Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹39.6 LAccepted-AOC | L1 | Accepted-AOC HENCE L1 | |
| 2 | L2₹41.5 L+₹1.8 L (4.52%)Rejected-Finance | L2 | Rejected-Finance HENCE L2 | |
| 3 | L3₹44.0 L+₹4.3 L (10.9%)Rejected-Finance | L3 | Rejected-Finance HENCE L3 | |
| 4 | L4₹47.9 L+₹8.2 L (20.7%)Rejected-Finance 4TH FLOOR DOOR NO 10 28 2 4 402 BUISINESS BAY BUILDING WALTAIR UPLANDS SIRIPURAM VISAKHAPATNAM 530003 | VISAKHAPATNAM | VISAKHAPATNAM | ANDHRA PRADESH | 530003 | L4 | Rejected-Finance HENCE L4 | |
| 5 | L5₹50 L+₹10.3 L (26.1%)Rejected-Finance | L5 | Rejected-Finance HENCE L5 |
Tender Value
₹48 L
EMD Value
₹96,000
Closing Date
19 Aug 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE Wks 4
DGNP Naval base post Visakhapatnam
REPAIRS and CLEANING OF SEPTIC TANKS SEWAGE LINES PETTY REPAIRS LIMBER HOLES IN SECURITY WALLS CLEANING OF DRAIN AND REPAIR TO JOINERY
2020_MES_363821_1
GE WKS 4 TOKEN 01 OF 2020 21
Open Tender
Civil Works
Item Rate
90 days
Rambilli
As per NIT
7 documents required · 7 mandatory
₹500
DGNP
₹96,000
Yes
7 Oct 2020
24 Jul 2020
21 Aug 2020
24 Jul 2020
19 Aug 2020
14 Aug 2020
24 Jul 2020 - 3 Aug 2020
90 days
Amount
Cleaning of manholes of depth n.exc 1.5mtrs including bailing /pumping out sludge , waste water etc complete and disposing them by depositing the same in near by pits to a distance n.exc 100 mtrs from the manholes , but away from wells / water storage tanks,complete all as specified and directed by engineer-in-charge.
All as per Sl item No.1 above but for depth exc 1.5 mtrs but n.exc 3.00 mtr.
Cleaning of sewage lines, dia 150 mm dia, manually or by mechanical means, removing all solid/waste materials etc. including opening manhole cover and testing the sewage line using clear water after cleaning complete all as specified and directed by engineer-in-charge.
Cleaning of septic tank 100 users capacity by pumping out /bailing out sludge complete all as directed at site and making it free from any residual waste ( solid/liquid whatsoever) and disposing off sludge and waste water etc by depositing the same in near by pits to a distance n.exc 100 mtrs from the manholes, but away from wells/water storage tanks, complete all as specified and directed by engineer-in-charge.
Cleaning of following Traps and clearing the chocked/blocked traps complete all as directed at site and removing the rubbish away from site complete :-
(a) Floor/Nahani Traps
(b) Gully Traps
(c) Traps of IWC/EWC
Demolition of cement concrete of any description and in any position not otherwise specifically provided for and removal to a distance n.exc 100 mtrs complete all as specified and directed by engineer-in-charge.
M &L for salt-glazed stoneware 150mm bore drain pipes grade A laid in trenches and jointed complete all as specified and directed by engineer-in-charge.
M&L for Concrete bed to 150mm bore drain pipes incl packing under, and haunching against the sides of pipes after they are laid and tested; in cement concrete 1:4:8 type D2 (using 40mm graded stone aggregate) complete all as specified and directed by engineer-in-charge. Note for item No 7 & 8:- Excavation and earth work shall be measured and paid separately.
M&L cutting into existing manholes for connecting new drains dia 150mm, making good to pipe and rendering cutting out existing benching for and forming branch channel (1/2 round or 3/4 section) in cement concrete 1:2:4 type B-1 smooth finished and reforming benching as required complete all as specified and directed by engineer-in-charge.
M&L for PCC 1:4:8 type D2 (using 40 mm graded stone aggregate) in foundation, filling and mass concrete complete all as specified and directed by engineer-in-charge.
Taking down existing wall tiles and M&L for glazed ceramic tiles in vertical surface match to existing size and colour in bathrooms set and jointed in neat cement slurry and pointed in colour cement to match complete all as specified and directed by Engineer-in-charge. (The rate includes for all straight cutting & waste)
M&L for RCC 1:2:4 type B1(Using 20 mm graded stone aggregate) in walls, retaining walls any thickness complete all as specified and directed by Engineer-in-Charge.
M&L for steel formwork to sides, faces of vertical walls, retaining walls and similar works etc vertical or to batter and like for fair finished surfaces of concrete complete all as specified and directed by Engineer-in-Charge.
M&L for reinforcemnt in any situation using CRS TMT steel bars of grade Fe-500D, 10mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for coloumns and biding with andincluding mild steel wire (annealed) not less than 0.9mm dia for securing with clips complete all as specified and directed by the engineer-in-charge.
M&L for 150mm dia limber holes depth n.exc 300mm in existing RCC security wall and fixed GI pipe with CI gratings complete all as specified and directed by engineer-in-charge.
Chip off removal the existing plastering, PCC and loose concrete with hammer and chisels and using chippint machines where necesary. Make the concrete surface neat & clean.
Pouring Microconcrete using RENDEROC RG for 100mm thick with 12mm below grade chips and required water including labour charges complete all as manufacturer instructions.
Applying the bonding agent NITOBOND EP to make the bond with new concrete complete all as manufacturer instructions.
M&L for PCC 1:1.5:3 type A1 ( Using 20mm graded stone aggregate) with water proofing compound match with existing surface complete all as specified and directed.(WPC paide separately)
Taking out old filler from expansion joints complete all as specified and directed by Engineer-in-Charge.
M&L for forming 12 mm thick expansion joints filled with preformed bituminous filler and top 30 mm promed and sealed with sealing compound Grade 'B' complete all as specified and directed by engineer-in-charge.
M&L for applying tack coat of industrial bitumen 85/25 at the rate of 1.2 Kg per sqm including cleaning surface complete all as specified and directed by engineer-in-charge.
Supply and fix in repairs, 110mm bore PVC (SWR) pipes, single socketed, in any length with rubber ring joints laid in trenches or in floors complete all as specified and directed by engineer-in-charge. Note:- The rates include for all necessary extra joints, cutting and waste. eathework/excavation shall be measured and paid separately.
Supply and fix 110 mm bore PVC (SWR) bends of any radius complete all as specified and directed.
S&F chromium plated brass single lever concealed divertor for bath room, shower system with provision of two cold inlets and one hot inlet all as specified and directed by engineer-in-charge. Make: Jaquar/Parry ware
Taking down Aluminium door shutter repairing, tightening of sutter hinges or changing the position of hinges adjustment of tower bolts sliding bolt etc, replacement of fittings and refixing in the same opening not exc. 4.5 sqm each complete all as specified and directed by engineer-in-charge.
M&L for fixing of mortice lock, brass vertical type size 100 mm 4 livers with escutcheon plates and two keys complete all as specified and directed by engineer-in-charge.
S&F ISI marked hydraulically regulated door closer die cast body type complete suitable for door shutter width upto 2.00 mtr and weight between 5 to 10 kgcomplete all as specified and directed by engineer-in-charge.
Rough excavation not exceeding 1.5m deep and getting out in soft and loose soil complete all as specified and directed by engineer-in-charge.
Rough excavation exceeding 1.5 m but not exceeding 3.00 mtr deep and getting out in soft and loose soil complete all as speicified and directed by engineer-in-charge.
Excavation in trenches n.exc. 1.5m wide and n.exc 1.5m in depth and getting out in soft and loose soil and removing and refixing of existing cover slabs in CM 1:4 where laying and complete all as specified and directed by engineer-in-charge.
Excavation in trenches n.exc. 1.5m wide and n.exc 3.00 m in depth and getting out in soft and loose soil complete all as specified and directed by engineer-in-charge.
Removing excavated material n.exc. 50 m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by engineer-n-charge
Removing excavated material exc. 250 m but n.exc 500m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed by engineer-n-charge
Returning filling including spreading, levelling, watering and well ramming in layers not exc 25 cm complete all as specified and directed by engineer-in-charge.
Taking down cement plaster any description from brick work, racking out joints, hacking for key scrubbing down with water etc complete and removing outside MD land.
Demoiltion of brick masanory of any descriptuion built in CM complete all as specified and directed by engineer-in-charge.
M&L for brick work with sub class 'B' bricks straight or curved on plan exc 6m mean radius built in CM 1:6 complete all as specified and directed by engineer-in-charge.
M&L for rendering 15mm thick in CM 1:4 on other than fair faces of bricks surfaces without using extra cement with using liquid water proofing compound complete all as specified and directed by engineer-in-charge. (WPC shall be measured and paid separately under item No 43)
M&L for rendering 10mm thick in CM 1:4 on fair faces of bricks or concrete finished even & smooth without using extra cement complete all as specified and directed by engineer-in-charge.
M&L for oil bound distemper two coats over a coat of primer including 3mm thick wall care putty & preparation of newly plastered surfaceof wall complete all as specified and directed by Engineer-in-charge.
M&L for preparation of newly plastered surface ow wall and applying two coat of exterior emulsion weather proof paint with anti fungal properties over a coat of primer over 3 mm thick exterior graded putty all as per manufacturer instructions complete all as specified and directed by Engineer-in-charge.
Supply only liquid water proofing compound.
Draining out water from existing water storage tank exc 500 ltr and not exc 2000 ltr capacity and cleaning silt deposited therein, washing out with bleaching powder including taking down connection and refixing complete all as specified and directed by engineer-in-charge.
JAI ENTERPRISES
sagar infra
anjaliinfratech
Jessica Engineering Works
K KUMAR RAJA PROJECTS P LIMITED
jd constructions
B.Veerabhadra Rao
MAHALAKSHMI INFRA PROJECTS
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .