Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹37.5 CrAccepted-AOC | ₹37.5 Cr | L1 | Accepted-AOC Lowest bidder |
| 2 | L2₹38.7 CrRejected-Finance | ₹38.7 Cr | L2 | Rejected-Finance Other than lowest bidder |
| 3 | L3₹38.9 CrRejected-Finance 35 B BHERU VILLAS SARDAR CLUB SCHEME AIR FORCE JODHPUR 342 011 RAJASTHAN | JODHPUR | JODHPUR | RAJASTHAN | 342011 | ₹38.9 Cr | L3 | Rejected-Finance Other than lowest bidder |
| 4 | L4₹41.2 CrRejected-Finance | ₹41.2 Cr | L4 | Rejected-Finance Other than lowest bidder |
| 5 | L5₹41.4 CrRejected-Finance K 99 LGF KALKAJI NEW DELHI 110 019 | NEW DELHI | SOUTH EAST DELHI | DELHI | 110019 | ₹41.4 Cr | L5 | Rejected-Finance Other than lowest bidder |
Tender Value
₹33 Cr
EMD Value
₹15 L
Closing Date
27 Jul 2022, 6:00 pmClosed
CHIEF ENGINEER COAST GUARD VISAKHAPATNAM
Office of HQ CE CG Visakhapatnam-530007
PROVISION OF SECURITY WALL, CONCERTINA COIL AND MD ACCOMMODATION FOR EPS AND CIVILIAN AT KAKINADA
2022_MES_516220_2
CE (CG) /VIZ/KKN/TOKEN 01 OF 2022-23
Open Tender
Civil Works
760 days
KAKINADA
As per tender documents
9 documents required · 9 mandatory
₹3,000
AGE I CG Vizag
₹15 L
Yes
2 Sept 2022
8 Jun 2022
29 Jul 2022
8 Jun 2022
27 Jul 2022
30 Jun 2022
Amount
Schedule "A" Part – I to Schedule "A" Part – XIV: NOTE: Schedule "A" Part – I to Part – XIII are prepriced by MES. Bidders shall insert their Lumpsum amount in Green coloured field under Column - 6 only
Lump Sum price worked out by the contractor for "BUILDINGS & STRUCTURES", for the lumpsum price of Rs. 22,72,85,000.00 inserted by MES as listed in Schedule 'A' Part - I on Serial Page No. 35
Price worked out by the contractor for "EARTH WORK, SITE CLEARANCE AND AREA DEVELOPMENT ", against the price of Rs. 63,60,859.70 inserted by MES as listed in Schedule 'A' Part - II on Serial Page No. 36
Price worked out by the contractor for "PILE WORK ", against the price of Rs. 6,62,44,443.2 inserted by MES as listed in Schedule 'A' Part - III on Serial Page No. 37
Price worked out by the contractor for "INTERNAL WATER SUPPLY", against the price of Rs. 7,49,662.08 inserted by MES as listed in Schedule 'A' Part - IV on Serial Page No. 39
Price worked out by the contractor for "INTERNAL ELECTRIC SUPPLY", against the price of Rs. 16,67,519.42 inserted by MES as listed in Schedule 'A' Part - V on Serial Page No. 41
Price worked out by the contractor for "EXTERNAL WATER SUPPLY", against the price of Rs. 7,36,615.36 inserted by MES as listed in Schedule 'A' Part - VI on Serial Page No. 43
Price worked out by the contractor for "EXTERNAL ELECTRIC SUPPLY", against the price of Rs. 19,01,827.41 inserted by MES as listed in Schedule 'A' Part - VII on Serial Page No. 46
Price worked out by the contractor for "AREA DRAINAGE", against the price of Rs. 1,13,91,534.30 inserted by MES as listed in Schedule 'A' Part - VIII on Serial Page No. 48
Price worked out by the contractor for "SEWAGE DISPOSAL", against the price of Rs. 5,76,748.86 inserted by MES as listed in Schedule 'A' Part - IX on Serial Page No. 50
Price worked out by the contractor for "ROAD/PATH/HARDSTANDING/CULVERT WORK", against the price of Rs. 1,78,93,588.31 inserted by MES as listed in Schedule 'A' Part - X on Serial Page No. 53
Price worked out by the contractor for "SECURITY WALL", against the price of Rs. 2,22,86,758.36 inserted by MES as listed in Schedule 'A' Part - XI on Serial Page No. 56
Price worked out by the contractor for "LIGHTENING PROTECTION AND OBSTRUCTION LIGHT WORK", against the price of Rs. 2,91,629.90 inserted by MES as listed in Schedule 'A' Part - XII on Serial Page No. 57
Price worked out by the contractor for "FIRE FIGHTING AND FIRE ALARM SYSTEM", against the price of Rs. 6,83,198.00 inserted by MES as listed in Schedule 'A' Part - XIII on Serial Page No. 59
Schedule "A" Part - XIV [Miscellaneous Items]
INTERNAL ELECTRIFICATION
Item No 1 : M & L for concealed point wiring on wall/floor/ ceiling etc with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized modular sunken boxes factory made with earth dolly and grid and crown plate and cover plate for fixing of modular switches/sockets/fan regulators, etc with captive steel screw including PVC-FRLS insulated unsheathed copper multi-stranded conductor of size 1.5 Sqmm, 1100 volts grade for continuous earthing after cutting the chases and making good the surface all as specified and directed by Engineer-in-Charge for the following :-
(a) One light point/security light/ceiling/exhaust/wall mounted fan controlled by one switch
(b) One bell point controlled by one switch
(c) One 3 pin socket outlet , 5 Amps on an independent board controlled by one switch .
(d) One 3 pin socket outlet , 5 Amps on same board controlled by one switch .
(e) One light point controlled by two switches single pole two way
Item No 2 : M & L for concealed point wiring on wall/floor/ ceiling etc with necessary fixing arrangements with PVC-FRLS insulated and unsheathed copper multi-stranded conductor of size 4.0 Sqmm, 1100 volts grade drawn in and including rigid non metallic white / ivory PVC conduit medium grade ISI marked not less than 20 mm dia with all conduit accessories/ fittings such as junction boxes, bends, tee, elbow etc including anodized modular sunken boxes factory made with earth dolly and grid and crown plate and cover plate for fixing of modular switches/sockets/fan regulators, etc with captive steel screw including PVC-FRLS insulated unsheathed copper multi-stranded conductor of size 2.5 Sqmm, 1100 volts grade for continuous earthing after cutting the chases and making good the surface all as specified and directed by Engineer-in-Charge.
Item No 3 : M&L for 1 X 20 watt LED ceiling/wall mounted lighting fixture with Lamp Lumen not less than 2100 lumen polycarbonate body ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. MAKE :- Cat-Part No. BN021CLED20S-PSUCWGRS2 of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 4 : M&L for 1 X 8/10 watt LED ceiling/wall mounted lighting fixture with Lamp polycarbonate body ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. MAKE :-Cat-Part No. BN021CLED10S-6500-SUCWGRS1 of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 5 : M&L for 1 X 20 watt decorative ultra silm square profile liner LED lighting fixture with Lamp polycarbonate body ,enviornmental friendly ,energy efficient fixed to wall/ ceilling & connecting upto ceiling rose with three core twisted flexible 1.5 sqmm PVC copper conductor cable with earthing complete all as specified and as directed. MAKE :- Cat-Part No. SM251CLED20S-6500PSUWH of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 6 : S&F LED Security light fitting with driver of 1X40W, with HF electronic driver pre wired with 1.5 Sqmm copper conductor cable upto connector suitable for 40mm dia pole of GI tubing Med grade bend to shape fixing on wall with suitable MS brackets and clamps complete all as specified and as directed. MAKE :- Cat-Part No. BRP409LED40CWHOMRFGPSUGR of PHILIPS or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 7 : S& F LED bulb 9 Watt pin type system lumen not less than 770 Lumen complete all as specified and directed.
Item No 8 : S& F ceiling fans AC single phase 230 V of size 1200mm sweep with complete set with fixtures. BEE 5 star rating, metallic body including provision of three core flexible copper wire of size 23/0.0076 from ceiling rose/point wiring to ceiling fan complete all as specified and directed.
Item No 9 : S& F Bell Multi Music type AC 230 V complete all as specified and as directed.
Item No 10 : M&L for exhaust fan metallic body with louver, heavy duty 300mm sweep 900 RPM with 230 V including connecting up with three core twisted flexible copper conductor cable of suitable size complete.
Item No 11 : M&L for exhaust fan WITH PVC blade with PVC louver, heavy duty 300mm sweep 900 RPM with 230 V including connecting up with three core twisted flexible copper conductor cable of suitable size complete. MAKE: Havells Model No VENTILDX or equivalent as approved by AGE(I) as per makes given in the list of makes.
Item No 12 : MCB single pole neutral (SPN), 32 amps, 240 volts, 10 KA, 'B' curve with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 13 : MCB single pole (SP), 10 amps, 240 volts, 10 KA, 'B' curve with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 14 : MCB single pole (SP), 16 amps, 240 volts, 10 KA, 'B' curve with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 15 : MCB TPN , 40 amps, 415 volts, 10 KA breaking capacity, 'B' curve with all incoming / outgoing connections with proper size of copper lugs complete all as specified as directed. Note:(i) Cost of copper lugs shall be included in the unit rate.
Item No 17 : M&L for switch flame proof rotay type with termination box in LM6, 16 Amp single pole 250 V including connecting up with twin core twisted flexible copper conductor cable of suitable size complete all as directed.
Item No 18 : M&L for flame proof , weather proof threaded type junction box in LM6, aluminium alloy 2/3/4 way complete all as directed.
Item No 19 : M&L for weather proof hose conduit of dia 300mm, long type complete all as directed.
Item No 20 : M&L for exhaust fan , flame proof 380mm sweep with louvers 230/240 V, 1440 RPM including connecting up with twin core twisted flexible copper conductor cable of suitable size complete. MAKE :- CAT Part No FWL1315-60cdl of CG or equivalent from Shyam/Sudhir
Item No 21 : Supply and Fix LED tube light fitting 1x20W flameproof type made of aluminium alloy LM6, with driver, bipin holders, connector block, etc. complete with all accessories prewired and including connecting up with 1.5Sqmm FRLS copper coductor complete all as specifed and directed by Engr-in-Charge. MAKE :- Shyam Switchgear/Crompton/Sudhir
Item No 24 : S&F electronic energy meter tamper proof with optical port single phase with LCD display operated on rated voltage of 240V AC supply 50Hz with rated current upto 5-30 A dust and moisture proof with polycarbonate case and sealing provisions for terminal cover and optical port with digital type of display and tamper recording features with self billing capacity with protection level IP-51 conforming to IS-13779 of 1999,) IEC complete all as specified and directed.
Item No 25 : Supplying & fixing factory made meter box tamper proof, shock proof and rust proof of suitable size for single phase meter at Item No.24 (Make: L&T/ HPL/ SECURE/ C&S).
Item No 26 : S& F of Geyser 25 Ltrs capacity vertical type 25 KW 230 Volts 50 Hz , 5 star rated including fixing arrangement by providing holding tank, nut bolt and connecting up electric cable and water supply connection alongwith 02 Nos connecting pipes, connecting wires and plugtops, complete all as specified and directed.
Item No 27 : S& F of PVC connector 15mm with PTMT nuts of length 600mm complete all as specified and directed.
ROAD/ PATH/ CULVERT
Item No 30 : Road stud (Cat Eye) of size 100 x 100 mm made up of ABS to be fixed with epoxy resin adhesive after cleaning the surfaces complete all specified. Cat-Part No. GPL-01-01 Make: GREENS/GREENLI TE or equivalent as approved by AGE(I),
Item No 31 : M&L M&L sparkle road solar stud with body made of aluminium die cast matt finish with anti-twist ribs on the bottom anchor of size approx. 125 mm x 125 mm x 18 mm & solar battery of 12 V with automatic dusk to dawn solar complete all as specified. Cat Part No. GPL-03-01 Make: GREENLITE or equivalent as approved by AGE(I),
PILE FOUNDATION
Item No 32 : Boring for bored cast in situ piles 600mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 50 M using hydraulic rig method complete all as specified and directed. (for pile of building )
Item No 33 : Boring for bored cast in situ piles 450mm dia in any type of soil/clay/soft rock except hard rock/fractured rock and getting out and disposal of spoil to a distance not exceeding 50 M using hydraulic rig method complete all as specified and directed. (for building and security wall)
Item No 34 : Chipping out pile upto cut off level including initial load disposal upto a distance of 50M all as specified and directed. (for pile of building and security wall)
(a) Compression test
(b) Pull out test
(c) Lateral test
(a) Compression test
(b) Pull out test
(c) Lateral test
Item No 37 : Carrying out Pile Integrity Test on 600mm dia piles all as per IS and as directed. (for pile of building )
(a) Compression test
(b) Pull out test
(c) Lateral test
(a) Compression test
(b) Pull out test
(c) Lateral test
Item No 40 : Carrying out Pile Integrity Test on 450mm dia piles all as per IS and as directed. (for security wall)
Item No 41 : MS pile liner fabricated out of 6mm and 8mm thick plain MS plate conforming to FE-410 S by welding, welding the joints, lengthening wherever required, providing stiffners, lifting hooks including all T&P as required, shifting the same from one position to other as required,driving in true vertical alignment in position to the required level for piles complete all as directed by Engr-in-Charge. NOTE : MS pipe liner shall be casted as mentioned in the drawings. However for payment purpose, the depth/height of liner shall be measured up to the cutoff level only irrespective of the depth provided for retaining concrete/bentonite slurry. The unit rate /price quoted shall deemed to include for the same.
SECURITY WALL AND GATE
Item No 42 : Concertina coil streches along with three lines for RBT supporting wire to same material as concertina coil having standard specification along the entire length of wall. complete all as specified and directed.
SEWAGE DISPOSAL
Item No 43 : 150 mm dia double wall corrugated pipe (SN4) laid in trenches and jointed incl coupler with rubber rings complete all as directed. Make: ASTRAL
EXTERNAL ELECTRIFICATION AND OBSTRUCTION LIGHT
Item No 44 : Supplying & laying XLPE insulated screened PVC embedded, electric cable with stranded aluminium conductor, 1100 volts grade, 2 core, 4 sqmm cross-sectional area, in trenches/trusses/ on wall on floor or through pipe with MS Clamp complete all as specified and as directed.
Item No 45 : Supply and fix ,connecting and testing Solid state electronic type aviation obstruction light fitting 302 LED with cast aluminium poly carbonate red colour installed at top of the building with propoer Supports and Clamps /Brackets etc. complete all as directed and specified. Make- Bajaj/Philips/Shyam switch gear
Item No 46 : Supply, install, test & commissioning of transformer confirming to IS 1180 with latest amendments, 315 KVA Outdoor type step down 11 KV/433 Volt copper wound 3 Phase, 4 Wire, 50 Hz, oil immersed naturally cooled with circuit tap changing switch on HT to vary secondary voltage +/- 2.5% to + 7.5% with first fill of transformer oil up to maximum level confirming to IS 335 and all standard fittings including cable box, oil temperature indicator from 0 to 120 degree C winding temperature indicating alarm and trip mercury switch contacts housed in a marshalling box with control cable connections, accessories as per latest IS and as per manufacturers design making necessary incoming & outgoing connections with and including cable end boxes and arrangement as needed for provision at site complete all as specified and as directed by Engr-in-Charge. Make Kirloskar/ Voltamp/Crompton Greaves. The transformer shall be complete with following fittings and accessories:- (a) Oil conservator with filling hole and cap with drain plug. (b) Silica gel breather with oil seal and first filling of dehydrating agent. (c) Pressure release valve with automatic resetting arrangement after release of pressure- 01 set (d) Oil tempreture gauge (indicator) having range (0-120 degree Centigrade)with max reading pointer 100 mm dia with shut off valve between the conservator and main tank. (e) Adequate No of Thermometer pocket including one No for accommodating bulb type Thermometer. (f) Drain cum bottel filter valve.
(g) Top filter valve. (h) Prismatic oil level gauge. (j) Inspection cover (k) Cover lifting Lugs. (l) Jacking and lifting lugs (m) Bi directional plain rollers -04 Nos. (n) Rating and diagram plate. (o) Separate neutral bushing brought out for earthing on LV side. (p) First filling of transfotmer oil conforming to IS 335-1972 with latest ammendments. (q) One No Air insulated cable box on HV side suitable for XLPE cable (r ) Air insulated plain bus bar terminals for bus connection including jointing materials. (t) Earthing terminals -02 nos located on diagonally opposite transformer tank base. (u) Copper alloy termination studs for connecting cables at HV and LV sides. NOTE :- THE TRANSFORMER SHALL BE BEE 5(FIVE) STAR RATING.
Item No 47 : Supply, installation, testing and commissioning of 125 KVAR rated capacity automatic power factor controller Outdoor kiosk type (APFC) system of ready to use conforming to IS : 8623 and suitable for 415 V, 3 Phase, 50 Hz AC and housed in elegant, fabricated from minimum 3.15 mm thick CRCA sheet with anti-corrosive coating and finally powder coated in texture RAL 7032 and consisting of the following:- Make :- Aplab/Schneider/L&T. (a) Three phase & neutral, aluminiun bus bar having current carrying capacity 600 Amps of suitable size including bus bar epoxy insulators and heat shrinkable PVC sleeve to differentiate the threee phase. (b) A set of heavy duty capacitor 2 Nos of 25 KVAR, 1 No. 50 and 2 Nos. 12.5 KVAR, type MPP-H by using metalised polypropylene technology having total losses less than 0.5 W/KVAR, high overload and frequent switching capability conforming to IS: 2834, IEC 831 capacitors should provided with special sequential pressure sensitive disconnector. (c) TP MCCB 630 Amps 50 KA load adjustable 70% to 100% thermal setting conforming to IS: 13943 to ensure positive isolation with suitable terminations.
Item No 48 : Supply and erecting two poles structure with 02 Nos of Prestressed concrete pole, 11.0 metres long. 152mm x 152mm at top and 152mm x 260mm at bottom, class 9 type 11 M long conforming to IS complete with bolts, nut, & screw all as specified and directed. (a) Excavation in trenches not exceeding 1.5meter wide and 2.0 M deep for pole foundation and getting out in soft loose soil, returning filling in the excavated of the soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 meters. (b) M& L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) n foundation 900mm x 600 mm cross section and painting depth 1.5 metre for concrete in casing the pole upto GL all as directed. (c) M& L for providing PCC (1:3:6) type C2 ( using 40mm graded stone aggregate ) for plinth block /collar above GI 2000 mm high and 450 mm dia all as directed and specified. (d) M& L for painting of poles externally with one coat of black bituminous paint (upto planting depth ) and above plinth block concrete collar with two coat of cement base paints of shade as approved by AGE(I) including preparation of surface and painting of 30 cm wide bands 3 Nos. with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5 M above plinth block.
Item No 49 : M&L for cutting of PCC/Hard standing/WBM road not exceeding 30 cm in width not exceeding 60 cm in depth for passing of HT cable and making good of disturbed surface to match with the existing surfaces by using old and new material i.e bitumen/PCC (1:3:6) type C-1 complete all as specified and directed .
Item No 50 : Supply, laying, jointing and testing cable XLPE insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cable (heavy duty) with aluminium conductor, 11000 Volts grade suitable for earthed system, of size 95 Sqmm 3 Core complete all as specified and as directed .
Item No 51 : Supply & fixing HT cable route marker made up of RCC 50mm thick 25cm width and 30 cm in length embossed with "HT CABLE" complete all as specified and as directed .
Item No 52 : Supply & fixing LT cable route marker made up of PCC 50mm thick 25cm width and 30 cm in length embossed with "LT CABLE" complete all as specified and as directed .
Item No 53 : Supply and fix cable jointing kit for 11 KV grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for3 core XLPE armoured Al conductor cable of size 95 sq mm complete all as specified and as directed.
Item No 56 : M&L for supply, installation, connection, commissioning and testing of Vertical type MCCB DB Double door TPN 6 way Model No DB VTL 006 GD Make-L & T Incoming and outgoing cable with lugs all all as specified and directed by Engineer-in-Charge. (For Type-III block and Type-II)-C1, C2 & C3 Incoming:- (a) MCCB Cap 100 Amps, FP 415 Volts breaking capacity 25 KA Microprocessor based - 01 Nos. Out Going:- (a) MCB TPN Cap 32 Amps, FP 415 Volts breaking capacity 10 KA - 08 No
Item No 57 : M&L for supply, installation, connection, commissioning and testing of Vertical type MCB DB Double door TPN 6 way Model No DB VTL 006 GD Make-L & T Incoming and outgoing cable with lugs all all as specified and directed by Engineer-in-Charge. (wall mounted enclosure for Lift for each Block) G1,G2 & G3) Incoming:- (a) MCCB Cap 63 Amps, FP 415 Volts breaking capacity 25 KA - 01 Nos. Out Going:- (a) MCB TPN Cap 32 Amps, FP 415 Volts breaking capacity 10 KA - 04 No. ( Lift Attendant room) (b) MCB SP Cap 10 Amps, FP 230 Volts breaking capacity 10 KA - 06 No. ( For common area)
Item No 59 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 150 sqmm cross-sectional area, complete all as specified and as directed.
Item No 60 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 120 sqmm cross-sectional area, complete all as specified and as directed.
Item No 61 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 50 sqmm cross-sectional area, complete all as specified and as directed.
Item No 62 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 35 sqmm cross-sectional area, complete all as specified and as directed.
Item No 63 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 3.5 core, 25 sqmm cross-sectional area, complete all as specified and as directed. NOTE : This includes 90 RM cable for Fire fighting items.
Item No 64 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 16 sqmm cross-sectional area, complete all as specified and as directed.
Item No 65 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 4 core, 10 sqmm cross-sectional area, complete all as specified and as directed.
Item No 66 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 2 core, 10 sqmm cross-sectional area, complete all as specified and as directed.
Item No 67 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 2 core, 6 sqmm cross-sectional area, complete all as specified and as directed.
Item No 68 : Supply ,fixing, testing and connecting LED Security light fittings 65 Watts , IP-65 cast aluminium housing in grey hammer tone stove enamelled finish outside with electric connection of Electronic driver and LED panel with suitable size of copper cable with base plate and complete all as specified and as directed. Make - Philips Cat Part No. BRP062 LED 65CW SLA S1 PSU or equivalent in Havells/ Crompton Greaves
Item No 69 : Supply and fix Prestressed concrete poles of 9 meter long having 102mm x 172mm at top and l20mm x 279mm at bottom,class 10 at bottom, including foundation and coping. (a) Excavation in trenches not exceeding 1.5meter wide and 2.0 M deep for pole foundation and getting out in soft loose soil, returning filling in the excavated soil after fixing the pole in foundation ramming earth around in layer not exceeding 25 cm thick and disposal of surplus soil to a distance not exceeding 50 meters. (b) M& L for PCC (1:4:8) type D2 (using 40 mm graded stone aggregate ) and foundation 900mm x 600 mm cross section and painting depth of 1.5 metre for concrete pole from the GL all as directed. (c) M& L for providing PCC (1:3:6) type C2 ( using 40mm graded stone aggregate ) for plinth block /collar above GL 2000 mm high and 450 mm dia all as directed and specified. (d) M& L for painting of poles externally with two coats of cement base paint of shade as approved by AGE(I) including preparation of surface including painting of 30 cm wide bands 3 Nos. with synthetic enamel paint of appropriate colour in alternate layer upto the height of 1.5 M above plinth block.
Item No 70 : M&l for bracket made out of GI pipe 25mm dia medium grade,1.2 mtr long bent to shape with welded MS flat 25 x 4 mm for mounting of fitting & MS flat iron clamps made out of 25mmX 4mm thick FI nuts, bolts complete all as directed by Engr-in-charge.
Item No 71 : Supply and fixing cable loop box with PVC of size 280x170x130mm mm including 6 amps MCB fixed in pole including necessary clamps bolts/nuts complete all as specified and directed. Make : Sintex or equivalent as approved by AGE(I). Make :- Sintex/Hensel or equivalent from the list of makes as approved by AGE(I)
FIREFIGHTING
Item No 72 : Supply, connecting, testing and commissioning Fire fighting non perlocating delivery hose 63 mm dia 2X15 m long IS:636 marked complete with hose coupling with hose coupling intentanneous type gun metal 63 mm dia heavy duty duty pair of male and female coupling on either side of hose pipe complete with branch pipe short, gunmetal 63 mm male itentaneous inlet male threaded outlet fitted with 12.5 bore Gunmetal nozzle bearing IS902 complete all as specified and as directed.
Item No 73 : Supply ,connecting, testing and commissioning air release valve 25 mm dia main inlet made from Gunmetal and fixing on the Top of MS down comer of 100 mm dia complete alongwith adequate capacity of air vessel all as directed.
Item No 74 : Supplying & laying PVC insulated , PVC sheathed cable galvanized steel strip or wire armoured heavy duty electric control cable with stranded copper conductor, 1100 volts grade, 2 core, 4 sqmm cross-sectional area, complete all as specified and as directed.
Item No 75 : Supplying & laying XLPE insulated screened PVC embedded, galvanized steel strip or wire armoured heavy duty electric power cable with stranded aluminium conductor, 1100 volts grade, 2 core, 6 sqmm cross-sectional area, complete all as specified and as directed.
Item No 76 : Supply ,connecting, testing and commissioning Gun metal fire brigade inlet connection (suction collecting head) consisting of Four Nos 63mm dia instantaneous type male coupling with built in check valves and 100mm dia sluice valve (one no 100mm dia NRV), and 100mm dia flanged outlet complete with all accessories.
Item No 77 : Supply ,connecting, testing and commissioning Booster pumps for 440 V, 3 Phase, 50 Hz Confirming to IS- 12469 :1988 With CI Casing bronze impeller and stainless steel shaft mounted on heavy duty bearings suitable for 440 volts, 3 phase, 50 Hz 30m head, 900 LPM discharge and HP not less than 6 HP, pressure of 3.5kg/sqcm at terrace level of the building including the starter panel.
Item No 78 : Supply, install and commissioning analogue addressable type Fire alarm control panel along with network interface card and with Lead acid battery back up for 08 hours normal operation and 15 minutes alarm operation. (The control panel, battery charger, etc shall be UL listed) Complying with BS EN 54 Single loop panel with 99 detectors & 99 modules & upto 200 detectors and modules (per each loop) complete all as specified.
Item No 79 : Supply and fix 4 kg ABC type dry chemical powder type fire extinguishers including all fixing accessories completed all as specified and as directed.
Item No 80 : Supply and fix 9 litres capacity fire extinguisher, ISI marked, confirming to IS:10204, containing 540 ml AFF liquid confirming to IS:4989 Part II and a polyurethane coated CO2 gas catridge, confirming to IS:4947 complete with gunmetal union cap, nylon hose with plastic foam making branch and wall mounting bracket completed all as specified and as directed.
Item No 81 : Supply and install Fire Extinguisher CO2 Type light weight squeeze grip type confirming to IS 15683 of capacity 5kg all as specified. Make: Ceasefire/Secure Zone/Safex
Item No 82 : S & F Fire Alarm sounder / sirens electronic type horizontal two stage continous normal operation for atleast 50 minutes with sound level 65 db to 120 db Measured at 1.5m with sound output Variation of +5 db 500m range.
Item No 83 : Supply and fix addressable single action manual call point having an integrally mounted addressable module that monitors and reports contact status complete all as specified.
Item No 84 : Supply and fixing Signage made of aluminium for Hydrants of Appropriate Size complete as directed by Engr-in-Charge.
Item No 85 : Supply and fixing Signage of Call Box of Appropriate Size complete as directed by Engr-in-Charge.
Item No 86 : Supply and fixing Signage of Hose Reel of Appropriate Size complete as directed by Engr-in-Charge.
Item No 87 : Supply and fixing Signage of Fire Point of Appropriate Size complete as directed by Engr-in-Charge.
Item No 88 : Supply and fixing Signage of Exit of Appropriate Size complete as directed by Engr-in-Charge.
DG SET
Item No 89 : Supply, installation, testing and commissioning of silent, Diesel engine driven factory assembled, floor mounted generating setongwith retrofit emission console device as per CPCB norms, of capacity 62.5 KVA/50 KW at 0.8 power factor or nearest higher size, 3 phase, 4 wire, 50 Hz, 1500 RPM as per IS 10001/10002 to take 10% over load complete with safety control and metering equipments mounted on & including common base frame with acoustic enclosure (canopy), weather proof as per CPCB norms, powder coated all as per manufacturer's instructions manual and all as specified and comprising of the items/ accessories listed hereinafter:- (A) Prime Mover : Directly coupled diesel engine, water cooled suitably de-rated of matching BHP for driving 62.5 KVA capacity, alternator electric start, four stroke confirming to latest IS-10001/10002 for continuous running and capable for taking 10% over load for 01 hour complete with following accessories:- (i) Fly wheel to suit flexible coupling. (ii) Flexible coupling with guards. (iii) Air cleaner with filters. (iv) Lubricating oil filter (v) Heavy duty radiator assembly with fan. (vi) Anti-vibration pad as recommended by manufacturers. (vii) PT pump with electronic gevernor of suitable capacity. (viii) Self starter 24 volts DC. (ix) Necessary arrangement for charging battery. (x) Maintenance free battery 12 volts , duly charged -02 Nos, capacity as supplied by manufacturer and as recommended by manufacturer alongwith flexible copper battery lead and connector. Make :- EXIDE/ AMCO/STANDARD as approved by GE.
(x) Maintenance free battery 12 volts , duly charged -01 Nos, 150 AH capacity as supplied by manufacturer and as recommended by manufacturer alongwith flexible copper battery lead and connector. Make :- EXIDE/ AMCO/STANDARD as approved by GE. (xi) Battery rack made out of MS angle iron 40 mm x 40 mm x 5 mm & 150 mm beight - 01 No. (xii) Standard safety device. (xiii) Daily services fuel tank for full running capacity of DG set for min 12 hours enclosed within the canopy all as per CPCB with lever indicator inlet, fuel outlet drain plug, air vent and locking arrangements etc including fuel pipe connections with connected GI pipe medium grade from fuel tank to DG set and over flow from the DG set to fuel tank complete with gate valve. (xiv) Exhaust system shall be provided with thermal insulation by using fire retardant/ non igniting foam conforming to BS-4735 to prevent excess heat radiation on the engine and safe for operator. (xv) Mechanical panel having following accessories :- (aa) Digital Lubrication oil temperature guage - 01 No. (ab) Digital Lubrication oil pressure guage - 01 No. (ac) Digital Water temperature guage - 01 No. (ad) Starting switch with key - 01 No. (ae) Battery voltmeter. (af) Indicator lamp etc. (ag) Digital Ammetar DC-01 No. (ah) Digital RPM meter-01 No. (aj) Safety measures : (i) Low lubricant oil pressure trip. (ii) High coolant temp trip. (iii) Engine over speed trip. (iv) Battery charging alternator. (v) Emergency stop pressed.
(B) Alternator : 62.5 KVA at 0.8 power factor, self regulated 3 phase with neutral 415 volts 50 Hz 1500 RPM as per IS : 13364 complete with automatic voltage regulator and foot mounted including making cable connection. The salient feature of alternator are as under :- (i) Voltage regulation under static condition + 1.5%. (ii) Class 'F' insulation. (iii) Permanently lubricating bearing. (iv) Capable to take 10% over load for one hour for every 12 hours. (C) Control AMF Panel : AMF control panel inside the floor mounted acoustic enclosure. Suitable for 62.5 KVA DG set with by pass assessment including all necessary operating and control device (to meet the requirement of above capacity plus 25% over load) such as contactors, MCCBs, CT's, volts meter, Ammeter, indicating lamp, frequency meter, energy meter with protection fuses for panel instrument battery charging ststem with indicator and cut off relays low and high oil pressure, high speed over load and earth fault protection, reverse current protection duly wired copper conductor cable and cable connection with lugs/thimbles complete as recommended by manufacturers and as directed.
(D) Repair tools and 2 years maintenance spare parts as per following:- Repair Tools :- (i) Ring spanner set of 10-01 set. (ii) Screw driver 6”, 8”, 12”, 14” & 24”-02 each (iii) Spanner set of 01-01 set. (iv) Adjustable spanner 12” – 04 Nos. (v) Cutting pliers – 01 No. (vi) Techo meter- 01 No. (vii) Tools kit box (only box) – 01 N (viii) 2 Years Spare :- (a) Fan belt set complete - 01 No (b) Lub oil filter - 01 Set (c) Fuel filter - 01 Set (d) Service manual and spare part catalogue with guarantee card (e ) Shock treatment chart dully framed - 01 Set (f) First Aid Box - 01 set (g) Fire extinguisher foam - 01 set (h) Fire extinguisher (electricity ) - 01 set Make - Engine and Alternator :- Refer Appx 'A' to PS.
(E) OEM MADE ACCOUSTIC ENCLOSURE :- Acoustic enclosure (canopy) suitable for 62.5 KVA DG with the following provisions/ specifications :- (i) The enclosure fabricated out of CRCA sheet of 14 SWG suitable to accommodate the DG Set properly. (ii) The sheet metal components are hot dip seven tank pretreated. (iii) It is pure polyester based powder coated (inside as wall as outside). All nuts/bolts/hardwares are zinc coated with salt spray test as per ASTMB- 117. (iv) Battery is accommodated in a tray in the enclosure. (v) The doors are fitted with gasket with high quality EPON gasket to avoid leakage of sound. (vi) Sound proofing of enclosure is done with high quality rock wool/mineral wool conforming to IS 8131 of 50 mm thickness and density of 96 kg/cum. (vii) The wool is further covered with fiber glass cloth and perforated powder coated sheet, insulation level conforming to UL 94 HF1 class flammability. (viii) A special residential silencer is provided within the enclosure to control exhaust noise. (ix) Specially designed alternators are provided to control sound at air entry to the container and exhaust from the container. (x) Adequate ventilation is provided to meet requirement for combustion and heat removal. If required a blower is used to meet total air requirement and air changes. (xi) Temperature of enclosure does not exceed beyond 50 degree C of ambient temperature. (xii) The enclosure is provided with “high enclosure temperature” safety device. (xiii) There should be provision of emergency shutdown from out side the enclosure. (xiv) There should be arrangement for proper illumination inside the canopy. (xv) Noise level should be 75 DB (A) at 1 mtr distance. (xvi) The accoustic enclosure should be as Approved by CPCB.
Item No 90 : Supply, installation testing and commissioning machine room less lift electrically operated with microprocessor based controls, complete with power driven automatic stainless steel (SS) sliding car doors and landing doors having stainless steel (SS) car enclosure suitble to carry 13 passengers (844 Kgs) at a speed of 1.5 M/Sec to serve upto 6 floors (G+5) with all standard features mentioned below and addition for Automatic rescue device complete all as per followings specifications:-
(A) TECHNICAL SPECIFICATION (a) Type & capacity : passenger elevator for 13 persons (844 Kg) (b) Type of drive : variable voltage and variable frequency drive with microprocessor based controller ± 5 mm landing accuracy with speed encoder. (c) Speed : 1.5 meter per second (d) Travel : Suitable for passenger travel of 18.5 meter. Ground floor, 1st floor, 2nd floor, up to 5th floor (Six floors, Six stops, Six level and for opening on same side.) (e) Required well size : 2500mm x 1900mm deep (Approx) without any projected beam/coloumn. (f) Power supply : 415/440 volts, three phase 50Hz AC. (g) Inner size : 2000mm x 1100mm deep (Approx) (k) Car enclosure : stainless steel panel, SS false ceiling (hairline finish) and mirror finish Handrail. (l) Flooring : Polished granite flooring. (k) Electric light : LED light fitting. (l) Fan : Pressure fan 400 mm sweep – 01 No. (m) Car entrance : Automatic, centre opening, sliding doors (n) Clear opening : 900mm x 2000mm high with provision of toughen glass of 600x300 central portion of both doors. (o) Operation door : Automatic operation (p) Control : Simplex full collective with and without attendant. (q) Indicators : Hall position indicators for car & landing. Direction and position indicator with stainless steel fixtures at all floors.
(B) STANDARD FEATURES (i) Anti nuisance car call protection (ii) Automatic car return device (home landing) (iii) Independent service (for duplex only) (iv) Overloading Device. (v) Nudging (vi) Emergency fireman’s service (vii) Audible Car Call button (viii) Emergency Car light unit (ix) High performance contact free infrared curtain door protection (x) Door time protection (xi) Emergency alarm Buttom (xii) Extra door time of lobby & parking (xiii) Door open close button xiv) Manual rescue operation (xv) Belt inspection device.
(C) ADDITIONAL FEATURES (a) Automatic rescue device (D) HUMAN INTERFACE DEVICE (HID) (i) Hall button with micro stroke push buttons combined with 16 – segment digital LED display position indicator. (ii) Full height car operating panel with micro stroke call push buttons (located on side panel) (iii) Door open/ door closed on car operating panel. (iv) 2-way intercommunication system (v) Dot matrix position indicator (vi) Battery operated Alarm bell & emergency light. (vii) Fireman’s switch at main lobby (viii) Manual rescue operation (ix) Call register indicator in all landings (x) Attendent operation system in car panel
EXTERNAL WATER SUPPLY
Item No 91 : Supply and fix Centrifugal pump set capable of pumping 500 ltre per min at a 35 metres head and not less than 8 HP, conforming to IS- 12469 :1988, coupled directly through a set of flexible coupling mounted on fabricated MS base plate, driven by and including electric motor squirrel cage induction suitable for operation on 415 V 3 phase, 50 Hz AC synchronous speed not more than 1500 RPM including copper conductor cable with flexible pipe protection from the panel mounted starter at common supply to pump motor alongwith pressure guage on discharge side, of capacity 10 HP complete all as specified and directed by Engr-in-Charge . Make Havells/ Kirloskar/Crompton Greaves
Item No 92 : Construction of Valve Chamber of size 900 X 900 X 1200 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 5 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as directed.
Item No 93 : Construction of Valve Chamber of size 450 X 450 X 600 mm internal size suitable for Sluice Valve, with PCC 1:4:8, Type D2, using 40mm graded aggregate for foundation, 200 mm thick Brickwork with old size Fly Ash Bricks in Cement Mortar 1:6, 40 mm thick PCC, 1:2:4, Type B1, using 20mm graded aggregate Coping, rendering in CM 1:4, 15 mm thick including provision of Mild Steel Sheet Cover 5 mm thick with 40 X 40 X 6 mm size Angle Iron frame work embedded in concrete with suitable hinges and locking arrangements including two coat of synthetic enamel black paint over a coat of red oxide zinc chrome primer to steel surfaces and including necessary earth work excavation in any type of soil etc., removal of surplus soil off the premises complete all as directed.
Item No 94 : S & F Gun-metal gate valves for 100 mm bore dia of pipe, with iron wheel head, screwed both ends for iron pipe and fixed ISI marked complete all as specified and directed.
Item No 95 : S & F Cast Iron foot valves for 100 mm bore dia of pipe, with iron wheel head ISI marked complete all as specified and directed.
EARTHINGS
Item No 96 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 4 mm GI Wire [Earth Lead] and GI pipe 15 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 97 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 25x4mm GI earth Strip [Earth Lead] and GI pipe 32 mm bore, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
Item No 98 : Earthing complete with Galvanised steel earth plate electrode 600 X 600 X 6 mm thick burried directly in ground [earth pit not less than 2.25 m deep below ground level] with top edge of plate not less than 1.50 m below normal ground level connected to 32 X 6mm GI Strip [Earth Lead] and GI pipe 50 mm, Medium Grade for earthing lead protection to the extent of maximum 7.5m, Earth Plate Electrode surrounded by 150mm thick packed layers of Charcoal and Common Salt filled in alternate layers, connected to the plate by means of GI Bolts & Nuts complete all as per Electrical plate No. 3 of SSR Part – I, connected to panel / DB including testing on completion including main earthing, Charcoal, Common Salt, PCC [1:2:4, Type B1] Pit with RCC 1:2:4, Type B1 Cover, 50 mm thick with 6 Nos, 8 mm dia TMT bars in both ways, MS frame made with 40 X 40 X 6 mm Angle Iron, MS Funnel with 20 mm bore, medium grade GI Watering pipe, wire mesh, earth work excavation, return filling, removal of surplus soil etc. complete all as specified and directed.
EARTH WORK
Item No 99 : Supply only Moorum/red bajri, good earth (from outside MoD land) and bringing to the site filling in floors or pavings, laid in layers n exc. 15 cm thick, spread, levelled and rammed including watering. complete all as specified. Note: A deduction of 10% shall be made from total computed volume of filling to cater in bulk irrespective of machinery used for ramming.
MANGLA AMIT BUILDERS PVT LTD
RAGHUSONS INFRA ENGINEERING PVT. LTD
Indus Projects Private Limited
SOOD ASSOCIATES PVT LTD
Komal Buildcon Pvt. Ltd.
CH.VEERARAGHAVULU CONSTRUCTION PVT LTD
SRICO PROJECTS PVT LTD
stage.html
html • 0.06 MB
tech_bid_open.pdf
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid