Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹24.3 LAccepted-AOC | ₹24.3 L | L1 | Accepted-AOC L1 |
| 2 | L2₹24.5 L+₹24,768.53 (1.02%)Rejected-AOC | ₹24.5 L+₹24,768.53 (1.02%) | L2 | Rejected-AOC L2 |
| 3 | L2₹24.5 L+₹24,768.53 (1.02%)Rejected-AOC NA | NA | NA | 121004 | ₹24.5 L+₹24,768.53 (1.02%) | L2 | Rejected-AOC L2 |
Tender Value
₹24.8 L
EMD Value
₹50,000
Closing Date
22 May 2026, 5:00 pmClosed
EXECUTIVE ENGINEER PMU ERNAKUAM
Executive Engineer PMU Ernakulam
RECONDUCTORING WITH COVERED CONDUCTOR FROM KAIRALI JN TO ANCHAMPARUTHI DTR UNDER ELECTRICAL SECTION, CHENNAMANGALAM
2026_KSEB_849572_1
EP- 13/2026-27/PMU - EKM/ dt. 07-05-2026
Open Tender
Electrical Works
Percentage
90 days
chendamangalam
Please refer tender documents
4 documents required · 4 mandatory
₹5,900
Yes
₹50,000
PMU EKM
21 Aug 2026
7 May 2026
26 May 2026
7 May 2026
22 May 2026
8 May 2026
14 May 2026
This is a percentage-rate BOQ. The schedule below shows estimated quantities and rates. Bidders quote a single percentage above or below the total estimated cost.
| Sl No | Description | Qty | Unit | Est. Rate | Est. Amount |
|---|---|---|---|---|---|
| 1 | Stringing of one km 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalant (3 conductors) after fitting insulators, binding conductors to pin insulators using suitable tie and anchoring with wedge type anchoring clamps including cutting and removing tree branches wherever necessary excluding cut point works. | 6,200 | m | 43.49 | ₹2,69,638 |
| 2 | Providing bridging at Cut points for 3 PH 11kV line with XLPE Insulated ACSR Raccoon or equivalent (1 conductors) using IPC and respective conductors | 500 | E | 173.36 | ₹86,680 |
| 3 | Fitting one No. Section fuse on LT line with dropping cables, crimping sockets, connecting with bolt & nut etc. | 15 | No | 240.45 | ₹3,606.75 |
| 4 | Dismantling one section fuse from structure and bringing back to section store. | 15 | No | 192.36 | ₹2,885.4 |
| 5 | Insertion of one HT A type pole in existing OH line including digging & backfilling pit in ordinary soil, fitting cross arm, insulators, binding etc., drawing sufficient length of GI earth leads to the ground for earthing (excluding provision of earthing). | 8 | No | 4,302.05 | ₹34,416.4 |
| 6 | Labour charges for loading HT A type pole from the stacking place and unloading the same at work site (transportation by any vehicle). | 77 | No | 906.41 | ₹69,793.57 |
| 7 | Renewal of existing damaged/old 11kV PSC/RCC Pole with new A type pole in place including excavation, erection of new pole, backfilling pit and refitting of all items etc. and conveyance of all materials except pole. | 59 | No | 6,231.95 | ₹3,67,685.05 |
| 8 | Renewal of existing damaged/old 11kV PSC/RCC DP with new A type DP in place including excavation, erection of new pole, backfilling pit and refitting of all items etc. and conveyance of all materials except poles. | 5 | No | 14,984.5 | ₹74,922.5 |
| 9 | Additional rate for refitting/redoing one Disc set while renewing any type of 11kV cut pole. | 300 | No | 722.41 | ₹2,16,723 |
| 10 | Additional rate for reinstalling LT line on the renewed 11kV pole having both HT and LT (HT/LT) lines. | 15 | No | 745.41 | ₹11,181.15 |
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.66 MB
EP13Tenderdoc.pdf
Tender Documents • 1.73 MB
BOQ_1435551.xls
BOQ • 0.37 MB
DatecorrigendumChennamangalam.pdf
PDF • 0.60 MB
Datecorrigendum.pdf
PDF • 0.51 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .