Electrical wiring renovation job at floor lobby areas of 3rd 4th 5th floor SDF Building
2020_WEBEL_300084_1
EC/07/SDF/Lobby Wiring/Etender/20-21/M08
Open Tender
IT WORKS ORG
Item Rate
120 days
SDF BUilding Salt Lake SEC V
Please refer to the tender docs
5 documents required · 5 mandatory
₹1,000
WBEIDC Ltd
₹4,200
3 Dec 2020
7 Oct 2020
5 Nov 2020
7 Oct 2020
4 Nov 2020
13 Oct 2020
Amount
Supply, installation, testing & commissioning with necessary electrical connection of 22W LED (cool day light, round, Model- Dura Slim, Make-Philips) recessed mounted round downlight fixture to be mounted on false ceiling as per requirement. Job rate should include necessary dismantling of existing old fixtures & connections, making cut outs on new false ceiling, necessary GI chain & supporting suspending hardware with all accessories for installation of new fixtures as required.
Supply, installation, testing & commissioning with necessary electrical connection of 20 watt LED 4 feet tubelight set using all necessary accessories as per requirement, make- Philips. Job rate should include necessary dismantling of existing old fixtures & wirings as required.
Point Wiring: Supply, installation, testing & commissioning of distribution wiring in 1.1 KV grade (1.5 sq.mm. x 2 ) + (1.5 sq.mm. x 1) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) on wall / above false ceiling / concealed by using suitable size PVC rigid or flexible conduit 'FR' / PVC casing-capping including necessary fittings etc. to light / fan point with 6A Modular type switch with indicator & 6A 5 pin modular plug socket (Make- Legrand, Model-Arteor), duly wired all the switches sockets are with front plates & PVC boxes including wire laying, connection making, earthing attachment, mending good damages to building works etc. as per requirement. Job rate should include necessary dismantling of existing old fixtures & wirings as required.
Point Wiring: Supply, installation, testing & commissioning of distribution wiring in 1.1 KV grade (4 sq.mm. x 2 ) + (1.5 sq.mm. x 1) single core stranded 'FR' PVC insulated & unsheathed copper wire (Brand approved by EIC) on wall / above false ceiling / concealed by using suitable size PVC rigid or flexible conduit 'FR' / PVC casing-capping including necessary fittings etc. with 16A Modular type switch with indicator & 16A 5 pin modular plug socket (Make- Legrand, Model-Arteor), duly wired all the switches sockets are with front plates & PVC boxes including wire laying, connection making, earthing attachment, mending good damages to building works etc. as per requirement. Job rate should include necessary dismantling of existing old fixtures & wirings as required.
Supply, installation, testing & commissioning of 4 Way TPN Double Door Horizontal MCB DB with IP-42/43 protection & 32A FP C-Type MCB (1 no.), 6A/10A/16A SP C-type MCB (12 nos.), MCB Breaking Capacity-10KA (Make-Legrand/ABB/ Siemens/Reputed- as directed by EIC), concealed in wall after cutting the wall & mending good damages to original finish including necessary connection using suitable size of copper wire and neutral link & earthing attachment using 2 x 10 SWG GI (Hot Dip) wire (including necessary dismantling of existing fixtures).
Supply, installation, testing & commissioning of 100A 4 Pole MCCB, 18KA, Model-DU100D with enclosure, Make- L&T including necessary cable termination with accessories as required (including necessary dismantling of existing fixtures).
Dismantling of existing equipments (e.g. Smoke/heat detector & indicator, camera etc) from false ceiling for civil work & reinstallation on new false ceiling after making cut outs including necessary connection as required.
Cable dressing providing suitable cable supporting structures / hangers (using approx. 100 micron Hot dip galvanised 4 ft. GI angle ISA4040 x 6mm as base, 2.5 ft. x 12mm full threaded G.I. bullet fastener, hanger to hanger distance approx 0.5 metre, applying single coat Red Lead primer & double coat Black Japan paint on the GI support structure) as per requirement.
Supply & laying of (2.5 sq.mm. x 2C) + (1.5 sq.mm. x 1C), 1.1KV FRLS PVC insulated Cu conductors through surface/Ceiling/wall/concealed including necessary connection with PVC conduit / casing-capping & accessories as required (including necessary dismantling of old wiring).
Supply & laying of (1.5 sq.mm. x 2C) + (1.5 sq.mm. x 1C), 1.1KV FRLS PVC insulated Cu conductors through surface/Ceiling/wall/concealed including necessary connection with PVC conduit / casing-capping & accessories as required (including necessary dismantling of old wiring).
SATABDI ENGINEERING COMPANY
KUNDU ENTERPRISE
ADAS INDIA
AN HOUR SOLUTION PVT LTD
XPO REFRIGERATION ENGINEERS
The Suburban Electric Co.
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .