Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹28.7 LAccepted-AOC 4578 STREET 15 15A AGGARWAL ROAD DARYAGANJ CENTRAL DELHI DELHI 110002 UDYAM DL 01 0031798 | CENTRAL DELHI | DELHI | 110002 | L1 | Accepted-AOC LOWEST | |
| 2 | L2₹31.6 L+₹2.6 L (9.10%)Rejected-AOC 362 SUBHASH NAGAR PO CLEMENT TOWN DEHRADUN UTTARAKHAND | L2 | Rejected-AOC NOT OWEST | |
| 3 | L3₹32.0 L+₹3.1 L (10.6%)Rejected-AOC 00 VILL RATI KA NAGLA SIKANDRA RAO ROAD INDUSTRIAL HATHRAS UTTAR PRADESH 204212 | HATHRAS | UTTAR PRADESH | 204212 | L3 | Rejected-AOC NOT LOWEST |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
30 Dec 2021, 6:00 pmClosed
CWE(HILLS) DEHRADUN
Headquarters Commander Works Engineers (Hills) Military Engineer Services, Mall Road, Dehradun Cantt
REPAIR MAINT OF HT LINES HT CABLES VCBs RMU SHIFTING OF POLES AND RATIONALISATION OF HT SYSTEM AND ITS CONNECTED ITEMS UNDER GE CLEMENT TOWN DEHRADUN.
2021_MES_492613_1
85344/CLT/E8
Open Tender
Electrical and Maintenance Works
Item Rate
270 days
GE Clement town
Class D Cat b ii
6 documents required · 6 mandatory
₹500
GE Clement Town
₹80,000
Yes
14 Jan 2022
4 Dec 2021
1 Jan 2022
4 Dec 2021
30 Dec 2021
18 Dec 2021
4 Dec 2021 - 7 Dec 2021
Amount
Dismantling cross arm of MS channel or angle section etc complete and setting aside within 50m for further disposal complete all as specified and directed.
S & F Anti climbing devices spikes type fabricated out of M.S. bars (round, square and flat) including nuts, bolts washers and welding in two halves made to shape to suit the cross section of the pole complete all as specified and directed
S&F Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size for HT 25x20 cm size complete all as specified and directed.
S&F Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size for 11 KV size 25 x 20 cm size complete all as specified and directed.
S&F Danger notice plate of 1.6 mm thick mild steel sheet vitreous enamelled white with letters figures and conventional skull and bones in signal red colour and fixed with M.S. Clamps, bolts and nuts of approved size for 33 KV size 30 x 22 cm size complete all as specified and directed.
M&L for cross arms,bracings,supports,clamps and back plates fabricated from structural steel sections including nuts,bolts,washers welding,bending cold or hot drilling holes for bolts in any shape or size as indicated or directed including of one primer coat,one under coat and one finishing coat and one finishing coat of paint.
Supply and fixing in replacement galvanised iron earth wire 4.0 mm dia size for streaching on over head lines as earth continuity conductor including binding at ends with aluminium / steel binding wire at the places where complete all as specified and directed.
Taking down old unserviceable Overhead ACSR Conductor of any size complete all as specified and directed by Engineer-in -charge . (Note:- 3 Nos of ACSR Conductor in Each RM)
Supply, laying, connecting and testing in XLPE insulated, screened, PVC bedded,galvanised steel strip armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts grade( E) cross sectional area 95 sq mm 3 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed by engineer-in-charge.
Supply, laying, connecting and testing in XLPE insulated, screened, PVC bedded,galvanised steel strip armoured,electric power cables (heavyduty) with aluminium conductor, 11000 volts grade (E) cross sectional area 120 sq mm 3 core ISI marked laid in cable duct/trenches/surface/wall complete all as specified and directed.
Excavation in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth for poles, laying of electric under ground cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all specified and directed.
M&L for fine dry sand cushioning for under ground cable by providing layers of sand 8 cm deep before laying and 15cm deep after laying the cableincluding streching the cable complete all as specified and directed. Note :- Punned (consolidated) thickness of sand will be measured and paid.
M&L for un -reinforced precast concrete cable cover class HVP, type 1 ISI marked with peak , flat of size 300mmx180mm x 40mm as cable protection complete all as specified and directed.
Returning , filling in, any type of soil including spreading, leveling, watering and well ramming in layers n.exc 250mm thick, complete all as specified and directed.
Removing excavated material (surplus soil) to a distance not exceeding 50m and depositing where directed at a level n.exc 1.5 m above the starting point, complete all as specified and directed.
M&L for PCC/ road cutting for laying of pipe/cable exceeding 500 Sqcm & not exc 1000 sqcm in cross sectional area and making good with PCC 1:2:4 type B-1 using 20mm graded stone aggragate, complete all as specified and directed.
NOTE: (i)Cost of all the material , components, repairs, elements as per above as well as other elements (except supply only of the components considerd under items herein after to the extent required and operated ) to make the VCB,s/RMUs/SF6 CB complete functional shall be deemed to be included in the quoted rate of the contractor.
(ii)Individual Breaker SF6/VCB/OCB/RMUs consider as one unit and above job is to be carried out unitwise.Above job will be carried out by licenced technician as aproved by GE.
(iii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor.
(iv) All necessary tools & plants required for carried out above job will be provided by contractor and the cost of the same are deemed to be included in queoted rate.
(v) Inventry of defective parts to be replaced by contractor will be prepared by joint inspection with contractor
M & L for calibration IDMT miscroprocessor based numeric relay (Three nos overcurent and one no earth fault relay) fixed in 11 KV/33 KV HT panel by primary and secondary injection method and setting the relay tripping timing in advance to match the outgoing load on the incoming and out going feeders complete all as specified and directed
Note :(i)Individual Breaker SF6/VCB/RMUs consider as one unit and above job is to be carried out unitwise.Above job wii be carried out by licenced technician as aproved by GE.
(ii) Any accident/mishapenning occurred during the execution of work shall be responsibity of Contractor.
(iii) All necessary tools & plants required to carriy out above job will be provided by contractor and the cost of the same deemed to be included in queoted rate.
Supply, install, testing and commissioning of microprocessor based numeric feeder protection relay ( over current three nos and earth fault one no)with low set, high set testing, type Make; REF 615 of ABB or equivalent in L&T /Simense for 33/ 11 KV HT panel incl taking down old u/s relay complete all as specified & directed.
Supply & replacement of Silica Gel crystal complete in breather assembly of any type and any capacity transformers complete all as specified & directed.
Supply, install, testing and commissioning of winding temperature indicator meter range 0-120 0 C for 3.15 MVA 33/11 KV power transformer” incl taking out complete all as specified & directed.
Supply, install, testing and commissioning of oil temperature indicator meter range 0-120 0 C for 3.15 MVA 33/11 KV power transforme incl taking out complete all as specified & directed.
Taking out old U/S control cable any size complete all as specified & directed.
Supply and laying of copper cable of size 2.5 Sqmm x 5 core from 33 KV power house to Yard for control wiring with SMC/FRP junction box as per required at site complete all as specified & directed.
M&L for PVC insulated single core, un armoured aluminium conductor of size 35 Sqmm 1100 volt grade of red, yellow, blue and black (phase indication) for jumper connections including taking out U/S Jumper cable any size complete all as specified and directed.
Supply, installation, commissioning and testing of HT 11 KV outdoor type gang operated triple pole air break switch suitable for verticle mounting fixed type complete with 12 insulators 200 amps rating and steel frame mechanically operated mechanism consinting of operating rod 25mm bore light grade GI pipe of suitable length worked from ground level and with locking arrangement flat iron clamp 50mm x6 mm including MS channel of suitable size and length for fixing GOD including bolts, nuts and washers as in repair complete all as specified as directed.
S&F in replacement triple pole drop out expulsion fuse unit out door type suitable for 33 KV system current rating 400 amps mounted on insulator and steel frame complete with heavy tinned non ferrus metal spring load copper contact silver/tion plated at contact points complete all as specfied and ditrected.
Supply ,installation ,testing and commissioning as in repair of lighting arrester metal oxide type, distribution class with all fittings arrangements suitable to 11000 volts grade and discharge capacity 12 KV/10 KA with and including lighting counter and cable of suitable size and core from lightning arrester to lighting counter complete all as specified & directed Make : Jaipuriya brothers/ Crompton/ GEC/ BHEL/ATLAS
Supply ,installation ,testing and commissioning as in repair of lighting arrester metal oxide type, distribution class with all fittings arrangements suitable to 33000 volts grade and discharge capacity 36 KV/18 KA with and including lighting counter and cable of suitable size and core from lightning arrester to lighting counter complete all as specified & directed Make : Jaipuriya brothers/ Crompton/ GEC/ BHEL/ATLAS
Material and labour for testing of Bucholz relay ,winding temprature & Oil temprature Protection relay unit complete along with control wiring for its functioning including, alarm in case any defects noticed the same will be rectifeid by the contractor without any extra cost. Note :- All necessary tools & plants required to carring out above job will be provided by contractor and the cost of the same are deemed to be included in queoted rate.
S & F PG clamp suitable for any size of ACSR conductor complete all as specified and directed.
Fault ditection of 11 KV U/G cable of any size 3 core with the help of automatic fault locating machine, including route tracing with the help of route tracer Note :The cost for any type of soil like excavation, any type of earth work, cutting of branches and bushes at site are deemed to be included in Queoted rate complete.
M&L for punning of tree, branches touching to electric overhead lines with growth around LT/HT over head lines , poles and stay complete to clear span of 2 mtr all around the OH line , poles with all tools and plants as reuired at site by the contractor including cleaning the area / site ( Note: Any breakdown of line caused during punning shall be made good by the contractor without any extra cost ( ii ) Distance between pole to pole shall be measured as one span) (iii) Only those span will be measured in which trees are alives.
M & L for applying two coats of synthetic enamel paint of approved quality / Shade including preparation of existing old painted surface of feeder pillar box/LT panel complete all as specified and directed.
Supply, install and commissioning in replacement of gear box and charging motor 110 volt suitable for HT 33 KV outdoor VCB, AC 3 phase, 50 HZ complete all as specified and directed by Engr-in-Charge Make of VCB-ABB
Supply only of following items suitable for HT VCB 11 KV/33 KV /RMU, AC 3 Phase, 50 Hz , complete all as specified and directed and as per existing Make .
Vaccume bottle type VG 2 of 11 KV VCB trolly rating 350 MVA ,current rating 800 amps of make ABB/Siemens
Single phase circuit Spout RYB phase of make ABB/SIEMENS/SCHNIDER
Single pahse bus bar spout for R and B phase of Make ABB/SIEMENS/SCHNIDER
Single pahse bus bar spout for Y phase of Make ABB/SIEMENS/SCHNIDER
Copper flexible connection 800 amps capacity suitable for VG 2 VCB trolly of Make ABB/SIEMENS/SCHNIDER
Closing coil operating on 110 Volts DC for VCB trolly of Make ABB/SIEMENS/SCHNIDER
Tripping coil alongwith plunger operating on110 Volt DC for VCB trolly of Make ABB/SIEMENS/SCHNIDER
Insulator for Bus bar support of Make ABB/SIEMENS/SCHNIDER
Buffer for opening spring of Make ABB/SIEMENS/SCHNIDER
Buffer for Closing spring of Make ABB/SIEMENS/SCHNIDER
Auxiliary switch.
Limit switch.
Auxiliary contactor.
Closing coil alonwith plunger operating on 36 Volts DC for VCB trolly of Make ABB/SIEMENS/SCHNIDER
Tripping lever
Triping lever clutch
Master trip relay type VAJ 110 volts Make :L&T/Schinder/ABB/AREVA
Supply only HT fuse wire made out of tinned copper suitable for 11 KV feeder of rating 15 amp. complete all as specified and directed.
Supply only insulation tape(empire tape) of best quality insulation class A, dry, non adhensive,tensile strength not less than 38 lbs/inch 25mm x 15 mtr ISI Marked. complete all as specified and directed.
M&L 100 mm dia bore tube light grade GI laid under road / culvert / drain fixed to pole wall with help of flat iron clamps duly painted etc for cable protection . Complete all as specified and directed.
S&F cable jointing kit 11 KV (Earthed) grade cable for outdoor termination cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminum conductor cabe of size 50 to 95 sqmm , complete all as specfied and directed.
All as per item No 40 above but of size 120 to 185 Sqmm.
All as per item No 40 above but indoor type of size 50 to 95 Sqmm.
All as per item No 40 above but indoor type of size 120 to 185 sqmm.
S&F cable jointing kit 11 KV (Earthed) grade cable for straight through cold shrinkable type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 95 Sqmm, complete all as specified and directed.
All as per item No 44 above but of size 120 to 185 Sqmm.
S&F Supplying and laying synthetic Rubber insulated mats 2.5 mm thick (Elastomer free from , dotted desgin, Tensile strength 15N/mm2) for voltage upto 11 kv for electrical purpose as per IS 15652-2006, (ISI Marked ) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. Make : Duratuf/ Jaipurya brothers
S&F Supplying and laying synthetic Rubber insulated mats 3.0 mm thick (Elastomer free from , dotted desgin, Tensile strength 15N/mm2) for voltage upto 33KV for electrical purpose as per IS 15652-2006, (ISI Marked ) suitable for electrical shock safety of sizes 2m x 1m complete all as specified and directed. Make : Duratuf/ Jaipurya brothers
S&F Mild steel plates, chequered, 6mm thick or over in thickness of FE -410-W(Gde-E-250) Quality -A of approved size as directed by AGE/GE complete all as specified and directed.Note :- Perforatons shall be made in MS sheet of size 10 mm to 12 mm dia at spacing 100 mm c/c or as dircted by Enginner-in -charge ) inclding necessary provision of Handles
Supply, installation, testing and commissioning single phase input supply, Single phase output, PWM technology IGBT based ON_LINE battery charger for standard maintenance free (SMF) battery bank with features of protection incase of High and Low voltage etc of capacity not less than 5 KVA of rating 20 Amps at 110 Volts all as specified and directed. (Make:- Sinetrac/Voltstat/ SCS complete all as specified and directed.
Supply, transporting, erection and fixing steel tubular swaged pole, 11 metres long, type 410 SP-55, complete with MS base plate 6 mm thick, pole cap, finial taper plug, bolts, nuts, washers etc including necessary earth work and excavation, PCC in foundation 1:4:8 type D-2, using 40 mm graded stone aggregate and PCC 1:3:6 type C-2, using 40 mm graded stone aggregate as in plinth block, disposal of surplus soil to a distance not exceeding 50 m, painting two coats of aluminium paint over one coat of red oxide primer including 3 Nos band/straps with red post office box colour (300mm wide each) synthetic enamelled paint at a distance 300mm from plinth block and marking pole nos with black synthetic enamelled paint including tarring one coat on steel surface embedded in concrete complete all as specified and directed.
KAPOOR ELECTRICALS
M/S VIJAY SINGH
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .