Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.8 LAccepted-AOC VILL PO PIRUMADARA TEH RAMNAGAR DISTT NAINITAL UK | RAMNAGAR | NAINITAL | UTTARAKHAND | L1 | Accepted-AOC 1ST LOWEST | |
| 2 | L2₹11.8 L+₹1.6 L (15.1%)Rejected-Finance C 23 CC | L2 | Rejected-Finance 2nd Lowest | |
| 3 | L3₹14.4 L+₹4.1 L (40.4%)Rejected-Finance | L3 | Rejected-Finance 3rd Lowest | |
| 4 | L4₹15.3 L+₹5.0 L (49.0%)Rejected-Finance | L4 | Rejected-Finance 4th Lowest | |
| 5 | L5₹15.5 L+₹5.2 L (51.0%)Rejected-Finance 110B CIVIL LINES BAREILLY 243001 UP | BAREILLY | UTTAR PRADESH | 243001 | L5 | Rejected-Finance 5th Lowest |
Tender Value
Refer Docs
EMD Value
₹30,000
Closing Date
15 Dec 2020, 6:00 pmClosed
GE EAST BAREILL
Garrison Engineer East Military Engineer Services Shahjahanpur Road Bareilly Cantt
REPAIR MAINT OF LT DISTRIBUTION SYSTEM AND LT CABLE AND MISC WORK AT RTS AND DEPOT HEMPUR UNDER GE EAST BAREILLY
2020_MES_395416_1
C/8884/E8
Open Tender
Electrical and Maintenance Works
Item Rate
180 days
HEMPUR
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
Yes
GE EAST BAREILLY
₹30,000
Yes
12 Jan 2021
14 Nov 2020
17 Dec 2020
14 Nov 2020
15 Dec 2020
3 Dec 2020
14 Nov 2020 - 26 Nov 2020
Amount
Dismantling cross arms of MS channel or angle section, MS clamps etc compelte all as specified and directed by the Engineer-in-Charge.
Dismantling insulators of any type, any size carefully and keeping at site for re-use etc complete all as specified and directed by the Engineer-in-Charge.
Dismantling stay assembly including demolition PCC and earth work compelte all as specified and directed by the Engineer-in-Charge..
Dismantling of ACSR conductors of any type and size complete all as specified and directed by the Engineer-in-Charge..
Dismantling earth wire of any type and size complete all as specified and directed by the Engineer-in-Charge..
Supply and fix pin type porcelaine, vitreous,brown insulator including one galvanised mild steel spindle,two galvanised iron washers and galvanised iron nut, 50 mm height,65 mmdia for 550 Volts grade completed and directed by the Engineer-in-Charge..
Supply and fixing shackle type insulator, porcelain, white brown, or green insulator of size 100x115mm (Height 100 mm and 115 mm dia) with section strip 31/5 mm and 14 mm bolt complete all as specified and directed by the Engineer-in-Charge..
Supply and fixing pin type composite insulation/silicon rubber material including one galvanishing MS spingle, nuts & washers of 150mm height, 150 mm dia for 11000 volt grade and fixing to the pole/structure and binding of conductor including taking down complete all as specified and directed by Engineer-in-Charge..
Supply and fixing disc type composite long rod insulator HT 11 KV out door type with composite insulating/silicon rubber materials type along with necessary acessories for connection of cables/ACSR conductors including taking down and making of cycle point complete, all as specified and directed by Engineer-in-Charge.
M&L for servicing and greasing GOD (gang operated air break switch) 200 Amps triple pole 11 KV including replacement of the following U/S parts :- (a) ACSR Jumper with RYB, PVC sleaves 1.5 m to 2.0 m long – 03 Nos (b) Brass connector brackets with bolts, nuts etc - 3 sets (c) Copper lugs of suitable size
M & L for taking down HT 11 KV grade tripple pole gange operated Air break switch from 4 pole/2 pole structure and S & F New gang operated Air break switch (GOD) HT 11 KV of 200 AMS capacity out door type suitable for vertical mounting fixed type complete with 3 no. silicon rubber polymeric insulator per phase all as specified and directed by the Engineer-in-Charge.
S&F stay assembly set comprising of stay bow, galvanised 16mm dia 400mm long stay rod 16 mm dia GI stay bow, 1800 mm long with nuts, bolts, washers, MS stay plate, 02 Nos thimble and clamp etc required with all accessories as specified Note :- Loop type insulators, excavation, earth work, concrete for foundation shall be measured and paid separately under respective item of Sch 'A'. PCC shall be measured and paid separately) compelte all as specified and directed by the Engineer-in-Charge..
S&F loop type insulator large size with over all dimension 90x140 mm clearance of hole 25.5 compelte all as specified and directed
S & F galvanised steel standard stay wire of size 3.15mm ( 70 Kg/Sqmm) grade for stay of poles including necesssary clamps of 50x6mm of flat iron complete all as specified in electtri 300x300x6 mm MS stay plate including thimbles, GI stay wire 7/3.15 mm SWG of required with all accessories as specified and directe by the Engineer-in-Charge.
M&L aluminium conductor steel reinforcd (ACSR) of any size for LT over head conductor on poles including stringing, tightening binding to insulators with aluminium wire making and connecting commissioning and testing compelte all as specified and directed by the Engineer-in-Charge..
M&L for 7 SWG GI continuous earth wire of size 3.15 mm or 4.00 dia for cradles, gurading and earth continuity on LT OH pole including suitable, binding wires etc complete all as specified and directed by the Engineer-in-Charge..
Supply and fixing pre-fabricated MS structural steel (IS marked) work consisting of channels / angles / other sections etc of various sizes and shape, cut / weld / drilled holes etc hot / cold in position for cross arms with FI clamps (full, half D and earth clamp etc) incl necessary MS bolts, nuts etc and painting, all as specified and directed by the Engineer-in-Charge.
M&L for opening the binding wire from pin/shackle insulator on steel pole of any height for re-stretching the ACSR conductor, after re-stretching without kinks & bends, binding the pin/shackle insulator with appropriate size of aluminium binding wire, etc complete all as specified and directed by Engr-in-Charge. NOTE :- (i) The above work includes clearing/ Trimning of tree branches falling around the conductors. (ii) Cost of binding wire deemed to be included in the quoted rate, No extra amount will be paid.
M&L for preparation of old painted steel surfaces of LT/HT steel tubular/swaged/rail poles of 9m to 11m long including brackets, clamps, channels and cross arms by cleaning of oils, lubricants, grease etc. complete above PCC coping and applying two coats of aluminium paint on surfaces 1m above PCC coping, applying two coats of synthetic enamel paint in zebra pattern with Aluminium and red colour combination up to 1m height above PCC coping; writing MES No. of poles (Number size shall be 25mm and lettering shall be 40mm) complete including applying two coats of white wash on exposed concrete surfaces of coping to poles duly preparing the surfaces all as directed by Engineer-in-Charge.
Trimming of tree branches along the LT overhead line up to 1.5 mtr from OH line to tree around the parameter, unit area complete all as specified and directed. Note:-Span shall be considered the distance between pole to pole.
S&F in replacement MCCB 4 pole 125 Amps, 25 KA 415V 50 HZ.
S&F in replacement MCCB 4 pole 200 Amps, 25 KA 415V 50 HZ.
S&F in replacement MCCB 4 pole 250 Amps, 25 KA 415V 50 HZ.
M&L for steel tubular poles complete with cast iron base plate, final taper plug, bolt, nuts and screws as specified type 410 SP-31(9 mtr long). Including painting pole with two coats of bituminous paint internally and external embedded portion in ground concrete and painting exposed surface with two coats of aluminum paint over one coats of aluminum paint over one coat of red oxide primer including taking down of existing LT pole of any size and re-fixing of chaneel, insulator and electric connection etc, complete all as specified and directed by the Engineer-in-Charge.
Supply and laying XLPE insulated armoured heavy duty electric cable with aluminium conductor 1100 volts grade ISI marked as per IS 7098-I laid in trenches ducts or fixing or passing through GI pipe across the road/path/drains/along wall/floor/ pole/ equipment etc. cross sectional area including cable lugs of following size including taking down of existing cable complete all as specified and directed.by Engr-in-Charge for LT cable 2 Core 16 Sqmm
Ditto all asper item no 25 above but LT cable 4 core 16 Sqmm
Ditto all asper item no 25 above but LT cable 4 core 25 Sqmm
Ditto all asper item no 25 above but LT cable 3.5 core 35 Sqmm
Ditto all asper item no 25 above but LT cable 3.5 core 50 Sqmm
Ditto all asper item no 25 above but LT cable 3.5 core 70 Sqmm
Ditto all asper item no 25 above but LT cable 3.5 core 120 Sqmm
Ditto all asper item no 25 above but LT cable 3.5 core 300 Sqmm
Excavation in trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed by the Engineer-in-Charge.
Excavation in trenches not exceeding 1.5 mtr wide and exceeding 1.5 mtr in depth for foundation, laying of pipe etc and not exceeding 10 sqm on plan for manhole etc and getting out in soft/loose soil, complete all as specified and directed by the Engineer-in-Charge..
Returning, filling in, including spreading levelling, watering and well ramming in layers not exceeding 25 cm in soft / loose soil complete all as specified and as directed by the Engineer-in-Charge.
Removing excavated material (soils) to a distance not exceeding 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed by the Engineer-in-Charge.
Supply and laying dry burnt bricks, sub class ‘B’ old size in cable trenches, as cable protection complete all as specified and directed by Engr-in-Charge.
M&L Dry sand cushioning to under ground electric cable on layer of 08 cm thick before laying the cable and second layer of 15 cm thick after laying the cable all as specified in clause 19.75 of M.E.S Schedule Part-I complete all as specified and directed.by Engr-in-Charge
Cutting/Boring of road/Hard standing to a size of 30 cm in width and not exceeding 60 cm in depth for laying of protection pipe/water line/Cable including returning filling, Including spreading and providing PCC in (1:2:4) Type B1 (using 20 mm grade stone aggregate) for the top 100mm layer, complete all as specified and directed.by Engr-in-Charge
Supply and laying galvanised iron pipe 50mm bore light grade fixed to poles with steel clamps laid under road crossing, fixed to wall etc complete all as specified and directed by Engr-in-charge.
Material and labour for P.C.C (1:3:6) type C-2 (using 40 mm graded crushed stone aggregate) as in foundation of pole and filling of mass concrete including providing necessary form work complete all as specified and as directed by the Engineer-in-Charge.
M&L for PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in coping to poles including necessary form work and applying three coats of white wash over the surfaces of coping including demolition of existing disturbed coping and removing the debris to a distance n.exc. 50m complete all as specified and as directed by the Engineer-in-Charge.
RAMAN CONSTRUCTION CO.
raman enterprises
sunder and company
M/S Rajeev Sharma and Co.
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .