| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹23.0 LAccepted-AOC | L1 | Accepted-AOC Acceptance of contract | |
| 2 | L2₹31.1 L+₹7.3 L (30.4%)Rejected-AOC SHOP NO 5 OPP SHANI MANDIR PROFESSOR COLONY DISTT YAMUNA NAGAR HARYANA 135001 | YAMUNANAGAR | HARYANA | 135001 | L2 | Rejected-AOC R | |
| 3 | L3₹32 L+₹8.1 L (34.0%)Rejected-AOC WING NO 7 2 10 PREMNAGAR DEHRADUN UK | L3 | Rejected-AOC R | |
| 4 | L4₹32.5 L+₹8.6 L (36.0%)Rejected-AOC | L4 | Rejected-AOC R | |
| 5 | L5₹32.5 L+₹8.7 L (36.3%)Rejected-AOC H NO 206 RAJAPUR DUJANIA MOHALLA DASNA DEHAT VILLAGE TOWN INDERGARHI CITY GHAZIABAD GHAZIABAD UTTAR PRADESH 201002 INDIA | GHAZIABAD | UTTAR PRADESH | 201002 | L5 | Rejected-AOC R |
Tender Value
₹40 L
EMD Value
₹80,000
Closing Date
18 Jul 2023, 6:00 pmClosed
GE IMA Dehradun
GE IMA Dehradun
REPAIR AND MAINTENANCE OF INTERNAL ELECTRIFICATION FITTING AND FIXTURE IN TAB VB MESS MD ACCN AT MT COLONY AT SOUTH COMPLEX UNDER GE IMA DEHRADUN
2023_MES_606200_1
GE/IMA/T-47 of 2023-2024 9341/E8
Open Tender
Support/Maintenance Service
Item Rate
180 days
GE IMA Dehradun
Refer NIT
8 documents required · 8 mandatory
₹500
Yes
GE IMA Dehradun
₹80,000
Yes
14 Sept 2023
27 Jun 2023
20 Jul 2023
28 Jun 2023
18 Jul 2023
11 Jul 2023
Amount
Taking down carefully existing aluminum/copper surface/concealed point wiring (light, fan, socket or power point) complete of any description including fitting such as switches, ceiling roses, regulators, sockets, wooden boards, laminated sheets from sunken boxes, boards, holders and making good the disturbed surfaces in cement mortar 1:3 of walls, floors, ceiling etc including distempering to match with existing surfaces complete all as specified and directed. Important Notes for all items 1 The contract site mainly comprises of OTMs where point wiring may exceed its standard length, Hence the contractor is advised to visit the site and quote rate accordingly because there will be no additional payment for longer point wirings. 2. The standard safety equipments to electricians / helpers will be provided by the Contractor without any additional cost to the department . 3. Tools and plants should be provided by the Contactor to the worker without any extra cost to the dept. 4. The contractor will make good of disturbed surfaces with whatever material required to matchup with existing surfaces without any additional cost to the dept. This condition applies to all the materials in the BOQ. 5. Point wiring & earth wire shall be connected to each & every sunken box. 6. The fittings and fixtures should be fixed in proffessional manner i.e, the position as well as technical things such as earthing connections , wire connections , connecting and disconnecting and whatever misc things required for efficient and safe operation of fittings snd fixtures is lookout of Contractor without any additional cost to the dept. The material required for the same such as 2 core 1.5 sq mm wire or 3 core 1.5 sq mm wire or flexiblke wire or nuts, bolts, washers, lugs, thimbles, Insulation tape etc are deeemed to be included in the rates of respective items. 7. The technical parameters of every item has been highlighted to grab the attention of Contractors so that discrepiencies can be avoided at a latter stage, Hence Contractor are advised to quote rate after strong market research. 8. If any discriepancy is arised during the execution of Contract, the decision of Engineer-in-Charge shall be final and binding. 9. The electrical equipments such as Ceiling Fan, Exhaust Fan, Water Heater, Air Conditioner,Deep Freezer, Refrigerator, Desert cooler , Water Cooler, Water Purifiers, Kitchen Equipments etc Should be as per latest Electrical Energy Efficiency norms and 5 star ratings ( where applicable). 10. The Contractor has to prepare Inventory of Wiring Location detailed and wiring test sheet as per format given
Material and labour for point wiring with PVC insulated and unsheathed electric able 1100 volts grade single core FRLSH having multi stranded copper conductor of 1.5 Sq mm nominal cross sectional area drawn in and including concealed / surface non metallic rigid PVC conduit not less than 25 mm dia with all fitting and fixing accessories and 1.5 sq mm PVC insulated unsheathed multistranded copper conductor cable as continuous earth conductor, connected to earth dolly by providing suitable lugs with & including pressed steel sunken terminal boxes 1.6 mm thick, 60 mm deep of required size factory made for mounting switch, regulators etc with and including 3 mm thick plastic hylam laminated sheet cover (white) ISI marked, fixed with brass screws and cup washers duly painted with two coats of anti corrosive paint/black bituminous paint outside and two coats of aluminium paint inside for mounting switches, sockets etc complete for the following. Make of wire:Havells/ Polyacab /Anchor Make of conduit: AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab Notes (i) The quoted rates shall be deemed to be inclusive for cutting chasing in wall/pillars/columns etc. of any description for concealing the conduits to required depth & making good the disturbed surface in cement mortar 1:4 including finishing by applying one coat of putty and two coat of Distemper to the surface to match with the existing surface.The portion of point wiring at ceiling shall be in surface conduit of suitable size fixed on ceiling surface with using PVC rawl plugs. (ii) Point wiring & earth wire shall be connected to each & every sunken box. (iii) All screws, fasteners, bolts, nuts & washer shall be cadmium plated & the cost of which is deemed to be included in the quoted unit rates. (iii) 1 x 5 Amps Independent board in one circuit of 1.5 sqmm and 1 x 16 Amps Socket board in one circuit of 2.5 sqmm / 4 sqmm be made. (iv) Wiring insulation test result sheet after or before carryng out the internal wiring must be recorded by contractor and the rate for the same deemed to be inclusive in the quoted rate. .
One light point controlled by one, one way 6 Amp switch
One fan/exhaust fan point controlled by one, one way 6 Amp switch
One 5 pin 5/6 Amps socket outlet point on the same board .
One 5 pin 5/6 Amps socket outlet point on independent board.
One bell point controlled by one, one way 6 Amp button switch.
All as per item No 2 here in before but point wiring with 2.5 Sq mm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 Sq mm PVC insulated multistranded copper conductor cable as continous earth wire.
All as per iten No 2 here-in -before but modular point wiring with in and including concealed/surface non metallic rigid PVC conduit not less than 25 mm dia including modular inner and outer frame plate matching with surrounding with modular sunken steel boxes zinc oxide plated of suitable size for mounting modular switches, sockets,regulator etc complete for the following
One light point controlled by one, one way 6 Amp modular switch.
One fan/exhaust fan point controlled by one, one way 6 Amp modular switch.
One 5 pin 5/6 Amps socket outlet point on the same board
One 5 pin 5/6 Amps socket outlet point on independent board
One bell point controlled by one, one way 6 Amp modular bell push.
Description all as per item 4 here in before but point wiring with 2.5 sq mm multistrand copper conductor cable for one six pin socket outlet 15 Amps controlled by one switch on independent board and 2.5 sq mm PVC insulated multistranded copper conductor cable as continous earth wire.
S & F switch piano, flush type, single pole one way, 5/10Amp complete all as directed. Make : Anchor Penta PC, Havells (Reo), SSK
S & F switch piano, flush type, single pole one way, 15/20 Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo),SSK
S & F socket outlet, multipurpose, 2 in 1 5 pin, 5/10 Amp complete all as directed. Make:Anchor Penta PC, Havells (Reo)/ SSK
S & F socket outlet, multipurpose, 2 in 1 5 pin, 15 /20Amp complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
S & F for Electronic step type fan regulator 100 watt 230 volts AC 50 Hz complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
S & F Call Bell AC 230 volts single pole complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
S & F Bell push flush type, 5 Amps complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK
S & F Modular switch single pole one way 6 Amp fixed complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S & F for Modular switch single pole one way 16 Amp complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S & F Modular socket outlet 2/3 pin combined 6 Amp 240 volts fixed complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S & F Modular socket outlet 2/3 pin combined 16 Amp 240 volts complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S & F Modular bell push flush type, 5 Amps complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S & F Fan regulator modular step type 120W 240 volts 2 module type complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S&F ceiling rose, 63.5 mm dia, ISI marked, three terminal of polycarbonate/isolated body complete all as directed. Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
S&F Batten holder including LED inverter bulb 9 watt retrofit type works on AC Normal mode and DC supply in inverter mode with inbuilt battery back up of up to 4 hours, high efficiency high lumens output ,including taking down old unsv led bulb PVC/polycarbonate type with back plate suitable for batten fittings complete all as directed. Make: Anchor Penta PC, Havells (Reo), SSK Make of bulb : Philips / Eveready /Havells
S & F sub main wiring with PVC insulated unsheathed FRLSH cable 1100 Volt grade, with multi stranded copper conductor drawing in and including rigid PVC conduit in concealed / surface as required at site including one run PVC insulated unsheathed cable with multi stranded copper conductor colour code as a earth continuity and connected upto DB including taking sown old unsv submain wiring of following sizes complete all as specified and directed. Make of wire:Havells/ Polyacab /Grandlay Make of conduit: AKG Plastic Pvt Ltd./Bhagwati Plastic & Agriculture industry /Polycab Note:Two/Four run of single core PVC cable with one run of earth conductor & condiut shall be measured as one unit. (ii) The quoted rates shall be deemed to be inclusive for fixing the conduits to surface with using PVC rawl plugs etc. (iii) Phase sequence colour code must be follow i.e Phase( Red) and Neutral ( Black) In colour and for three Phase RYB For phase and black for neutral.
2 x 10 Sqmm + 1 x 10 Sqmm
2 x 6 Sqmm + 1 x 6 Sqmm
2 x 4 Sqmm + 1 x 4 Sqmm
2 x 2.5 Sqmm + 1 x 2.5 Sqmm
4 x 6 Sqmm + 1 x 6 Sqmm
4 x 10 Sqmm+ 1 x 10 Sqmm
S & F in repairs MCB SP complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed of follwing capacity: Make:- Havells/ Indo Asian/ HPL
MCB SP6 to 32 Amp.240 volts
MCB SP 40 to 63 AMPS 240 volts
MCB SPN 6 to 32 Amps 240 volts
MCB SPN 40 to 63 Amps 240 volts
S & F in repairs MCB TPN complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 63A to 100A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable including connection with suitable size copper lugs complete all as directed of following capacity. Make:- Havells/ Indo Asian/ HPL
MCB TPN 63 Amps, 415 volts
MCB TPN 100 Amps, 415 volts
S & F in repairs sheet metal enclosure, single pole and neutral with two pin and earth plug and socket with and including one single pole MCB 20 Amps, , complying to IS/IEC 60898, 240 volts 'B' Curve 10 KA with energy limiting class 3. The MCB shall have 50% lower watt loss as required by IS/IEC 60898 from 6A to 63A . The mcb shall have the unique property of di-electric strength, arc resistance, insulation, flame retardancy and temperature resistance, including connection with suitable size copper lugs, The MCB shall give visible flag indication when MCB trips on Short Circuit Fault. The MCB shall have safety shutter to avoid any wrong insertion of cable. The MCB shall have the termination capacity of 35 Sq mm. The MCB shall have electrical life 20,000 operations up to 32A and 12,000 operation up to 63A including connection with suitable size copper lugs complete all as directed. Make:- Havells/ Indo Asian/ HPL
S & F in repair sheet metal enclosure, Triple pole and neutral with three pin and earth plug and socket with and including one triple pole MCB 100 Amps, 240 volts,10 KA , including taking down old unsv sheet metal enclosure complete all as directed. Make:- Havells/ Indo Asian/ HPL
S & F in repair MCB DB complying with IEC 61439 -1 & 3., sheet metal enclosures double door Including 01 x 40 to 63 A SPN MCB as incoming and MCB SP 6 to 32A as out gooning as per way of DB.The DBs should be supplied with tin platted insulated copper bus bar rated for 100A. 240 volts 2 in 1 shutter (Metal Door) with IK09 type with blanking plates where required and IP 43 degree protection, the DB door should be hinged type and possible to reversible at site.The DB door shall have overhang, to gel with wall properly.The DB shall be supplied with all insulated N. Bar riveted on Din channel frame and should not restrict cable entry from top or bottom.The DB shall have plastic knobs on shield to hold complete all as directed of following capacity. Make: Legrand/ Havells/ Indo Asian/ HPL
4 way SPN DB.
8 way SPN DB.
12way SPN DB
16 way SPN DB
S & F in repairs MCCB 4 pole ICS=100% ICU at 415 volts with rupturing capacity 18 KA with thermal-magnetic release and adjustable overload setting . The MCCB shall have a Mechanical life = 40000 operations & Electrical life = 8000 operations of following capacity Make:- Legrand/Havells/ Indo Asian
S & F in repairs Distribution boards epoxy powder coated TP & N (VTPN MCCB DB) fabricated from minimum 1.6 mm thick CRCA sheet and fixed/ flush to wall and suitable for universal mounting with 250 Amps fully insulated copper Bus Bar for each phase and 02 neutral shrouded bar ,2 earth bar and cable tie for cable management with reversible door for IP-43 DB,S protection,415 volt flush to wall including 01 Nos 160 Amps MCCB FP as incomer and 12/24 SP MCBs or 4 / 8 TP MCBs per per site requirement (or any combination of SP/TP MCBs) outgoings of following capacity . Make:- Legrand/Havells/ Indo Asian
4 Way VTPN DB (FP MCCB +12 MCBs).
8 WAY VTPN DB TP&N DB(FP MCCB +24 MCB,s)
M&L for Chemical Earthing Copper Bonded steel earth pipe of 3 metre long having diameter of 80 mm with copper bonding thickness 250 micron , CPRI tested at 25 KA fault current for one second and is provided with universal clamp made of SS Earth Enhancing compound of 50 KG /PIT (Resistivity should be less than 0.12 Ohm meter ) tested as per IEC 62561-7. M&L for Heavy Duty earth cover pit made of poly plastic having Load bearing capacity of 6000 kg. Size of Pit Cover : 270 mm x 240 mm x 200 mm The Electrode should be connected to GI WIRE 4 mm by means of nuts,bolts,check nuts & washers connected to main switch board,including all necessary excavation & earth work in hard dense soill with Backfill compound all around the electrode and necessary testing complete all as shown in drawings attached in tender all as specified and directed Note: (i) Earth lead wire and its protection pipe upto and including 7.5 mtr only from the top of earth electrode are included under this item. (ii) Any joints in earth lead from earth electrode to test point shall not be allowed/permitted.
S& F modular fitting /fixture in repairs including taking down old unsv fitting/fixture of following specification as described in item no. 31 to 36 Make: Anchor(Roma), Legrand (Mylinc), Havells (Crabtree)
Fan regulator modular step type 120W 240 volts 2 module.
Modular switch single pole one way 6/10 Amp 240 volts.
Modular switch single pole one way16/ 20 Amp 240 volts .
Modular socket outlet 2/3 pin combined 6/10 Amp 240 volts.
Modular socket outlet 2/3 pin combined 16/ 20 Amp 240 volts.
Modular bell push flush type, 6 Amps 240Volts.
Supply and fix in replacement of ceiling fan complete with blade ,down rod 230 Volts AC ,1200 MM Sweep Min air delivery 210 CFM Five star rated with brushless direct current ( BLDC) motor including modular fan regulator and connected with ceiling rose etc complete all as specified and directed. Make:- Crompton/Havells/Bajaj
Supply and fix in replacement of metal body exhaust fan 300 mm sweep 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Crompton/Havells/Bajaj
Supply and fix in replacement of metal body exhaust fan 450 mm sweep 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Crompton/Havells/Bajaj
Supply and fix in replacement of metal body exhaust fan 600 mm sweep 1400 rpm 230 volts 5h Hz, energy saving model single phase copper wound motor, grey in colour complete with blade, box type louvers etc complete all as specified and directed. Make:- Havels /Bajaj/Usha/ .
Supply and fix in repair Exhaust fan 250 mm sweep, 1200 RPM, ,made up of Sturdy Engineering Plastic complete ,voltage 230 Volts ,50 Hz, energy saving model single phase copper wound motor, white in colour complete with blade, box type louvers etc including taking down old unsv exhaust fan complete all as specified and directed. Make : Crompton/Havells/Bajaj
S&F Water heater (water heater) storage type 25 ltr capacity , five star rated AC SP 230 volts, 50 Hz, vertical mount type, shockproof and rust proof metal body, stainless steel inner container, high efficiency heating element, autocut thermostat, pressure release safety system, fire retardent cable with 3 pin plug metal top, white colour including fixing accessories like fastensers, nuts, washers complete of following capacity :- . Make: Havells(Adonia Series)/Jaquar/Bajaj
Supply and Fixing in repairs LED Batten light fittings 4 feet on walls including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Lumens: -system lumen not less than 2850 lm (ii) Housing: - High quality batten with extruded aluminium with Powder coated. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 130 lm/watt. (ix) Colour temperature (K): - Not less than 5700( COOL DAY LIGHT & WARM WHITE LIGHT ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 100-300V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 4 KV (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply and Fixing LED Batten light fittings 2 Feet on walls including including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Lumens: -System lumen not less than 1200 lm (ii) Housing: - High pressure die cast aluminium. (iii) IP Rating: - IP 20 (v) Mounting: - Wall Mounted (vi) Finish: - Polycarbonated diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 5700(COOL DAY LIGHT & WARM WHITE LIGHT ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 20 % with operating voltage 100-300V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 4 KV (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply and Fixing LED 1 x 1 feet Surface / Recess Mounted (depending upon requirement) light fittings including connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose all as conforming to the following parameters including taking down old unsv Light fitting: - (i) Lumens: - System lumen not less than 1800 lm. (ii) Housing: - CRCA sheet with powder coating (iii) IP Rating: - IP 20 (v) Mounting: - Surface /Recess Mounted (vi) Finish: - Opal PMMA Diffuser (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 6500( Cool day white /warm white ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 35000 Hrs of operation (xii) Optics: - Fully Diffused (xiii) Control gear: - inbuilt electronic driver, PF not less than 0.90 and THD less than 10 % with operating voltage 140-27V AC, 50 Hz (xiv) Surge protection: - inbuilt surge protection minimum 2.5 KV (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply and Fixing LED 2x2 Recessed/Surface Mounted fittings (depending upon requirement )including connecting the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv recess mounted fitting all as conforming to the following parameters: - (i) Lumens: - System lumen not less than 4000lm (ii) Housing: - Single Piece CRCA body (iii) IP Rating & IK Rating: - IP 20 & IK20 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - Ceiling/ Recess Mounted . (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED with Lens (viii) System Efficacy (lm/W) of the luminaries: - Not less than 120 lm/watt. (ix) Colour temperature (K): - Not less than 6500( Cool day white ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation @ Ta 35*C (xii) Optics: - Spread (Beam angle along the driveway) - 120°, Through (Beam angle across the driveway)- 60°, Beam pattarn- Asymmetrical driveway. (xiii) Control gear: - inbuilt electronic driver with 325V Auto Cut off Restart feature, PF not less than 0.95 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 3KV. (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply and Fixing LED Round/Square Surface/Recess Mounted Downlighter fittings (depending upon requirement )and connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv LED down lighter all as conforming to the following parameters: - (i) Lumens: - System lumen 1500 lumen & 2000 lumen (ii) Housing: - Single Piece body Die cast lluminium (iii) IP Rating & IK Rating: - IP 20 & IK20 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - On ceiling/Recess Mounted (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 6500( Cool day White /Warm Light ) (x) Color Rendering Index (CRI): - Not less than 80 (xi) Life: - Not less than 50000 Hrs of operation. (xii) Optics: -Diffused (xiii) Control gear: - PF not less than 0.90 and THD less than 20% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 2.5KV. (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
Supply and Fixing LED Flood Light fittings with complete fixing arrangemnets and connected the same with using PVC sheathed , insulated 3 core flexible 23/0.0076 copper cable including fixing arrangement for fixing the light fitting to ceiling rose including taking down old unsv led flood light all as conforming to the following parameters: - (i) Lumens: - System lumen not less than 5000 lm (ii) Housing: - Single Piece Aluminium die cast body (iii) IP Rating & IK Rating: - IP66 & IK07 (iv) Front cover: - Polycarbonated Cover for More protection (v) Mounting: - With complete fixing arangement, (vi) Finish: - Epoxy powder coated with any additional treatment for smooth and anti corrosive finish. (vii) Lamp: - High bright LED (viii) System Efficacy (lm/W) of the luminaries: - Not less than 100 lm/watt. (ix) Colour temperature (K): - Not less than 6500 (x) Color Rendering Index (CRI) & SDCM: - Not less than 70, <5 (xi) Life: - Not less than 50000 Hrs of operation at Ta 45*C (xii) Optics: -Diffused (xiii) Control gear: - PF not less than 0.90 and THD less than 10% at full load with operating voltage 140-270V AC, 50 Hz. (xiv) Surge protection: - inbuilt surge protection minimum 4KV. (xv) Heat Shink: - As per OEM's design Make: - Philips/ Havells/ Eveready/ Crompton
JS CONSTRUCTION COMPANY
M/S S P BUILDERS
Bhanu Prakash
PARADISE INFRA POWER COMPANY
KRISHANA ELECTRIC WORKS
M/s Anamika Enterprises
avtarsinghchaddha
Meher enterprises
venus engineers
M R Taders
PRAGATI ENTERPRISES
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .