Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.9 LAccepted-AOC 0 0 BASANT AVENUE PHASE II PUNJAB GURDASPUR PUNJAB 143505 | GURDASPUR | PUNJAB | 143505 | L1 | Accepted-AOC Being L1 | |
| 2 | L2₹20.0 L+₹56,820 (2.93%)Rejected-Finance JANAKI NIVAS BEHIND CHOVVA TEMPLE CHOVVA PO KANNUR KERALA 670006 | KANNUR | KANNUR | KERALA | 670006 | L2 | Rejected-Finance Not being L1 |
Tender Value
₹20 L
EMD Value
₹40,000
Closing Date
23 Nov 2024, 6:00 pmClosed
GE Army Trivandrum
Office of Garrison Engineer Army, Thirumala Post, Trivandrum- 695006
MAINT AND REPAIR OF EXTERNAL WATER SUPPLY PIPE LINES, PERIODIC CLEANING AND DESCALING OF SHALLOW WELLS, BOREWELLS, PVC/RCC OVERHEAD TANKS, UG SUMP, MAINT AND REPAIR TO PUMP SETS AND CONNECTED WORKS AT KANNUR AND CALICUT AREA UNDER GE (ARMY) TRIVADRUM
2024_MES_680659_1
8234/E8
Open Tender
Civil Works
Item Rate
180 days
Kannur and Calicut
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
GE Army Trivandrum
₹40,000
Yes
4 Jan 2025
22 Oct 2024
30 Nov 2024
22 Oct 2024
23 Nov 2024
5 Nov 2024
22 Oct 2024 - 29 Oct 2024
Amount
Excavating in trenches in soft/ loose soil, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
Excavating in trenches in soft/ disintegrated rock, not exceeding 1.5 m wide and not exceeding 1.5 m in depth; for foundation, etc. or for shafts, wells, cesspits, manholes, pier holes, etc. not exceeding 10 sq m on plan and not exceeding 1.5 m in depth and getting out complete all as specified and directed.
Returning and filling in, including spreading, leveling, watering and well ramming in layers not exceeding 25 cm thick with soil obtained from excavation complete all as specified and directed.
Removing excavated materials, soil to a distance exceeding 100 m but not exceeding 150 m depositing where directed at a level 1.5 m above starting point complete all as specified and directed.
Taking up or down 20 mm bore steel/ UPVC/ PVC water tubing and connections, for replacement complete all as specified and directed.
All as per SI item No. 5.00 here-in-before, but 25 mm bore complete all as specified and directed.
All as per SI item No. 5.00 here-in-before, but 40 mm bore complete all as specified and directed.
All as per SI item No. 5.00 here-in-before, but 50 mm bore complete all as specified and directed.
All as per SI item No. 5.00 here-in-before, but 75/ 80 mm bore complete all as specified and directed.
All as per SI item No. 5.00 here-in-before, but 100 mm bore complete all as specified and directed.
Refixing old 20 mm bore steel/ UPVC/ PVC water tubing with new connections, fittings in new or old positions (Walls, ceiling, floors, etc.) including cleaning complete all as specified and directed.
All as per SI item No. 11.00 here-in-before, but 25 mm bore complete all as specified and directed.
All as per SI item No. 11.00 here-in-before, but 40 mm bore complete all as specified and directed.
All as per SI item No. 11.00 here-in-before, but 50 mm bore complete all as specified and directed.
All as per SI item No. 11.00 here-in-before, but 75/ 80 mm bore complete all as specified and directed.
All as per SI item No. 11.00 here-in-before, but 100 mm bore complete all as specified and directed.
Supplying, laying and jointing 20 mm bore Unplasticised PVC pipes of pressure rating 10 kgf/cm2 including all necessary pipe fittings fixed complete to walls, ceilings or in floors etc., complete all as specified and directed.
All as per SI item No. 17.00 here-in-before, but 25 mm bore complete all as specified and directed.
All as per SI item No. 17.00 here-in-before, but 40 mm bore complete all as specified and directed.
All as per SI item No. 17.00 here-in-before, but 50 mm bore complete all as specified and directed.
All as per SI item No. 17.00 here-in-before, but 75/ 80 mm bore complete all as specified and directed.
All as per SI item No. 17.00 here-in-before, but 100 mm bore complete all as specified and directed.
Supply only 25 mm bore UPVC gate valve/ ball valve, with handle including taking down old unserviceable valve complete all as specified and directed.
All as per SI item No. 23.00 here-in-before, but 40 mm bore complete all as specified and directed.
All as per SI item No. 23.00 here-in-before, but 50 mm bore complete all as specified and directed.
Supply only 25 mm bore UPVC union, plane type, including taking down old unserviceable union complete all as specified and directed.
All as per SI item No. 26.00 here-in-before, but 40 mm bore complete all as specified and directed.
All as per SI item No. 26.00 here-in-before, but 50 mm bore complete all as specified and directed.
Supply only 25 mm bore UPVC socket, plane type, including taking down old unserviceable socket complete all as specified and directed.
All as per SI item No. 29.00 here-in-before, but 40 mm bore complete all as specified and directed.
All as per SI item No. 29.00 here-in-before, but 50 mm bore complete all as specified and directed.
Cutting in Road/ PCC/ chequered tile/ hard surface for laying pipes of any size and depth and making good surface as per existing complete all as specified and directed. Note:- PCC will be measured and paid separately.
M&L for PCC 1:2:4, Type B2 (using 40mm graded stone aggregate) as in foundation, filling mass concrete complete all as specified and directed.
Checking and rectifying the leakage/ breakage/ loose connection of pipe line any type (CI/ UPVC/ PVC/ GI/ CPVC/ DI) and size, which is in trench/ wall and find out defect. Taking out unserviceable parts from trench/ wall such as union/ ball valve/ socket/ male and female adaptor/ elbow/ tee/ bend/ lead joints/ nuts, bolts/ small length of pipe etc. and replacing the defective parts including minor repairs to pipes connection/ loose connection/ necessary cleaning the repair pipes where provided and testing complete all as specified and directed. Notes:- i). 01 plumber with 01 helper will be reported to the complaint cell every day morning 09:00 hrs. ii). Every complaint noted by the contractor in their register and end of the every month same should be submitted to office and get the signature for Engineer-in-charge. iii). Spares of pipe fittings shall be measured and paid separately under Sl item No. 23 to 31. iv). The T&P/ man power/ solvent/ shellac/ Teflon tape/ excavation (not more than 01 Cum) will be provided by the contractor and the cost deemed to be included in the quoted rate.
M&L for bailing out water from the open wells/ shallow wells having dia metre 40 feet and depth 40 feet located at well No. 1, 2 and 3 at Jubily park, Kannur by using diesel pump set of suitable capacity and remove the sludge deposited in the bottom of well by using suitable method as directed by the Engineer-in-charge and remove to a distance not exceeding 50 mtr away from the well. Cleaning the well bottom and steining with potable water with bleaching powder thoroughly, remove roots, small trees/ bushes on the inside wall of the well etc cleaning the iron grills over the well and ensure potability of water complete all as specified and directed. Note:- Any tools/ plants/ man power etc. required for the work will be arranged by the contractor without any extra cost and same is deemed to be included in the quoted rate.
All as per SI item No. 35.00 here-in-before, but well of dia 15 feet and depth 40 feet located at INP pump house, Kannur complete all as specified and directed.
All as per SI item No. 35.00 here-in-before, but well of dia 16 feet and depth 60 feet located at Payyambalam area, Kannur complete all as specified and directed.
All as per SI item No. 35.00 here-in-before, but well of dia 16 feet and depth 30 feet located at Butcherry area, Kannur complete all as specified and directed.
All as per SI item No. 35.00 here-in-before, but well of dia 11 feet and depth 40 feet located at WL line family Qtrs area and fort road, Kannur complete all as specified and directed.
M&L for taking out the column pipes, submersible cable, submersible pump set of capacity up to 5 HP from bore well having dia metre 100 to 150 mm and depth 100 mtr located at INP pump house. Bailing out water from the bore well by using high pressure pump set of suitable capacity and washout the mud deposited in the bottom of bore well with entire satisfaction of the Engineer-in-charge. Washing out the bore well with fresh water again and again till when the clear water is obtained. All deposits which are pumped out will be remove to a distance not exceeding 50 mtr away from the bore well and pump house area, and ensure potability of water after cleaning, including lowering the same i.e pump set, column pipe and cable, testing for proper working after refixing the pumping system of bore well complete all as specified and directed. Note:- Any tools/ plants/ man power etc. required for the work will be arranged by the contractor without any extra cost to the department.
All as per SI item No. 40.00 here-in-before, but for the pump set capacity of 10 HP complete all as specified and directed.
Collecting the water sample in the sterilized container from the sump/ OH tank in presence of AGE and transport to National/ State govt. authorized laboratory such as PHE/ NTH or any Govt approved agencies and carrying out the physical/ chemical/ biological analysis and submitting the detailed report as per standard parameter in duplicate to AGE office complete all as specified and directed. Note:- i). Testing will be carried out with the intervals of 2 months, 3 months as directed. ii). All test report will be submitted to AGE Cannanore and first test will be completed within the two, three months from the date of acceptance of tender and second will be submitted within completion of CA.
M&L for cleaning of overhead service tank RCC/ PVC of capacity upto 1000 ltrs by draining out water and removing all internal dirt and scale/ mud by washing. Cleaning the internal surface of the service tank using wire brushes and or any other means to remove dirt and scale to make it free from all deposits. Washing the reservoir thoroughly and removing dirty water from the tank, then clean with fresh water again and writing date of the cleaning on external wall with white enamel paint with black back ground. Repair to internal surfaces by plastering and providing fillers in cracks to prevent seepage/ leakage of water complete all as specified and directed. Note for item No. 43 and 44:- i). The work of cleaning and disinfection will be carried out by expert in the field of the work. The work is to be carried out in such a way that water supply will not be disturbed. ii). Scaffolding/ ladder or any other suitable method shall be provided by the contractor and rate deemed to be included in the quoted rate. iii) Contractor shall make all necessary safety measures for labours at site.
All as per SI item No. 43.00 here-in-before, but for the tank capacity 4,500 ltrs complete all as specified and directed.
M&L for cleaning of RCC overhead reservoir of capacity 22,500 ltrs with 18/ 20 mtr staging by draining out water and removing all internal dirt and scale/ mud by washing. Cleaning the internal surface of the service tank using wire brushes and or any other means to remove dirt and scale to make it free from all deposits. Washing the reservoir thoroughly and removing dirty water from the tank, then clean with fresh water again and writing date of the cleaning on external wall with white enamel paint with black back ground. Repair to internal surfaces by plastering and providing fillers in cracks to prevent seepage/ leakage of water complete all as specified and directed. Note for item No. 45 to 48:- i). The work of cleaning and disinfection will be carried out by expert in the field of the work. The work is to be carried out in such a way that water supply will not be disturbed. ii). Scaffolding/ ladder or any other suitable method shall be provided by the contractor and rate deemed to be included in the quoted rate. iii) Contractor shall make all necessary safety measures for labours at site.
All as per SI item No. 45.00 here-in-before, but for RCC overhead reservoir of capacity 50,000 ltrs with 18/ 20 mtr staging complete all as specified and directed.
All as per SI item No. 45.00 here-in-before, but for RCC overhead reservoir of capacity 55,000 ltrs with 18/ 20 mtr staging complete all as specified and directed.
All as per SI item No. 45.00 here-in-before, but RCC overhead reservoir of capacity 45,000 ltrs with 18/ 20 mtr staging complete all as specified and directed.
S&F 20 mm bore ball valve high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball screwed for iron pipe (Minimum weight 20 mm - 210 gms), including taking down old unserviceable valve complete all as specified and directed.
All as per SI item No. 49.00 here-in-before, but 25 mm bore ball valve ((Minimum weight 25mm - 455gm), including taking down old unserviceable valve complete all as specified and directed.
M&L for cleaning of underground reservoir of capacity 22,500 ltrs by draining out water and removing entire internal sludge by washing. Cleaning the bottom and internal wall surfaces of the reservoir using wire brushes and other scraping tools to remove dirt and scale to make it free from deposits and removing dirty water from the tank to make it clean with fresh water again and write date of cleaning on external wall with white enamel paint with black back ground. Repair to internal surfaces by plastering and providing fillers at cracks to prevent any seepage/ leakage of water complete all as specified and directed. Note for item No. 51 to 56:- i). The work of cleaning and disinfection will be carried out by expert in the field of the work. The work is to be carried out in such a way that water supply will not be disturbed. ii). Scaffolding/ ladder or any other suitable method shall be provided by the contractor and rate deemed to be included in the quoted rate. iii) Contractor shall make all necessary safety measures for labours at site.
All as per SI item No. 51.00 here-in-before, but for the capacity of 55,000 ltrs complete all as specified and directed.
All as per SI item No. 51.00 here-in-before, but for the capacity of 45,000 ltrs complete all as specified and directed.
All as per SI item No. 51.00 here-in-before, but for the capacity of 90,000 ltrs complete all as specified and directed.
All as per SI item No. 51.00 here-in-before, but for the capacity of 1,00,000 ltrs complete all as specified and directed.
All as per SI item No. 51.00 here-in-before, but for the capacity of 1,80,000 ltrs complete all as specified and directed.
Taking out defective submersible pump set of any capacity from open well/ UG sump/ bore well of any depth and transport to trade workshop for repair/ rewinding and transport back to original place complete all as specified and directed. Note:- All new spare parts and winding of the motor will be measured and paid separately. Tools, man power, transportation are to be deemed to be included in the quoted rate.
M&L for rewinding the submersible 3 phase motor up to 3 HP capacity with super enamelled insulated copper winding wire as per existing gauge as approved and warnishing, testing after repair, including taking out old unserviceable/ burnt winding complete all as specified and directed. Note: The scope of work under this item shall be carried out in authorised work shop as approved by Engineer-in-charge. Note:- All minor parts like nuts, bolts, washers, water tape are deemed to be included in the quoted rate.
All as per SI item No. 58.00 here-in-before, but for the 3 phase motor 5 HP to 7.5 HP capacity complete all as specified and directed.
All as per SI item No. 58.00 here-in-before, but for the 3 phase motor 10 HP capacity complete all as specified and directed.
All as per SI item No. 58.00 here-in-before, but for the 3 phase motor 15 HP capacity complete all as specified and directed.
M&L for painting submersible pump set with motor of capacity upto 5 HP and remove all sludge/ rusted parts deposited on the outer surface of the pump set and motor, painting with two coats of synthetic enamel paint over a coat red oxide zinc chrome primer complete all as specified and directed.
All as per SI item No. 62.00 here-in-before, but for the pump set with motor of capacity upto 10/ 15 HP complete all as specified and directed.
S&F new impeller of existing capacity suitable for submersible pump set with motor of capacity up to 3 HP and taking out unserviceable/ defective CI impeller complete all as specified and directed. Note:- All minor parts like nuts, bolts, washers, water tape are deemed to be included in the quoted rate.
All as per SI item No. 64.00 here-in-before, but for the pump set with motor of capacity 5 HP to 7.5 HP complete all as specified and directed.
All as per SI item No. 64.00 here-in-before, but for the pump set with motor of capacity 10/ 15 HP complete all as specified and directed.
S&F stainless steel shaft with shaft key for capacity up to 5 HP submersible pump set including taking down old unserviceable one complete all as specified and directed.
S&F stainless steel shaft with shaft key for capacity up to 10 HP submersible pump set including taking down old unserviceable one complete all as specified and directed.
S&F stainless steel shaft with shaft key for capacity up to 15 HP submersible pump set including taking down old unserviceable one complete all as specified and directed.
Labour for refixing/ lowering of submersible pump set of any capacity in the open well/ UG sump/ borewell of any depth complete all as specified and directed. Note:- All spare parts and winding of the motor will be measured and paid separately. Tools and man power are deemed to be included in the quoted rate.
S&F PVC insulated and PVC sheathed copper conductor cable flat type, multistranded of size 6 sqmm 3 core, including taking down old unserviceable three core copper cable complete all as specified and directed.
S&F PVC insulated and PVC sheathed copper conductor cable flat type, multistranded of size 4 sqmm 3 core, including taking down old unserviceable three core copper cable complete all as specified and directed.
Disconnecting, isolating, electrically unserviceable star delta/ DOL starter 3 phase 440 volts any capacity any make and type and taking down from wall/ panel board keeping aside for disposal complete all as specified and directed.
S&F DOL starter with wideband coil (model MU-G6, DOL) 3 phase 440 volts, Relay range 14 Amps complete all as specified and directed.
S&F electronic star delta submersible pump controllers with wideband coil (model MU-G15, FASD) 3 phase with relay range 14 Amps complete, including connecting with pump set cable and testing of satisfactory running complete all as specified and directed.
S&F electronic star delta submersible pump controllers with wideband coil (model MU-G20, FASD) 3 phase with relay range 22 Amps complete, including connecting with pump set cable and testing of satisfactory running complete all as specified and directed.
S&F mild steel framed work such as grills, gratings, ladder (OH tank 18 mtr high at park pump house and INP pump house) etc, with ends of bars shouldered and/ or riveted, or forged into spikes; framed guard bars, barred iron doors, ladders, framed balusters, walk ways, railings, frame work of water tanks and similar work conforming to Fe.410.Gde-E-250 including applying two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer, including dismantling wrought iron or mild steel framed work of any description complete all as specified and directed. Note:- Scaffolding/ ladder or any other safety equipments, T&P, welding materials will be provided by the contractor and cost deemed to be included in the quoted rate.
Dismantling monoblock/ centrifugal pump set and motor of capacity 3 HP from the base and transporting to the trade work shop for carrying out rewinding and overhauling of motor and pump set assembly including taking out defective spare parts. M&L for rewinding the same with new super enamelled insulated copper winding wire as per existing gauge as approved by Engineer-in-charge and warnishing, testing after repair work. After winding, assembling the complete motor assembly, checking and starting and testing complete pump set for its performance satisfactory result complete all as specified and directed. Note:- i) The scope of work under this item shall be carried out in authorised work shop as approved by Engineer-in-charge. ii) All new spares/ components will be measured and paid separately under Sl item No. 79 to 82. iii) Replacement of gland packing, gun metal bush bearing and water seal, applying greasing etc. bolts/ nuts/ washers are deemed to be included in the quoted rate.
Supply glang packing of any size suitable to monoblock/ centrifugal pump set and motor of capacity 3 HP complete all as specified and directed.
Supply CI impeller for monoblock/ centrifugal pump upto 3 HP complete all as specified and directed.
Supply stainless steel shaft with shaftkey for monoblock/ centrifugal pump capacity upto 3 HP complete all as specified and directed.
Sypply coupling set for monoblock/ centrifugal pump capacity upto 3 HP complete all as specified and directed.
Assembling/ coupling of monoblock/ centrifugal pump and motor of capacity upto 3 HP, carrying out complete transporting to pump house including installation, connection of electrical and water line and testing on load after proper alignment over the foundation to the entire satisfaction of Engineer-in-charge complete all as specified and directed.
M&L for painting monoblock/ centrifugal pump set with motor of capacity upto 3 HP and remove all sludge/ rusted parts deposited on the outer surface of the pump set and motor, painting with two coats of synthetic enamel paint over a coat red oxide zinc chrome primer complete all as specified and directed.
Dismantling monoblock/ centrifugal pump set and motor of capacity 5 HP from the base and transporting to the trade work shop for carrying out rewinding and overhauling of motor and pump set assembly including taking out defective spare parts. M&L for rewinding the same with new super enamelled insulated copper winding wire as per existing gauge as approved by Engineer-in-charge and warnishing, testing after repair work. After winding, assembling the complete motor assembly, checking and starting and testing complete pump set for its performance satisfactory result complete all as specified and directed. Note:- i) The scope of work under this item shall be carried out in authorised work shop as approved by Engineer-in-charge. ii) All new spares/ components will be measured and paid separately under Sl item No. 86 to 89. iii) Replacement of gland packing, gun metal bush bearing and water seal, applying greasing etc. bolts/ nuts/ washers are deemed to be included in the quoted rate.
Supply glang packing of any size monoblock/ centrifugal pump set and motor of capacity 5 HP complete all as specified and directed.
Supply CI impeller for monoblock/ centrifugal pump upto 5 HP complete all as specified and directed.
Supply stainless steel shaft with shaftkey for monoblock/ centrifugal pump capacity upto 5 HP complete all as specified and directed.
Sypply coupling set for monoblock/ centrifugal pump capacity upto 5 HP complete all as specified and directed.
Assebmling/ coupling of monoblock/ centrifugal pump and motor of capacity upto 5 HP, carrying out complete transporting to pump house including installation, connection of electrical and water line and testing on load after proper alignment over the foundation to the entire satisfaction of Engineer-in-charge complete all as specified and directed.
M&L for painting monoblock/ centrifugal pump set with motor of capacity upto 5 HP and remove all sludge/ rusted parts deposited on the outer surface of the pump set and motor, painting with two coats of synthetic enamel paint over a coat red oxide zinc chrome primer complete all as specified and directed.
Supplying, fixing, testing and commissioning new LT starter panel with LT pillar box, outdoor cubical type, dust, weather and vermin proof with front and back openable made out of 2.50 mm thick CRCA sheet made with 50x50x6 mm angle iron frame, bottom floor mounted, compartment double door with neoprene gasket and locking arrangement of suitable size, panel box will be epoxy powder coated on all sides/ surface internally and externally with earth terminals on two sides complete all as specified and directed. with and inclusive of following items:-
S&F in replacement of relay for starter MK1, 9-14 Amps capacity, 440 volts, 50 Hz complete all as specified and directed.
S&F in replacement of relay for starter MK1, 13-22 Amps capacity, 440 volts, 50 Hz complete all as specified and directed.
S&F in replacement of MK1 standard operating coil, capacity 440 volts, 50 Hz complete all as specified and directed.
S&F in replacement of MK1 contactor, capacity 440 volts, 50 Hz complete all as specified and directed.
M&L for Earthing complete with galvanised steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground vertically to a depth not less than 2.25 metre below ground level with top edge of earth plate at a depth of not less than 1.5 metre below normal ground level, connected to galvanised earth lead of GI strip of size 32x6mm dia by means of GI bolts, nuts, check nuts and washers of the earth and thimbles and other end of the earth strip connected to earthing test point and protected by galvanised iron pipe light grade 40mm dia from earth plate to Panel/DBs and water pipe 20mm dia GI medium grade raised up to a level of 50cm above ground level with plug at top, earthing pit in PCC (1:3:6) type C-1 RCC pre-cast (1:2:4 type B-1) cover slab of 50 mm thick using 8.00mm dia CTD bars reinforcement both ways at 140 mm centre to centre with handle, 20 mm dia GI pipe medium grade for watering pipe, wire mesh, funnel and providing charcoal or coke and salt in alternative layers of 15 cm including necessary earth work in any type of soil, returning, refilling and removing of surplus soil to a distance not exceeding 50 mtr testing complete all as shown in electrical plate No-3 of MES Schedule Part-I of SSR-2009 complete all as specified and directed, including taking down existing unserviceable earthing complete all as specified and directed.
Cutting grass, vegetation all around the well and pump house area with bush cutter machine (approximate area of pump house and well is 250 Sqm), including trimming of tree branches falling to the well area and removing all debris/ rubbish to a distance not exceeding 50 mtr complete all as specified and directed.
M&L for painting monoblock/ centrifugal pump set with motor of capacity upto 10 HP and remove all sludge/ rusted parts deposited on the outer surface of the pump set and motor, painting with two coats of synthetic enamel paint over a coat red oxide zinc chrome primer complete all as specified and directed.
M&L for valve pit chamber of size 120x120x90 cm internal dimension, in brick/ stone construction including excavation and earth work in any type of soil, returning, filling, disposal of surplus soil to a distance not exceeding 50 mtr and depositing where directed, PCC foundation of the mix (1:2:4), type B2, brick masonry including plastering 12 mm thick in cement mortar 1:4, internally finished even and fair and flush pointing externally as the work proceeds in same mortar and suitable size angle frame with mild steel angle iron 40x40x6 mm, MS sheet cover 3.15 mm thick with handle and locking arrangement and painting all steel surfaces with two coats of synthetic enamel paint over a coat of red oxide zinc chrome primer and painting all MS embedded in PCC with two coats of black bituminous paint as approved, including demolition of existing old valve chamber complete all as specified and directed.
S&F pump house control and starter panel board LT, double door type front and back openable, CPRI approved outdoor type, padestal mounted, overall size not less than 1000x900x450 mm, having independent compartment for bus bar, incoming feeder and each outgoing feeders, dust and vermin proof & locking facilities, factory made, fabricated out of 3.15 mmthick CRCA sheet including Angle iron base frame as required as per above panel, total leg height is 600 mm and leg length inside PCC is 150 mm and made out of ISA 5050, 50x50x6 mm thick angle iron duly painted with two coats of synthetic enamel spray painted over a coat of metalic primer, suitable for 3 phase 415 volts 50 Hz, AC supply, bus bar chamber with copper bus bar of 200 Amps rating for 3 phase and neutral 4 wire system duly insulated with heat shrinkable type sleeves as per colour code, supported on epoxy insulators - 01 set including necessary copper cables of suitable size for MCCBs/MCBs/change over switch/ inter connections, common earth bus bar of GI strip 25x5 mm at bottom with panel board at two earth terminals, cable glands with independent plates at bottom for each outgoing and incoming cables in cable alley panel board and painted with powder coating in grey colour and provision for the following incoming and outgoing accessories, including taking down old unserviceable LT panel board complete all as specified and directed as under:-
Outgoing:- a) MCCB 4 pole, 63 Amp, 415 Volts, 25 KA with thermal and magnetic, microprocessor release adjustable between 40% to 100% against overload setting - 03 Nos b) MCB SPN 40 Amp, 'C' curve, 415 Volts, 10 KA - 03 Nos c) Inbuilt star delta submersible pump controllers FASD type, 10 HP capacity, 3 phase, 415 Volts, 50 Hz - 02 Nos
Note:- (i) Platform for the panel with PCC 1:4:8 type D-2 with 40mm graded crushed stone, 15 cm thick in foundation, brick work in CM 1:6 with sub class 'B', old size bricks, rendering 15mm in CM 1:6 on exposed surfaces and 100mm thick PCC padding 1:3:6, type C-1 using 20mm graded crushed stone aggregate on top and grouting bolts etc for panel. The platform shall be such that it is of a height 45cm above the nearest road level. Rate for earth work, PCC, brick work, rendering deemed to be included in the quoted rate. (ii) All out going feeders shall be connected by cable through suitable size gland plate / glands.
T.P.SUNIL KUMAR (BID ID -3167877)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .