| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹9.6 LAccepted-AOC SABAR KANTHA GUJARAT | SABAR KANTHA | GUJARAT | L1 | Accepted-AOC LOWEST BIDDER | |
| 2 | L2₹10.4 L+₹54,710 (5.56%)Rejected-Finance | L2 | Rejected-Finance NOT LOWEST BIDDER | |
| 3 | Not Admitted-Fee/PreQual/Technical | - | Not Admitted-Fee/PreQual/Technical EMD/Fee not received | |
| 4 | Rejected-Technical | - | Rejected-Technical Technically Disqualified |
Tender Value
₹9.2 L
EMD Value
₹23,100
Closing Date
3 Oct 2020, 3:00 pmClosed
The Superintending Engineer IIT Gandhinagar
The Superintending Engineer, Building and Works Department, Indian Institute of Technology Gandhinagar, Academic Block-3-306C, Palaj, Gandhinagar
Provision of mechanical water proofing treatment to expansion or crumple joints in non assessable bridge and other places in all Academic Block at IITGN
2020_IITGN_584789_1
09/IITGN/ IWD /2020-21
Open Tender
Civil Works - Buildings
Item Rate
60 days
IIT Gandhinagar
As per Tender Documents
2 documents required · 2 mandatory
₹500
Payable To IIT Gandhinagar
₹23,100
10 Nov 2020
18 Sept 2020
5 Oct 2020
18 Sept 2020
3 Oct 2020
22 Sept 2020
19 Sept 2020 - 22 Sept 2020
Amount
Demolishing cement concrete manually/ by mechanical means including disposal of material within 50 metre lead as per direction of Engineer - in - charge.
Nominal concrete 1:3:6 or richer mix (i/c equivalent design mix)
Dismantling stone slab flooring laid in cement mortar including stacking of serviceable material and disposal of unserviceable material within 50 metres lead.
Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to five level :
1:1½:3 (1 Cement: 1½ coarse sand (zone-III) : 3 graded stone aggregate 20 mm nominal size)
Kota stone slab flooring over 20 mm (average) thick base laid over and jointed with grey cement slurry mixed with pigment to match the shade of the slab, including rubbing and polishing complete with base of cement mortar 1 : 4 (1 cement : 4 coarse sand) :
25 mm thick
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing , curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge.
Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Supply and Installation of mechanical expansion joint system of standard make related with floor location as per drawing and direction of Engineer-IN-Charge. The joints system will be of extruded aluminium base member, self aligning / self cantering arrangement and support plates etc. as perASTMB221-02. The system shall be such that it provides floor to floor / floor to wall expansion control System for various vertical location in load application are at hat accommodate multi directional seismic movement without stress to it's components. System shall consist of metal profiles with a universal aluminium base member designed to accommodate various project condition and finish floor treatments. The cover plate shall be designed of width and thickness required to satisfy projects movement and loading requirement stand secured to base members by utilizing manufacture's pre-engineered self- centerin g arrangement that freely rotates /moves in all direction. The Self centering arrangement shall exhibit circular sphere ends that lock and slide inside the corresponding aluminium extrusion cavity to allow free dom of movement and flexure in all direction including vertical displacement. Provision of Moisture Barries Membrane in the joint system to have water tight joint is mandatory requirement all as per manufactures design and as approved by Engineer-in-Charge. (Material shall confirm to ASTM 6063.)
Floor to Floor/Corner Expansion Joint system for 50 mm gap.
Supply and installation of Hercules Floor Combination joint system comprising of Water barrier which is fixed at mother slab level to make the joint water tight, a top plate is placed on the top fixed with the aluminium extrusion as per the drawings, the top level of the joint system is filled with the Hercules Compression seal. The whole assembly is designed to bear the Pedestrain load and shall have movement capacity of +/- 50% of the total joint gap.
Roof to Roof expansion joint system for 50 mm gap.
OM CONSTRUCTION
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.PDF
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .