| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L-1₹29.1 LAccepted-AOC R N COLONY PO BIRPARA DIST ALIPURDUAR W B PIN 735204 | ALIPURDUAR | WEST BENGAL | 735204 | ₹29.1 L Quoted ₹29.3 L | L-1 | Accepted-AOC Being L 1 |
| 2 | L-2₹29.5 L+₹19,706.45 (0.67%)Rejected-Finance NEAR KRIPAN GATE PO BINNAGURI DIST JALPAIGURI W B PIN 735203 | JALPAIGURI | WEST BENGAL | 735203 | ₹29.5 L+₹19,706.45 (0.67%) | L-2 | Rejected-Finance Being L 2 |
| 3 | L-3₹29.9 L+₹60,963.35 (2.08%)Rejected-Finance | ₹29.9 L+₹60,963.35 (2.08%) | L-3 | Rejected-Finance Being L 3 |
| 4 | L-4₹31.0 L+₹1.7 L (5.92%)Rejected-Finance NEAR KRIPAN TCP GATE PO BINNAGURI DIST JALPAIGURI PIN 735203 W B | JALPAIGURI | WEST BENGAL | 735203 | ₹31.0 L+₹1.7 L (5.92%) | L-4 | Rejected-Finance Being L 4 |
Tender Value
Refer Docs
EMD Value
₹60,000
Closing Date
13 Jan 2021, 6:00 pmClosed
GE North Binnaguri
GE North Binnaguri Post Binnaguri Dist Jalpaiguri West Bengal 735232
SPECIAL REPAIRS TO BUILDING NO P 43 AND CERTAIN MINOR AND REVENUE WORKS AT CERTAIN AREA UNDER GE NORTH BINNAGURI
2020_MES_390638_3
NIT No . 8701/25/14/E8 2020-2021
Open Tender
Miscellaneous Works
Item Rate
180 days
Binnaguri
As per tender documents
8 documents required · 8 mandatory
₹500
GE(N) Binnaguri
₹60,000
Yes
27 Jan 2021
29 Dec 2020
15 Jan 2021
29 Dec 2020
13 Jan 2021
30 Dec 2020
Amount
SCHEDULE A CIVIL WORKS Dismantling of asbestos cement ( corrugated, semicorrugated ,etc.) sheets in roof coverings including ridges, removing of unserviceable material from work site complete all as specified and as directed.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in roof covering/ cladding to wall, fixed with self tapping screws as specified.
Supply and fixed Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50mm thick of an colour having tensile strength of 550 Mpa as in as in ridges, valley, eaves, etc with self tapping screws as specified.
Taking down cement plaster on brick or stone walls etc. including racking out joints, hacking for key, scrubbing down with water, any description etc.including removing of rubbished material from work site complete all as specified.
Material and Labour for rendering 15 mm thick on fair face of brick or concrete surfaces finishing surfaces even and smooth without using extra cement in Cement mortar 1:6 all as specified and directed.
Material and labour for rendering 5mm thick on concrete surfaces in ceiling , in cement and sand mortar 1:3 finishing surfaces even and smooth without using extra cement complete all as specified
Material and labour for rendering 15 mm thick (10+5) in two layers on other than fair faces of brick work or concrete surfaces , in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions (WPC shall be apply in second layer and measured and paid separately) complete all as specified top surfaces finished even and smooth without using extra cement complete all as specified.
Supply only Integral liquid water proofing compound conforming to IS-2645-2003 complete all as specified.
Material and labour for preparation of new plastered or unplastered surafces of wall and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of new plastered or unplastered surafces of ceiling and applying three coats of white wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of new/untreated surfaces/ of walls and applying applying two coats of colour wash including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old surfaces of walls by complete removal of existing treatment and applying wall care white putty and sand papering surfaces to achieve smooth surfaces and applying two coats of acrylic based distemper emulsion over a coat of primer, white or tinted including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying two coat of colour wash on old decorated surfaces of walls including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of wall by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of wall including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old plastered or unplastered surfaces of ceiling by brooming down or steel wire brushing ; scrapping down smoke soot , moulds, moss and efflorescent salts and treating oil and greasy spots and applying one coat of white wash on old decorated surfaces of ceiling including washing floors, cleaning glass, joinery,electrical fittings, wiring etc. , of drops and splashes complete all as specified .
Material and labour for preparation of old painted steel and iron surfaces of any description , not otherwise described,over 10 cm width or girth and painting one coat with synthetic enamel paint including cleaning, stopping and rubbing down and removing all drops etc. complete all as speciified.
Material and labour for preparation of old painted wooden /wood based materials surfaces of any description, not otherwise described, over 10 cm width or girth and painting one coat with synthetic enamel paint (1st quality) including cleaning, stopping and rubbing down and removing all dropings etc. all as directed.
Suppy and fixed in repairs, aluminium anodized louvered ventilators with glass louvers , without sash bars, of aluminium sections weighing 0.55kg/m including necessary joining cleats, glazing clips, rubber packing, anodised aluminium snap beading, screws, anodised aluminium fittings and with suitable locking arrangements tc.complete all as specified.
Supply and fixed mild steel framed work such as grills , gratings, etc., with ends of bars shouldered and/ or riveted, or forged in to spikes; framed guard bars ; barred iron doors; ladders; framed balusters ; walk ways ; railings; frame work of water tanks and similar work conforming to Fe-290-Gde E-165 complete all as specified and directed.
Demolition of cement concrete ( unreinforced ) in ground floors and pavings not exceeding 15 cm thick above or below ground level, including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.
Material and labour for 75mm thick PCC (1:3:6), type C-2 (using 40 mm graded crushed stone aggregate ) as in plinth protection; pathway / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified.
Dismantling floor, hearth or wall tiling including cement mortar bedding ( but not backing), in floors, aprons etc .laid dry or laid dry and pointed including removing of demolished material from work site at any distance outside MD land complete all as specified and directed.complete all as specified.
Material and labour for glazed ceramic coloured/ digital print tiles size (300 x 450 mm 6 to 7 mm thick ) as in vertical surfaces such as skirting/dado / riser to steps etc conforming to IS - 13712 grade IB-III set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles over and including cement screed bed / backing layer of 10mm thick in cement mortar (1:3) complete all as specified and as directed. ( screed bed shall also deemed to be included in the quoted rate by the contractor ).
Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in floors etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match. over and including 15 mm thick screeding in CM 1:6 complete all as specified ( screed bed shall not be measured and paid separately).
Material and labour for Non Skid ceramic coloured tiles (1st quality) 7 to 8mm thick ( square/ rectangular) area of each tile exceeding 0.18 sqm but not exceeding 0.38 sqm, in skirting/ dado etc. set and jointed in neat cement slurry and pointed in white or coloured cement to match over and including 10 mm thick screeding in CM 1:3 complete all as specified ( screed bed shall not be measured and paid separately).
Material and labour for machine cut Kota stone slab as in flooring, 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 20 mm thick screed bed in CM 1:6 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Material and labour for machine cut Kota stone slab as in skirting / dado verticle surface 18-20 mm thick over cement screed base laid and jointed with grey cement slurry mixed with pigment to match the shade of the slab including rubbing and polishing complete over and including 10 mm thick screed bed in CM 1:3 complete all as specified.( Note Screed bed shall not be measured and paid separately).
Dismantling wall and ceiling boards ( fibre, pulp, insulation ,etc. ) or insulation boards/slabs/blankets, any thickness, including cover fillets complete all as specified.
Material and labour for false ceiling with GI powder coated frame work and 4 mm thick, (E-board) non asbesto fibre reinforced cement board , Reinforced Designer Board tiles conforming to IS-14862 and ISO-8336 , of approved texture at all height duly suspended ceiling laid on hot dip galvanised iron imposed grid of size 600 mm x 600 mm, T section / Angle section including cutting holes in brick wall and making good surface with cement concrete 1:2:4 type B-0 / 1:3 cement mortar complete all as specifiedand having following details: (a) 27mm x 27 mm angle 0.55 mm thickness, GI powder coated hot dip galvanised plugged at the rate 600mm centre to centre alongwith the perimeter of wall. (b) 25 mm x 25 mm Tee 0.55 mm thickness, GI powder coated hot dip galvanised as main and cross runner suspended with 1.6 mm dia GI wire suspendrs (not exc. 1.20 mtr length) with adjustable clamps and dash true fastners plugged in RCC slab or angle iron runner of slopped roof placed at the rate 600 mm centre to centre alongwith the perimeter of wall. Note: The work shall be carried out as per manufacturer instruction and as directed.
Taking down chowkats with shutter (without taking off shutter from the frame) exc 1.5 Sqm but n exc 4 sqm each etc including removing material from work site complete all as specified and directed.
Taking down chowkats with shutter (without taking off shutter from the frame) n. exc 1.5 Sqm each etc including removing material from work site complete all as specified and directed.
Supply and fixed rolled mild steel in framed work as in doors or gates of angle or other section with gusset plates, rails, braces,etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc., to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings ( exclusive of steel sheeting or other covering, running rails and guides) and hanging; also fastening grade Fe-410 (Gde-E-250) quality- A complete all as specified.
Material and labour for mild steel flat iron, as in wind ties or as in hold fast, hooks for hanging fans , clamps, supports for rainwater, ventilating pipes, including bolts,including drilling holes, notching for wire , etc.; flat iron fillets ( for securing wire mesh etc. including all necessary drilling , bolting or rivetting , etc., and similar work conforming to Fe-290-Gde E-165 all as specified and directed.
Supply and fixed 35 mm thick factory made door Flush shutters , solid core construction, with particle board core and plywood face panels, commercial type on both sides complete all as specified and directed.
Material and labour for plain cement concrete type B-1 (1:2:4) using 20 mm graded crushed stone aggregate as in copings, benching, covings, holdfast, bed plates and like as directed including necessary form work complete all as specified and directed.
Supply and fixing 300 mm long Aluminium alloy. Anodised, sliding door bolt with hasp, staple ( bolt type) and fixing clips of sheet , cast or extruded sections and fixing bolts and sliding bolts of extruded sections or cast aluminium alloy and fixed complete all as specified.
Supply and fixed of 100 mm long medium weight, cold rolled mild steel butt hinges( ISI Marked) complete all as specified and directed.
Supply and Fixing of aluminium handle cast type anodised 150 mm size etc complete all as specified and directed.
Supply and fixing of aluminium, anodised, barrel tower bolts of extruded section and fixed, 150 mm length of bolt complete all as specified.
Material and labour for preparation of untreated new wooden surface of any description over 10 cm width or girth, not otherwise described and applying two coats of synthetic enamel paint, (1st quality) with a coat of pink primer all as specified and directed.
Supply and Fixing solid PVC door frame of size 50 mm X 47 mm made out of 5 mm plain colour PVC sheet reinforced with MS square tube supply & fixing in opening as per specification & drawing and as directed.
Supply and Fixing factory made solid panel PVC door shutter 30 mm thick (style) consisting of frame made out of MS tubes for top & bottom rails. MS frame shall be covered with heat moulded plain colour PVC 'C' channel having a PVC sheet strip of 20 mm width stuck inside with solvent cement for stiles and plain colour PVC sheets for top rail, lock rail and bottom rail on either side as gap insert for top rails bottom rail, panelling of plain colour PVC sheet to be fitting in the MS frame welded/sealed to the stiles & rails with suitable PVC sheet beading and joined together with solvent cement, supplying & fixing in the frame at site as per specification and drg and as directed.
Supply and fixed of 100 mm long medium weight, stainless steel butt hinges( ISI Marked) complete all as specified and directed.
Supply and Fixing of aluminium handle cast type anodised 125 mm size etc complete all as specified and directed.
Supply and fixed in repairs for fixing over crumple joints of 0.63mm thickness Plain, galvanised, mild steel sheeting, in ridges, hips, valley gutters, drip and straight flashings (length and girth as fixed) with grade of zinc coating 275 with screws complete all as specified and as directed.
Supply and fixed rotational moulded poly-ethylene multilayer water storage tanks ( cylinderical vertical with closed top ) 500 itres capacity ,hoisted and fixed in position, including taking down unservicable water tank and ball valve complete all as specified.
Supply and fixed ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe and fixed (Minimum weight 210 gms complete , screwed for 20 mm bore dia. pipe or brass ferrule complete all as specified.
Supply and fixed in repair Gunmetal , globe or gate valves, with iron wheel head, screwed both ends for 20 mm bore dia. iron pipe and fixed complete all as specified.
Supply and fixed in repairs vitreous China white Squatting pan ,'Orissa' pattern size 580 mm x 440 mm with integral footrests water closet) with 'P' or 'S' trap front or back inlet complete including lime concrete for bedding, connection to drain pipe and to flushing pipe , anti syphonage pipe etc complete all as specified.
Supply and fixed in repairs low level flushing cistern (dual-flush), 9-10 litres capacity ISI marked embossed moulded from virgin poly propylene including flush pipe complete all as specified and directed.
Supply and fixed in repairs chromium plated Tubular towel rail, 20 mm dia. D type, 60 cm long between flanges complete all as specified.
Supply and fixed in repairs stainless steel soap dish/ tray fixed in walls complete all as specified
Supply and fixed in repairs chromium plated bib taps cast copper alloy with crutch handle, fancy type, screwed for 15 mm bore dia. iron pipe or for brass ferrule and fixed complete all as specified .
Supply and fixed in repairs pillar taps, fancy type, cast copper alloy , with capstan heads, chromium plated , screwed down for 15 mm bore pipe,high pressure , with or without l'ettered ' 'HOT' or 'COLD' with long screwed shanks and fly-nuts , screwed for iron pipe complete all as specified.
Supply and fixed in repairs angular stop cock screwed down for 15 mm bore dia. pipe, high pressure, with crutch handle, with flange screwed externally both ends for unions etc. and fixed complete all as specified
Supply and fixed fixed in repairs Cast Brass chromium plated shower rose 125 mm size with or without swivel joints, any size, including fixing to steel pipe or union in repairs complete all as specified.
Supply and fixed in repairs of stop valve 15 mm dia CP fancy type, with long shank and cup (concealed type) cast copper alloy, screwed both ends for iron pipe or for unions complete all as specified and directed all as specified and directed.
Supply and fixed in repairs PTMT connections 15 mm size with PVC nuts of length 450 mm complete all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing and removal of unserviceable pipe from work site,15 mm bore dia all as specified.
Taking up or down steel tubing and connections, including cleaning for re-fixing and removal of unserviceable pipe from work site, 20 mm bore dia all as specified.
Material and labour for 15 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
Material and labour for 20 mm nominal bore Mild steel galvanised water tubing , medium grade , with all fittings and fixed complete to walls and ceiling or laid in floors complete all as specified.
Supplu and fixed in repairs 20 mm dia chromium plated curtain rod fixed with brackets decorative ends complete all as specified.
Taking down eaves gutters and AC/PVC/CI soil pipes ( any size or pattern) , including all fittings , heads, shoes, bends, swan necks, etc., including cleaning for refixing or removal to store ( measured overall as fixed along the centre line over fittings).
Supply and fixed 110 mm bore PVC (SWR) pipes single socketed ISI marked IS-13592, type 'B' in any length with rubber ring joints laid in trenches / floor complete all as specified.
Supply and fixed 75 mm bore PVC (SWR) pipes single socketed in any length with rubber ring joints laid in trenches / floor complete all as specified.
Supply and fixed PVC (SWR) bends 110 mm bore with access door complete all as specified
Supply and fixed PVC (SWR) vent cowl 100 mm bore complete all as specified
Supply and fixed PVC nahani/floor trap, plain with PVC grating including jointing with solvent cement cement concrete/cement mortar 1:3, 75 mm dia. outlet complete all as specified.
Supply and fixed in repairs of grating doom 100 mm dia of PTMT (Minimum weight 25gms) complete all as specified.
Supply and fixed in repair PVC waste pipe with CP waste coupling including flexible suitable for wash hand basin or urinal, 32 mm dia complete all as specified.
Supply and fixed in repairs vitreous china wash basin (WHB) , white , flat back , size 550 mm x 400 mm (1st quality) including brackets, waste fittings , brass Chromium plated for glazed basins etc. with long screw shanks and fly nuts , flange end embedded in red lead cement , including cutting for and pinning in ends of brackets or erecting stand but but incl providing brackets, waste pipe & CP waste coupling complete all as specified and as directed.
Taking down existing tarfelt including tiles, lime concrete and screed bed complete from roof surfaces including parapets and lowering and removing the same to a distance exc. 50m and n. exc. 100m including roughening of old concrete surface of roof , cleaning the surface by wire brushing to remove all loose dust etc complete all as specified and directed.
Material and labour for 15 mm thick screed bed in CM 1:4 withacrylic polymer modified fibre reinforced waterproof coating brushbond Roof Guard @ 3 % by weight of cement on roof slab as per manufacturer instruction and maintaining the slope and finished the surface even and fair without using extra cement complete all as specified. Note: WPC is deemed inclusive.
Material and labour for water proofing treating to RCC roof with providing and applying single component acrylic polymer modified, fibre reinforced waterproof coating brushbond Roof Guard in 3 coats (white, grey and terracotta) of application @ 0.5 litre /sqm coat, including sprinkling of clean sand (300 microns - particle size).The product should have following properties solid content : 70%, tensite strength (ASTM D 412): 1.10 MPs, elongation (ASTM D12) : 100% Resistance to ageing due to UV radiation . 1000 hours no change rapid chloride penetration : very low resistane to algae growth passes, zero rating / permeability (mm): 5.0 water vapour transmission : 6.0gm/sqm h No of coats : 3 (minimum) adhesive bond strength : > 0.92 N/mm2 complete all as directed.
Dismantling posts or struts (wood, steel or R.C.C.) any section embedded in natural ground , including taking out embedded portion and making good disturbed ground complete all as specified. ( Note :- the vertical height above GL shall be measured for the purpose of payment towards work done)
Excavating in post holes in soft/ loose soil ( or similar holes) each n exc 0.5 cu.m. getting out, returning,filling in and ramming earth or broken rubble mixed with earth around , in layer not exceeding 25 cm, watering and removing surplus soil to a distance n.exc 50 M complete all as specified.
Dismantling of mild steel Galvanised, 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings, including removing of rusted unserviceable wire from work site and keep serviceable wire for reused in safe custody all as directed.
Material and labour for Mild steel Galvanised, (hot dipped galvanised) 2 strand, steel barbed wire 2.24 mm dia barbed with 2 mm dia barbs at 75 mm spacings and straining and fixing to any type of standard rails straining bolts , including,securing or tying at crossings with and Provision of galvanised mild steel wire , staples or steel pins etc. as directed ( each line wire to be measured) all as directed.
Material and labour for plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in foundations, filling and mass concrete complete all as specified and as directed.
Supply and fix mild steel work as in posts and struts in fencing including cutting tops to shape as directed, drilling holes, notching for wire, etc; flat iron fillets ( for securing wire mesh etc.) including all necessary drilling, bolting or riveting, etc., and similar work conforming to Fe-290-Gde E-165 complete all as specified and directed.
Material and labour for Mild steel bars 10mm dia and above, cut to length, bent to shape required, including cranking , bending , hooping ends as horizontal runner(tie) to fix chain link fencing, etc complete all as specified & as directed.
Supply only 3.7 mm dia galvanised steel wire, (Hot dipped galvanised), 100 mm x 100 mm mesh, made up into mattresses or cages, all as specified.
Fixing only chain link fencing to post old and new including line wires, any mesh , size and type to any type of standards, rails, straining bolts, etc. including provision of binding wire all as directed.
Material and labour for Mild screw bolts ( Machine made) with hexagonal or square heads at one end and screwed the other, or screwed both ends , each screwed end to be fitted with washers and one hexagonal or square nut, exc 5 but n exc 10cm long and 5 to 10 mm dia. of shank complete all as specified.
Material and labour for preparation of new steel surfaces of any description not otherwise described not exc.10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over one coat of red oxide Zinc chrome primer complete all as specified.
Supply and fixed Steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I.S 1161-1979 grade St. 240 complete all as specified.
Material and labour for preparation of new steel surfaces of any description not otherwise described over 10 cm width or girth and applying two coats of synthetic enamelled paint (1st quality) over one coat of red oxide Zinc chrome primer complete all as specified.
Material and labour for plain cement concrete 1:3:6 type C-2 using 40 mm graded crushed stone aggregate as inin roof kerbs, in lintals upto 1.5m clear span, cills, steps; seismic and other similar bands, plinth courses, string courses, lacing courses, parapets and railing upto 60 cm in height, copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering , slightly rounded or chamfered angles and throating, as directed.
Excavating over areas , n exc 1.5 m deep and getting out for foundations etc. or for shafts, well cess pits, manholes,pier holes,etc. but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified.
Excavating in trenches, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes,sewage line, UG cables etc. but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified.
Removing excavated material ( soils) not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 m above the starting point complete all as specified.
Returning ,filling in , including spreading , levelling , watering and well ramming in layer not exceeding 25 cm thick in soft/ loose soil complete all as specified.
Material and labour for plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in foundations/mass concrete complete all as specified.
Material and labour for reinforced cement concrete type M-25, Design Mix (20 mm graded aggregate) in foundations, including rafts, footings, foundation beams; plinth beams; bases for columns, etc; basement slabs, under reamed piles and mass concrete complete all as specified. Note : Design Mix shall be as per approved Design Mix of CWE/CE's running contracts.
Material and labour for reinforced Cement concrete M-25 (Design mix), 20 mm graded crushed stone aggregate) in columns, pillars, piers, posts and struts complete all as specified. Note : Design Mix shall be as per approved Design Mix of CWE/CE's running contracts.
Material and labour Mild steel bars ( TMT) 8mm dia. and over up to and including 10 mm dia. in stirrups, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns , hooking ends and binding with and including mild steel wire ( annealed) not less than 0.90 mm dia. Or securing with clips complete all as specified.
Material and labour for use and waste formwork to sides of concrete foundations, footings, bases of columns , raft nd raft beams, sides and soffits ( if any) of foundation and plinth beams; and similar work; vertical or to batter of concrete surfaces rough finished complete all as specified.
Material and labour for use and waste formwork Squqare, rectangular or polygonal to sides of concrete pillars, posts, struts, piers, columns and stanchions finished surface complete all as specified.
Material and labour for use and waste formwork Squqare, rectangular or polygonal to sides of concrete pillars, posts, struts, piers, columns and stanchions finished surface complete all as specified.
Material and labour for use and waste formwork sides and soffits of floor or roof beams, beam haunchings, girders,bresumers, lntels, cantilevers, shelves including supports, overhangs, etc. also splays between floors and beams etc. finished surface complete all as specified.
Material and labour for brickwork with fly ash bricks, old size, having compressive strength 75Kg sqcm, straight or curved on plan excd 6 M mean radius in built in cement and sand mortar 1:6 complete all as specified.
Material and labour for brickwork with fly ash bricks, old size, having compressive strength 75Kg sqcm, straight or curved on plan to any radius in half bricks built in cement and sand mortar 1:4 complete all as specified.
Material and labour for rendering 15 mm thick on than fair faces of brick work or concrete surfaces in cement and sand mortar 1:4, finished even and smooth without using extra cement complete all as specified and directed.
Material and labour for preparation of newly plastered or unplastered surfaces of walls and applying two coats of cement base paint, white or tinted over one coat of alkaline resistant primer ( before application of cement base paint) of walls including washing floors, etc. , of drops and splashes complete all as specified .
Supply and fixed rolled mild steel in roof trusses, ( framed), trussed purlins, crane gantries, rails and fastenings and heavy bracket framing ( Beam, tee,angle,channel or flat sections ) including distance pieces , cleats etc. grade Fe-410-W ( Gde-E-250) quality -B complete all as specified.
Material and labour for Hardcore of gauge n exc. 63 mm , stone or boulders, deposited , spread and levelled in layer n exc. 15 cm thick, watered and rammed to a true surface complete all as specified.
M&L 75mm thick, plain cement concrete 1:4:8 type D2 using 40 mm graded crushed stone aggregate as in sub base complete all as specified.
Material and labour for plain cement concrete type B-0 (1:2:4), using 12.5 mm graded crushed stone aggregate, 40 mm thick , as in sub base flooring finished even and rough complete all as specified.
Material and labour for 75mm thick PCC (1:2:4), type B-1 (using 20 mm graded crushed stone aggregate ) as in plinth protection; pathway / hardstanding etc laid in bays / panels not exc. 2.00 Sqm each including construction joints at suitable interval and each corner and filled with bituminous mastic filling (1 part bitumen & 3 part sand) and finished the surface even and smooth without using extra cement complete all as specified.
Supply and fixed 105mm x 60mm pressed steel frames for doors with one or more rebates including necessary fixing lugs, hinges, lock strike plate, etc, complete, as specified,
Supply and fixed 35 mm thick factory made plain framed made out of 2nd class hardwood , panelled shutter ( two panel) with lock rail and panel of 12 mm veneered particle board with commercial veneering on both faces. The size of rail and stile as per IS: 1003 ( Part I), kiln seasoned and chemically pressure treated complete all as specified and directed.
Supply and fixing 3 mm thick (nominal) Sheet glass, ordinary quality , in squares, not exceeding 0.50 sqm each each pane fixed with oil putty complete all as specified.
Supply and fixed steel ventilator with top hung shutter including hinges, steel peg stay , 3mm thick, 100 mm long copper oxidised finished mild steel handle and 3 mm thick 300 mm long mild steel copper oxidised finished peg stays,dovetailed or welded including factory priming coating complete all as specified.
Excavating in trenches, not exceeding 1.5 m wide and exceeding 1.5 m and not exc. 3.0 m in depth; for foundations etc. or for shafts, well cess pits, manholes,pier holes,sewage line, electric pole, UG cables etc. but not exceeding 10 sqm on plan getting out in soft/loose soil complete all as specified.
Material and labour for cutting and demolition of SWG sewer pipe in damaged portion alongwith concrete bedding including removing from site as directed and S&F new salt glazed stone ware drain pipes, grade ‘A’ placed in position in old sewer line and jointed in cement mortar (1:1) including packing under and haunching against the sides of the new pipes with PCC (1:3:6) type C-2 with using 40 mm graded stone aggregates for the 150 mm dia (Internal) of sewer pipe lines complete all as specified and as directed
Material and labour for cutting and demolition of SWG sewer pipe in damaged portion alongwith concrete bedding including removing from site as directed and S&F new salt glazed stone ware drain pipes, grade ‘A’ placed in position in old sewer line and jointed in cement mortar (1:1) including packing under and haunching against the sides of the new pipes with PCC (1:3:6) type C-2 with using 40 mm graded stone aggregates for the 200 mm dia (Internal) of sewer pipe lines complete all as specified and as directed
Material and labour for cutting holes in brick walls incement mortar for inserting holdfasts and making good dismantled portion in PCC 1:2:4 type B-1 and finished with cement mortar 1:4 cement mortar 1:3 Exc. One brick but not exc. Two bricks complete all as specified .
Supply and fixing of factory made precast RCC manhole cover of M-25 grade including reiforcement of dia 500 to 550 mm with and including frame/ring beam complete all as specified and as diretced.
Suppy and fixed, powder coated anodised aluminium frame (sections weighing not less than 0.55kg/mtr) made of Square/tubular Aluminium section for door with one or more rebates jointing cleat for fixing etc and provision of aluminium door shutter (Single/Double shutter) including necessary jointing cleats glazing clips, rubber gasket aluminium anodised snap beading, screws, hold fast, Aluminium hinges 3Nos 100mm long for each shutter, floor stopper, locking arrangements handle, 5.5mm thick tinted glass fixed in panels with aluminium guard bar complete all as directed.
Suppy and fixed, Mortice latch of length 75 mm with two levers ( verticle type) , aluminium anodised body and fixed complete all as directed.
Material and labour for brickwork with Firebrick work in linings to fire places, flues, etc. (Other than in chimney shafts), set, jointed and pointed in fireclay complete all as specified.
Material and labour for brickwork with Firebrick work, in lining to chimney shafts), set, jointed and pointed in fireclay complete all as specified.
Material and labour for rendering 15 mm thick on fair faces of brick work or concrete surfaces, in cement and sand mortar 1:4 using water liquid water proofing compound @ 200 ml per bag of cement or as per manufacturer's instructions (WPC shall be measured and paid separately) surfaces finished even and smooth without using extra cement complete all as specified.
Supply and fixed mild steel Bands, straps, supports or stays for rainwater , Ventilating pipes, including bolts , if required; hooks ( stay), heavy, for large gates; hook and pintol hanges; large hasps and staples ; chains; hand made sliding bolts; clamps; hold fasts; wall ties; hooks for hanging fans; plain angle cleats for securing purlins to wood trusses or rafters ; knee piece inserts; two way and three ways straps , plate washers and similar small articles conforming to Fe-290-Gde E-165 complete all as specified and directed.
INTERNAL ELECTRIFICATION Taking down carefully aluminium conductor point wiring (light,fan,socket or power) complete including fittings such as switches,ceiling roses, pendants, regulators ,sockets etc. and removing (except those to be reused shall be kept in safe custody at the site ) and making good disturbed surfaces of walls, floors etc.to match with the existing complete all as specified.
Material & Labour for point wiring with 1.50 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable of working voltage 1100 volts grade conforming to IS-694 Pt I & II of 2000 drawn through and including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with all accessories (including cutting chases & making good the disturbed surface to its original specification), including provision of 1.5 Sqmm (nominal cross sectional area) PVC insulated (FRLS) unsheathed single core multi stranded copper conductor cable as earth continuity conductor, connected to main switch / DBs or common earth dolly for one light / fan point / exhaust point controlled by one 5 Amps one way switch complete all as specified and as directed for light /fan point controlled by one way switch 5/6 amps. Note: Red coloured cable shall be used for live connection, black coloured cable shall be used for neutral connection and green coloured cable shall be used for earthing. Separate cable for earthing and neutral to be used for each individual circuit from the distribution board.
All as per item No.128 here-in-before but for one socket out let 5/6 amps point on the independent board
All as per item No.128 here-in-before but One 3 pin 5 Amps socket out let points on same board with other switch.
Material and labour wiring for 5/6 pin 6/16 Amp switch socket combination on independent boards controlled by one, one way switch using 2.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables in and including 20 mm dia or higher size PVC conduits and fittings, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 2.5 sqmm nominal cross sectioanl area multistranded copper conductor , PVC insulated unsheathed FRLS earth wire and connecting to earth dolly and brass screws, washers etc. including cutting chases pinning in for concealed conduit wiring and making good of disturbed surface n exc 15 cm girth complete all as specified.
Supply and fixed switch piano flush type, single pole , 6 Amps, one way complete all as specified.
Supply and fixed switch socket combination 2 in 1 multipurpose 5 pin , (6 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed socket outlet, 2 in 1 ,5 pin, 5 Amp, flush type complete all as specified.
Supply and fixed socket combination 2 in 1 , 6 pin , (6 Amps & 16 Amps ) flush type controlled by one switch complete all as specified.
Supply and fixed socket, 6A 2/3 pin combined 2 module 5/6 amps, any type complete all as specified and as directed.
Supply and fixed switch piano flush type, single pole , 15/16 Amps, one way complete all as specified.
Supply & fixed ceiling rose surface bakelite 65 mm x 50 mm two to three terminal suitable for 230 Volts AC 6 Amps complete all as specified.
Supply & fixed lamp holder, PVC/polycarbonate type with back plate straight or anfular suitable for batten fittings complete all as specified.
Supply & fixed stepped type electronic fan regulator flush type 120/280 Volts ISI marked complete all as specified .
Taking down carefully aluminium conductor point wiring socket or power in same board complete including taking down of socket and removing (except those to be reused shall be kept in safe custody at the site ) complete all as specified.
Supply & fixed LED white glass Lamp 1x14 Watts, 230V Base-22 complete all as directed.
Supply & fixed LED white glass Lamp 1x9 Watts, 230V Base-22 complete all as directed.
Supply and fixing in repairs of LED light fittings 1 x 18/20 watts 230 Volt white powder coated slim box type batten made of formed CRCA with snap on installer LED lighting fixture with and including 1x18/20 watt T8 double side connection retrofit LED tube with G13 lamp holders, connector block, complete with all accessories internally pre-wired and including connecting up with three core twisted flexible copper conductor cable up to cealing rose complete all as specified and directed.
Taking down ceiling fan any size from its location including disconnecting from ceiling rose, after removing carefully and cleaning body, blades, canopies with cloth and replacement of 3 core multistranded copper condutor and rehanging fan and false ceiling in position and making electric connection complete all as directed.
Materials and labour for Sub main wiring with 2 runs of 6.00 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FRLS) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly, drawn through and including PVC rigid non- metallic PVC consealed conduit ISI marked , medium garde of adequate size with all conduit accessories ISI marked as required complete all as specified and as directed including taking down old unserviceable / burnt / damaged one. [NOTE : Two run of sub main wiring cable along with one run of earth wire and one run of PVC Conduit / casing and capping shall be measured as one length]
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), triple pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed epoxy powder coated sheet metal enclosure for DBs, double door (when MCBs to be used), Single pole and neutral 240 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed MCB SPN 6-32 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB TPN 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply & fix sheet metal enclosure for 8 way Distribution Boards (DB’s), double door , single pole and neutral bus bar, including bus bar neutral link, earth bar and din rail, IP-43, IK-09 protection including gasket and door earthing suitable for fixing MCBs/isolators fixed on wall surface and making good the disturbed surfaces of wall and connecting up including taking down old unserviceable one complete all as specified and as directed.
Supply and fixed in repairs MCB SP, 6 to 32 Amps, 'C' series 10kA, 240 Voltsand to be housed in DBs including necessry connection complete all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs MCB SPN 32 to 63 Amps, 'C' series 10kA, 240 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs epoxy powder coated sheet metal enclosure for DBs, flameproof LM-6 (when MCBs to be used), srigle pole and neutral 415 V, 4 ways with mounting fitted with bus bar, DIN channel , neutral link and incoming contact complete all as directed.
Supply and fixed in repairs MCCB TPN 100 Amps, 'C' series 25 kA, 415 Volts and to be housed in DBs complete including necessry connection all as specified and directed. (Note :- Proper and suitable size cable lugs to be fixed with MCB are included in unit rate of each MCB of any rating).
Supply and fixed in repairs powder coated mild steel junction box factory made of size 350 mm (B) x 400 mm (H) x 200 mm(D) , made of CRCA sheet 2mm thickness, with front openable hinged door, locking arrangements mounted on porcelain insulator, glands and lugs etc. and making connections complete all as specified.
Supply and fixed in repairs powder coated mild steel junction box factory made of size 600 mm (B) x 900 mm (H) x 200 mm(D) , made of CRCA sheet 2mm thickness, with front openable hinged door, locking arrangements mounted on porcelain insulator, glands and lugs etc. and making connections complete all as specified.
Supply and fixed LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lend 35 Watts, 110 lumen per watt , heat resistant toughened glass, electronic driver, epoxy powder coated finish with all accessories duly prewired including removing of unserviceable fitting of any type complete all as specified.
Supply and fixed LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lend 45 Watts, 110 lumen per watt , heat resistant toughened glass, electronic driver, epoxy powder coated finish with all accessories duly prewired including removing of unserviceable fitting of any type complete all as specified.
Supply and fixed LED street light fitting made up of pressure die cast aluminium housing with high power LED as lighting source and lend 30 Watts, 110 lumen per watt , heat resistant toughened glass, electronic driver, epoxy powder coated finish with all accessories duly prewired including removing of unserviceable fitting of any type complete all as specified.
Disconnecting & taking out defective under ground LT cable from trenches, pole, pipe, floor ,wall etc including bricks ,GI pipes and removing from work site of unserviceable material and keep serviceable material for reuse in safe custody for any size complete as directed (Excavation/earth work shall be measured & paid separately under relevant item of this schedule)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured aluminium conductor cable 1100 volts grade 35 sqmm 3.50 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc including aluminium cable lugs, cable gland, nut & bolts with washer complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block and pipe shall be measured and paid separately under appropriate items)
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured aluminium conductor cable 1100 volts grade 10 sqmm 2 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc including aluminium cable lugs, cable gland, nut & bolts with washer complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block and pipe shall be measured and paid separately under appropriate items)
Material and labour for river sand, washed and screened dry for cushioning to under ground cable in trenches below and around under ground cable including spreading and levelling complete as specified and directed .
Material and labour for laying well burnt old size bricks, fly ash bricks, straight or curved on plan , laid flat with width equal to length of brick , laid dry over electric cable for protection all as specified.
Boring/Drilling ( horizontally) manually under existing road ( maximum 10 M in width) suitable for passing GI tubing of 40 to 100 mm bore complete all as specified.
Supplying and fixing Galvanised mild steel pipe /tubing, light grade complete with all fittings of 40 mm bore dia, laid in trenches / under roads, fixed to poles/ walls with Mild steel clamps , bolts , nuts and washers complete all as specified and directed. Note :- Excavation & Earth work shall be measured and paid separately)
Materials and labour for Sub main wiring with 2 runs of 2.50 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 2.50 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FRLS) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly, drawn through and including steel rigid metallic conduit medium garde of adequate size with all conduit ISI marked as in concealed as required including making good surface complete all as specified and as directed and taking down of old unserviceable wiring complete. [NOTE : Two run of sub main wiring cable along with one run of earth wire and one run of steel Conduit shall be measured as one length]
Materials and labour for Sub main wiring with 2 runs of 6 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core flame retardant cable (FRLS) of working voltage 1100 volts grade with stranded copper conductor including one run of 4 Sqmm (nominal cross sectional area) PVC insulated unsheathed flame retardant cable (FRLS) with stranded copper conductor as continuous earth wire connected to main switches DBs or in common earth dolly, drawn through and including steel rigid metallic conduit medium garde of adequate size with all conduit ISI marked as in concealed as required including making good surface complete all as specified and as directed nd taking down of old unserviceable wiring complete. [NOTE : Two run of sub main wiring cable along with one run of earth wire and one run of steel Conduit shall be measured as one length]
Supply and fixing in repairs LED Flame proof integral well glass lumaninaires with epoxy finish LM6 aluminium alloy housing with heat resistance and toughened glass cover built in control gear painted MS wire guard and eye bolt suitabble for LED fitting incl 1x16/20 wattt LED tube rod and fixing clamp/hook made out of TMT bar all as specified and as directed.
Supply and fixing in repairs flame proof enclosure conforming to IS 248-2004 protection as per IP-55 made out of cast aluminium alloy LM6 of electrical rating 16A/240V AC 50Hz with 16 Amp DP rotary type switch (flameproof type)-3 Nos with 3 cable entry 3/4" x 3 Nos complete for controlling 3 circuits complete all as specified and as directed..
Material and labour for earthing complete with galvanised mild steel earth plate electrode 600 mm x 600 mm x 6.0mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using GI wire lead 4 mm dia as earth wire electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth wire encased in and including 15 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Material and labour for earthing complete with copper earth plate electrode 600 x 600 x 3-15mm thick, burried directly in ground to a depth not less than 2.25 metres deep below ground level with top edge of earth plate not less than 1.5 metre below normal ground level surrounded with adequate quantity of charcoal dust mixed with salt to a packed thickness of 15 cm all around the plate, using copper strip 20 x 3 mm as earth strip electrode bolted or rivetted to earth plate at one end and connected to equipments at another end, GI earth strip encased in and including 40 mm dia GI 'light grade' pipe from upper end of earth plate upto equipments,20 dia bore GI pipe 'light grade' as water pipe from earth chamber to upper edge of earth plate, Test point , GI funnel with wire mesh fixed on water pipe and PCC 1:2:4 type B-1 (using 20mm graded stone aggregate) as in pit chamber and RCC pit cover 50mm thick precast RCC 1:2:4 type B-1, duly reinforced with MS round bars 6mm dia @ 100 c/c both ways with 10mm dia MS round bar as in lifting handles, excavation, earth work including laying the GI pipe concealed in floor/wall all as described in electric plate of SSR Part I complete all as specified and directed and testing on completion. Note :- If the desired earth resistance is not found, earthing shall be redone by the contractor at no extra cost to the department.
Supply and fixed in repairs for 25 x 3 mm aluminium strip, earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or burried in ground or fixed to poles or roof with saddle and screw complete all as specified and as directed.
Supply and fixing in repairs Air termination, single pointed aluminium rod 12 mm dia and 300 mm long fixed nwith 2 Nos suitable size of nut and bolt with washer all as specified and as directed.
Supply and fixing in repairs Test point terminal block made of gun metal or Phosphorus bronze size 75x75x25 mm, drilled and screwed including 3 nos. 8 mm dia. 25 mm long hexagonal head screw all as specified and as directed.
Supply and fixed heavy duty porcelain insulator to fixed aluminium strips on roof top, wall including PVC plug and gutties, screws complete all as specified.
Material and labour for plain cement concrete 1:3:6 type C-1 using 20 mm graded crushed stone aggregate as in foundation filling of road , plinth protection or bed plate of wall to fixed aluminium strips complete all as specified.
Supplying, laying, fixing 40 mm nominal bore dia,galvanized tube medium grade for fixing of air termination on roof top including necessary PCC for fixing of tube complete all as specified and as directed.
Supply and fixing street light bracket made out of GI pipe light grade 32 mm dia 1.2 mtr length bent to shape and reduced to required size at top upto 1.2 mtr length by cutting, welding and well finishing including MS clamp of flat iron of size 25 x 5 mm suitable length 2 Nos complete with drilling, hole, fixing with nuts bolts and washers including painted with two coats aluminium paint over a coat of red oxide primer complete all as specified and directed.
Supplying, transporting, erecting and fixing Steel tubular swaged poles type 410 SP-31 ( 9.0 metres long) complete with cast iron base plate, finial, taper plug, bolts, nuts and screws as specified, including necessary excavation and earth work , PCC 1:4:8 type D2 in foundations below pole, PCC 1:3:6 type C2 around poles and PCC 1:3:6 type C1 as in plinth block , disposal of surplus soil to a distance not exceeding 50 m and depositing where directed, painting steel tubular poles exposed surafces with Aluminium paint two coats over one coat of red oxide primer and providing 300 mm wide bands (3 bands/ straps with synthetic enamel paint and 2 bands with Black bituminous paint ) from plinth block and numbering of poles , painting embedded portion of poles with one coat of bituminous paint complete all as specified and directed.
Supply and fixed LED flood light fitting made up of pressure die cast aluminium housing with toughned glass and individual high power LEDs with secondary optics, IP 66 protection & impart resistance of IKO7 with operating voltage range of 140V to 270 V, 200 Watts, 110 lumen per watt complete with all accessories internally pre-wired and including connecting cable up to pole complete all as specified.
Supply, laying , testing LT underground electric power cable crossed linked XLPE insulated, galvanised steel strip or wire armoured / PVC insulated armoured aluminium conductor cable 1100 volts grade 16 sqmm 4 core laid in trenches / laid under floor or fixed to walls/on poles / in ducts etc including aluminium cable lugs, cable gland, nut & bolts with washer complete all as specified Note: (Excavation, earth work, sand cushioning, protection brick / tiles / block and pipe shall be measured and paid separately under appropriate items)
Supplying and fixing 3 (three) core circular/flat cable, 4 sqmm nominal cross sectional area multistranded copper conductor FRLS cable, 1100 Volts grade PVC insulated and PVC sheathed complete all as specified and directed.
Supplying and fixing 20 mm nominal bore dia, 3mm wall thickness PVC pipes of pressure rating 10 kgf/sqcm fixed with MS flat iron clamp of size 20 x 3mm at every 1.5 m length of pipe with nuts and bolts fixed to pole /walls, complete all as specified and as directed.
Supply and fixing flood light bracket made out of angle iron 50 mm x 50 mm x 5mm thick by cutting, welding and well finishing suitable size complete with drilling, hole, fixing with nuts bolts and washers including painting with two coats aluminium paint over a coat of red oxide primer complete all as specified and as directed.
Supply & fixing pole junction box (Loop IN and Loop OUT) of size 250mm x 190mm x 150mm, made out of 2.00 mm CRCA sheet CPRI approved factory made, weather, dust & vermin proof with front door and suitable locking arrangemennt including applying two coats of Powder coated paint over exposed external & internal sufaces with three phase and neutral copper busbar of size 20x3mm wrapped with PVC sleeves with maintained the colour code and provision of making holes with copper nuts, boolts & washers for cable connections mounted on hyydrographic insulators with nuts & bolts at both ends off busbar and one no SP 6 Amps 'C' series mounted on DIN rail including dismantling/takking out old unserviceable any type of busbar box from existing position all complete as specified and as directed.
Supply and install street light panel 3 phase with max load 6 KW having digital timer, with provision of MCB TPN 40 amps with contractor rating 32 Amp TP including necessary connection complete..
Material and labour point wiring for light point/ fan point, one light/fan/exhaust fan/ bell push point controlled by one, one way switch using 1.5 sqmm nominal cross sectional area multistranded copper conductor, PVC insulated unsheathed FRLS cables, 1100 volts grade single core in and including 20 mm dia or higher size rigid PVC concealed conduits and fittings of medium grade, including pressed steel terminal switch boxes, 3 mm thick bakelite sheet top cover (ISI Marked) fitted with chromium plated brass screws & washers and 1.5 sqmm nominal cross sectioanl area multistranded copper conductor FRLS PVC insulated unsheathed earth wire and connecting to earth dolly and brass screws, washers etc. complete all as specified and directed.
Supply and fixing exhaust fan 300mm sweep steel body with louvers 900 rpm 50 Hz 230 volts AC, fixed in existing opening of wall and point and making good distrubed surfaces complete all as specified.
Supply and fixing ceiling fan 1200 mm sweep, 230 volts AC 50 Hz, metal body with BEE 5 STAR rating comforming to IS-374-1979 including necessary connection with prewired 3 core flexible multistrand copper cable complete all as specified.
N K Construction
M/S. JAGDISH PRASAD AGARWALA
R K AGARWAL
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .