GEMC-511687769891371
Awarded to TRACK MANUFACTURING CO. PRIVATE LIMITED
₹14,000
Products
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| HCV CARDS | 10RT10410 | - | 500 NOS | ₹28 | 14,000 |
Loading…
| # | Company | Offered Item | Amount | Rank | Status |
|---|---|---|---|---|---|
| 1 | L1₹14,000Qualified Make: VOXPRESS
Model: 10RT10410 3 ASIA HOUSE K G MARG NEW DELHI DELHI 110001 | NEW DELHI | DELHI | 110001 | Make: VOXPRESS
Model: 10RT10410 | L1 | Qualified | |
| 2 | L2₹19,500+₹5,500 (39.3%)Qualified Make: RAPID DIAGNOSTIC
Model: Rapid Diagnostic HCV 1175 19 BUILDING CIVIL ROAD HARI NAGAR ROHTAK HARYANA 124001 | ROHTAK | HARYANA | 124001 | Make: RAPID DIAGNOSTIC
Model: Rapid Diagnostic HCV | L2 | Qualified | |
| 3 | L3₹20,000+₹6,000 (42.9%)Qualified Make: ATHENESE Dx
Model: Athenese DX 6503 NEHA APARTMENT S J ROAD ATHGAON KAMRUP ASSAM 781001 | KAMRUP METRO | ASSAM | 781001 | Make: ATHENESE Dx
Model: Athenese DX | L3 | Qualified | |
| 4 | L4₹23,500+₹9,500 (67.9%)Qualified Make: VOXPRESS
Model: Voxtur Vox Press HCV I P EXTENSION DELHI DELHI 110092 | EAST DELHI | DELHI | 110092 | Make: VOXPRESS
Model: Voxtur Vox Press HCV | L4 | Qualified | |
| 5 | L5₹29,000+₹15,000 (107.1%)Qualified Make: JMitra
Model: J-MITRA (TRI-DOT) C 11 1ST FLOOR C BLOCK COMMUNITY CENTRE JANAKPURI NEW DELHI 110058 DELHI DELHI 110045 | WEST DELHI | DELHI | 110058 | Make: JMitra
Model: J-MITRA (TRI-DOT) | L5 | Qualified |
Tender Value
Refer Docs
EMD Value
Exempted
Closing Date
9 Oct 2018, 2:00 pmClosed
Portable Mobile Test Kit ( 500 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL Type of Test Kit Portable/Mobile Pathological Diagnostic Test Kit * Main items in test kit for performing the tests Card Device
Card
Strip
Device & Card
Device
Card and Strip
Device and Strip
Card and Strip Clean
dry sterilized sample collection container present with the kit Yes * Dropper Present true true
false Other accessories and spares if any for standard pack in the kit N0 * Test kit container for housing all the items Yes * Number of tests those can be performed using the 1 Any applicable numeric value 1/5 kit TECHNICAL FEATURES Principle Detection of Pathological tests * Type of Centrifugation unit No * Technical specification of Centrifugation unit provided HCV Kit Pkt of 100 test * Presence of Silica granules (These granules do not play any role in the detections of tests
but they absorb the moisture so that the Card/Strip do not get spoiled) YES * FUNCTIONAL FEATURES Serology test for Widal false true
false Serology test for IgM false true
false Serology test for Maleria Antigen false true
false Serology test for Dengue NS1 Antigen false true
false Serology test for HBSAG false true
false Serology test for HCV true true
false Serology test for VDRL false true
false Serology test for RA FACTOR false true
false Serology test for CRP false true
false Serology Test for PREGNANCY (HCG) false true
false Serology test for Semen Analysis false true
false Serology test for Semen Fructose false true
false Urine test for Leukocyte false true
false Urine test for Nitrite false true
false Urine test for Bilinogen false true
false Urine test for Protein false true
false 2/5 Urine test for Ph false true
false Urine test for Specific gravity false true
false Urine test for Ketone false true
false Urine test for Bilurubin false true
false Urine test for Glucose false true
false Urine Test for Pregnancy(HCG) false true
false Urine test for Appearance false true
false Urine test for Color false true
false Urine test for Reaction false true
false Urine test for Bacteria false true
false Test for Fasting Blood Sugar false true
false Test for Random Blood Sugar false true
false Test for Post Prondtle (PP) Blood Sugar false true
false PACKING Type of packing Individual kit separately packed * CERTIFICATIONS Submission of Test Report on Form 39 or from Central Govt/NABL/ILAC accredited Lab or from Manufacturer's inhouse Test Report to prove the conformity to declared specification at the time of supply YES * Certification available ISO * Cerfification of Centrifugation unit NA * Submission of all the certificates to the buyer along with supplies on demand YES * Availability of valid Drug License YES * Drug License No 1650 * 3/5 Drug License Date 14/02/2020 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Kumar N 131305
BHAGAT PHOOL SINGH MAHILA VISHWAVIDYALAYA
KHANPUR KALAN 500 15
675340
GEM/2018/B/95749
GeM Contract
Portable Mobile Test Kit
GeM Contract
15 days
Haryana; Sonipat
PRODUCT
Awarded to TRACK MANUFACTURING CO. PRIVATE LIMITED
₹14,000
| Product | Brand / Model | HSN | Quantity | Unit Price | Amount |
|---|---|---|---|---|---|
| HCV CARDS | 10RT10410 | - | 500 NOS | ₹28 | 14,000 |
| Item | Delivery Location | Qty | Delivery |
|---|---|---|---|
| Portable Mobile Test Kit ( 500 ) Technical Specifications * As per GeM Category Specification Specification Specification Name Values Allowed Values GENERAL Type of Test Kit Portable/Mobile Pathological Diagnostic Test Kit * Main items in test kit for performing the tests Card Device | - | - | - |
| Card | - | - | - |
| Strip | - | - | - |
| Device & Card | - | - | - |
| Device | - | - | - |
| Card and Strip | - | - | - |
| Device and Strip | - | - | - |
| Card and Strip Clean | - | - | - |
| dry sterilized sample collection container present with the kit Yes * Dropper Present true true | - | - | - |
| false Other accessories and spares if any for standard pack in the kit N0 * Test kit container for housing all the items Yes * Number of tests those can be performed using the 1 Any applicable numeric value 1/5 kit TECHNICAL FEATURES Principle Detection of Pathological tests * Type of Centrifugation unit No * Technical specification of Centrifugation unit provided HCV Kit Pkt of 100 test * Presence of Silica granules (These granules do not play any role in the detections of tests | - | - | - |
| but they absorb the moisture so that the Card/Strip do not get spoiled) YES * FUNCTIONAL FEATURES Serology test for Widal false true | - | - | - |
| false Serology test for IgM false true | - | - | - |
| false Serology test for Maleria Antigen false true | - | - | - |
| false Serology test for Dengue NS1 Antigen false true | - | - | - |
| false Serology test for HBSAG false true | - | - | - |
| false Serology test for HCV true true | - | - | - |
| false Serology test for VDRL false true | - | - | - |
| false Serology test for RA FACTOR false true | - | - | - |
| false Serology test for CRP false true | - | - | - |
| false Serology Test for PREGNANCY (HCG) false true | - | - | - |
| false Serology test for Semen Analysis false true | - | - | - |
| false Serology test for Semen Fructose false true | - | - | - |
| false Urine test for Leukocyte false true | - | - | - |
| false Urine test for Nitrite false true | - | - | - |
| false Urine test for Bilinogen false true | - | - | - |
| false Urine test for Protein false true | - | - | - |
| false 2/5 Urine test for Ph false true | - | - | - |
| false Urine test for Specific gravity false true | - | - | - |
| false Urine test for Ketone false true | - | - | - |
| false Urine test for Bilurubin false true | - | - | - |
| false Urine test for Glucose false true | - | - | - |
| false Urine Test for Pregnancy(HCG) false true | - | - | - |
| false Urine test for Appearance false true | - | - | - |
| false Urine test for Color false true | - | - | - |
| false Urine test for Reaction false true | - | - | - |
| false Urine test for Bacteria false true | - | - | - |
| false Test for Fasting Blood Sugar false true | - | - | - |
| false Test for Random Blood Sugar false true | - | - | - |
| false Test for Post Prondtle (PP) Blood Sugar false true | - | - | - |
| false PACKING Type of packing Individual kit separately packed * CERTIFICATIONS Submission of Test Report on Form 39 or from Central Govt/NABL/ILAC accredited Lab or from Manufacturer's inhouse Test Report to prove the conformity to declared specification at the time of supply YES * Certification available ISO * Cerfification of Centrifugation unit NA * Submission of all the certificates to the buyer along with supplies on demand YES * Availability of valid Drug License YES * Drug License No 1650 * 3/5 Drug License Date 14/02/2020 * * Bold specifications are the golden parameters. Consignees and Quantity S.No. Consignee Address Quantity Delivery Days 1 Anil Kumar N 131305 | - | - | - |
| BHAGAT PHOOL SINGH MAHILA VISHWAVIDYALAYA | - | - | - |
| KHANPUR KALAN 500 15 | - | - | - |
Exempted
22 Oct 2018
9 Oct 2018
contract_GEMC-511687769891371.pdf
GEM_CONTRACT • 0.02 MB
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
bid_675340.pdf
GEM_BID
termsCondition.pdf
OTHER
2657c7ca70287299b5181580fdb5a7ab.pdf
OTHER
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .