| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹13.4 LAccepted-AOC | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹16.6 L+₹1.9 L (12.5%)Rejected-Finance 54 KANWALI ROAD DEHRADUN 248001 | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-Finance Other than lowest bidder | |
| 3 | L3₹17.9 L+₹3.1 L (21.2%)Rejected-Finance 50 SARASWATI VIHAR SINGHAWALA AMBALA CITY | AMBALA CITY | L3 | Rejected-Finance Other than lowest bidder | |
| 4 | L4₹18.3 L+₹3.6 L (24.3%)Rejected-Finance | L4 | Rejected-Finance Other than lowest bidder | |
| 5 | L5₹18.7 L+₹3.9 L (26.7%)Rejected-Finance 195 MAHESH NAGAR AMBALA CANTT 133001 | AMBALA | HARYANA | 133001 | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹18 L
EMD Value
₹36,000
Closing Date
9 Oct 2021, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
GE UTILITY
GE UTILITY AMBALA CANTT 133001
REPAIR MAINT OF LT ELECTRIC DISTRIBUTIONS SYSTEM AT ORs JCOs MD ACCN AND UNIT LOCATED NEAR ALPHA POWER HOUSE UNDER GE U AMBALA CANTT
2021_MES_471087_2
CA NO GE U AMB 38 OF 2021 22
Open Tender
Civil Works
Item Rate
240 days
GE UTILITY AMBALA CANTT
As per Tender Documents
8 documents required · 8 mandatory
₹500
GE UTILITY AMBALA CANTT
₹36,000
Yes
2 Nov 2021
23 Sept 2021
11 Oct 2021
23 Sept 2021
9 Oct 2021
25 Sept 2021
23 Sept 2021 - 24 Sept 2021
60 days
Amount
Excavation in trenches n.exc 1.5 Mtr wide and n,exc 1.5 Mtr depth and not exec 10 Sqmm on plain in loose/soft soil and tabing out underground cable/erection of poles, stays etc complete all as specified and as directted by Engeer-in-Charge.
_do_ but exceeding 1.5 mtr deep and not exc 3.0 mtr deep.
M&L sand cushioning for cables with river washed sand and punning to provide required cover as per SSR part-1complete all as specified and as directed by Engineer-in-Charge.
Supply and laying bricks common burnt clay sub classs 'B' old size for cable protection complete all as directed.
Description all as per item Ser No 4 here in before but except bricks Note : Old bricks retrieved from item No 22 here in after shall be reused.
M&L PCC 1:4:8 type D2 using 40 mm graded crushed stone aggregate for mass filling in pole pit and foundation etc including provision of necessary from work to achieve fair finished surfaces complete all as specified and directed.
M&L PCC 1:3:6 type C2 using 40 mm graded crushed stone aggregate as in pole foundation, coping stay etc including provision of necessary form work to achieve fair finishes surfaces, complete all as specified and directed.
Returning, filling (Soil) including spreading, levelling, watering and well ramming in layers not exc 25CM thick layers complete all as specified and as directed by Engineer-in-Charge..
Removal of excavated material soil n,exc 50 Mtr away and depositing where directed at a level not exc 1.5 mtr above the starting point complete all as specified and directed by Engineer-in-Charge
Dismantling and taking down old unserviceable PCC pole any type after disconnecting all eletrical connection incl clearance of site complete all as the direction of Engr-in-Charge.
Supply erection of PCC pole 9.0 mtr long in true vertical position 102x172 mm at top 102x279 mm at bottom class-10 incl providing black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip complete all as specified and as directed by Engr-in-Charge. Note Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Dismantling and taking down old unserviceable steel pole any type after disconnecting all eletrical connection incl mabing good and clearance of site complete all as the direction of Engr-in-Charge.
Supply erection (in true vertical position) Steel tubular swaged poles complete with cast iron base plate, finial taper plug bolts, nuts & screws all as specified of type 410 SP-31 ( 9.0 mtr length) complete all as specified in IS 2713 (Part-II) 1980 including one coat of red oxide primer and two coats of aluminium paint to exposed surfaces incl providing of two coats of black and white strips with synthetic enamel paint 30 cm each alternate upto 1.5 mtr above the coping of pole starting with black strip and with black bituminus paint for embedded portion of pole compete all as specified and as directed by Engr-in-Charge. Note Earth work and PCC shall be measured and paid seperately (ii) Description as per direction of Engineer-in-Charge will be printed on each pole without any extra cost.
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4.0 x 10-50 Sqmm complete all as directed by Engr-in-Charge.
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-150 Sqmm complete all as directed by Engr-in-Charge.
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 185-300 Sqmm complete all as directed by Engr-in-Charge.
Supply and fixing indoor/outdoor end termination joint heat shrinkable 1100 Volts for XPLE cable of size 3.50 x 400 Sqmm complete all as directed by Engr-in-Charge.
Supply and fixing straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5/4 x 25-50 Sqmm complete all as directed by Engr-in-Charge. Note. Earth work will be measured and paid seperately.
Supply and fixing straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 70-150 Sqmm complete all as directed by Engr-in-Charge. Note. Earth work will be measured and paid seperately.
Supply and fixing straight through joint heat shrinkable 1100 Volts for XPLE cable of size 3.5 x 185-400 Sqmm complete all as directed by Engr-in-Charge. Note. Earth work will be measured and paid seperately.
M&L for drilling hole of any size manully as per site requirement, drilling for laying pipes under the road for crossing electrical cables complete all as per direction of Engr-in-Charge . Note : Pipe will be measured and paid for seperately.
Disconnecting & taking out defective underground cable any size and any type with bricks from trenches, pole, pipe, floor, wall etc. all as directed by Engineer-in-Charge.
Supply and laying, connecting and testing XPLE underground cable insulated, and overall sheathed with aluminium conductor heavy duty 1100 volts grade 16 sqmm 4.0 core laid in trenches/ on pole/road crossing or passing through existing/new pipe under road crossing clamping on wall etc, Note : (i) Earth work, sand , bricks removing , returning filling Aluminium thimbles/lugs will be paid seperately. (ii) Cost of laying electrical cable through new/existing pipe under road, buildings, railway tracks, highways are incl in the quoted rates (iii) All equiments, machinery or tool if required for laying electrical cable through new/existing pipes are provided by the contractor without any extra cost.
Description all as per item ser No 23 above but 25 Sqmm 3.5 core.
Description all as per item ser No 23 above but 35 Sqmm 3.5 core.
Description all as per item ser No 23 above but 50 Sqmm 3.5 core.
Description all as per item ser No 23 above but 70 Sqmm 3.5 core.
Description all as per item ser No 23 above but 95 Sqmm 3.5 core.
Description all as per item ser No 23 above but 120 Sqmm 3.5 core.
Description all as per item ser No 23 above but 150 Sqmm 3.5 core.
Description all as per item ser No 23 above but 185 Sqmm 3.5 core.
Description all as per item ser No 23 above but 240 Sqmm 3.5 core.
Description all as per item ser No 23 above but 300 Sqmm 3.5 core.
Description all as per item ser No 23 above but 400 Sqmm 3.5 core.
Supply and fixing stay assembly complete with all accessories, such as stay plate 230x230x6 mm, stay rod 215 cm long and 16 mm dia with nuts incl GI bow turn buckle, GI stay wire, Loop type insulator etc all as per electrical plate No 1 or SSR part 1 and as directed incl taking down old unsv stay. Note: Excavation and PCC work will be measured and paid seperately.
M & L in replacement cross arms,bracings, supports, clamps and back plates fabricated from structural steel section incl nuts, bolts, washers, welding, bending cold or hot, drilling holes for bolts, in any shape of size as indicated or directed and inclusive provision of two coats of synthetic enmel paint over a coat of red oxside primer and prepration of steel surfaces complete all as specified and directed.
M & L in replacement shackle type porcelain vitreous white or brown insulator including GI straps washers, insulator bolts and nuts for working pressure 1100 volts, 75 mm hight, 90 mm dia, section of strip 30mmx3mm & dia of bolt 12 mm complete all as specified and as directed by Engineer-in-Charge.
M & L in replacement pin type insulator porcelain vitreous white or brown 1100 volts grade 100 mm hight and 65 mm dia with GI spindle two washer and one GI nut complete all as specified and as directed by Engineer-in-Charge.
Dismantling and taking down old unserviceable ACSR conductor incl cutting, welding complete all as per direction of Engr-in-charge.
M&L aluminium conductor steel reinforced (ACSR) including fixing, stretching on poles and proper loosing with binding wire with insulator of any size as required at site complete all as specified by Engr-in-charge.
M&L in replacement 1100 volts grade heavy duty cable PVC insulated solid aluminium conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 meter apart including 4 mm GI suspension wire, one twin core cable flat or circular of size 10 sqmm 2 core complete all as directed by Engr-in-Charge.
Dismantling and taking down old u/s earthing and providing earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick burind directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of rarth electrode not less than 1.5 mtr below normal ground level and connected with GI earth strip of size 25x4 mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6), pit cover 50mm thick RCC 1:2:4 type B-1 using 8mm steel bars @ 10 cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20 mm bore medium grade , funnel, wire mesh, also including earth work, common salt, charcol dust complete all as specified and as directed by Engr-in-charge.
Dismantling and taking down old u/s earthing and providing earthing complete with galvanized steel earth electrode plate of size 60x60x6mm thick burind directly in ground/earth pit not less than 2.25 mtr deep below normal ground level and top edge of earth electrode not less than 1.5 mtr below normal ground level and connected with GI earth wire of size 4mm by means of nut, bolts, washers etc to eqpt/machinery all as shown in electric plate No 3 of SSR Pt I including PCC (1:3:6) pit, cover 50mm thick RCC 1:2:4 type B-1 using 8mm for steel bars @ 10 cm C/C both ways, 20 mm bore medium grade GI protection pipe, watering pipe 20 mm bore nedium grade , funnel, wire mesh, also including earth work, common salt, charcol dust complete all as specified and as directed by Engr-in-charge.
M&L in replacement GI tubing 50 mm bore light grade, on poles, on walls, under floors, road crossing as reqd at site complete all as directed by Engr-in-Charge. Note : Clamps, Nut bolts, saddle etc will be measured and paid seperately.
_do_ but 80 mm dia.
Supply and fixing in replacement MCCB TPN 250 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 200 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 160 Amps, 415 Volts, 25 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 100 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 63 Amps, 415 Volts, 16/18 KA,4 pole , Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 800 Amps, 4 pole with microposecessor release IPRE + ( 4 pole) 800 A, 50 KA, Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
Supply and fixing in replacement MCCB TPN 630 Amps, 4 pole with microposecessor release IPRE + ( 4 pole) 630 A, 50 KA, Ics=100% Icu, overload adjustable short circuit adjustable type incl complete connection all as per direction of Engr-in-Charge.
M&L detecting fault in cable of any type with fault locator equipment which is capable for supply toserviceable cable Note :- (a) The fault which is detected through cable fault locater will only be paid under this item (b) Charges of Cable fault locator and DG set including transportation charges deemed to be included in the quoted rate.(c) Earth fault locator will be provided by the contractor for even single fault no delay on this account will be acceptable otherwise penality will leived Rs 500/- per day. (d) Necessary testing of cable after making joint will be deemed to be included in the cost of relevent item.However necessary earth work cable cutting, joint making joint will be paid under relevant item.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 4 line as per IS complete as per direction of Engr-in-Charge.
Supply and fixing LT line separators 1100 V grade PVC spacer to separate LT conductor from each other 3 line as per IS complete as per direction of Engr-in-Charge.
Re-streteching existing/retrieved ACSR conductor on LT pole and building conductor on insulator properly using new binding wire/jumper wire complete all as directed at site by Engr-in-Charge. Note : (i) Each Run of line conductor shall be measured & paid for separetly.
Material and labour in replacement aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 50 sqmm incl dismantling old thimbles of any type all as directed.
Material and labour in replacement aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 70-185 sqmm incl dismantling old thimbles of any type.
Material and labour in replacement aluminium terminals (thimbles) in 1100 volt LT XLPE cable upto size 240-400 sqmm incl dismantling old thimbles of any type.
Material and labour for shifting heavy items / excavation / cleaning areas / cleaning site by providing crane/hydra/excavators/tractors/trolley etc. as required at site complete, all as specified and as directed.
Repair to LT panel size upto 0.6 x 0.6 x0.6 mtr and cleaning of surface including removing rested particles removing dust tightening nut, bolts welding and painting one coat with aluminium paint including stand complete all as directed. Note : (i) Cost of marking descriptio on the front door as per direction of Engr-in-Charge is incl in quoted rate (ii) Cost of misc items like copper cable, lugs thimbles etc if required are included in quoted rates.
Repair of LT panel size upto 1.2 x 1.2 x0.6 mtr and cleaning of surface including removing rested particles removing dust tightening nut, bolts welding and painting on complete panel with one coat of synthetic enamel aluminium paint including stand complete all as directed. Note : (i) Cost of marking description on the front door as per direction of Engr-in-Charge is incl in quoted rate (ii) Cost of misc items like copper cable, lugs thimbles etc if required are included in quoted rates.
Cleaning of steel tubular poles LT 9 mtrs long including removing rusted particles and panting with one coat of synthetic enamel aluminium paint including stand cross arms, bracing, supports,clamps eye hooks, security light bracket clamps etc providing black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paints incl reparing and painting on coping with cement base white paint complete all as directed. Note : (i) The quoted rate shall includes making of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates shall includ the reparing of coping with cement / PCC as directed.
Material & Labour one coat cement base paint on PCC pole 9 mtr including black & white strips alternatively 30cm each from coping upto 1.5 mtr height starting with black strip using synthetic enamel paint and painting with one coat of synthetic enamel aluminium paint on cross arms bracing supports, clamps, eye hooks, security light bracket, clamp etc incl reparing and painting on coping with cement base white paint complete all as directed. Note : (i) The quoted rate shall includes making of numbers on each LT pole as per direction of Engr-in-Charge. (ii) The quoted rates repair coping with cement/PCC deemed to be included.
M&L spraying chemical (Round up) on area to remove unwanted vegitation/grass at various locations as directed by Engr-in-Charge
Supply and fixing in repair on load change over switch with sheet steel Enclosure 415 V, 4 pole, 100 Amps capacity fixed on walls for electric supply distribution between main and DG set incl necessary connection of cable from LT panels to change over switches complete all as specified and directed by Engr-in-Charge.
Dismantling electrical incoming and out going AC/DC connections and inspection complete of ON line UPS 15 KVA, 3 phase AC input 300-450 volts, output voltage 415+/-1% with maintenance free battaries 30 Nos and finding out the fault of the UPS by means of megger, multimeter and other required eqpt which helps to check the fault rectify the fault including re-connecting AC/DC cables and other accessories & testing complete on full all as specified and as directed by Engr-in-Charge. Make of UPS : Microtec and make of batteries : Excide Note : (i) The rates of minor items for repair of UPS deemed to be included in quoted rate. (ii) service Engineer shall be from Microtec company for repair of UPS system (iii) The batteries required for replacement shall be measured and paid seperately under relavant items.
Supply and fixing in replacement maintenance free batteries of capacity 12V 17/18 AH and testing complete all as specified Make; Exide/Luminious/Amron/Amara Raja/Penasonic/Evereday.
M&L Chemical spray (DC>2.26 having container 415 ml/300g for precision blended multipurpose product for prevents corrosion penetrates, lubricants, displaces and seals out moisture release rusted mechanisum clearnes etc complete all as specified and directed by Engr-in-Charge.
Dismentling and Supply, Install, Test and Commissioning of LT feeder piller box outdoor type fabricated of size 0.6x0.6x0.5M,out of 3.00 mm thick CRCA sheet, CPRI approved complete with powder coating with seven tank process mounted on MS angle frame of size 40x40x5mm, duly grouted with PCC using concrete 1:2:4 type B-1 reqd with the following (a) S & F Copper bus bar 200 Amp with coloured heat shrinkable insulated sleeve 415 volts as per IS of suitable size mounted on DMC/epoxy insulator (not less than 50mmx50mm conicle type at a maximum interval of 500 mm - 01 Set. (b) S&F MCCB FP 63 Amps 16 KA - 01 No For Main incoming (i) The quoted rate shall includes minor items such as lugs, nuts & bolts, washers, top insulators, sleeves, provision of extra holes in bus bar etc. (ii) Panel drawing shall be got approved before placing of order from Engr-in-Charge. (iii) The bus bar connection for cable from main bus bar to outgoing MCCB will be connected through suitable rating bus bar strip type duly insulated. (iv) Cost of making description on the front door as per direction of Engr-in-Charge deemed to be included in quoted rate. (v) Cable will be entered in panles through gland.
Note :- Amount of credit of Rs. 137375.00 for retrieved materials is mentioned in Schedule of Credit mentioned in tender documents in pdf form which will be deducted offline while acceptance of tender.
Saurav Enterprises
R N Enterprises
sheetal engineering
Raman Electric Trading Co
sanjeev enterprises
Esha Engineers
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .