| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.2 LAccepted-Finance GROUND FLOOR C 002 PRATEEK LAUREL PLOT NO GH 01 SECTOR 120 NOIDA GAUTAM BUDDHA NAGAR UTTAR PRADESH 201307 UDYAM UP 28 0059520 | GAUTAM BUDDHA NAGAR | UTTAR PRADESH | 201307 | ₹1.2 L | L1 | Accepted-Finance L1 Bidder |
| 2 | L2₹1.6 LRejected-Finance | ₹1.6 L | L2 | Rejected-Finance Rates on are higher side |
| 3 | L3₹1.7 LRejected-Finance | ₹1.7 L | L3 | Rejected-Finance Rates on are higher side |
| Sl No | Description | Qty | Unit | U K S ENTERPRISES | Neelkanth Construction | SANA AND COMPANY |
|---|---|---|---|---|---|---|
| 1.00Laying and Jointing PVC Pipe. Heading | ||||||
| 1.01 | Distamatling and Erection of 220 kV Line Feeder panel of 220 kV Rasra(400 kV) Bay at 220 kV S/S,Rasra under ETD-Ballia
Shifting of 01 no 220 kV Line feeder panel from the store to KOISK with the help of manual labour/crane at 220 kV S/S Rasra alongwith other associated work with all cost of men,material and T&P etc required for satisfactory completion of work in the direction of supervising engineer. | 1 | Job | 3,000 ₹3,540 | 2,650 ₹3,127 | 4,000 ₹4,720 |
| 1.02 | Dismanteling of existing 01 no. ZIV make SAS based make 220 kV Rasra(400 kV)-Rasra(220 kV) line bay protection panel by disconnecting all control cables, AC cables, DC cables, CT & PT cables etc. and cutting of earthing strips including shifting of dismantled protection panel from control room to substation store. | 1 | Job | 8,000 ₹9,440 | 7,000 ₹8,260 | 5,000 ₹5,900 |
| 1.03 | Erection of new ASHIDA make 220 kV Line protection pannel at above dismantled place with proper alignment as per direction of incharge engineer and making earthing by MS flat (25X6mm/50X6mm) with existing earthmat as per site requirement. | 1 | Job | 6,500 ₹7,670 | 6,200 ₹7,316 | 5,480 ₹6,466.40 |
| 1.04 | Termination of all control cables, AC cables DC cables, CT & PT cables etc. alongwith proper ferruling and fastning of cable glands of actual size of above protection pannel (Cable glands,lugs and ferrules etc. shall be arranged by contractor at his own cost.) All associated works must be completed as per technical specification & Schematic drawing. | 1 | Job | 13,500 ₹15,930 | 12,000 ₹14,160 | 6,000 ₹7,080 |
| 1.05 | Checking of heathiness of all wires by checking supervision circuit,closing and tripping circuit,alarm and indication circuit,CT & PT circuit etc.Completed job in all respect. | 1 | Job | 7,000 ₹8,260 | 6,200 ₹7,316 | 6,501 ₹7,671.18 |
| 1.06 | Distamatling and Erection of 220 kV Transformer Relay & Control panel of 160 MVA,220/132 kV ICT-I at 220 kV S/S,Rasra under ETD-Ballia
Shifting of 02 no 220 kV C&R panel from the store to KOISK with the help of manual labour/crane at 220 kV S/S Rasra alongwith other associated work with all cost of men,material and T&P etc required for satisfactory completion of work in the direction of supervising engineer. | 2 | Job | 6,000 ₹7,080 | 5,400 ₹6,372 | 8,000 ₹9,440 |
| 1.07 | Dismanteling of existing 02 no. ZIV make SAS based make 160 MVA Control & Relay panel by disconnecting all control cables, AC cables, DC cables, CT & PT cables etc. and cutting of earthing strips including shifting of dismantled protection pannel from control room to substation store. | 2 | Job | 14,000 ₹16,520 | 14,200 ₹16,756 | 8,000 ₹9,440 |
| 1.08 | Erection of new ASHIDA make 160 MVA Control & Relay panel at above dismantled place with proper alignment as per direction of incharge engineer and making earthing by MS flat (25X6mm/50X6mm) with
existing earthmat as per site requirement. | 2 | Job | 13,000 ₹15,340 | 12,400 ₹14,632 | 8,000 ₹9,440 |
| 1.09 | Termination of all control cables, AC cables DC cables, CT & PT cables etc. alongwith proper ferruling and fastning of cable glands of actual size of above protection pannels (Cable glands,lugs and ferrules etc. shall be arranged by contractor at his own cost.) All associated works must be completed as per technical specification & Schematic drawing. | 2 | Job | 27,000 ₹31,860 | 26,000 ₹30,680 | 11,300 ₹13,334 |
Tender Value
Refer Docs
EMD Value
₹2,000
Closing Date
1 Dec 2025, 1:00 pmClosed
EXECUTIVE ENGINEER
CIVIL LINE ELECTRICITY TRANSMISSION DIVISION BALLIA
WORK FOR THE DISMANTALING AND INSTALLATION OF 220 KV AND 132 KV LINE AND TRANSFORMER C AND R PANEL AT 220 KV SS RASARA AND 132 KV SS BALLIA UNDER ETD BALLIA
2025_UPTCL_1091663_1
05/ETDB/2025-26
Open Tender
Electrical Works
60 days
ELECTRICITY TRANSMISSION DIVISION BALLIA
Please refer Tender documents.
2 documents required · 2 mandatory
₹590
EE ETD BALLIA
₹2,000
18 Dec 2025
18 Nov 2025
2 Dec 2025
18 Nov 2025
1 Dec 2025
18 Nov 2025
18 Nov 2025 - 1 Dec 2025
Laying and Jointing PVC Pipe. Heading
Distamatling and Erection of 220 kV Line Feeder panel of 220 kV Rasra(400 kV) Bay at 220 kV S/S,Rasra under ETD-Ballia Shifting of 01 no 220 kV Line feeder panel from the store to KOISK with the help of manual labour/crane at 220 kV S/S Rasra alongwith other associated work with all cost of men,material and T&P etc required for satisfactory completion of work in the direction of supervising engineer.
Dismanteling of existing 01 no. ZIV make SAS based make 220 kV Rasra(400 kV)-Rasra(220 kV) line bay protection panel by disconnecting all control cables, AC cables, DC cables, CT & PT cables etc. and cutting of earthing strips including shifting of dismantled protection panel from control room to substation store.
Erection of new ASHIDA make 220 kV Line protection pannel at above dismantled place with proper alignment as per direction of incharge engineer and making earthing by MS flat (25X6mm/50X6mm) with existing earthmat as per site requirement.
Termination of all control cables, AC cables DC cables, CT & PT cables etc. alongwith proper ferruling and fastning of cable glands of actual size of above protection pannel (Cable glands,lugs and ferrules etc. shall be arranged by contractor at his own cost.) All associated works must be completed as per technical specification & Schematic drawing.
Checking of heathiness of all wires by checking supervision circuit,closing and tripping circuit,alarm and indication circuit,CT & PT circuit etc.Completed job in all respect.
Distamatling and Erection of 220 kV Transformer Relay & Control panel of 160 MVA,220/132 kV ICT-I at 220 kV S/S,Rasra under ETD-Ballia Shifting of 02 no 220 kV C&R panel from the store to KOISK with the help of manual labour/crane at 220 kV S/S Rasra alongwith other associated work with all cost of men,material and T&P etc required for satisfactory completion of work in the direction of supervising engineer.
Dismanteling of existing 02 no. ZIV make SAS based make 160 MVA Control & Relay panel by disconnecting all control cables, AC cables, DC cables, CT & PT cables etc. and cutting of earthing strips including shifting of dismantled protection pannel from control room to substation store.
Erection of new ASHIDA make 160 MVA Control & Relay panel at above dismantled place with proper alignment as per direction of incharge engineer and making earthing by MS flat (25X6mm/50X6mm) with existing earthmat as per site requirement.
Termination of all control cables, AC cables DC cables, CT & PT cables etc. alongwith proper ferruling and fastning of cable glands of actual size of above protection pannels (Cable glands,lugs and ferrules etc. shall be arranged by contractor at his own cost.) All associated works must be completed as per technical specification & Schematic drawing.
Checking of heathiness of all wires by checking supervision circuit,closing and tripping circuit, alarm and indication circuit,CT & PT circuit etc.Complete job in all respect.
Distamatling and Erection of 132 kV Line feeder panel of 132 kV Chitbaragaon Bay at 132 kV S/S,Ballia under ETD-Ballia Carriage of 132KV line protection panel from 220 KV S/S Rasara to 132KV S/S Ballia
Dismantling of 132KV old and defective relay distance protection panel (M/S ABB make ) of 132KV Chitabaragoan bay by disconnecting all control cable AC cabel, DC cable ,CT&PT cable,Protection cable etc. and cutting of earthing strip including shifting of dismantled distance protection from control room to substation store.
Shifting of M/S Siemens make 132KV distance protection panel from S/S store to control room safely & carefully by manual labour at place instructed by incharge engineer ( approximate distance 50.00 meter).Grouting also to done if required .
Erection of new M/S Siemens make 132KV distance protection panel at above dismantled place as per proper alignment and direction of AE/JE with making earthing by M.S flate (25x6 mm /50x6 mm ) as per site requirement .
Termination of all control cable AC cable, DC cable, CT&PT cable ,Protection cable alongwith proper feruling and fastening of cable glands of proper size of above distance protction panel .Cable glands & ferrules etc. shall be arranged by contractor at his own cost.All associated works must be completed as per technical specification & schematic drawing
Checking of healthiness of all wire by checking supervision circuit closoing and tripping circuit , alarm and indication circuit , CT&PT circuit etc complete job in all respect
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.91 MB
tender.pdf
Tender Documents • 1.19 MB
BOQ_2005511.xls
BOQ • 0.30 MB
Download all tender documents and submit your bid