Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹6.9 LAccepted-AOC | ₹6.9 L | L1 | Accepted-AOC L1 |
| 2 | L2₹7.3 LRejected-AOC VANIYAPURACKAI HOUSE PURAKKAD PO ALAPPUZHA | ALAPPUZHA | ALAPPUZHA | KERALA | ₹7.3 L | L2 | Rejected-AOC L2 |
| 3 | L3₹7.9 LRejected-AOC | ₹7.9 L | L3 | Rejected-AOC L3 |
| 4 | L4₹8.4 LRejected-AOC | ₹8.4 L | L4 | Rejected-AOC L4 |
| Sl No | Description | Qty | Unit | PT.Sebastian L1 | Shaji.V L2 | AVINASH R L4 | P.T.MICHAEL L3 |
|---|---|---|---|---|---|---|---|
| 1.00Appendix | |||||||
| 1.00 | 15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix) | 6.98 | cum | 2,200 ₹15,364.80 | 2,135 ₹14,910.84 | 2,465 ₹17,215.56 | 2,304.5 ₹16,094.63 |
| 1.00 | 22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for
waterproofing treatment to the RCC structures like retaining walls of the basement,
water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels
/ subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts
integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts
integral crystalline slurry : 1 part water) for horizontal surfaces and applying the
same from negative (internal) side with the help of synthetic fiber brush. The material
shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing
permeability of concrete by more than 90% compared with control concrete as per
DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline
slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work
shall be carried out all complete as per specification and the direction of the engineerin-
charge. The product performance shall carry guarantee for 10 years against any
leakage.For vertical surface two coats @0.70 kg per sqm | 40.6 | sqm | 500 ₹20,300 | 433 ₹17,579.80 | 499 ₹20,259.40 | 466.45 ₹18,937.87 |
| 1.00 | 4.2.2:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources | 4.95 | cum | 11,200 ₹55,417.60 | 10,435 ₹51,632.38 | 12,050 ₹59,623.40 | 11,244.89 ₹55,639.72 |
| 1.00 | 5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers | 68.38 | sqm | 660 ₹45,130.80 | 645 ₹44,105.10 | 740 ₹50,601.20 | 698.49 ₹47,762.75 |
| 1.00 | 13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand) | 89.24 | sqm | 369 ₹32,929.56 | 395 ₹35,249.80 | 455 ₹40,604.20 | 429.62 ₹38,339.29 |
| 1.01 | 22.8.1:Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/ 15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete with :Bitumen felt ( hessian base) type 3 grade I conforming to IS : 1322 | 89.24 | sqm | 541 ₹48,278.84 | 460 ₹41,050.40 | 525 ₹46,851 | 496.15 ₹44,276.43 |
| 1.01 | 13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. | 917.54 | sqm | 12 ₹11,010.49 | 17 ₹15,598.20 | 20 ₹18,350.82 | 18.75 ₹17,203.89 |
| 1.01 | 13.109.1:Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat. | 142.51 | sqm | 85 ₹12,113.01 | 99 ₹14,108.09 | 115 ₹16,388.19 | 108.1 ₹15,404.90 |
| 1.01 | 13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work | 917.54 | sqm | 112 ₹1.0 L | 140 ₹1.3 L | 168 ₹1.5 L | 158.29 ₹1.5 L |
Tender Value
₹8.6 L
EMD Value
₹21,483
Closing Date
19 Jan 2026, 3:00 pmClosed
Assistant Executive Engineer
O/o The Assistant Executive Engineer,PWD Special Buildings Subdivision,Alappuzha
GENERAL GTDMC Vandanam Ladies Hostel no 2 Leak rectification of expansion joints at the rooftop replacement of damaged floor tiles sheet roofing over the terrace at the passage area and repainting of damp walls at the expansion joint area Genera
2026_PWD_826775_1
PWD/BLDG/TR/204/2024(31/AEE)
Open Tender
Civil Works - Buildings
180 days
Alappuzha
Please refer Tender documents.
9 documents required · 9 mandatory
₹1,895
₹21,483
10 Feb 2026
9 Jan 2026
21 Jan 2026
9 Jan 2026
19 Jan 2026
9 Jan 2026
Appendix
15.2.1:Demolishing cement concrete manually / by mechanical means including disposal of material within 50 metres lead as per direction of Engineer - in-Charge.Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin- charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
4.2.2:Providing and laying cement concrete in retaining walls, return walls, walls ( any thickness) including attached pilasters, columns, piers, abutments, pillars, posts, struts,buttresses, string or lacing courses, parapets, coping, bed blocks, anchor blocks, plain window sills, fillets, sunken floor, etc. up to floor five level, excluding the cost of centering, shuttering and finishing:1:1½:3 (1 cement : 1½ coarse sand (zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
13.7.1:12 mm cement plaster finished with a floating coat of neat cement of mix:1:3 ( 1 cement : 3 fine sand)
22.8.1:Providing and laying four courses water proofing treatment with bitumen felt over roofs consisting of first and third courses of blown bitumen 85/25 or 90/ 15 conforming to IS : 702 applied hot @ 1.45 Kg per square metre of area for each course, second course of roofing felt type 3 grade-I (hessian based self finished bitumen felt) and fourth and final course of stone grit 6 mm and down size or pea sized gravel spread at 6 cubic decimeter per square metre, including preparation of surface but excluding grading complete with :Bitumen felt ( hessian base) type 3 grade I conforming to IS : 1322
13.88:Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete.
13.109.1:Finishing walls with water proofing cement paint of required shade :Old work (one or more coats applied @ 2.20 kg/10 sqm) over priming coat of primer applied @ 0.80 litrs/10 sqm complete including cost of Priming coat.
13.60.1:Wall painting with acrylic emulsion paint of approved brand and manufacture to give an even shade:Two or more coats on new work
13.99.1:Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade :One or more coats on old work
15.23.1:Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead.For thickness of tiles 10 mm to 25 mm
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
OD221263/2023-2024:Providing and laying epoxy grouted vitrified floor tiles(Grouting the joints of flooring tiles having joints of 3mm width, using epoxy grout mix 0.70kg of organic coated filler of desired shade (0.1 kg of hardener and 0.20 kg of resin per kg) (thickness to be specified by the manufacturer), in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., including deduction for not grouting the joints with white cement and matching pigment etc., complete. Size of Tile 600 x 600 mm.,
11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
50.10.2:Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete
OD221326/2023-2024:Providing and fixing Aluminium powder coated profile sheets (Size ,shape and pitch of corrugation as approved by Engineer-in-charge)0.46mm (+0.05%),total coated thickness with zinc coating 120 grams per sqm as per IS:277,in 240 mpa steel grade,5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns.sheet should have protective guard film of 25 microns minimum to avoid sratches during transportation and should be supplied in single length up to 12 metre or as desired by Enginner -in-charge . The sheet shall be fixed using self drilling /self tapping screws of size (5.5x55 mm) with EPDM seal ,complete up to any pitch in horizontal/vertical or curved surfaces,excluding the cost of purlins,rafter and trusses and including cutting to size and shape wherever required.
OD221325/2023-2024:Providing ridge caping using aluminium powder coated sheet 0.46mm thick using self drilling screws, washer with necessary overlap etc. complete.
OD204339/2025-2026:OD85682/2023-2024 providing at all heights,levels and locations Al plain sheet. The sheet shall be fixed using self drilling screws
OD221381/2023-2024:supplying and fitting 200mm PVC pathy 6Kg/cm2 for gutter including 25x6mm think M.S clamp at 75cm c/c including all cost and labour charges etc complete
50.18.7.6.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 6 Kgf/cm2 - Internal work- Exposed on wall
50.18.9.20.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 63 mm dia Bend
50.18.9.20.5:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes including jointing with PVC solvent cement - 63x63x63 mm dia Tee
50.18.9.19.1:Providing and fixing PVC pipes including fixing the pipe with clamps/ clips/ at 1.00 m spacing . This includes jointing of pipes with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 110 mm dia 6 Kgf/cm2 - External work- Exposed on wall
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
OD212141/2023-2024:Engaging carpenter for repairing wooden doors ,windows and roof members
OD212142/2023-2024:Engaging plumber for dismantling existing plumbing lines,repairing sanitary fittings and water lines as per the direction of Engineer in charge
Please Enable Macros to View BoQ information
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_1387010.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 1.03 MB
sbd.pdf
Tender Documents • 1.64 MB
affidavit.pdf
Other Document • 0.03 MB
bis.pdf
Other Document • 0.56 MB
Circular.pdf
Other Document • 20.04 MB
BOQ_1387010.xls
BOQ • 0.32 MB
PA.pdf
Additional Documents • 0.24 MB
epay.pdf
Additional Documents • 0.06 MB
Download all tender documents and submit your bid