Loading…
Tenderkart now works inside Claude and ChatGPT: search and analyse tenders right from your chat
Loading…
Tender ID
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.0 LAccepted-Finance HALISAHAR NATUNPARA NORTH 24 PARGANAS | HALISAHAR | NORTH 24 PARGANAS | WEST BENGAL | 743135 | L1 | Accepted-Finance Being L1 Bidder. | |
| 2 | L2₹7.5 L+₹56,300 (8.10%)Rejected-Finance 174 G 1 NETAJI COLONY BARANAGAR KOL 700090 | BARANAGAR | KOLKATA | WEST BENGAL | 700090 | L2 | Rejected-Finance Being L2 Bidder. | |
| 3 | L3₹7.5 L+₹57,380 (8.25%)Rejected-Finance 133 GARFA MAIN ROAD KASBA KOLKATA 700078 | KOLKATA | KOLKATA | WEST BENGAL | 700078 | L3 | Rejected-Finance Being L3 Bidder. | |
| 4 | L4₹8.3 L+₹1.4 L (20.0%)Rejected-Finance 1260 GANGAPUR GROUND FLOOR MANDIRTALA DUTTAPUKUR NORTH 24 PARGANAS WEST BENGAL 743248 | 24 PARAGANAS NORTH | WEST BENGAL | 743248 | L4 | Rejected-Finance Being L4 Bidder. |
Tender Value
Refer Docs
EMD Value
₹13,904
Closing Date
1 Oct 2024, 12:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
EE, North 24 Parganas Electrical Div.P.W.Dte.
OFFICE OF THE EXECUTIVE ENGINEER NORTH 24 PARGANAS ELECTRICAL DIVISION, TOP FLOOR, MECHANICAL COMPLEX,BAGUIATI, KOLKATA 700 059
Urgent Electrical illumination works at entire Hospital campus at Naihati State General Hospital, Dist. - North 24 Parganas under Barrackpore Electrical Sub-Division, P.W.Dte. (Rattirer Sathi Scheme)
2024_WBPWD_754107_1
WBPWD/EE/N24/EL/e-NIQ178/24-25
Open Tender
MISC ELECTRICAL WORKS
Item Rate
10 days
Naihati State General Hospital
Please refer Tender documents.
4 documents required · 4 mandatory
₹13,904
3 Oct 2024
19 Sept 2024
3 Oct 2024
19 Sept 2024
1 Oct 2024
19 Sept 2024
Amount
Supply & Delivery of 100 Watt outdoor type LED Street light fittings with IP-66, individual Secondary Optics Peanut Lens and Separate Toughned Glass Diffuser, Potted Driver with 10KV SPD and minimum efficiency > 110 LPW as directed by EIC. (Crompton/Philips/Wipro).
Supply & Delivery of 100 Watt LED flood light fittings with IP-66, individual Secondary Optics Peanut Lens and Separate Toughned Glass Diffuser, Potted Driver with 10KV SPD and minimum efficiency > 110 LPW as directed by EIC. (Crompton/Philips/Wipro).
Fixing only outdoor light fitting complete with all accessories to be fixed /projected from the wall of the building incl. making holes/providing clamping arrangement & necy. GI reducer as required. S & F 40 mm GI pipe (ISI-Medium) quality 1.5 mtr. average length having suitable bend S & F necy. length of 1.5 sq. mm PVC insulated single core stranded annealed copper wire and making connections as required and mending good damages to wall incl. painting etc.
Fixing only street & flood light fitting with suitable tie clamps and MS plate for mounting on pole/tower or similar structure.
Supply & Delivery of following size of 1.1 KV grade XLPE/PVC insulated Al. armoured cable as per GS. (Polycab/Gloster/RR) . 2 core 10 sq. mm
2 core 4 sq. mm
Laying of 2 core 10 & 4 sq. mm Al. armoured cable in underground trench 460 mm wide x 760 mm average depth with brick protection on the top of the cable with 08 (eight) nos. bricks per metre including filling the space between the bricks & cable and also the trench with shifted soil, leveling up and restoring surface duly rammed.
Laying of 2 core 10 sq. mm Al. armoured cable on wall/surface incl. S & F MS saddles with earthing attachment in 10 SWG GI (Hot dip) wire, making holes etc. as necessary, mending good damages and painting.
Supplying & fixing 25 mm dia GI pipe (ISI-Medium) protection with necessary fittings and jointing metarials as required.
Laying of 2 core 10 sq. mm cable through existing RCC/hume/GI pipe/open masonary trench.
Supplying and fixing compression type gland complete with brass gland, brass ring & rubber ring for dust & moisture-proof entry of following size ofXLPE/PVC Al armoured cables as below. 2 core 10 sq. mm
2 core 4 sq. mm
Finishing the end of XLPE/PVC armoured cable of following sizes by crimping method incl. supplying and fixing solderless socket (Make: Dowels), tapes, anticorrosive paste & jointing materials. 2 core 10 sq. mm
2 core 4 sq. mm
Supplyi & Delivery of 9.0 mtr. long steel tubular pole (410-SP-28) (113 Kg) as per GS. (Jindal/Utkarsh/Bajaj).
Erection of 9.0 mtr. long single steel tubular pole of size (0.6 x 0.6 x 1.70) mtr. with/without sole plate & cap etc. in CC foundation (Proportion and dimension indicated below), having (600 x 600 x 150) mm thick CC (4:2:1) base block below sole plate/pole with hard jhama metal including CC (6:3:1) muffing 0.30 mtr. dia and 0.30 mtr. above ground level including 3 mm thick neat cemented finish and GI earth bolt after making drilled holes etc. on pole & carriage of pole upto 1.6 km from Store to work-site including filling up the excavated earth pit with shifted soil and ramming properly.
Fixing outdoor type fluorescent/SV/MV light fitting on pole including S&F 40 mm dia x 1.68 mts. long GI Pipe (ISI-Medium) bracket with 40 mmx10 mm thick, MS clamp etc. and providing wiring with 2x1/1.40 PVC insulated and sheathed wire (single core) from loop box at the base of pole to light fiting through pole & bracket (without control switch) including making connections & painting.
Supplying & fixing GI waterproof type looping cable box of size (200 x 150 x 100) mm deep having 4 mm thick comprising of one 250 V, 15 A kit-kat fuse unit, one NL on porcelain insulator, one compression type brass cable gland for 2 core 6 sq. mm PVC/A cable and having lined with rubber gasketted GI top cover with brass machine screws etc., earthing terminal with lug on steel tubular pole near base including S & F (40 x 6) mm thick, MS clamps with bolts, nuts etc. including painting with anti corrosive paint.
Supplying & fixing of 240 V time sensor switch consisting of the following accessories: A) 240 V, 32 A, DP MCB of breaking capacity 10 KA & C characteristics - 01 no. (Make: L & T), B) 24 hour digital timer switch (Make: L & T) - 01 no., C) 240 V 25A DP power contactor (Make: L & T) - 01 no., D) Auto manual toggle switch - 01 no., E) 240 V, 20 A, SP MCB of breaking capacity 10 KA & C characteristics (Make: L & T) - 02 nos., F) LED indicator lamp - 01 no. red & 01 no. green in 2+8 way SPN MCB DB (Make: L & T) incl. lock & key arrangement concealed in wall after cutting the wall & mending good the damages to original finish incl. interconnection with suitable size of Cu wire & provision for earthing attachment.
Supply and delivery of Twin LED tube light with Fitting (20Watt, 230VAC, 50hZ, 4000K NW, THD<10%, bult in 2.5KV SPD) with all accessories and 2 nos LED Tube.[Make: PhilipsCrompton/Wipro].
Fixing only twin LED tube light fitting suspended 25 cm below the ceiling with 2 nos. 20 mm dia EI conduit (14 SWG) supports fixed with “L” type MS clamp whose one side fixed on ceiling with sutable size 4 nos. fastener and other side connected with the conduit with suitable size of bolts and nuts incl. S & F EI conduit, “L” type (125 x 125) mm, 6 mm thick and 25 mm with MS clamps and connecting the length of PVC insulated wire and mending good damages to original finish and painting etc. by 2 x 24/0.20 mm (1.5 sq. mm) flexible copper wire of 1.10 mtr. length.
Supply & Delivery 1200 mm sweep heavy duty AC ceiling fan (Crompton /Orient /Usha) complete with blades, canopy, fork, rubber bush, down rod, safety wire, P2 type capacitor etc.
Fixing only 1200 mm sweep AC ceiling fan complete with blades, canopy, fork, rubber bush, down rod, safety wire, S3 capacitor etc. incl. S & F connecting wire for down rod upto 30 cm incl. painting the rod with approved paint and making necessary connection as required by 2 x 1.5 sqmm flexible copper wire.
Extra for supplying additional wire for down rod & painting the rod exceeding 30 cm by 2 x 1.5 sq. mm flexible copper wire.
Supplying & fixing MS fan clamp of two piece type for RC ceiling as per approved specification, fabricated from 40 mm x 9 mm MS flat including making good damages to building roof with satisfactory finishing and painting. (As per Drawing no. 475 of PWD Specification Book – May 1991)
Supply & fixing socket type fan regulator (Step type) (Make: Anchor) on existing sheet metal switch board with bakelite/perspex top cover by screw after making housing for regulator knob by cutting bakelite/perspex top cover incl. making necy. connections etc.
Distribution wiring in 2 x 22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Polycab/RR Kabel) in 20 mm size PVC rigid conduit 'FR' (Precision make), with 1 x 22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire for ECC, to light/fan/call bell points with piano key type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall complete with 2 nos. suitable size “Ph & N” copper bar including bakelite/perspex (wall matching color) top cover 3 mm thick and incl. (175 x 100 x 65) mm inspection box, making earthing attachment, painting the MS box and mending good the damages to original finish. (06 nos. tube light + 06 nos. ceiling fan = Total 12 nos. points) Average run 6 mtr.
Distribution wiring in 1.1 KV grade 22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire (Finolex/Polycab/RR Kabel) in 20 mm size PVC rigid conduit 'FR' (Precision make), with 1.1 KV grade 1 x 22/0.3 (1.5 sq. mm) single core stranded 'FR' PVC insulated & unsheathed copper wire as ECC, to 5A 3 pin flush type plug socket & piano Kky type switch fixed on MS CRC sheet metal (16 SWG) switch board cum JB on wall including bakelite/perspex (wall matching color) top cover 3 mm thick and including painting the MS box and mending good the damages to original finish. (On board)
Excavation of soil for installation of earth electrode and filling & ramming. (For soft soil)
Earthing with 50 mm dia ISI-Medium GI pipe 3.64 mm thick x 3.04 mtr. long and 1 x 4 SWG GI (Hot dip) wire (4 mtr. long), 13 mm dia x 80 mm long GI bolts, double nuts, double washers incl. S & F 15 mm dia GI pipe protection (1 mtr. long) to be filled with bitumen partly under the ground level and partly above ground level driven to an average depth of 3.65 mtr. below the ground level.
Extra for providing masonery enclosure on the top of the earth electrode of overall size 86.36 cm x 86.36 cm x 46 cm deep (below ground level) complete with cemented brick work (1:6) of 25 cm width duly plastered with cement morter (inside) CI hinged inspection cover of size 36.56 cm x 35.56 cm with locking arrangement, GI reducer including drilling of 46 nos. 12 mm dia holes on the GI pipe.
Supplying & fixing earth busbar of galvanized (Hot dip) MS flat 40 mm x 6 mm on wall having clearance of 6 mm from wall including providing drilled holes on the busbar complete with GI bolts, nuts, washers, spacing insulators etc. as required.
Connecting the equipments to earth busbar including S & F GI (Hot dip) wire of No. 10 SWG size on wall/floor with staples buried inside wall/floor as required and making connection to equipments with bolts, nuts, washers, cable lugs etc. as required and mending good damages.
S D ENTERPRISE (BID ID -5648418)
Prava Enterprise (BID ID -5662328)
KANJILAL and SONS (BID ID -5637727)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .