches or in floors complete all as specified and directed.
S & F of PVC (SWR) 110mm dia bend any radius including cutting brick wall / concrete and making good the disturbed surfaces complete all as specified and directed.
S & F PVC (SWR) 110 mm junction (Single T) equal or unequal 110mm complete all as specified and directed.
S & F of vitreous china bowl urinal flat back, size of 465 x 355 x 265 mm white (minimum), with grating and union for discharge pipe complete including providing and fixing plugs, bedding urinal against wall in cement mortar 1:2, securing urinal to plugs with and including 60 mm long brass screws, pointing around urinal back in cement mortar 1:3 including PTMT waste coupling, PVC waste pipe complete all as specified and directed.
S & F in repairs of soap dish holder CP all as specified and directed.
S & F of 125mm chromium plated grating with or without waste hole all as specified and directed.
S & F in repairs of 15mm dia PVC connection with PTMT nuts of length 450mm complete all as specified.
Surface excavation n.exc (not exceeding) 30cm deep and averaging 15cm deep and getting out in soft/loose soil complete all as specified and directed.
Excavating in trenches, not exc 1.5 m wide and not exc 1.5 m in depth, for foundation etc. or for shafts, wells, cesspits, manholes, pier holes, etc. n exc 10 sq m on plan and n exc 1.5 m in depth and getting out complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed.
M & L for removing excavated soils n exc. 50m and depositing where directed at a level n exc. 1.5m above the starting point complete all as specified and directed.
M & L for hardcore of gauge n exc. 63mm, deposited, spread and levelled in layers not exc.15cm thick, watered and rammed to a true surface complete all as specified and directed.
M & L for 75mm thick PCC 1:4:8, type D-2 (using 40 mm graded stone aggregate) as in sub base complete all as specified and directed.
M & L for PCC 1:4:8 type-D2 (using 40mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed.
M & L for 10mm thick cement plaster in CM (1:6) on other than fair surfaces of brick walls and finishing the surfaces fair and even complete all as specified and directed.
M & L for RCC 1:2:4 type B-1 (using 20 mm graded stone aggregate) as in slabs supported on walls, beams and columns in floors, roofs, landings, balconies, canopies, deck slabs and in shelves and the like complete all as specified and directed.
M & L for RCC 1:2:4 type B-0 (using 12.5 mm graded stone aggregate) as in lintels upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railings upto 60 cm in height, copings, benchings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating complete all as specified and directed.
M & L for formwork to soffits of suspended slabs such as roof slabs, floor slabs, landings and similar work; not exceeding 200mm thick (Horizontal or sloping), work in rough finished flat surfaces of concrete complete all as specified and as directed.
M & L for formwork to sides and soffits of floor or roof beams, beam haunchings, girders, bressummers, lintels, cantilevers, shelves including sup- ports, overhangs, etc. also splays between floors and beams, etc., work in rough finished surfaces of concrete complete all as specified and as directed.
M & L for formwork to edges of concrete flats, treads, breaks in floors, window cills, concrete railings, openings in concrete walls, floor and roofs n exc 20cm wide and sides of RCC/ PCC bands in walls, horizontal or sloping and similar work exc 10cm but n exc 20cm wide, work in rough finished surfaces of concrete complete all as specified and as directed.
M & L for mild steel TMT bars 10mm dia and over, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for mild steel TMT bars 8mm dia, cut to length, bent to shape required including cranking, bending spirally for hooping for columns and binding with and including mild steel wire (annealed) not less than 0.9 mm dia or securing with clips complete all as specified and directed.
M & L for 40mm thick damp proof course in cement concrete (1:2:4) type B-0 (using 12.5mm graded stone aggregate) to horizontal or vertical surfaces including necessary formwork and using water proofing compound as per manufacturer's instructions complete all as specified and directed Note : WPC shall be measured and paid separately.
Supply only liquid water proofing compound.
S & F of rolled mild steel sections as in roof trusses (framed), trussed, purlins, crane gantries, rails and fastenings and heavy bracket framing (Beam, tee, angle, channel or flat sections) including distance pieces, cleats etc. conforming to Gde Fe-410 W (Gde- E- 250) quality-A complete all as specified and as directed.
S & F of rolled mild steel works as in bands, straps, supports or stays for rainwater, hook and pintle hinges, clamps, hold fasts, wall ties, hooks for hanging fans, gusset plates, plain angle cleats for securing purlins to wood trusses or rafters and similar small articles conforming to Fe-290 Gde-E-165 complete all as specified and directed.
Providing & fixing false ceiling at all heights with semi perforated 12mm thick micro tegular edged GRG (Glass Fibre Reinforced Gypsum) false ceiling tiles of Size 595 x 595 mm of approved texture, design and patterns having moisture content less than 2%, humidity resistance of 99%, NRC 0.50 to 0.75 as per IS 8225:1987, Noncombustible as per BS 476 (part 4 )-1970 and light reflectance of 85% (minimum) to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanized iron section of 0.33mm thick (galvanized @ 120 grams per sqm including both sides) Contd......
comprising of main- T runners of size 15 x 32 mm of length 3000mm,cross-T of size 15x 32mm of length 1200mm and secondary intermediate cross-T of size 15 x 32 mm of length 600mm to form grid module of size 600x 600mm, suspended from ceiling using galvanized mild steel items (galvanizing @ 80 grams per sqm) i.e 50mm long, 8mm outer diameter M-6 dash fasteners, 6mm dia fully threaded hanger rod upto 1000mm length and Lshape level adjuster of size 85x25x2mm. Galvanised iron perimeter wall angle of size 24x 24x0.40mm of length 3000 mm to be fixed on periphery wall I partition with the help of plastic rawl plugs at 450 mm center to center and 40mm long dry wall wood screws. The work shall be carried out as per specifications, drawing and as per directions of the Engineer-in-charge.
M & L for framed work as in grills, gratings etc. with ends of bars shouldered and / or rivetted, or forged into spikes; framed guard bars; barred iron door, railings and similar work conforming to Fe 290-0 or Fe 310-0, complete all as specified and directed.
M & L IInd class hard wood plain solid straight chowkats and frame wrought, framed rebated on the solid put together with glue, pinned at joints and fixed in position complete all as specified and directed.
S & F of 25mm chromium plated curtain rod of approved quality including fixing with brackets, knobs, screws etc complete all as specified and directed.
Providing and laying 60mm thick factory made chamfered edge cement concrete paver block of M-35 grade with approved colour, design & pattern as in footparth, parks, lawns, drive ways or light traffic parking etc., of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over and including 50mm thick compacted bed of fine sand, compacting and proper embedding/ laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand complete all as specified and directed.
S & F of Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161- 1979 grade St.-240 complete all as specified and as directed.
S & F for framed work as in doors or gates of angle or other section Fe-410 Gde 250-A quality-A with gusset plates, rails braces, etc. complete drilled for fixing of steel sheeting or other covering. Doors etc shall be prepared for hanging or sliding with and including either hooks or hinges or steel hanging door fittings complete all as specified and directed.
Taking down copper /aluminium point wiring (light, fan, bell,socket or power) complete including fixture and fittings such as switches , ceiling roses , pendent , regulators, sockets, light fitting etc. Removing materials to store for keeping in safe custody or for taking credits and making good distrubed surfaces of walls, floors etc complete all as specified and directed at site.
Taking down old/unserviceable distribution board by disconnection of electric connection carefully SPN DBs/TPN DBs/ Main Switch including old unserviceable MCCBs/ MCBs, Isolators, etc and making good to disturbed surface complete all as specified and directed.
Taking down ceiling fan/ exhaust fan of any sweep after disconnecting all necessary electrical connections from ceiling rose to fan, fan blades and deposit to MES store yard complete all as specified and as directed.
M&L for point wiring with 1.5 Sq mm single core PVC insulated unsheathed copper FRLSH multi stranded conductor cable in and including Concealed PVC conduit of size 20/25mm ISI marked inclusive of tees ,bend ,elbows etc upto and including sunk in anodized pressed steel box for housing switch socket etc with white laminated 3 mm thick hylam sheet cover ISI marked of suitable size complete including PVC insulated multi stranded copper conductor 1.5 Sq mm FRLSH cable as earth wire to common earth dolly for connection to ceiling rose to earth terminal including cutting, chasses and making good disturbed surface to match with existing finish with plaster complete all as specified and directed by Engr-in-charge for following :-
(a) One light point controlled by one, one way switch 5 Amps
(b) One fan/ exhaust fanpoint controlled by one, one way switch 5 Amps and regulator
(c) One 3 pin 5 Amps switch socket outlet point controlled by one switch on the same board.
(d) One 3 pin 5 Amps switch socket outlet point controlled by one switch on independent boad.
Description all as per item No 111 here in before but using 2.5 sq mm single core copper conductor cable of multistranded flame retardant PVC insulated unsheathed 1100 volts grade for 5/15 amps switch socket cobmination point including necessary running of 2.5 sq mm copper conductor flame retardant PVC wire as earth continuity conductor along with wiring and connecting to the common eath dolly.
S & F for Switch Piano type single pole 5 amp, 230 Volts complete all as specified and directed at site.
S & F for Switch Piano type single pole 15 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 5 amp, 230 Volts complete all as specified and directed at site.
S & F for socket outlet 2 in 1 , 5 pin, 15 amp, 230 Volts complete all as specified and directed at site.
S & F for Ceiling rose, surface Bakelite with 3 terminals, ISI marked for batten fitting complete all as specified and directed.
S & F for stepped type electronic fan regulator flushType complete all as specified and directed.
S & F for lamp holder , PVC / Polycarbonate type with back plate suitabl for batten/ slanting fittings complete all as specified and directed.
S & F for sheet metal enclosure MCB DB SPN 8 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 12 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for sheet metal enclosure MCB DB SPN 4 way with 200 Amps rated bus bar 240 volts double door with magnitic locking system including necessary provision for inserting the DBs in wall by cutting the brick/stone masonary etc and making good of distrubed surface to match with existing colour of wall complete all as specified and as directed.
S & F for MCB Single pole and neutral rated capacity 40 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
S & F for MCB Single pole rated capacity 5 to 32 Amps, 240 Volts breaking capacity 10 KA, 'C' curve complete all as specified and as directed.
Fixing only for refixing the celing fan with copper conductor cable of size 23/ 0.193 from ceiling rose to fan terminal complete all as specified and as directed.
S & F for Highly efficient LED Bulbs, 10 W, used as a ready replacement for existing GLS/CFL direct fit lamp,in B-22 cap of make Bajaj, Havells, HPL complete all as specified and directed.
Supply and fixing LED lights fitting 1x 18W, 220V, AC decorative box type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose complete all as specified and directed.
S & F LED light fitting 1x9W/1X10Wbulkhead luminaires including LED light driver holder connecting up with three core flexible copper conductor cable of suitable size complete all as specified and directed.
Supply and fixing LED Bldg sec light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and directed.
Supply and fix exhaust fan, steel body AC single Phase. 230V of size 300m sweep with, blades, and frame and louvers complete all as specified and directed.
Taking down existing old Extg unserviceable LT UG/ service cable of any description and size complete all as specified and directed.
S & F XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 6 sq. mm 2 core core all as specified and directed.
Supply and laying & testing and commisioning LT underground cable of size 10 sqmm 2core, 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size complete all as specified and directed.
Supply and laying & testing and commisioning LT underground cable of size 16 sqmm 2core, 1100 volts grade, XLPE insulated and PVC sheathed heavy duty armoured with multi staranded aluminium conductor laid in pipes, trenches/ducts, on poles etc of size complete all as specified and directed.
Excavation in trenches n.exc 1.5 m wide and n.exc 1.5m in depth of trenches for laying of pipe lines and getting out including forming bottom surfaces to required level complete all as specified and directed.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm all as specified and directed.
Removing excavated material (soil) at a distance n.exc 50m and depositing where directed at a level n.exc 1.5 mtr above the starting point all as specified and directed.
M&L for providing dry sand as in cushioning to underground cable including punning down of sand in layers as specified and directed.
M&L for brick protection cover of UG cable by using old size sub class 'B''common burnt clay building bricks, laid dry and flat abutting each other with width equal to length of the brick and gap between adjacent brick n.exc 10 mm complete all as specified and directed.
S&F GI Pipe 40 mm dia light grade for protection of cable complete all as specified and directed.
Supply and fixing ceiling fans complete with blades, down rods, electronic regulator and accessories, 230 V, 1200 mm sweep. Copper binding, Min air delivery 210 CFM with service value 6.00 BEE. Five star rated with brushless direct current motor (BLDC) complete all as specified and directed.
M&L earthing complete with galvanized steel earth plate electrode 60cm x 60cm x6.0 mm thick, burried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metre below normal ground level, connected to galvanized earth lead wire 4.0mm dia Protedcted by light GI Pipe 20 mm dia and 15 dia med grade for watering pipe and connected by means of bolts, nuts, check nuts and washers of galvanized iron or steel, iron funnel,Iron pit cover and chamber all as shown in electrical plate No. 3 connected to earthing test point including testing on completion complete all as specified and directed.
Note : Tenderers may note that amount of credit Rs 48,210.50 will be deducted from the total amount arrived, at the time of Acceptance of contract.
NORTH INDIA PEST CONTROL (BID ID -3134172)
Pushkar Dutt Bhatt (BID ID -3117033)
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .