| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹7.4 LAccepted-AOC 26 2579 THEVARA PO KOCHI ERNAKULAM KERALA 682013 | KOCHI | ERNAKULAM | KERALA | 682013 | L1 | Accepted-AOC BEING LOWEST TENDERER | |
| 2 | L2₹13.0 L+₹5.2 L (67.7%)Rejected-Finance DOOR NO 68 2963 E3 MANDAKKARA ROAD AYYAPPANKAVU ERNAKULAM KERALA 682 018 | ERNAKULAM | ERNAKULAM | KERALA | 682018 | L2 | Rejected-Finance NOT BEING LOWEST TENDERER | |
| 3 | L3₹13.9 L+₹6.2 L (79.5%)Rejected-Finance KURUPPAMPARAMBIL PERUMPADAPPU PALLURURHY P O ERNAKULAM KERALA 682006 | ERNAKULAM | KERALA | 682006 | L3 | Rejected-Finance NOT BEING LOWEST TENDERER |
Tender Value
₹13 L
EMD Value
₹26,000
Closing Date
30 Sept 2023, 6:00 pmClosed
GE FORT KOCHI
GARRISON ENGINEER MILITARY ENGINEER SERVICES GE FORT KOCHI -682 001
REPAIR/MAINT OF COOLING APPLIANCES LIKE SPLIT ACS, WATER COOLERS, DEEP FREEZER ETC AND COMPREHENSIVE MAINT OF APFC PANELS INCLUDING REPAIR/MAINT AND CONNECTED WORKS AT INS DRONACHARYA,NPOL AND SMA RAMESWARAM UNDER GE FORT KOCHI
2023_MES_606091_2
8936/E8/GE_FORT_KOCHI
Open Tender
Electrical and Maintenance Works
Item Rate
FORT KOCHI
AS PER TENDER DOCUMENTS
7 documents required · 7 mandatory
₹500
GE FORT KOCHI
₹26,000
Yes
4 Nov 2023
11 Sept 2023
2 Oct 2023
11 Sept 2023
30 Sept 2023
16 Sept 2023
Amount
AIR CONDITIONING:- S & F factory built hermatically sealed compressor unit suitable for 1.5 Ton capacity split / window type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerent gas including taking out old unserviceable compressor from the split type AC complete all as specified and directed
S&F factory built hermatically sealed compressor unit suitable for 2.0 Ton capacity split type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerent gas including taking out old unserviceable compressor from the split type AC complete all as specified and directed
S & F factory built hermetically sealed compressor unit suitable for 2.5 Ton capacity split type AC, testing the leak of compressor by charging Dry Nitrogen gas, evacuating the system and charging R-22 /304 a /407a /134 Refrigerent gas including taking out old unserviceable compressor from the split type AC complete all as specified and directed.
M & L repairing the leaking area and recharging refrigerent R-22 /304 a /407a /134 gas for Window / Split type AC, Water cooler, Refrigerator, Deep freezer etc complete all as specified.
M&L on site servicing 1.5 / 2.0 / 2.5 Ton capacity split / window type AC of any description by cleaning air filter, cooling / condensor coil and outer cabinet with pressurised water and detergent solution, applying new insulation to torn/damaged insulation complete all as specified to the satisfaction of Engr in charge.
S & F condensor fan motor with capacitor and mounting materials, single phase, 230 Volts, 50 Hz suitable for 1.0/1.5/2.5 Ton capacity split type AC including taking out old unserviceable blower motor complete all as specified.
S & F in repair thermostatic switch suitable for 1.5 / 2.0 / 2.5 Ton capacity split / window type AC complete all as specified.
S & F in repair overload relay suitable for 1.5 Ton capacity window type AC complete all as specified.
S & F in repair starting relay suitable for 1.5 /2.0 Ton capacity window type AC complete all as specified.
S & F in repair copper condenser suitable for 1.5 Ton capacity split / window type AC complete all as specified.
S & F in repair copper condenser suitable for 2.0 Ton capacity split type AC complete all as specified.
S & F in repair copper condenser suitable for 2.5 Ton capacity split type AC complete all as specified.
S & F in repair 30 / 36 mfd running capacitor suitable for 1.5 / 2.0 / 2.5 Ton capacity split / window type AC complete all as specified.
S & F in repair PVC fan blade suitable for 1.5/2.0/2.5 Ton capacity split / window type AC complete all as specified.
S & F in repair PCB suitable for 1.5 /2.0 /2.5 Ton capacity split / window type AC complete all as specified.
S & F in repair liquid strainer suitable for 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified.
S & F in repair capillary tube for 1.5 / 2.0 / 2.5 Ton capacity split type AC complete all as specified.
REFRIGERATION S & F factory built hermatically sealed compressor unit suitable for 175 / 205 Ltrs capacity Refrigerator, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-600 Refrigerent gas including taking out old unserviceable compressor from the Refrigerator complete all as specified and directed
S&F factory built hermatically sealed compressor unit suitable for 285 / 310 / 340 Ltrs capacity Refrigerator, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-600 Refrigerent gas including taking out old unserviceable compressor from the Refrigerator complete all as specified and directed.
S & F in repair thermostatic switch suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified.
S & F in repair starting relay suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified.
S & F in repair door switch suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified.
S & F in repair drier filter of size 1/4" x 1/4" flare connection suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified.
S & F in repair overload relay suitable for 175 / 205 / 285 / 290 / 310 / 340 Ltrs capacity Refrigerator complete all as specified.
S & F in repair electronic fan motor, single phase, 230 Volts, 50 Hz suitable for 425 Ltrs capacity Deep freezer complete all as specified.
S & F in repair thermostatic switch suitable for 425 Ltrs capacity Deep freezer complete all as specified.
WATER COOLER:- S&F factory built hermatically sealed compressor unit suitable for 40 / 60 / 80 Ltrs capacity water cooler, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134/R-22 Refrigerent gas including taking out old unserviceable compressor from the water cooler complete all as specified and directed
S&F factory built hermatically sealed compressor unit suitable for 100 / 150 Ltrs capacity water cooler, testing the leak of compressor by charging dry Nitrogen gas, evacuating the system and charging R-134 / R-22 Refrigerent gas including taking out old unserviceable compressor from the water cooler complete all as specified and directed
S & F in repair starting relay assembly suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair running capacitor suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair overload relay suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair thermostatic switch suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair 15mm dia brass chromium plated push cock / lifting cock suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair 15mm dia PVC high pressure ball valve with polythene float & fly nut suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair condensor fan motor, single phase, 50 Hz, 230 Volts suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair 15mm dia, 450mm long, PVC connection with brass check nuts, complete all as specified.
S & F in repair liquid strainer suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
S & F in repair capillary tube suitable for 40 / 60 / 80 / 120 Ltrs capacity water cooler complete all as specified.
M & L comprehensive maint of water purifier, electrically operated, Best Water Doctor / Cross Field by servicing parts, attending break down, renewal of parts including checking the equipment by the Service Engineer once in a month complete all as specified & directed.(4 Nos x 11 Months = 44 Jobs) Note :- (i) Replacement of parts will be measured and paid as supply only separately. (ii) The cost of labour and consumables required for replacement of parts shall deem to include in the unit rate quoted by the contractor.
Supply only D2 Main PCB suitable for water purifier complete all as specified.
Supply only compressor suitable for water purifier capacity upto 10 ltr complete all as specified.
Supply only solenoid valve suitable for water purifier complete all as specified.
Supply only two way valve suitable for water purifier complete all as specified.
Supply only PF candle (Industrial) suitable for water purifier complete all as specified.
Supply only PF Bowl & cap suitable for water purifier complete all as specified.
Supply only compressor relays suitable for water purifier complete all as specified.
Supply only compressor fan motor suitable for water purifier complete all as specified.
Supply only thermostat (cooler) suitable for water purifier complete all as specified.
Supply only thermostat (heater) suitable for water purifier complete all as specified.
Supply only heating element suitable for water purifier complete all as specified.
S & F SPN enclosure with two pin and earth plug and socket complete with one MCB, SP, 20 Amps, having breaking capacity 10 kA, dual termination, isolation function with visual indication complete all as specified.
S & F in repair 3 core, 2.5 Sqmm copper conductor, PVC insulated sheathed flexible cord complete all as specified.
S & F in repair 3 core, 4.0 Sqmm copper conductor, PVC insulated sheathed flexible cord complete all as specified.
S & F in repair 3 core, 6.0 Sqmm copper conductor, PVC insulated sheathed flexible cord complete all as specified.
S & F in repair industrial plug top suitable for industrial socket complete all as specified. Make : Legrand / Standard / Havells
S & F in repair SMPS based voltage stabilizer 2 KVA wall mounting type complete incl mounting accessories all as specified.
S & F in repair SMPS based voltage stabilizer 5 KVA wall mounting type complete incl mounting accessories all as specified.
S & F in repair 1/4 X 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified.
S & F in repair 3/8 x 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified.
S & F in repair 5/8 x 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified.
S & F in repair 1/2 x 0.61 OD copper pipe including connecting to split type AC and applying insulation complete all as specified.
Material and labour for comprehensive maintenance of 10 KVA, UPS by servicing of all parts, tightening of all electrical connections, applying petroleum gelly to battery terminals, repair / replacement of battery leads, attending the break down, repair / renewal of any parts except battery and make the UPS functional including preventive maintenance of UPS once in a month complete all as specified and directed. (1 Nos x 11 months = 11 Jobs).
S & F in repair PCB suitable for 10 KVA, 3 phase UPS complete all as specified. Make : Aplab
S & F in repair transformer unit for 10 KVA, 3 phase UPS complete all as specified. Make : Aplab
S & F in repair display unit for 10 KVA, 3 phase UPS complete all as specified. Make : Aplab
S & F in repair maint free battery 12 Volt, 42AH in fully charged condition complete all as specified. Make : Exide / Amron.
S & fix PVC drain pipe one meter long 32mm dia heavy duty with two nos of galvanized adjustable clamps including taking down existing complete all as specified and directed.
S & fix PVC float valve suitable 15 mm dia assembly and comprising valve assembly alum rod, PVC ball for water cooler/ desert coolers including taking down existing complete all as specified and directed. Make :- Paryag / Polytuff
S & fix Overload protector relay 2613 including taking down existing complete all as specified and directed . Make: Techemshah/ Hitachi.
Opening of Refrigerators freeze of capacity 285/310 ltrs refixing the same after flushing out and removal of blockage brazing, renewal of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling ( Temperature) complete including testing all as specified and directed .
Opening of Refrigerators freeze of capacity 265 ltrs refixing the same after flushing out and removal of blockage brazing, renewal of liquid line filter and recharging the refrigerator with freon-12 refrigerant to obtain the desired cooling ( Temperature) complete including testing all as specified and directed .
M & L for shifting of split AC 1.5/2.0 TR capacity including the disconnection outdoor and indoor unit, re-installed the same after necessary connection to new location including testing and commissioning complete all as specified.
M & L for AC bracket mounting to outdoor unit if any capacity including making good to disturbed surfaces complete all as specified.
COMPREHENSIVE MAINT OF APFC PANEL: M & L comprehensive maintenance of 20 Nos Automatic Power Factor correction capacitor banks, 40 to 340 KVAr including repair/renewal of defective/un-serviceable parts during maintenance period, attending to breakdown as and when it is occurres, necessary periodical checking twice in a month and testing of capacitor banks as per manufacture's instruction for smooth and effficient functioning of capacitor panels, installed at various Sub Stations and Power Houses.
Note :- (i) The Power Factor should always be maintained more than 0.95. (ii) if the Power Factor comes below 0.95 upto .09, a penalty of Rs.1000.00 per HT connection will be recovered from the payment. (iii) If KSEB imposes any penalty due to low power factor than 0.9 then double the amount will be recovered from the contractor as penalty for non functioning of panel. (iv) The rate quoted shall be deemed to be included the charge for taking out defective spares & fixing of new spares and tightening of cables & accessories etc. (v) Cost of spares required for replacing shall be measured and paid separately. (vi) 2 Weeks x 11 Months = 22 Jobs
Supply only 2 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 5 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 7.5 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 10 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 12.5 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 15 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 20 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 25 KVAr Capacitor, 3 phase, 440 Volt AC having low watt loss of not less than 0.5 W/KVAR ,all as directed.
Supply only 16Amp Capacitor duty contactors ,all as directed. Make : L&T / Siemens / ABB
Supply only 30 Amp Capacitor duty contactors ,all as directed. Make : L&T / Siemens / ABB
Supply only 230 Volt Control relay ,all as directed. Make : L&T / Siemens / ABB
Supply only Microprocessor based APFC relay, 14/12 stage ,all as directed. Make : L&T / Siemens / ABB / Shneider
Supply only flush head 230 Volt AC Push Button ,all as directed.
Supply only LED type neon indicator lamp (RYB) 230 Volt ,all as directed.
Supply only LED type three phase Voltmeter ,all as directed.
Supply only LED type three phase Ampher meter with CTs ,all as directed.
Supply only MCB, SP, 6 Amps, having breaking capacity 10 kA, dual termination, isolation function with visual indication complete all as specified.
Supply only MCB, TP, 63 Amps, having breaking capacity 10 kA, dual termination, isolation function with visual indication complete all as specified and as directed.
ELAN ENGINEERS
Albert Rebello and Company
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .