| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹41.8 LAccepted-Finance 74 AJANTA COMMERCIAL CENTRE ASHRAM ROAD AHMEDABAD 380014 | AHMEDABAD | AHMEDABAD | GUJARAT | 380014 | L1 | Accepted-Finance Accepted | |
| 2 | L2₹42.4 L+₹64,493 (1.54%)Rejected-Finance A 3 13 SIMANDHAR ENCLAVE NEAR PAVAPURI BUS STOP GHATLODIYA AHMEDABAD GUJARAT 380061 | AHMADABAD | GUJARAT | 380061 | L2 | Rejected-Finance Rejected due to bidder not L1 | |
| 3 | L3₹61.7 L+₹19.9 L (47.7%)Rejected-Finance INS VALSURA JAMNAGAR | JAMNAGAR | GUJARAT | 360520 | L3 | Rejected-Finance Rejected due to bidder not L1 | |
| 4 | Rejected-Technical PAHARGANJ SECOND COLONY LAL SAGAR JODHPUR 342001 RAJ | JODHPUR | JODHPUR | RAJASTHAN | 342001 | - | Rejected-Technical Rejected due to NO remarks in WLR |
Tender Value
₹38.8 L
EMD Value
₹77,520
Closing Date
19 Dec 2024, 6:00 pmClosed
GE (Army) Ahmedabad
Office of the GE (Army) Camp Hanuman, Ahmedabad - 380 004
SPECIAL REPAIR/REPLACEMENT OF OLD/DAMAGED LT PANELS AND LT CABLES DISTRIBUTION UNDER GE (A) AHMEDABAD.
2024_MES_684162_1
8235/E8
Open Tender
Civil Works
Item Rate
270 days
GE (Army) Ahmedabad
AS PER NIT
8 documents required · 8 mandatory
₹500
GE (Army) Ahmedabad
₹77,520
Yes
3 Jan 2025
16 Nov 2024
21 Dec 2024
16 Nov 2024
19 Dec 2024
7 Dec 2024
16 Nov 2024 - 30 Nov 2024
Amount
Notes : (i) The work consists of 01 job as under:- JOB (A) : 02/SR/E&M/STN HQ/ADI/2024-25/Q3 (ii) Please refer schedule 'A' notes before quoting the tender. (iii) Amount of Schedule of Credit shall be deducted off line by the department. ITEMS FOR JOB 'A'
M&L for taking down of old unserviceable LT panel any type any size any capacity including all accessories after disconnecting elect cable connection from MCCB/MCB/Capacitor/Earthing terminals from exising site and dismantaling of foundation without damaging of LT cables and keep aside complete all as directed.
Supply, errect, test and commissioning LT feeder pillar box out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 2mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 1600 Amps capacity insulated, Digital ammeter 0-2000 amps, with CTs, Digital voltmeter 0-2000 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation comprising the following:- size -- approx (2 x 1.5x 0.8 Mtr)
(i) Incoming (Main) :- One numbers MCCB 800 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz with thermal magnetic release adjustable lcs=100% lcu against overload setting connected through suitable size copper bus bas coated with insulating sleeves.
Outgoing:- (i) Six Numbers MCCB 350 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz.
(ii) Three Numbers MCCB 250 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
(iii) One Number MCCB 125 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
(iv) One Numbers of panel mounted on-load AC changeover connected through suitable size of copper bus bar coated with insulating sleeves capacity of 400 Amps, 415 Volt, 4 pole, 50 Hz
Supply, errect, test and commissioning LT Panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 2 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 800 Amps capacity insulated, Digital ammeter 0-1000 amps, with CTs, Digital voltmeter 0-1000 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation comprising the following:- size -- approx (1.5 x 1x 0.5Mtr)
(i) Incoming (Main) :- One numbers MCCB 350 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
Outgoing:- (i) Two Numbers MCCB 250 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
(ii) Two Numbers MCCB 160 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
(iii) Two Numbers MCCB 100 amp, 4 pole, Ics 36 KA, 415 volts, 50 Hz
Supply, errect, test and commissioning LT panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 3.15 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 600 Amps capacity insulated, fixed with epoxy based Digital ammeter 0-500 amps, with CTs, Digital voltmeter 0-500 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation minimum 60cm from normal ground level comprising the following:- size - approx (1 x 1x 0.5Mtr)
(i) Incoming (Main) :- One numbers MCCB 250 amp, 4 pole, Ics 50 KA, 415 volts, 50 Hz
Outgoing:- (i) Six Numbers MCCB 125 amp, 4 pole, Ics 16 KA, 415 volts, 50 Hz
Supply, errect, test and commissioning Bus bar LT panel out door type, slanting top, from CPRI type tested approved manufacturer fabricated, powder coated, dust & vermin proof, air vent gasket for natural air flow including removal cable entry gland plate, power coated 440 volts, 3 phase, 4 pole, 50 cycles outdoor type weather proof made out of 3.15 mm thick CRCA sheet, seperated chamber will be made with 3.15 mm thick CRCA for each switch gear and bus bar with MS Chanel base frame of size 75mmx75mmx6mm, hinged door, double locking arrangement with 'U' shape gasket on on door panel with aluminium bus bar 400 Amps capacity insulated, fixed with epoxy based Digital ammeter 0-500 amps, with CTs, Digital voltmeter 0-500 volts , LED indicating lamp with Kit-Kat control fuses for RYB installed and including on PCC 1:3:6 type C1 as per OEM drawing size of foundation minimum 60cm from normal ground level comprising the following:- Size (Approx 0.9 x 0.7x 0.45 Mtr)
One numbers MCCB 250 amp, 4 pole, Ics 50 KA, 415 volts, 50 Hz Make Legrand
Supplying, installation. Connecting electrically & commissioning and testing of Outdoor type free standing type (IP -42) automatic power factor correction system with both auto and manual options type Inlet Var APFC Panel with MD-XL capacitors and MCCB as incomer factory made Non compartmentalised single unit 440 Volts 50 Hz. 3 phase 100 KVAR (Multiple of 5 KVAR) Complete all as specified and as directed including the following (a) Double Metallized paper with polypropylene film cylinderical, type MD-XL capacitor bank of rated voltage 525 volts with detuned Reactor of de tuning factor (P) 7% and suitable output of 100 KVAr at 440 Volts confirming to IS -13340, 13341. & IEC-60831 -1+2 Make: ABB/Schneider (Mehar) / Areava/ Seimens/L&T/Havells (b) Capacitor duly contactor with Damping Resistors appropriate rating for capacitor switching confirming to IEC-60070 & IS 13947 Makes: ABB/ AREVA/ Schneider/L&T/Havells (c) Automatic power factor controller relay micro processor based for switching ON & OFF of capacitors and suitable to display of voltage, current, active power, Reactive power, Apparent power. Display of power factor, THD Voltage, THD current, alarm indication for defective steps, low power factor and excess temperature. The relay has volt free c/o contact, Automatic detection and usage of optimum capacitors (i) Capable of 4 - Quadrant operation, and any phase offset requirement. (ii) Swithching programms LIFO, Combi filter, manual mode. (iii) Build in under and over voltage release with auto reset. (iv) Large Voltage input band of 90 Volt to 550 Volt, 45-65 Hz. (v) Current measuring 10 mA-5A, Suitable for CT x/1A and x/5A.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor including cable glands,cable lugs of following size ;-
185 sq mm 3.5 core
120 sq mm 3.5 core
95 sq mm 3.5 core
70 sq mm 3.5 core
50 sq mm 3.5 core
35 sq mm 3.5 core
25 sq mm4core
16 sq mm 4 core
10 sq mm 4 core
Excavation in trenches in any type of hard/dense soil n exc 1.5 mtr in width and n. exc 1.5 mtr in depth and getting out all as required for laying of cables,Foundation filling of poles or stays.
Returning filling, in including spreading ,leveling, watering and well ramming in layers not exc 25 cm each all as required.
Removing excavated material to a distance not exceeding 50 meters and depositing where directed at a level not exc 1.5 mtr above the starting point.
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 50 mm and inner dia 38 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 77 mm and inner dia 63 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed
Supply and laying of DWC (double wall corrugated) HDPE pipe, ISI marked, IS 16205 (part 24) : 2017 Part II of outer dia 120 mm and inner dia 103 mm with smooth internal and profiled external surface for non pressure underground cables including all connected accessories like coupler, o-ring etc complete all as specified and directed
M&L for disconnecting and taking down exising serviceable cables of any size and any type carefully, shifting and relaying in new location and connectiong complete with new cable lugs, thimbles, nut bolts and jointing all as specified and as directd Note: Excavation and earthwork will be measured and paid saperately under relavent items.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm
Supply and fix Cable jointing kit for 11 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 50 sqmm to 95 sqmm.
Supplying and fixing MCCBs 160 amp, 4 pole, with breaking capacity 36 K Complete all as specified and directed
Supplying and fixing MCCBs 250 amp, 4 pole, with breaking capacity 36 KComplete all as specified and directed.
M&L for detection and locating of cable fault in underground damaged LT cable any size of any length and any type using cable fault detector/ locator machine of accuracy to 2 meters , vehicle mounted for various locations under GE(A) Ahmedabad including necessary excavation & earthwork in any type of strata of size required for visually inspection/repairing the damaged cable when and where directed
S&F steel tubes light grade galvanized 100 mm bore ISI marked with all fittings fixed to walls / floors / road crossing, poles as required.
M&L Labour & tools for horizontal boring through road / path / floor for passing UG cables by using trench less technology for laying upto 100mm dia GI pipe complete all as required. Note : GI pipe will be measured and paid seperately.
M&L for Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less'than 1.5 metres below normal ground level, connected to galvanised earth lead wire 4.0mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion.
Dismantling existing serviceable MCCB/ HRC Fuses/LBS from existing Panel & refixing in new location all as specified and directed.
Dismantling old u/s LT Panel with bus bar & connections, u/s panel meters and accessories except MCCB/HRC Fuses.
Dismantling old u/s MCCB/HRC Fuse/ LBS etc:-
old u/s MCCB from 32 Amp to 200 Amp
Old u/s MCCB 200A to 400 Amp
Old u/s HRC Fuse.
JYOT ENTERPRIES (BID ID -3187398)
BHAVNA IMPERIAL ENTERPRISE (BID ID -3193451)
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .