Loading…
Loading…
| # | Company | Status |
|---|---|---|
| 1 | Admitted-Finance VILL UPPER NATHANPUR PO NEHRUGRAM NR AMBIWALA GURUDWARA DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | Admitted-Finance |
| 2 | Admitted-Finance COURT ROAD UTTARKASHI | Admitted-Finance |
Tender Value
₹97 L
EMD Value
₹1.9 L
Closing Date
5 May 2022, 1:00 pmClosed
Superintending Engineer, EDC (Urban),Dehradun
Office of the Superintending Engineer, EDC (Urban),Dehradun
Shifting of HT/LT overhead line from Kargi Chawk to Kali Mandir and Kali Mandir to Lalpul Patel Nagar due to road widening on turnkey basis against e tender no. 01/EDC(U)/2022-23
2022_UPCL4_42742_2
01/EDC(U)2023-24
Open Tender
Electrical Works
Item Wise
90 days
as per tender specification
As tender specification
6 documents required · 6 mandatory
₹5,900
Superintending Engineer, EDC (Urban),Dehradun
₹1.9 L
7 May 2022
13 Apr 2022
5 May 2022
14 Apr 2022
5 May 2022
15 Apr 2022
MATERIAL
Stay wire 7/10 swg
Stay set 16x1800 mm
ST Pole 8.5 mtr long SP-23(Bottom portion hot dip Galavanized)
ST Pole 11 mtr long SP-55 (Bottom portion hot dip Galavanized)
Stay set 20x1800 mm
Stay wire 7/8 swg
MS Angle 75x75x8 mm. (4 mtr. on DP & 2.2 mtr on SP )
MS Channel 100X50 mm
MS angle 65x65x6 mm.
LT XLPE Cable 1x240sq.mm
LT XLPE Cable 1x120sq.mm
GI wire 8 SWG
GI wire 6 SWG
Earthwire 7/16 SWG ( 1000 m @ 110 Kg./Km. + 3% C&W)
Earthing rod 20x2500mm
Disc fitting for w/r 45 kn
Disc fitting for Dog / Racoon
ACSR Rabbit conductor for street light
ACSR Dog conductor ( 3X300+3X3100+4X400 + 3% Sag)
ACSR weasel conductor for jumpering on double poles/Tranformers
9 KV 5 KA Lightening Arrestor
MS Channel 125x65x6 mm
33 KV Pin insulator with pin (polymer)
11 KV Pin insulator Polymer type
11 KV G/O Switch
11 KV Disc Insulator Polymer type
LT AB Cable 3X120+1x95+1x16 sq mm
33 KV Disc Insulator Polymer Type
De-Centralized Material
Al crimping lug of size 70 sq.mm
Al crimping lug of size 120sq.mm
Al crimping lug of size 240sq.mm
Barbed Wire
Bracing clamp (made of MS flat 65x6 mm) with nut & bolt
Danger Board with clamps, nut & bolt
Earth wire clamp (made of MS flat 50x6 mm)
Holding clamp for LT Fuse set of MS flat 50x6 mm.
F clamp (made of MS flat 50x6 mm) for 11 KV pin insulator
F clamp (made of MS flat 75x8 mm) for 33 KV pin insulator
LT Clamp(made of MS flat 50x6 mm) for SP-23 with nut and bolt
LT Clamp(made of MS flat 50x6 mm) for SP-55 with nut and bolt
LT Shakle insulator (100x115 mm)with nut and bolt
PG Clamp for Dog to Dog Conductor 3/4 bolted
PP/fixing clamp (made of MS flat 65x6 mm) for SP-23 with nut and bolt
PP & clamp(made of MS flat 50x6 mm) with nut & bolt
Distribution box 3-ph with holding clamp with n&b
Piercing connector 120/95
Piercing connector 95/25
Dead end clamp
Suspension type clamp
Stay clamp( made of MS flat 65x6) with nut & bolt SP-55
Stay insulator for 33 KV with all fitting
Stay insulator for 11 KV with all fitting
LABOUR CHARGES
Cartage of ST pole and PCC Poles from store centre to construction site with loading, unloading at both points
Other stock material
Head Load Cartage
Other stock material
Excavation of earth for pole pit of size 0.9x0.6x1/6 of full length of pole for erection of pole
Erection of following Single support pole in proper level and alignment alongwith fixing of all accessories, like top channel & clamps as per RESSPO construction Manual.
Erection of following Double support pole in proper level and alignment alongwith fixing of all accessories
ST Pole SP-55
Erection of following Four pole support in proper level and alignment alongwith fixing of all accessories.
SP-55 (11KV/33KV)
Grouting of pole in size 0.45x0.45x1/9 of the support in CC ratio 1:4:8 (1 cement : 4 graded stone 20mm nominal
Muffing of poles size 0.45 cm x 0.60 cm radious with cc 1:3:6 (1 cement : 3 coarse sand
Fabrication of M.S. Channel Angle iron after cutting in required sizes with drilling of holes upto good finish for top channel, bracing and special type bracket etc. as per RESSPO sehedule and local approved drawing.
Fixing of D-type bracket in LT line
Fixing of Extension bracket in 11 KV line
Fixing of Extension bracket in 33 KV line
Excavation of earth for Stay pit of size 0.6x0.6x1.2mtr in all type of soil including proper dressing
Fixing , tightening and nozzaling of Stay with pole and stay rod
11 KV line
33 KV line
Grouting of Stay in size 0.6x0.6x0.3 in CC ratio 1:4:8
Earthing of support with M.S. Earth rod of 2.5 meter long by hammaring of M.S. Rod 48 pole earthing + 38 L/A & Boby Earthing Of TF
Laying, Spreading, Stringing and sagging following conductor (3 ph 4 wire including earthwire as the extra wire)
Dog CONDUCTOR ( for 33 kV)
Dog CONDUCTOR ( for 11 kV)
Laying, Spreading, Stringing and sagging of LT line (3-ph, 5 Wire)
Dog CONDUCTOR (for LT)
Jumpering of distribution transformers and making proper connection with ACSR weasel conductor
Guarding of Line over (Telephone / Road / L.T. line crossing as per drawing with 6/8 SWG G.I. wire including fixing of guarding channel/ angle as per RESSPO manual. L.T./11KV /33KV
11KV Line.
33KV Line.
Mounting & Fixing of TPMO on double pole structures including making of connections complete work
Mounting & Fixing of Fuse sets on double pole structures including making of connections complete work
Mounting and Fixing of Lightning arrestor set (3 Nos.) on double pole
Painting of poles with angle and channel and all steel part
ST Pole SP-23
ST Pole SP-55
Dismantling of TPMO /fuse set on double pole structure.
Dismantling of existing LT/HT line. including disc fitting, Insulator, clamps, Nut & Bolts Single Pole
Dismantling of existing LT/HT line. including disc fitting, Insulator, clamps, Nut & Bolts Double Pole
Dismantling of existing LT/HT line. including disc fitting, Insulator, clamps, Nut & Bolts Four Pole
Dismantling of 33 KV Line WITH DOG CONDUCTOR
Dismantling of 11 KV Line WITH DOG CONDUCTOR
Dismantling of LT Line (including street light wire) WITH DOG CONDUCTOR
Dismantling of Transformers from double pole /plinth including opening of all connections, circuts & earthing strip etc.
Installation / mounting of new Tranformer on plinth pole structure On Double Pole
Providing and fixing of Danger Board and number plate
Dismentling of AB cable
laying of AB cable
Relaying of above dismentteled AB cable
Connecting of GI Plate eathing with Transformer/Panel with lap welding including bending or other required work etc. GI strip shall be laid down upto the neutral & T/F body seperately in one piece. Test result of earthing shall be provide by contarctor. Acceptable results shall be within 3 ohm.
DISMENTLING OF L.T. PVC CABLE 1X120CMM2
DISMENTLING OF L.T. PVC CABLE 1X240CMM2
Dismantelling and remounting of metring cubical after completion of erection work
Dismentling and Remounting of sectionlizer
Back carriage of following
ST POLE 23/ 55/METABLE /CHANNEL/ANGLE/SCRAP
CODUCTOR SCRAP
Laying and erection of L.T. PVC single lead Cable including crimping of lugs of size 1x120/240
Making of section pole for existing LT/HT line complete in all respect.
SHIV ELECTRICALS
stage.html
html • 0.03 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .