Tender Value
₹7.7 L
EMD Value
₹15,400
Closing Date
30 Oct 2020, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
AGE I R D KOCHI
AGE I R D KOCHI KAKKANAD KOCHI 682021
REPAIR TO CENTRAL AIR CONDITION PLANT INSTALLED AT MAIN LAB BUILDING NPOL KOCHI
2020_MES_383152_1
8029 E8
Open Tender
Electrical and Maintenance Works
Item Rate
330 days
AGE I R D KOCHI
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
AGE I R D KOCHI
₹15,400
5 Nov 2020
3 Oct 2020
5 Nov 2020
3 Oct 2020
30 Oct 2020
17 Oct 2020
3 Oct 2020 - 12 Oct 2020
60 days
Amount
M & L for isolation of the system, draining of existing compressor lub from compressor and filling new Synthetic oil , solest 120 incuding ne+E11:E16cessary transportation upto the site all as specified and directed by Engineer-in-charge.
M & L for recharging/topping up 134 a / R 22 gas as per requirement incuding necessary transportation upto the site all as specified and directed by Engineer-in-charge.
M & L for removal and replacement of existing suction pressure transducer all as specified and directed. Make : MCS or equivelant
M & L for removal and replacement of existing temperature transducer all as specified and directed. Make : Danfoss/Setra or equivelant
M & L for removing and replacing of drier core existing liquid line filter drier including all as specified and directed by Engineer-in-charge. Make : Sporlin/Alco/Danfoss or equivelant
M & L for removing and replacing of V belt (Each Set contains of 3 Nos)of AHU blower with new as per existing size including necessary alignment of pulley and shaft with tools required completeall as specified and directed. Make : Fenner / Dunlop/Delta or equivelant
M & L for removing and replacement of condensor water flow switch of existing model all as specified and directed
M & L for rewinding of chiller electric motor of cap 12.5 HP by dismantling and opening up of MOTOR AC, Three phase, 415 Volts, 50 Hz, Squirrel cage Induction motor, removing burnt out winding wires complete, cleaning stator and rotor assembly, rewinding the stator with same guage and type of insulation copper conductor winding wires and insulation sheets , applying insulating varnish over the complete winding , drying up by heating , assembling back the stator and rotor including replacement of terminal blocks and terminal bolts and nuts, both end bearings with same size / make complete incuding necessary transportation to & fro upto the site all as specified and as directed by Engineer-in-charge. (Note: Rate qouted sholud be deduction for credit of old burnt retrived copper wires from the motor)
All as per item No 08 here-in-before but M & L for rewinding of condenser electric motor of cap 15 HP
All as per item No 08 here-in-before but M & L for rewinding of cooling tower electric motor of cap 5 HP
M & L for Removal of existing pressure gauge along with siphon and cock and replacing with new dial type pressure gauge with range of 0 to 150 Psi, along withsiphon and cock complete incuding necessary transportation upto the site all as specified and as directed by Engineer-in-charge. Make : Waree/Wikai/Kains or equivelant
M & L for fabrication and fixing cooling tower motor saftey guard with 6 mm GI mesh including all welding work at site and removing old deteriorated gaurd complete all as specified and directed
De-canning of refrigerant form chiller No 01 rectification of external leak, replacemtn of angle cock, vacuumising of the system, refilling of refrigerant and commissioning complete all as specified and directed. Note: Additional refrigerant if required shall be measured and paid seperatley.
M & L for Isolation of Condenser water pump motor power removal of existing star delta contactor and replacing with new 3TF34 , 32 Amps 3pole, 440V, 2NC NO and 230V coil contactor complete including necessary transportation upto the site all as specified and as directed. Make L&T/Seimens/Schneider or equivelant
All as per item No 09 above but of Chiller water pump motor contactor 3TF30 , 20 Amps
M & L for Isolation of Power removal of existing single phase preventer, supply and replace with VSPD1 single phase preventer 440 V. complete incuding necessary transportation upto the site all as specified and as directed by Engineer-in-charge. Make : Minilec/leader/seimens or equivelant
AR Traders
National Creations
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart shows the information on this page on a best-effort basis and does not guarantee that it is accurate, complete or current. Check it against the buyer's official notice and documents before you act on it; the official record prevails. TenderKart is not liable for any loss or claim arising from the use of this information. If you notice any error or omission, please let us know at .