Chief Engineer (Project and R&C)
Site Survey, Designing, Engineering, Procurement, Supply, Loading, Transportation, Unloading, Insurance, Delivery at Site, Handling, Storage, Installation, Testing, Commissioning Including Documentation of All Items/Material required to complete works for Turnkey Based Contract For Conversion of Existing 11 kV HT Line and LT Line Network Including Consumer Service Lines Into Under Ground Cable Network With Ring Main System at Adhewada Subdivision of Bhavnagar Circle Under PGVCL with GIS Mapping / Geo Urja Mapping (Developed by GUVNL) and Asset Tagging under SI Scheme (Package-18)
249401
PGVCL/PROJ/UGBVN-2/ADH/P18/146
Open
Supply,erection and Commissioning
Rajkot
21 documents required · 20 mandatory · 1 optional
₹17,700
PASCHIM GUJARAT VIJ COMPANY LIMITED, Rajkot
₹1.3 Cr
5 Dec 2025
5 Dec 2025
5 Dec 2025
29 Jan 2026
5 Dec 2025
Conversion of Over Head to Underground Network
Adhewada Sub Division of Bhavnagar city-2 Division of Bhavnagar Circle
Particulars of Item Grand Total in Rs.
Particulars of Item Grand Total in Rs.
SCHEDULE-B1: CONVERSION OF EXISTING OVERHEAD ELECTRICAL HT
NETWORK IN TO UNDERGROUND CABLE NETWORK
a FOR SUPPLY PART
b FOR ERECTION PART
SCHEDULE-B2: CONVERSION OF EXISTING OVERHEAD ELECTRICAL LT
NETWORK IN TO UNDERGROUND CABLE NETWORK
a FOR SUPPLY PART
b FOR ERECTION PART
A TOTAL AMOUNT (WITHOUT GST)
A TOTAL AMOUNT (WITHOUT GST)
3 BIDDER'S OFFER ( + / - ) IN % 0.00%
4 BIDDER'S OFFER ( + / - ) IN RUPEES
B OFFERED TOTAL AMOUNT FOR SUPPLY AND ERECTION (WITHOUT GST)
B OFFERED TOTAL AMOUNT FOR SUPPLY AND ERECTION (WITHOUT GST)
5 GST @ 18% ON "B"
C GRAND TOTAL (WITH GST)
C GRAND TOTAL (WITH GST)
Date Signature of Bidder Stamp
SCHEDULE-B: CONVERSION OF OVERHEAD TO UNDERGROUND ELECTRICAL NETWORK
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
SCHEDULE-B1: CONVERSION OF OVERHEAD TO UNDERGROUND HT ELECTRICAL NETWORK
RMU : Supply, installation, testing & Commissioning of 11 KV SCADA,
Non-SCADA Ring Main Unit SF6 Gas Insulated as under preferably
1 Siemens/ Schneider/ABB/CG. (Including RCC foundation, masonry and
all civil works, as per approve drawing by PGVCL)
a SF6 Ring Main Unit with SCADA switching facility 630 A extensible.
i 11KV SCADA RING MAIN UNIT 3 ISOLATOR (3-WAY) Nos. 2 527678 1055355 2 10751.35 21502.7
11KV SCADA RING MAIN UNIT 1 CIRCUIT BREAKER 2 ISOLATOR (3-
11KV SCADA RING MAIN UNIT 1 CIRCUIT BREAKER 3 ISOLATOR (4-
11KV SCADA RING MAIN UNIT 2 CIRCUIT BREAKER 2 ISOLATOR (4-
Distribution Transformer: Supply, installation, testing & commissioning
of 11/0.433KV, Outdoor Transformers with HV/LV cable end Boxes and
CTs commissioned at LV end boxes for the following ratings
(Transformer shall be suitable for pole mounting/Plinth mounting/
Structure upto 500 kVA (Including plinth/structure) as per standard
technical specification
a 200 KVA CRGO/Amorphous core Nos. 49 404968 19843427.1 49 14297.95 700599.55
b 315 KVA CRGO/Amorphous core Nos. 35 1023686 35829020.5 35 14297.95 500428.25
c 500 KVA CRGO/Amorphous core Nos. 44 1135362 49955912.6 44 14297.95 629109.8
Supply,installation,Testing & commissioning of 11 kV,(E),XLPE
insulated Aluminium Conductor, Armoured cable, Sand as per
a enclosed specification, including rates for approval of local Authorities
for laying of cable.(Make as approved by GUVNL) With excavations
and, back filling as per specification
Providing and Laying of HDPE ducts confirming to IS:4984 having dia.
OD/ID 140/100.mm, 6kg/cm2, 11.63 kg/6 RMT at a minimum depth of
1200mm below the road surface by push through method by drilling the road
4 with HDD machine without breaking the road surface for laying of cable for Mtrs. 6665 604 4023993.75 6665 949 6323418.75
internal GIDC road crossing for enclosing HT/LT XLPE insulated aluminum
armoured cable up to 300 sqmm through the duct as per the instructions of
EIC (Engineer In Charge).
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
OUTDOOR TERMINATION KIT: HT push on/heat shrink type end
termination preferably 3m(m-seal) or Raychem make at switchgear end
boxes, transformer(PAD/Pole mounted) for 3 core 11 kV XLPE
5 Aluminium Conductor Armoured cable as specified with connection of
leads including cutting, stripping of cable, insulations, providing
compression type terminals, crimping of lugs with suitable crimping
tool for outdoor application
INDOOR TERMINATION KIT : HT push on/heat shrink type end
termination preferably 3m(m-seal) or Raychem make at switchgear end
boxes, transformer (PAD/Pole mounted) for 3 core 240 Sq mm 11 kV
6 XLPE Aluminium Conductor Armoured cable as specified with
connection of leads including cutting, stripping of cable, insulations,
providing compression type terminals, crimping of lugs with suitable
crimping tool for Indoor application
G:STRIGHT JOINT KIT: HT push on/heat shrink type straight joint
preferably 3m(m-seal) or Raychem make for up to 3 core 300/240/185
Sq mm 11 kV XLPE Aluminium Conductor Armoured cable as specified
with connection of leads including cutting, stripping of cable,
insulations, providing compression type terminals, crimping of lugs
with suitable crimping tool.
8 Lying of all types of cable in trench(without Excavation) Mtrs. 1347.42 173 232429.95
9 Lying of cable on pole Mtrs. 896 44 39155.2
10 Lying of the cable in the Pipe(Without Excavation) 67.371 58 3873.8325
11 Drilling work in Road Crossing through push through Mtrs. 67.371 569 38350.94175
Drilling work in Road/ASPH/RCC /Hard Rock Etc(Excavation with back
filling as per the specification of cable lying)
Supply and fixing of GI Pipe on wall/Pole (100 mm Dia Medium Duty pipe
13 with rubber gland at both ends to avoid cable damages). This includes Mtrs. 640 403 257600 640 230 147200
providing and fixing of M.S clamp at every 1 Mtr.(As per Directive of EIC)
Supply and installation of any clamps made from 50x6 mm GI flat for
14 fiiting100 mm dia medium class GI pipe/any other pipes above ground with Pair 512 115 58880 512 35 17664
Supply, Installation, Testing, Commissioning of Half Round pipe(1000mm
Length, 6 inch dia, 1 inch thick)
PRE BONDING TAP: For laying on trench after laying cable on trech to
16 provide indication cable route below land surface in underground trench to Mtrs. 67371 17 1162149.75 67371 6 387383.25
protect cable for mechnical injuries.
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
CABLE TERMINAL FERRULS: The PVC Cable terminal ferruls for
identification of phase sequence and feeder/PSS/FSP name of HT/LT
17 cables shall be provided at every termination of all cables stating detail as Nos 318 28 8776.8 318 9 2925.6
under. HT Cable :Feeder name/Phase(R/Y/B) LT Cable : TC/FSP
name/Phase(R/Y/B/N)
CABLE TAG: The PVC tag for identification of feeder/PSS/FSP/RMU name
of HT/LT cables shall be provided at every 150 MTR
HT Feeder: Substation/Feeder LT Feeder
: PSS/Transformer/FSP
EARTHING PIT : Supplying & erecting earth pit of minimum bore dia.
mm size approved make safe Earthing Electrode consisting Pipe in pipe
Technology as per IS 3043-1987 made of corrosion free G.I. Pipes having
Outer pipe dia of 50 mm having 80-200 Micron galvanising connections,
19 terminal dia. of 12 mm with constant ohmic value surrounded by highly Nos. 446 7475 3333850 446 1150 512900
conductive compound with high charge dissipation with civil works of
earthing chamber. For Electrical installation covering Transformer neutrals,
HT & LT switchgears for independent earthing in normal soil, Length of Pipe
3 mtrs. Backfilling compound 2 bags of 25 Kg each.
Supply installation & commissioning of earthing conductor 38 x 3 G.I. strip
20 for pole mounted transformer and RMU Etc as well as connection to be Mtrs. 1338 159 212340.6 1338 60 80012.4
made to the earth pit. Rates inclusive of hot dipped hardwares.
Obtaining statutory approval from Electrical Inspector for installation
22 DISMENTALLING:
Dismentalling of pole mounted transformer,stacking the same after
transporting to discom store without any damage as and where condition.
a Up To 500 KVA Nos. 332 2875 954500
b Above 500 KVA Nos. 1 4025 4025
Dismentallling RCC/Rail pole with cross arm,insulators,hardwares,stay,
23 etc.and return it to discom store.While dismentalling utmost care shall be Nos. 3095 155 480498.75
taken so that the material so that the same can be reused by discom.
Dismentalling of AAAC/ACSR/ABC/ Earth wire any size of conductor & line
24 material & after making coil and stacking the same at discom store.Routte Km. 59.45 2300 136735
Dismentalling of any type of service connection from the site and material
return to DISCOM store as per directive of EIC
CABLE ROUTE MARKER: Providing and erecting RCC cable route marker
26 as per drawing duly marked with "DANGER" mark, "discom POWER Nos 674 345.00 232530 674 115.00 77510
CABLE" and arrow of route of cable.
DRAWING: Preparing complete drawing of entire network as well as
individual feeder map showing joints also in AutoCad and providing the
same to PGVCL in AutoCad copy as ell as pdf copy and hard copy in six
sets. The drawing should be geographical indicating all directions
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
FENCING: FRP Fencing for RMU and PSS, post shall be made out of FRP
Pultruded hollow section of size 50x50x5mm.. and shall be grouted in the
ground with c. c. of ratio 1:3:6., Sub frame provided using hollow FRP
a section 50x25x5mm or FRP angles 50x50x5 at top and bottom and other RMT 2067 4,012.58 8294002.86 2067 794.8225 1642898.108
accessories for fixing of gates etc. Rails shall be made out of FRP notch
bars of 12mm dia, Pickets shall be made of flats of size 35x5mm SMC or
FRP as per specifications and Drawing NO: discom/R&D/Fencing/FRP/001
DTC: Fixing of DTC meter at all Transformers Center in such manner that
29 meter reading may be taken easily without obstruction due to fencing of Nos 128 1265 161920
RMU (excluding Meter/Meter Box/Cable)
Paint Pointed Letter 2 inch size(Marking on RMU, Transformer, In any
palce.(As per directive of Engineer Incharge) with supply of color
31 Insulation Resistance Tester for Cable testing 10KVA-SDN wise Nos. 1 8050 8050
Total HT-UG (Supply+ Erection) 294302006 41420268
SCHEDULE-B2: CONVERSION OF OVERHEAD TO UNDERGROUND LT ELECTRICAL NETWORK
Providing & erecting XLPE(IS:7098) (I)-88 ISI marked multistrand Aluminium
conductor armoured cable ,sand for 1.1 kV to be laid on pole or in existing
cable trence/pipe at road crossing of following size of cables. Work carried
1 out up to consumer premises with meter shifting, and provide load side
cable as per site conditions and as per EIC. For consumer premises DWC
pipe should be provieded(With Excavation, back filling and sand as per
technical specification)
LT CABLE TERMINATION: Cable termination on FSP,LT Distribution
Transformer Box,MSP/SFU /Busbar etc of pole mounted transformer of LT
cable grade as specified below including cutting,stripping of
cable,insulations,providing compression type terminals,suitable cable
glands,crimping lugs with necessary connections.Work carried out up to
consumer premises with meter shifting, and provide load side cable as per
site conditions and as per EIC. For consumer premises DWC pipe should
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
l 1 core 300 Sq mm(TC to FSP) Nos. 256 1432 366528 256 52 13248
3 Lying of all types of cable in trench(without Excavation) Mtrs. 26172 173 4514670
4 Lying of cable on pole Mtrs. 430.5 44 18812.85
5 Lying of the cable in the Pipe(Without Excavation) 261.72 58 15048.9
6 Drilling work in Road Crossing through push through Mtrs. 2152.5 569 1225310.625
Drilling work in Road/ASPH/RCC /Hard Rock Etc(Excavation with back
filling as per the specification of cable lying)
8 Supply, intstallation of the DWC pipe(Without Excavation)
Lt cable saddling works: Direct cable saddleing with wall and etc for this
work GI type saddle and nail shall be used.
Supply, Installation, Testing, Commissioning of Half Round pipe(1000mm
Length, 4 inch dia, 1 inch thick)
PRE BONDING TAP: For laying on trench after laying cable on trech to
11 provide indication cable route below land surface in underground trench to Mtrs. 34440 17 594090 34440 6 198030
protect cable for mechnical injuries.
CABLE TERMINAL FERRULS: The PVC Cable terminal ferruls for
identification of phase sequence and feeder/PSS/FSP name of HT/LT
12 cables shall be provided at every termination of all cables stating detail as Nos 18480 28 510048 18480 9 170016
under. HT Cable :Feeder name/Phase(R/Y/B) LT Cable : TC/FSP
name/Phase(R/Y/B/N)
CABLE TAG: The PVC tag for identification of feeder/PSS/FSP/RMU
13 name of HT/LT cables shall be provided at every 30 MTR Nos. 8724 28 240782.4 8724 9 80260.8
HT Feeder: Substation/Feeder LT
Feeder : PSS/Transformer/FSP
EARTHING PIT : Supplying & erecting earth pit of minimum bore dia.
mm size approved make safe Earthing Electrode consisting Pipe in pipe
Technology as per IS 3043-1987 made of corrosion free G.I. Pipes having
Outer pipe dia of 50 mm having 80-200 Micron galvanising connections,
14 terminal dia of 12 mm with constant ohmic value surrounded by highly Nos. 4620 7475 34534500 4620 1150 5313000
conductive compound with high charge dissipation with civil works of
earthing chamber. For Electrical installation covering Transformer
neutrals,HT & LT switchgears for independent earthing in normal soil,
Length of Pipe 3 mtrs.Backfilling compound 2 bags of 25 Kg each.
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Supply installation & commissioning of earthing conductor 38 x 3 G.I. strip
for pole mounted transformer and upto FSP,RMU,MSP,SFU, Busbar Etc as
well as connection to be made to the earth pit. Rates inclusive of hot dipped
Obtaining statutory approval from Electrical Inspector for installation
17 DISMENTALLING:
Dismentallling RCC/Rail pole with cross arm,insulators,hardwares,stay,
a etc.and return it to discom store.While dismentalling utmost care shall be Nos. 2415 155 374928.75
taken so that the material so that the same can be reused by discom.
Dismentalling of AAAC/ACSR/ABC/ Earth wire any size of conductor & line
b material & after making coil and stacking the same at discom store.Routte Km. 96.58012119 2300 222134.2787
Dismentalling of any type of service connection from the site and material
return to DISCOM store as per directive of EIC
FSP (FUSE SECTION PILLER): 4 Way
Supplying and erecting 120x100x40 cms. Fuse section pillar fabricated from
4 mm Thermosetting Plastic ( moulded in a single piece ) i.e Glass
Reinforced Polyester sheet Moulding Compound (SMC ) or metal body(As
per Specification and drawings) with cable clamps to be burried in ground
to have appropriate erection on look unifrom unit erected with cement
concrete foundation and 45 cms high brick masonry internal supported on
i both side with intrnal and outer side locking arrangement with lock and keys
in duplicate .Incoming switchgear SFU of TPN and outgoing HRC SMC
fuse base and knife type links 32 Amp to 630 Amp capacity fuse base fitted
on 630 Amp current capacity copper Busbar with RYB colour coding and
insulated strip with all internal connections and entry for incomming up to
core 300 sq mm 4 nos and outgoing 3 nos. 31/2 core cables of suitable
sizes. (As per Technical specification of FSP ) (Erection shall be carried out
as per approved drawing and site condition) (SFU Amp Capcity is as under)
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
FSP (FUSE SECTION PILLER): 6 Way
Supplying and erecting 120x100x40 cms.Fuse section pillar fabricated from
4 mm Thermosetting Plastic ( moulded in a single piece ) i.e Glass
Reinforced Polyester sheet Moulding Compound (SMC ) or metal body(As
per Specification and drawings) with cable clamps to be burried in ground to
have appropriate erection on look unifrom unit erected with cement concrete
foundation and 45 cms high brick masonry internal supported on both side
ii with intrnal and outer side locking arrangement with lock and keys in
duplicate .Incoming switchgear SFU of TPN and outgoing HRC SMC fuse
base and knife type links 32 Amp to 630 Amp capacity fuse base fitted on
630 Amp current capacity copper Busbar with RYB colour coding and
insulated strip with all internal connections and entry for incomming 1 core
300 sq mm 4 nos and outgoing 5 nos. 31/2 core cables of suitable sizes.
(As per Technical specification of FSP ) (Erection shall be carried out as
per approved drawing and site condition)(SFU Amp Capcity is as under)
MSP(Mini Section Piller) : 4 Way
Supplying and erecting 120x100x40 cms. Mini section pillar
fabricated from 4 mm thick Thermosetting Plastic(moulded in a single
piece) i.e. Glass Reinforced Polyester Sheet Moulding Compound
(SMC) or Metal Body Type Enclouser(As per Specification) with cable
clamps to be burried in ground to have appropriate erection on look
uniform unit erected with cement concrete foundation and 45 cms
high brick masonary internal supported on both side with internal and
outer side locking arrangement with lock and keys in duplicate.
Incoming HRC SMC fuse base and kinfe type links 32 Amp to
Amp. capacity, fuse base fitted on 250 Amp. current capacity copper
Busbar with RYB colour coding and insulated strip with all internal
connections and entry for incoming up to 3.5 Core 300 Sq.mm 1 Nos.
and outgoing 3 nos. 3.5 core cables of suitable sizes.( As per
Technical specification of MSP)
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
MSP(Mini Section Piller) : 6 Way
Supplying and erecting 120x100x40 cms. Mini section pillar
fabricated from 4 mm thick Thermosetting Plastic(moulded in a single
piece) i.e. Glass Reinforced Polyester Sheet Moulding Compound
(SMC) or Metal Body Type Enclouser(As per Specification) with cable
clamps to be burried in ground to have appropriate erection on look
uniform unit erected with cement concrete foundation and 45 cms
high brick masonary internal supported on both side with internal and
outer side locking arrangement with lock and keys in duplicate.
Incoming HRC SMC fuse base and kinfe type links 32 Amp to
Amp. capacity, fuse base fitted on 250 Amp. current capacity copper
Busbar with RYB colour coding and insulated strip with all internal
connections and entry for incoming up to 3.5 Core 300 Sq.mm 1 Nos.
and outgoing 5 nos. 3.5 core cables of suitable sizes.( As per
Technical specification of MSP)
MSP(Mini Section Piller) : 8 Way
Supplying and erecting 120x100x40 cms. Mini section pillar
fabricated from 4 mm thick Thermosetting Plastic(moulded in a single
piece) i.e. Glass Reinforced Polyester Sheet Moulding Compound
(SMC) with cable clamps to be burried in ground to have appropriate
erection on look uniform unit erected with cement concrete
foundation and 45 cms high brick masonary internal supported on
iii both side with internal and outer side locking arrangement with lock
and keys in duplicate. Incoming HRC SMC fuse base and kinfe type
links 32 Amp to 250 Amp. capacity, fuse base fitted on 250 Amp.
current capacity copper Busbar with RYB colour coding and insulated
strip with all internal connections and entry for incoming up to
Core 300 Sq.mm 1 Nos. and outgoing 7 nos. 3.5 core cables of
suitable sizes.( As per Technical specification of MSP)
Supply, Instalation, Testing, Commissioning switch fuse unit made by
SMC Box and capacity of 125 A, Mostaly used in flat/Socity area.
20 Installation worked caried out with instruction of EIC. And as per the Nos. 1191 12087 14395021.5 1191 1150 1369650
drawing approved by CA- Minimum 16 Nos. of CKT
Sr. Total Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
Particulars of Item Unit Supply Qty. Unit Rate in Rs Erection Qty. Unit Rate in Rs Grand Total
SFU: Supply, Instalation, Testing, Commissioning switch fuse unit
made by SMC box and capacity of 200 A, Mostaly used in flat area.
21 Installation worked caried out with instruction of EIC. And as per the Nos. 340 18400 6256000 340 1150 391000
drawing approved by CA - Minimum 16 Nos. Of Circuit
SFU: Supply, Instalation, Testing, Commissioning switch fuse unit
made by SMC box and capacity of 400 A, Mostaly used in flat area.
22 Installation worked caried out with instruction of EIC. And as per the Nos. 170 20700 3519000 170 1323 224825
drawing approved by CA- Minimum 16 Nos. Of Circuit
CABLE ROUTE MARKER: Providing and erecting RCC cable route marker
23 as per drawing duly marked with "DANGER" mark, "discom POWER Nos 391 345.00 134964 391.2 115.00 44988
CABLE" and arrow of route of cable.
DRAWING: Preparing complete drawing of entire network as well as
individual feeder map showing joints also in AutoCad and providing the
same to PGVCL in AutoCad copy as ell as pdf copy and hard copy in six
sets. The drawing should be geographical indicating all directions
FENCING: FRP Fencing for FSP/MSP/SFU/BUSBAR, post shall be made
out of FRP Pultruded hollow section of size 50x50x5mm.. and shall be
grouted in the ground with c. c. of ratio 1:3:6., Sub frame provided
a using hollow FRP section 50x25x5mm or FRP angles 50x50x5 at top RMT 116 4,012.58 465459.28 116 795.225 92246.1
and bottom and other accessories for fixing of gates etc. Rails shall be
made out of FRP notch bars of 12mm dia, Pickets shall be made of flats
of size 35x5mm SMC or FRP as per specifications
Paint Pointed Letter 2 inch size(Marking on FSP, MSP, SFU Etc In any
palce.(As per directive of Engineer Incharge) with supply of color
27 HRC Fuse and its Fuse base(Spare)
28 Jointing Kit for LT Cable
Total LT-UG (Supply+ Erection) 181562968 31847654
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
RAW_HTML
1. Part-I P-18-146.pdf
2.Employers requirement.pdf
3. Technical Specifications.pdf
4. CoC- P18-146.pdf
5. Declaration of Authorised person and Confict of Interest.pdf
6. Reference Tender Drawing Robust Network.pdf
7. Schedule-B-UGBVN 2-ADH-P18-146.pdf
TLE -Amendment-1.pdf
TLE -Amendment-2.pdf
TLE -Amendment-3.pdf
TLE -Amendment-4.pdf
Download all tender documents and submit your bid