| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹22.3 LAccepted-AOC | ₹22.3 L | L1 | Accepted-AOC Lowest |
| 2 | L2₹22.3 L+₹2,735.60 (0.12%)Rejected-AOC LUDHIANA | LUDHIANA | PUNJAB | 141001 | ₹22.3 L+₹2,735.60 (0.12%) | L2 | Rejected-AOC Not Lowest |
| 3 | Not Admitted-Fee/PreQual/Technical | - | - | Not Admitted-Fee/PreQual/Technical Others-EMD not paid and Authorization is not valid |
Tender Value
₹22.7 L
EMD Value
₹45,500
Closing Date
18 Nov 2024, 1:00 pmClosed
Executive Engineer (Elect.)
Executive Engineer (Elect.), Thapar Hall, PAU, Ludhiana
Providing/Installation of Ductable Air Conditioners at Manmohan Singh Auditorium PAU, Ludhiana
2024_PAU_129503_5
Endst. No. 1881-86 Dated- 06.11.2024
Open Tender
Electrical Works
Multi-stage
183 days
PAU
Please refer Tender documents.
3 documents required · 3 mandatory
₹1,180
₹45,500
Yes
25 Nov 2024
6 Nov 2024
19 Nov 2024
6 Nov 2024
18 Nov 2024
6 Nov 2024
Amount
Supply, Installation, Testing and commissioning of hard/soft copper refrigerant piping for 16.5 Tr Ductable complete with fittings, elbows, bends, supporting arrangement on walls 7/8inch x1/2 inch complete in all respect as approved by the Engineer-in-charge at site. (Make:Totalline,Max flow,Cami pro,Mander)
Supply, fabrication and installation of MS base frame for outdoor units of 16.5 Tr Ductable ODU ,Size 35mmx5mm complete in all respect as approved by the Engineer-in-charge at site.
Supply, Installation, Testing and commissioning of MS base frame for indoor units of 16.5 Ductable IDU (16.5*1)Size 50mmx8mm complete in all respect as approved by the Engineer-in-charge at site.
Supply, Installation, Testing and commissioning of 20 Guage ducting complete with, supports, dampers, and turning vanes complete in all respect as approved by the Engineer-in-charge at site. (Make:Tata/Sail/Jindal/AMNS)
Supply, Installation, Testing and commissioning of 22 Guage ducting complete with, supports, dampers, and turning vanes complete in all respect as approved by the Engineer-in-charge at site. (Make:Tata/Sail/Jindal/AMNS)
Supply, Installation, Testing and commissioning of 24 Guage ducting complete with, supports, dampers, and turning vanes complete in all respect as approved by the Engineer-in-charge at site. (Make:Tata/Sail/Jindal/AMNS)
Supply, Installation, Testing and commissioning of Flexible double canvass connections for packaged air conditioners complete in all respect as approved by the Engineer-in-charge at site.
Supply, Installation, Testing and commissioning of 6” / 8” wide linear grilles, aluminium, powder coated complete in all respect as approved by the Engineer-in-charge at site. (Make:Uniair/carrier/systemair/Superlon)
Supply, Installation, Testing and commissioning of Alluminum construction I-Ball Type Diffuers complete in all respect as approved by the Engineer-in-charge at site. (Make:uniair/ Carrier/systemair/Superlon)
Supply, Installation, Testing and commissioning ofThermal Duct Insulation with 9 mm thick closed cell niterial rubbar complete in all respect as approved by the Engineer-in-charge at site. (Make:A-flex,K-flex,systemair)
Supply, Installation, Testing and commissioning of Acoustic lining of duct work with 12mm thick 300 fiberglass stick using shalikote primer hot bitumen and mechanically fastened, covered with RP tissue. Acoustic lining shall be rigid board complete in all respect as approved by the Engineer-in-charge at site. (Make:Twiga)
Supply, Installation, Testing and commissioning of 16.5 TR Ductable Air Conditioning unit. Each consists of single Indoor unit and single/double Outdoor unit. With airflow more than 6300 CFM. Static pressure should not be less than 80 Pa. Sound pressure level should be less than 60 dBA. Machine should run at 415V / 3phase / 50 Hz. The unit to be controlled with wired remote. it should be factory charged with R410A refrigerent and should be operate at 52oC complete in all respect as approved by the Engineer-in-charge at site. (Make Hitachi/ Daikin/ Mitsubishi/ O General)
S/E of Single phase light weight HVLS ceiling fan 16' IP67,copper wire H class insulation,Super Slient noise level ≤38DB,Air+Liquied cooled motor,Anti vibration blades,steel wire traction system ,Self lubicrated bearing structure, Traction device, shaft safety, small size ,protection System with overloaded/lack of phase/overvoltage/ ,Temperature Sensors are connected from controller of motor inculding scafolding input power supply complete in all respect as approved by the Engineer-in-charge at site. (Make:Marut air /Austar/Mg fans/Sunon/Eagle)
Supply and erection of PVC insulated PVC sheathed (4 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (Make: RR/Finolex /Kei) Overall size 4.0sq.mm , 4Core
Supply and erection of PVC insulated PVC sheathed (6 core) round flexible wire with copper conductor (FR) cable (ISI marked) confirm to IS:694/1990 left bare in pipe or casing of suitable size complete in all respect as desired by the Engineer-in-charge:- (Make: RR/Finolex /Kei) Overall size 6.0sq.mm , 6Core
Dismantling/Installation of Existing wooden & fabric panel, civil work for cutting the walls and replastering and all other civil work it required any scafholding for the work at height any other arrangement required to execute the work. complete in all respect as approved by the Engineer-in-charge at site.
RAJNISH ELECTRICALS (BID ID -597143)
RAJNISH ELECTRICALS (BID ID -597143)
stage.html
html • 0.04 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .