Loading…
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹33.7 LAccepted-Finance | L1 | Accepted-Finance Lowest Vendor | |
| 2 | L2₹37.9 L+₹4.2 L (12.4%)Rejected-Finance D NO 29 2 43 SING HOTEL JUNCTION CMR ROAD VISAKHAPATNAM 530 020 | VISAKHAPATANAM | ANDHRA PRADESH | 530020 | L2 | Rejected-Finance Being not L1 | |
| 3 | L3₹39.0 L+₹5.3 L (15.8%)Rejected-Finance D NO 4 96 40 27 FLAT NO 307 GREEN CASTLE APARTMENT GOPALAKRISHNA NAGAR SUJATHANAGAR VISAKHAPATNAM 530 051 | VISAKHAPATANAM | ANDHRA PRADESH | 530051 | L3 | Rejected-Finance Being not L1 | |
| 4 | L4₹40.0 L+₹6.3 L (18.7%)Rejected-Finance 34 10 37 1 GNANAPURAM DAYAS STREET VISAKHAPATNAM VISAKHAPATNAM ANDHRA PRADESH 530004 | VISAKHAPATANAM | ANDHRA PRADESH | 530004 | L4 | Rejected-Finance Being not L1 | |
| 5 | L5₹43.8 L+₹10.1 L (29.9%)Rejected-Finance | L5 | Rejected-Finance Being not L1 |
| Sl No | Description | Qty | Unit | MSN ENGINEERING WORKS L3 | M/S SRI VENKATA BHAVANI CONSTRUCTIONS L7 | SUPREET CONSTRUCTIONS L8 | Power Dynamics L11 | eldi techs L9 | M/s SS Engineering Enterprises L10 | KIRON ENGINEERING CORPORATION L2 | aswitha engineering works L4 | S R CONSTRUCTIONS L5 | UNIVERSAL ENTERPRISES L6 | B.Veerabhadra Rao L1 |
|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
| 1.00 | Dismantling taking out LT/HT/DC cable from cable rack/floor of sub station for repair/replacement of wornout MS cable rack or for realignment of cable and refixing the cables with proper stacking with proper realignment of cable and refixing the cables properly on repaired/existing rack and making feeder wise bundle of cable using PVC cable tie for sizes of cable single core DC cable any size and 3.0/3.5 core 95 sqmm to 185 sqmm 11000/1100 volt grade complete all as specified and as directed
Note : MS cable rack shall be measured separately as supply and fix | 1,000 | RM | 62 ₹62,000 | 180 ₹1,80,000 | 113 ₹1,13,000 | 85 ₹85,000 | 105 ₹1,05,000 | 95 ₹95,000 | 50 ₹50,000 | 60 ₹60,000 | 100 ₹1,00,000 | 74 ₹74,000 | 45 ₹45,000 Lowest |
| 2.00 | All as per item No 1.00 above, but for cable sizes 240 sqmm to 300 sqmm | 2,500 | RM | 64 ₹1,60,000 | 220 ₹5,50,000 | 113 ₹2,82,500 | 115 ₹2,87,500 | 140 ₹3,50,000 | 140 ₹3,50,000 | 60 ₹1,50,000 | 60 ₹1,50,000 | 100 ₹2,50,000 | 80 ₹2,00,000 | 50 ₹1,25,000 Lowest |
| 3.00 | All as per item No 1.00 above, but for cable sizes 400 sqmm to 500 sqmm | 4,200 | RM | 74 ₹3,10,800 | 300 ₹12,60,000 | 113 ₹4,74,600 | 175 ₹7,35,000 | 170 ₹7,14,000 | 170 ₹7,14,000 | 70 ₹2,94,000 | 70 ₹2,94,000 | 100 ₹4,20,000 | 95 ₹3,99,000 | 60 ₹2,52,000 Lowest |
| 4.00 | Dismantling taking out old dead/defective cable of any size 95sqmm to 500 sqmm/dc cable complete all as specified and as directed. | 1,500 | RM | 59 ₹88,500 | 80 ₹1,20,000 | 123 ₹1,84,500 | 100 ₹1,50,000 | 90 ₹1,35,000 | 100 ₹1,50,000 | 50 ₹75,000 Lowest | 80 ₹1,20,000 | 100 ₹1,50,000 | 54 ₹81,000 | 60 ₹90,000 |
| 5.00 | Supply and fix of LT cable end termination for cable sizes 95 to 185 Sq mm, 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing/new all as specified and directed. | 40 | Each | 380 ₹15,200 | 900 ₹36,000 | 1,399.45 ₹55,978 | 1,000 ₹40,000 | 1,250 ₹50,000 | 1,250 ₹50,000 | 600 ₹24,000 | 1,250 ₹50,000 | 700 ₹28,000 | 1,872 ₹74,880 | 300 ₹12,000 Lowest |
| 6.00 | Supply and fix of LT cable end termination for cable sizes 240 to 500 Sq mm, 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing/new all as specified and directed. | 160 | Each | 550 ₹88,000 | 1,500 ₹2,40,000 | 2,210 ₹3,53,600 | 1,250 ₹2,00,000 | 1,500 ₹2,40,000 | 1,500 ₹2,40,000 | 600 ₹96,000 | 1,600 ₹2,56,000 | 1,000 ₹1,60,000 | 2,429 ₹3,88,640 | 399 ₹63,840 Lowest |
| 7.00 | Supply and fix MS cable support structure made with ISA 75x75x8mm grouted to gallery wall with angle fastner bolt of dia not less than 16 mm to 25 mm ,painting the MS structure with one coat of red oxide primer and two coat of synthetic enamel paint complete including taking out old UNSV cable support structure from the jetty gallery complete all as specified and as directed. | 6,000 | Kg | 100 ₹6,00,000 | 160 ₹9,60,000 | 123 ₹7,38,000 | 185 ₹11,10,000 | 130 ₹7,80,000 | 130 ₹7,80,000 | 95 ₹5,70,000 | 75 ₹4,50,000 Lowest | 100 ₹6,00,000 | 119 ₹7,14,000 | 99 ₹5,94,000 |
| 8.00 | M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmens complete all as specified and as directed including taking out of old unserviceable MS cable cover/support structure.Grade of steel Fe 410 -W (Gde E- 250) quality -A structure all as specified and directed. | 2,000 | Kg | 100 ₹2,00,000 | 90 ₹1,80,000 Lowest | 131 ₹2,62,000 | 175 ₹3,50,000 | 125 ₹2,50,000 | 125 ₹2,50,000 | 98 ₹1,96,000 | 90 ₹1,80,000 Lowest | 100 ₹2,00,000 | 105 ₹2,10,000 | 99 ₹1,98,000 |
| 9.00 | M&L for fixing Galvasnized earth strip of size 32mm x 6 mm making drilled hole at both ends and fixing to cope point, PBs, and JBs including taking down old one unserviceable complete all as specified and directed. | 1,500 | RM | 180 ₹2,70,000 | 200 ₹3,00,000 | 167 ₹2,50,500 | 183.5 ₹2,75,250 | 200 ₹3,00,000 | 200 ₹3,00,000 | 150 ₹2,25,000 | 120 ₹1,80,000 | 200 ₹3,00,000 | 180 ₹2,70,000 | 100 ₹1,50,000 Lowest |
| 10.00 | M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. mm 3.5 core including taking out old unserviceable complete all as specified and directed. | 670 | RM | 2,000 ₹13,40,000 | 1,400 ₹9,38,000 Lowest | 2,258.5 ₹15,13,195 | 2,200 ₹14,74,000 | 2,250 ₹15,07,500 | 2,250 ₹15,07,500 | 2,000 ₹13,40,000 | 2,200 ₹14,74,000 | 2,000 ₹13,40,000 | 2,099 ₹14,06,330 | 1,809 ₹12,12,030 |
Tender Value
₹75.0 L
EMD Value
₹1.4 L
Closing Date
5 Dec 2025, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE (I) DM Visakhapatnam
GE (I) DM Visakhapatnam
REPLACEMENT OF UNSV CABLE SUPPORT STRUCTURE REALIGNMENT OF CABLES AT DRYDOCK AND REFIT JETTY COPE POINT GALLERY AND ALLIED WORKS AT NAVAL DOCKYARD VISAKHAPATNAM UNDER GE (I) (DM) VISAKHAPATNAM
2025_MES_738862_1
8361/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
Naval Dockyard Visakhapatnam
As per tender document
8 documents required · 8 mandatory
₹1,000
GE (I) DM VISAKHAPATNAM
₹1.4 L
Yes
27 Jan 2026
7 Nov 2025
8 Dec 2025
7 Nov 2025
5 Dec 2025
28 Nov 2025
8 Nov 2025 - 26 Nov 2025
Dismantling taking out LT/HT/DC cable from cable rack/floor of sub station for repair/replacement of wornout MS cable rack or for realignment of cable and refixing the cables with proper stacking with proper realignment of cable and refixing the cables properly on repaired/existing rack and making feeder wise bundle of cable using PVC cable tie for sizes of cable single core DC cable any size and 3.0/3.5 core 95 sqmm to 185 sqmm 11000/1100 volt grade complete all as specified and as directed Note : MS cable rack shall be measured separately as supply and fix
All as per item No 1.00 above, but for cable sizes 240 sqmm to 300 sqmm
All as per item No 1.00 above, but for cable sizes 400 sqmm to 500 sqmm
Dismantling taking out old dead/defective cable of any size 95sqmm to 500 sqmm/dc cable complete all as specified and as directed.
Supply and fix of LT cable end termination for cable sizes 95 to 185 Sq mm, 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing/new all as specified and directed.
Supply and fix of LT cable end termination for cable sizes 240 to 500 Sq mm, 3.5 core, 1100 volts grade by cutting out damaged portion of XLPE insulated cable ends including disconnection cable ends from ACB/MCCB/Busbar and reconnection with existing/new all as specified and directed.
Supply and fix MS cable support structure made with ISA 75x75x8mm grouted to gallery wall with angle fastner bolt of dia not less than 16 mm to 25 mm ,painting the MS structure with one coat of red oxide primer and two coat of synthetic enamel paint complete including taking out old UNSV cable support structure from the jetty gallery complete all as specified and as directed.
M&L for MS Plates (plain or chequered) channels, square cut or notched (ordinary and counter sunk) forming holes, without any attachmens complete all as specified and as directed including taking out of old unserviceable MS cable cover/support structure.Grade of steel Fe 410 -W (Gde E- 250) quality -A structure all as specified and directed.
M&L for fixing Galvasnized earth strip of size 32mm x 6 mm making drilled hole at both ends and fixing to cope point, PBs, and JBs including taking down old one unserviceable complete all as specified and directed.
M & L for XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade, cross-sectional area 400 sq. mm 3.5 core including taking out old unserviceable complete all as specified and directed.
All as per item No. 10.00 above, size 300 sqmm 3.5 core
All as per item No. 10.00 above, size 240 sqmm 3.5 core
stage.html
html • 0.07 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.32 MB
8361tender.pdf
Tender Documents • 1.12 MB
BOQ_827318.xls
BOQ • 0.38 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .