Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹43.8 LAccepted-AOC | ₹43.8 L Quoted ₹44.7 L | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹45.2 L+₹54,588.63 (1.22%)Rejected-Finance | ₹45.2 L+₹54,588.63 (1.22%) | L2 | Rejected-Finance Become L2 |
| 3 | L3₹45.4 L+₹74,945.63 (1.68%)Rejected-Finance B S ROAD KOLIBARI TEZPUR 784 001 DIST SONITPUR ASSAM | SONITPUR | ASSAM | 784001 | ₹45.4 L+₹74,945.63 (1.68%) | L3 | Rejected-Finance Become L3 |
| 4 | L4₹45.6 L+₹89,384.28 (2.00%)Rejected-Finance NIL | ₹45.6 L+₹89,384.28 (2.00%) | L4 | Rejected-Finance Become L4 |
| 5 | L5₹46.1 L+₹1.5 L (3.28%)Rejected-Finance | ₹46.1 L+₹1.5 L (3.28%) | L5 | Rejected-Finance Become L5 |
Tender Value
Refer Docs
EMD Value
₹90,000
Closing Date
18 May 2022, 6:00 pmClosed
GE South Tezpur
GE South Tezpur Mission Chariali Tezpur, Assam
REPAIR/MAINT OF INTERNAL ELECTRIFICATION, COLD STORAGE, PACKAGE PLANT AND OTHER ALLIED WORKS AT ZONE 5 (155 BH, 4 CDU, 56 FMSD, 118 FHO), ZONE-2A, 2B AND 4 UNDER GE (S) TEZPUR
2022_MES_520819_1
8653
Open Tender
Civil Works
Item Rate
180 days
GE South Tezpur
As per NIT
4 documents required · 4 mandatory
₹500
Yes
GE South Tezpur
₹90,000
Yes
14 Jul 2022
29 Apr 2022
20 May 2022
29 Apr 2022
18 May 2022
12 May 2022
Amount
M&L for rewinding of ceiling fan,1200mm any make and any type of model, after taking burnt out old winding wire complete and cleaning the internal slots of rotor with ring and rewinding the ceiling fan with super enamelled copper winding wire of suitable SWG Varnishing, baking in oven and reassembling with new bearings (both) and new capacitor complete all as specified and directed
All as per Item No 1 as above but for ceiling fan of 1400mm size
All as per Item No 1 as above but for Exhaust fan of 200/225/250 mm size
All as per Item No 1 as above but for Exhaust fan of 300/380 mm size
M&L for painting of fan (ceiling fan / exhaust fan/wall mounted fan ) any sweep with applying one coat of synthetic enamel paint (Ceiling Fan -White Paint and Exhaust fan - Gray Paint ) by spray machine including preparation of old painted surfaces with filling of cavity by filler with and including writing of MES No. of fan in capital letters with black synthetic enamel paint of height not less than 20mm on fan body in approved pattern complete all as specified and directed.
Supply and Fix louver shutter (with Mosquito net made out Aluminum wire cloth 0.36 mm nominal dia ) made out GI sheet for Exhaust fan 300/400 mm sweep including proper fixing with screw in wall at existing Hole including taking down old unsv louver shutter complete all as specified and directed.
S & F Capacitor( 2.5-4) MFD for ceiling fan/Exhaust Fan of any make, any model and any sweep including taking down old unsv capacitor. Make- Havells/Usha/Tibcon/Universal
S & F Down rod 15mm bore medium grade GI pipe including cut in required length and drilled as per existing size including taking down old unserviceable down rod complete all as specified and directed.
S & F Fan blade for Ceiling fan of 1200mm sweep of white colour including taking down old unsv fan blade complete all as specified and directed.
S & F in repair Factory made sheet metal enclosure for DBs double door (Fixed flush to the wall), SPN, 240 volt, 8 Way, IP-42 protection with 200 Amp rated bus bar and 1.5 Sq. mm copper PVC sheathed cable for earth continuity and suitable for having MCB’s complete and all disturbed surfaces of wall shall be made good to match the existing wall finishes all as specified and directed by Engineer-in-charge. make- L&T/Havells/legrand
All as per Item No 10 but for DB 6 way.
S & F Power line vertical type TPN DB double door 4 way, IP 43 suitable for MCCB 100 amps CRCA sheet metal enclosure with detachable gland plates for flush / surface mounting with bus bar neutral link and Earth Bar in concealed and all disturbed surfaces of wall shall be made good to match the existing wall finishes complete all as specified and directed. make- L&T/Havells/legrand
S & F in repair MCB SP 6 to 32 Amp, B series , 230 Volts complete all as specified and directed . Make - L&T/Havells/C&S/legrand/hager.
S & F in repair MCB DP 6 to 32 Amps, B series, 230 Volts complete all as specified and directed . Make - Scheinder/Havells/C&S
S & F in repair MCB DP 40-63 Amps, B series, 230 Volts complete all as specified and directed. Make - Scheinder/Havells/C&S
S & F in repair MCB TPN 40-63 Amps, B series, 10 KA "B" series 415 Volt complete all as specified and directed. Make : L&T/Scheinder/Havells
S & F in repair MCCB 4 Pole 415V Fixed type 25-100A with breaking capicity 16 KA complete all as specified and directed. Make : L&T/Scheinder/Havells
S & F in repair RCBO 2 Pole 32A, 230V , sensitivity 100mA, having protection for earth leakage, overload and short circuit complete all as specified and directed. Make : L&T/Scheinder/Havells
Taking down the existing U S wiring carefully of aluminium/copper point wiring (light, fan, bell, socket, power point etc.) with conduit/casing caping, along with all connected accessories etc complete all as directed.
M&L for point wiring complete for One light point with 1.5 Sqmm single core multistranded copper conductor FR PVC insulated and unsheathed cable 1100 volts grade ISI marked drawn through PVC casing caping including provn of 1.5 sqmm single core multistranded copper conductor FR PVC insulated and unsheathed as earth wire continuity including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition) complete all as specified and directed. wire Make- polycab/havells
All as per Item No 20 above but for one fan / Exhaust fan point
All as per Item No 20 above but for One 3 pin 5 Amp socket outlet on the same board
All as per Item No 20 above but for One 3 pin 5 Amps socket out let on independent board
All as per Item No 20 but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
All as per Item No 20 above but for one bell point controlled by one 5 amp switch
All as per Item No 20 above but for one light point controlled by two two way switches
S & F in repair electronic fan regulator,100W ,230V ,50Hz stepped socket type for ceiling fan complete all as specified . Make- Anchor/Leader/Standard
S&F in repair switch piano type, 5 Amp. SP, one way all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG/Indoasian
S&F in repair switch piano type, 15 Amp. SP, one way all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG/Indoasian
S&F in repair socket outlet, 2 in one 5 pin, 5 Amp, piano type all as directed/ specified. Make- legrand/Anchor/ Havells/Indoasian
S&F in repair socket outlet, 2 in 1, 3 pin 5 and 15 Amp flush type universal all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG/Indoasian
S&F in repair switch bell push, flush type, 5 Amp all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG/Indoasian
S&F in repair bell, AC, 230 V, SP, ding dong type all as directed & specified. Make Anchor/leader/ Bajaj
S&F in repair of Ceiling rose 3 phase, PVC/ Polycarbonate body all as directed/ specified.
S&F in repair switch two way switch flush type, 5 Amp all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG/Indoasian
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 100 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 175 mm x 100 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 200 mm x 105 mm and 50 mm deep complete all as specified and directed.
M&L in repair for PVC rectangular block for mounting, switches, sockets, fan regulator etc. with 3 mm thick plastic laminated sheet cover of size 250 mm x 200 mm and 50 mm deep complete all as specified and directed.
M&L in repair laminated sheet or hylam sheet for mounting, switches, sockets, fan regulator etc. of any size as per site requirement complete all as specified and directed.
S & in repair PVC casing caping of any size complete all as specified and directed.
M & L for Point wiring for one light point with 1.5 sqmm PVC insulated and unsheathed copper conductor multistranded 1100 volts grade, ISI marking drawn thorugh and existing/new non metallic concealed PVC rigid conduit and conduit accessories, medium grade, ISI marking, concealed Frame for fixing switches, sockets, inculding one run of 1.5 sqmm PVC insulated unsheathed copper cable FRLS grade as in earth wire for continuity and connecting to earth dolly for one light point controlled by one switch complete including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the wall (wash/paint/distemper) wherever required(as per the existing condition) all as specified and directed Note - The cost of modular metal flush box and Modular white Cover Plate with Frame, MS terminal boxes, laminated hylem sheet if required shall be deemed to be included in the unit rate. make- polycab/havells
All as per Item No 42 above but for one fan / Exhaust fan point
All as per Item No 42 above but for One 3 pin 5 Amp socket outlet on the same board
All as per Item No 42 above but for One 3 pin 5 Amps socket out let on independent board
All as per Item No 42 above but with 2 x 2.5 Sqmm +1 x 1.5sqmm Copper conductor cable for one 3 pin, 15 Amps Switch socket out let on independent board.
All as per Item No 42 above but for one bell point controlled by one, one 5 amp switch
S&F in repair modular switch flush type, 6 Amp. SP, one way ,1 module all as directed specified. Make- Anchor/ Havells/Bajaj/ CG/Indoasian
S&F in repair modular socket outlet, 3 pin, 6 Amp, flush type 2 module all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG//Indoasian
S&F in repair modular switch, 16 Amp flush type 1 module all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG//Indoasian
S&F in repair modular socket outlet, 3 pin, 6/16 Amp flush type 2 module all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG//Indoasian
S&F in repair modular bell push, flush type, 5 Amp,1 module all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG//Indoasian
S&F in repair modular Fan Regulator step type 2 module ,120W all as directed/ specified. Make- Anchor/ Havells/Bajaj/ CG//Indoasian
Taking down old unsv submain wiring of any size complete all as specified and directed
M&L for sub main wiring with two run of 4.0 Sq. mm PVC un-sheathed, copper conductor cable, 1100 Volt, and one run of copper earth wire 4.0 Sq mm drawn through PVC concealed conduit and all accessories,including making good the disturbed surface by Putty and matching the colour of wall with the existing colour of the (wash/paint/distemper) wherever required(as per the existing condition), complete all as specified. Note: Copper conductor 2 run and one run of copper earth wire shall be measured as one length.
All as per Item No 55 above but for 2 x 6.0 sqmm + 1 x 6.0 sqmm earth wire
S& F ceiling fan of sweep not less than 1200mm, 5 star, BLDC type motor, without remote with hanger including taking down existing old unseviceable ceiling fan and taking to MES Store as specified and directed. Make- Havells,Cat No-Efficiencia Neo (BLDC 26 W) or equivalent make of Bajaj/Usha/CG
S& F exhaust fan of sweep 225 mm metallic body including taking down existing old unserviceable ceiling fan and taking to MES Store as specified and directed. Make- Crompton, Cat No-DRIFT AIR PLUS METAL ANTI DUST or equivalent make of Havells/Bajaj/Usha
S& F exhaust fan of sweep 300 mm metallic body including taking down existing old unseviceable ceiling fan and taking to MES Store as specified and directed. Make- Crompton, Cat No-300mm TRANSAIR (Double Ball Bearing) or equivalent make of Havells/Bajaj/Usha
S& F exhaust fan of sweep 225 mm, PVC body including taking down existing old unserviceable ceiling fan and taking to MES Store as specified and directed. Make- Crompton, Cat No-BRISK AIR NEO or equivalent make of Havells/Bajaj/Usha
S& F in repair Geyser of 25 Ltr Vertical / horizontal mounted , 5 Star rated and taking old geyser to MES Store as specified and directed. Make- Havells, Cat No-GHWAMGSIB025 or equivalent make of Bajaj/Usha/CG
S& F in repair Geyser of 50 Ltr Vertical / horizontal mounted , 5 Star rated and taking old geyser to MES Store as specified and directed. Make- Havells, Cat No-GHWAMGSWH050 or equivalent make of Bajaj/Usha/CG
S & F 9 Watt LED fitting, B22 base, 3 star, colour temp 6000k, including taking down old unserviceable type bulb all as specified and directed by Engr in charge . Make-Havells,Cat No-LHEXBLP7IN1W009 or equivalent make of Phillips/Bajaj/Surya/HPL
S & F angle bulb holder for LED fitting, B22 base, including taking down old unserviceable type holder all as specified and directed by Engr in charge.
Supply and Fixing in repairs wall mounted LED batten, polycarbonate housing & integrated electronic driver. LED light fittings flicker free, instant start with uniform light distribution 10 W 6500k 2 ft indoor decorative with 2 Core copper wire from ceiling rose to light fitting. Make-Havells, Cat No-LHEXACP7IN1W010 or equivalent make of Phillips/Bajaj/Surya/HPL
All as Per Item No- 66 , but for 20W 4 ft.Make-Havells,Cat No-LHEXACP7IN1W020 or equivalent make of phillips/bajaj/Surya/HPL
S & F 12 Watt LED panel fitting surface mounted (1 ft x 1 ft ) including surface accessories , colour temp >= 5700K with die cast body with premier diffuser ensuring glare free light including taking down old unserviceable type downlighter all as specified and directed by . Make-Havells/phillips/bajaj
S & F 12 Watt LED panel fitting surface mounted ( 2 ft x 2 ft ) including surface accessories , colour temp >= 5700K with die cast body with premier diffuser ensuring glare free light including taking down old unserviceable type downlighter all as specified and directed by . make-Havells/phillips/bajaj
S & F 10 Watt LED panel fitting surface mounted including surface accessories , colour temp >= 5700K with die cast body with premier diffuser ensuring glare free light including taking down old unserviceable type downlighter all as specified and directed by . make-Havells/phillips/bajaj
M & L Earthing complete with GI earth plate electrode 60cmX60cmX6 mm thick buried directly in ground (earth pit not less than 2.25 mtrs deep below ground level) with top edge of the plate not less than 1.5 mtr below normal ground level, connecting to galvanized earth strip 32 x 6 mm as earthing conductor by means of bolts, nuts, check nuts and washers of GI and all as shown in Electrical plate No.3 of SSR Part I and including testing on completion all as specified locations and as directed by the Engineer-in-Charge. Note: 1.The above quoted rate shall include cost of main earthing lead of 32 x 6mm GI earth strip, charcoal, salt, excavation and earth work in any type of soil CI cover, funnel with 20mm dia light grade GI water pipe including GI protection pipe 40mm dia light grade for earth strip etc. 2. The cost of earth pit is deemed to be included in the unit rate. 3. The cost of taking down old unsv earthing with all its accessories is deemed to be included in the unit price.
Supply and laying or fixing or passing through pipe in replacement of , 1100 volts grade heavy duty cable with PVC insulated Stranded aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core 6 sq. mm nominal cross section in service connections complete all as directed. Make - Finolex /Havells/Polycab or equivalent
All as per Item No 72, but for 2core 10 sqmm
S & F in repair connection pipe (both hot & cold) of any size as per site requirement for geyser of any capacity complete all as specified and directed. Note- Both hot and cold pipes are deemed to be one unit.
Supply and fix Heating element of 1500/2000 watts suitable for 25 ltrs capacity water heater including taking down old unsv element complete all as specified and directed.
S & F Thermostat of range 0-80 degree Celsius suitable for 25 Ltrs water heater including taking down old unsv thermostat complete all as specified and directed.
Supply and fixing in repair compressor sealed type suitable for 3 phase split type AC 5 ton capacity including making necessary connection complete all as directed..
Supply and fixing sub zero compressor controller for two compressor including connection and wiring at specified location and testing complete all as specified and directed.
Supply and fixing in repair temperature gauge for both cold room and cool room in showing centigrade and Fahrenheit complete all as specified and directed.
Supply and fixing in repair blower fan motor (outdoor unit) for 5 ton compressor complete all as directed.
Supply and fixing in repair blower fan blade (indoor unit) for 5 ton compressor complete all as directed.
Supply and fixing in repair three pole contactor suitable for 3 phase split type AC 5 Ton capacity including making necessary connection complete all as directed.
Supply and fixing in repair drier of 5/8 inch type for cold storage plant complete all as directed.
Supply and fixing in repair HP switch for 5 ton compressor for cold storage plant complete all as directed.
Supply and fixing in repair LP switch for 5 ton compressor for cold storage plant complete all as directed.
Supply and fixing in repair nitride insulation 7/8' (11x5 mtr) for insulating refrigerant flow copper tube complete all as directed.
Supply and charging of refrigerant gas R-134A for cold storage plant complete all as directed.
M&L for carrying out pressure test Quarterly of the entire system connection to open type /sealed compressor unit and checking for leakage with filling nitrogen gas to required pressure rectify leakage and again testing to the entire satisfaction of GE complete all as directed.
Supply and fix in repair of rubber mounting pad for package AC outdoor unit as directed.
Supply and fixing in repair 440 Volts MCCB , Four pole ,"C" curve , 125 Amps 25 KA breaking capacity complete all as specified and directed.
Supply and fix MCCB 4 pole, microprocessor based Release range 100 Amps to 250 Amps,415V,AC,50Hz ,36 KA Manual versions With Conforms to IS/IEC 60947-2,Ics=100% Icu,Suitable for Isolation Adjustable Over Load setting: 0.4 - 1.0 x In ,Adjustable Short Circuit setting: 1.5 - 10 x Ir , ,Wide Range of snap fit Internal and External Accessories including Taking down old MCCB all as specified and directed by Engineer-in-charged Make - Siemens/L&T/Schneider/ABB/Havells/Legrand
Excavation in trenches n.exc 1.5 mtr wide and n exc 1.5 mtr in depth and getting out in soft/ loose for laying cables, etc. complete all as specified and as directed.
Returning, filling including spreading, leveling, watering and well ramming in layers n.exc 25 cm in soft/loose soil complete all as specified and as directed.
Removing surplus excavated soil n.exc 50 mtr and depositing where directed at a level n.exc 1.5 mtr above the starting point complete all as specified and as directed..
Supply and laying natural river sand as cushioning of cables, including spreading and punning down all as per clause No 3.21 of SSR part -I complete all as specified and directed by Engineer-in-charge and directed by Engineer in charge Note : punned thickness will only be measured for payment purpose.
M&L for sub class 'B' brick for protection of UG cable in tranches of old size brick all as specified and directed by Engineer-in-charge.
Supply /laid/ fixing/ connecting and testing in replacement of the following LT under ground XLPE insulated ,armored heavy duty electric power cable with aluminum conductor , 1100 volts grade (earthed) cross section area 95 Sqmm x 3.5 core. Make - Havells/Gloster/Polycab/KEI
Supply and fix in repair of four core cable copper conductor PVC insulated multistranded sheathed 1100 Volt grade 2.5 sqmm complete all as specified & directed.
Supply and fixing in repair MCBs , 440 Volts grade, triple pole ,"C" curve , 32 Amps 25 KA breaking capacity complete all as specified and directed. Note 1:-The contract sum shall be arrived at after deducting amount of schedule of credit from the total quoted amount. Note 2-Contractor's supervisor and main worker would wear shirt/T-shirt of colour sky blue/brown/yellow preferable embossed with contractor's firm name while carrying out any activities in defense area for better check of security purpose. Note 3:-The tendered (all eligible contractors) shall ascertain the taxes & levies as on date. The subject tender caters all the taxes & levies as on date including the latest notification of GST issued as on date ( issued by Central Board of Indirect Taxes and Customs)
M/S Deep-Jeet
Anil Kumar Sarmah
M/s. M. G. Babloo Das
M/s Brahamaputra Wood Industries
D G Corporation
DRISTEE ASSOCIATES
M/S N S CONSTRUCTION
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .