Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | 1₹5.6 LAccepted-AOC HALFLONG DHARMANAGAR NORTH TRIPURA 799254 | NORTH TRIPURA | TRIPURA | 799254 | ₹5.6 L | 1 | Accepted-AOC AOC |
| 2 | 2₹6.2 LRejected-Finance JAWHARNAGAR DHALAI TRIPURA | ₹6.2 L | 2 | Rejected-Finance None |
| 3 | 3₹6.4 LRejected-Finance BIRGANJ AMARPUR GOMATI TRIPURA | AMARPUR | GOMATI | TRIPURA | 799101 | ₹6.4 L | 3 | Rejected-Finance None |
Tender Value
₹9.7 L
EMD Value
₹19,341
Closing Date
16 Mar 2026, 3:00 pmClosed
The Executive Engineer.
O/o the Executive Engineer, DWS Division, Ambassa.
Running and maintenance of existing Iron Removal Plant attached to DTW Schemes within the jurisdiction of Raishyabari R.D Block under DWS Sub-Division, Gandacherra. (Gr-II).
2026_CEDWS_71393_1
157/EE/PWD(DWS)/AMB/2025-26
Open Tender
Civil Works - Water Works
365 days
District
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹19,341
5 Jun 2026
10 Mar 2026
16 Mar 2026
10 Mar 2026
16 Mar 2026
10 Mar 2026
abour charge for opening the oxidation chamber & removing the old media etc complete as per direction of Engineer in charge.
Providing and placing rapid gravity filter sand having effective size of 0.50 mm to 1.00 mm & uniformity co-efficient of not more than 1.70 and or less than 1.30 obtained from Barakar river West Bengal as per specification and the direction of the Engineer - in - charge.
Providing and placing filter gravel having effective size of 3.00 mm to 25 mm & uniformity co-efficient of not more than 1.70 and or less than 1.30 obtained from Barakar river, West Bengal as per specification and the direction of the Engineer - in-charge.
Providing and placing of anthracite coal ( 3 mm to 6 mm) of SP gr. 1.4 in IRP as per specification & direction of the Engineer-in-charge.
Lifting of filter media from package type IRP filter chamber as per specification and the direction of the Engineer-in-charge.
Providing and fitting fixing of poly propylene double hexagonal nut strainers (threaded type) inside the IRP vessel of approved quality as per direction of the Engineer-In-Charge.
Providing and placing of MnO2 (size 20 mm to 40 mm) inside the Oxidation chamber after removing existing old Mn O2 from the chamber as per specification and direction of the Engineer in charge.
Providing & fixing MS bolts in/c nuts & washers complete as per standard up to 300 mm length
labour charges for repairing Air blower,air compressor,strater main switch and electric wireing etc.complete as per specification and the direction of the engineer-in-charge.
Providing and fixing CIDF Butterfly valve with bolts, nuts, rubber insertions etc. complete as per CPWD specification and direction of the Engineer - in - charge. ( The tail pieces, tappers etc if required will be paid separately )
100 mm dia
125 mm dia
150 mm dia
Providing and fixing CI Diaphragm valve of approved quality as per specification and direction of the Engineer - in - charge.
i. 150 mm dia
Painting with black anticorrosive bitumastic paint (one or more coat ) of approved brand & manufacture on old work to give an even shade in/c preperation of surface as required complete as per direction of the Engineer in charge.
Painting with synthatic enamel paint( one or more coat) of approved brand & manufacture on old work to give an even shad in/c preperation of surface as required complete as per direction of the Engineer in charge.
welding by gas or electric plant in/c transportion of plant site etc complere as per standard design.
Supplying of sodium Hypochloride solution to the IRP as per direction of the Engineer incharge.
Supplying & fitting fixing of Alum Dosing metering pump Model No. DTH #2125MD, rated capacity 100LPH with CGL make motor 0.37 kw/.50HP, 4 pole, frame size:71 complete as per specification & direction of the Engineer in charge.
Providing and fitting fixing steel sheet enclosed switch fuse (suitable for DIN fuses), triple pole with Neutral Link (TPN), 415/500 Volt, L & T / Havells / BCH make etc. complete as per direction of the Engineer-in-charge.
ii.63 amps
iii. 100 amps
iv. 200 amps
Providing and fitting fixing of Direct on line (DOL) motor starter L&T/BCH make ( 3 phase, 50 Hz, 10 HP/7.5 kw relay range within 13-21 + 10%) in steel sheet enclosure complete as per direction of the engineer in charge.
Supplying and fitting fixing Kay Rotary Twin Lobe compressor model no. 55 AC having capacity 300 cum/hr and pressure 0.35 kg/sq.cm complete i/c 7.5 Hp motor 1440 rpm of approved quality as per direction of the engineer in charge.
Rewinding of Horizontal Motor suitable for centrifugal pumps by complete dismantling in/c providing & rewinding with Super enamelled copper conductor (as per IS:13730 Part-3) conductor & all necessary spare parts and reassembling the same including servicing of rotor & necessary trial run as per specification and direction of the Engineer in charge. i. 3.0-5.0 HP
Taking out lime stone / graded gravel / filter sand from top slab of sedimentation tank filter bed, through washing by water & placing the whole lime stone / graded gravel / filter sand at original place after washing in IRP as per specification and the direction of the Engineer-in-charge.
Charges for making G.I. Short piece i/c. cutting, threading at both end, fitting, fixing at site etc. as per specification and the direction of the Engineer-in-charge. ( G.I. pipes will be supplied from the department free of cost ).
i. 150 mm dia.
ii. 125 mm dia.
iii. 100 mm dia.
vii. 40 mm dia.
Charges for making G.I. reducer i/c. cutting, welding, threading at both end, fitting, fixing at site etc. as per specification and the direction of the Engineer-in-charge. ( G.I. pipes will be supplied from the department free of cost ).
i. 150 x 125 mm dia.
ii. 150 x 100 mm dia.
iii. 125 x 100 mm dia.
v. 100 x 50 mm dia.
Providing & fitting fixing of G.I. flange ( 10 mm wall thickness ) by welding with G.I. / MS pipe and placing position as per specification and the direction of the Engineer-in-charge.
i. 150 mm dia
ii. 125 mm dia
iii. 100 mm dia
vi. 50 mm dia
Providing and fitting fixing PVC suction hose pipes of wall thickness 6 mm. as per relevant IS specification and direction of Engineer-in-charge.
i. 80 mm dia
ii. 100 mm dia
iii. 125 mm dia
iv. 150 mm dia
v. 200 mm dia
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_72643.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 2.37 MB
DNIeT157.pdf
Tender Documents • 2.85 MB
BOQ_72643.xls
BOQ • 0.33 MB
Download all tender documents and submit your bid