| 1 | L1₹13.4 CrAccepted-AOC KANNUR | KERALA | 670001 | L1 | Accepted-AOC L1 | |
| 2 | L2₹13.2 Cr−₹16.5 L (1.24%)Rejected-AOC | L2 | Rejected-AOC L2 |
| Sl No | Description | Qty | Unit | Saraswathy Constructions L1 | THE URALUNGAL LABOUR CONTRACT CO-OPERATIVE SOCIETY L2 |
|---|---|---|---|---|---|
| 1.00Foundation & Basement | |||||
| 1.00 | OD244948/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: No extra payment shall be made for extra cement in the design mix of the subdata): 700 mm dia piles | 496 | metre | 9,000 ₹44,64,000 Lowest | 10,000 ₹49,60,000 |
| 1.00 | OD244951/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: No extra payment will be made for extra cement in the design mix of subdata) - 800 mm dia piles | 624 | metre | 10,200 ₹63,64,800 Lowest | 11,000 ₹68,64,000 |
| 1.00 | OD265270/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap) (No extra payment shall be made for the design mix in the sub data). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used:1000 mm dia piles | 480 | metre | 13,500 ₹64,80,000 Lowest | 13,500 ₹64,80,000 Lowest |
| 1.00 | 20.6.2.1:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityInitial test (Test Load 2.5 times the Safe capacity) | 3 | per test | 5,75,000 ₹17,25,000 Lowest | 7,64,000 ₹22,92,000 |
| 1.00 | 20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity) | 3 | per test | 3,60,000 ₹10,80,000 Lowest | 4,58,000 ₹13,74,000 |
| 1.01 | 20.9:Integrity testing of pile using Low Strain / Sonic Integrity Test/ Sonic Echo Test method in accordance with IS 14893 including surface preparation of pile top by removing soil, mud, dust & chipping lean concrete lumps etc. and use of computerised equipment and high skill trained personal for conducting the test & submission of results, all complete as per direction of Engineer-in-charge. Note:- The inclusion of the above item in the schedule of work shall be judiciously decided by the technical sanctioning authority, keeping in view the quality control, type of soil strata & importance of the project. | 100 | per test | 1,120 ₹1,12,000 | 1,109 ₹1,10,900 Lowest |
| 1.01 | 2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil | 2,311.72 | cum | 290 ₹6,70,398.22 Lowest | 346 ₹7,99,854.43 |
| 1.01 | 2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil | 213.07 | cum | 330 ₹70,314.75 Lowest | 346 ₹73,723.95 |
| 1.01 | 2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil | 174.4 | cum | 125 ₹21,799.88 Lowest | 131 ₹22,846.27 |
Tender Value
Refer Docs
EMD Value
₹5 L
Closing Date
10 Dec 2025, 6:00 pmClosed
Managing Director
IMPACT Kerala Ltd
Civil, Electrical, Plumbing, Fire, ELV, HVAC, etc
2025_IKL_814408_2
IKL/BLDG/2025/2
Open Tender
Civil Works - Buildings
Item Rate
545 days
Ravipuram Campus, Kottarakkara
Please refer Tender documents.
6 documents required · 6 mandatory
₹19,600
Yes
₹5 L
Yes
2 Mar 2026
3 Dec 2025
12 Dec 2025
3 Dec 2025
10 Dec 2025
3 Dec 2025
Foundation & Basement
OD244948/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: No extra payment shall be made for extra cement in the design mix of the subdata): 700 mm dia piles
OD244951/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap). (Note: No extra payment will be made for extra cement in the design mix of subdata) - 800 mm dia piles
OD265270/2025-2026:Boring, providing and installation bored cast-in-situ reinforced cement concrete piles of grade M-30 of specified diameter and length below pile cap, to carry a safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of boring with bentonite solution and temporary casing of appropriate length for setting out and removal of same and the length of the pile to be embedded in the pile cap etc. by Crawler mounted, telescopic boom hydraulic pilling Rig all complete, including removal of excavated earth with all its lifts and leads (length of pile for payment shall be measured up to bottom of pile cap) (No extra payment shall be made for the design mix in the sub data). Note: Truck Mounted rotary/TMR/Tube well boring machine shall not be used:1000 mm dia piles
20.6.2.1:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityInitial test (Test Load 2.5 times the Safe capacity)
20.6.2.2:Vertical load testing of piles in accordance with IS 2911 (Part IV) including installation of loading platform by Kentledge/Anchor piles method and preparation of pile head or construction of test cap and dismantling of test cap after test etc. complete as per specification & the direction of Engineer in-charge. Single pile above 50 tonne and upto 100 tonne capacityRoutine test (Test Load 1.5 times the Safe capacity)
2.6.1:Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5 m, as directed by Engineer-in-charge.All kinds of soil
2.8.1:Earth work in excavation by mechanical means (Hydraulic excavator) /manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift up to 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil
2.26.1:Extra for every additional lift 1.5 m or part there of in excavation / banking excavated or stacked materials.All kinds of soil
22.23.1:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineerin-charge. The product performance shall carry guarantee for 10 years against any leakage.For vertical surface two coats @0.70 kg per sqm
22.23.2:Providing and applying integral crystalline slurry of hydrophilic in nature for waterproofing treatment to the RCC structures like retaining walls of the basement, water tanks, roof slabs, podiums, reservior, sewage & water treatment plant, tunnels / subway and bridge deck etc., prepared by mixing in the ratio of 5 : 2 (5 parts integral crystalline slurry : 2 parts water) for vertical surfaces and 3 : 1 (3 parts integral crystalline slurry : 1 part water) for horizontal surfaces and applying the same from negative (internal) side with the help of synthetic fiber brush. The material shall meet the requirements as specified in ACI-212-3R-2010 i.e by reducing permeability of concrete by more than 90% compared with control concrete as per DIN 1048 and resistant to 16 bar hydrostatic pressure on negative side. The crystalline slurry shall be capable of self-healing of cracks up to a width of 0.50mm. The work shall be carried out all complete as per specification and the direction of the engineer-in- charge. The product performance shall carry guarantee for 10 years against any leakage.For horizontal surface one coat @1.10 kg per sqm.
4.1.5:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources : 6 graded stone aggregate 20 mm nominal size derived from natural sources)
4.1.8:Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level:1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources)
5.1.2:Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:1:1:5:3 (1 cement 1.5 coarse sand :3 graded stone aggregate 20 mm nominal size derived from natural sources)
5.9.1:Centering and shuttering including strutting, etc. and removal of form for:Foundations, footings, bases of columns, etc for mass concrete
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.2:Centering and shuttering including strutting, etc. and removal of form for:Walls (any thickness) including attached pilasters, butteresses, plinth and string courses etc.
5.22.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete upto plinth levelThermo - Mechanically Treated bars of grade Fe-500D or more
OD244953/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-60 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge - All works below Plinth level (Note:- Cement content is taken as 430 kg/cum. No extra payment will be made for excess cement).
OD244949/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-40 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Cement content is taken as 390 kg/cum. No extra payment will be made for excess cement).
OD244952/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge. (Note:- Cement content is taken as 350 kg/cum. No extra payment will be made for excess cement).
50.6.1.4:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for foundation and plinth with thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand ) etc complete
7.1.1:Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1:6 (1 cement : 6 coarse sand)
Superstructure
5.3:Reinforced cement concrete work in beams, suspended floors, roofs, having slope up to 15° landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases up to floor five level excluding the cost of centering, shuttering, finishing and reinforcement, with1:1.5:3 (1 cement : 1.5 coarse sand (Zone III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources).
5.9.3:Centering and shuttering including strutting, etc. and removal of form for:Suspended floors, roofs, landings, balconies and access platform
5.9.5:Centering and shuttering including strutting, etc. and removal of form for:Lintels, beams, plinth beams, girders bressumers and cantilevers
5.9.6:Centering and shuttering including strutting, etc. and removal of form for:Columns, Pillars, Piers, Abutments, Posts and Struts
5.9.7:Centering and shuttering including strutting, etc. and removal of form for:Stairs, (excluding landings ) except spiral - staircases)
OD244957/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-60 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge - All works above plinth level. (Note:- Cement content is taken as 430 kg/cum. No extra payment will be made for excess cement)
OD244958/2025-2026:Providing and laying in position machine batched and machine mixed design mix M-30 grade cement concrete for reinforced cement concrete work, using cement content as per approved design mix, including pumping of concrete to site of laying but excluding the cost of centering, shuttering, finishing and reinforcement, including admixtures in recommended proportions as per IS: 9103 to accelerate, retard setting of concrete, improve workability without impairing strength and durability as per direction of Engineer - in-charge - All works above plinth level. (Note:- Cement content is taken as 350 kg/cum. No extra payment will be made for excess cement)
5.22A.6:Steel reinforcement for R.C.C work including straightening, cutting, bending, placing in position and binding all complete above plinth level.Thermo - Mechanically Treated bars of grade Fe-500D or more
50.6.3.2:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost of scaffolding complete
OD244955/2025-2026:Solid block masonry using pre cast solid blocks (Factory made) of size 40x20x10 cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor 2 level up to floor V level for 10 cm thick wall in : CM 1:6 ( 1 cement : 6 coarse sand) including cost
of scaffolding complete (Based on 50.6.2)
50.6.2.2:Solid masonry using pre cast solid blocks (factory made) of size 30x20x15cm or nearest available size confirming to IS 2185 part I of 1979 for super structure up to floor two level with thickness 15cm in : CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.5:Solid block masonry using pre cast solid blocks ( Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 Part I of 1979 for super structure up to floor two level thickness 20cm and above in: CM 1:6 ( 1 cement : 6 coarse sand) etc complete
50.6.1.6:Solid block masonry using pre cast solid blocks (Factory made) of size 30x20x20cm or nearest available size confirming to IS 2185 part I of 1979 for super structure above floor two level upto floor five level thickness 20cm and above in : CM 1:6 ( 1 cement : 6 coarse sand sand) etc complete
22.5:Providing and laying water proofing treatment in sunken portion of WCs, bathroom etc., by applying cement slurry mixed with water proofing cement compound consisting of applying : a) First layer of slurry of cement @ 0.488 kg/sqm mixed with water proofing cement compound @ 0.253 kg/sqm. This layer will be allowed to air cure for 4 hours. b) Second layer of slurry of cement @ 0.242 kg /sqm mixed with water proofing cement compound @ 0.126 kg/ sqm. This layer will be allowed to air cure for 4 hours followed with water curing for 48 hours. The rate includes preparation of surface, treatment and sealing of all joints, corners, junctions of pipes and masonry with polymer mixed slurry.
13.1.1:12 mm cement plaster of mix:1:4 ( 1 cement : 4 fine sand)
13.16.1:6 mm cement plaster of mix:1:3 ( 1 cement : 3 fine sand)
13.46.1:Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/10 sqm)
13.83.2:Wall painting with premium acrylic emulsion paint of interior grade, having VOC (Volatile including applying additional coats wherever required to achieve even shade and colour.Two coats
13.85.3:Applying priming coats with primer of approved brand and manufacture, having low VOC ( Volatile Organic Compound) content.With water thinnable cement primer on walls surface having VOC content less than 50 grams / litre
13.80:Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.
11.41.2:Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20 mm thick cement mortar 1:4(1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete.Size of Tile 600 x 600 mm.
11.46.2:Providing and laying Vitrified tiles indifferent sizes (thickness to be specified by manufacturer), with water absorption less than 0.08 % and conforming to I.S. 15622, of approved make, in all colours & shade, in skirting, riser of steps, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand), including grouting the joint with white cement & matching pigments etc. complete.Size of Tile 600x600 mm
11.48.2:Grouting the joints of flooring tiles having joints of 3 mm width, using epoxy grout mix 0.70 kg of organic coated filler of desired shade (0.10 kg of hardener and 0.20 kg of resin per kg). including filling /grouting and finishing complete as per direction of Engineer-in-charge.Size of Tile 600x600 mm
itemH2Code25
8.31:Providing and fixing Ist quality ceramic glazed wall tiles conforming to IS: 15622 (thickness to be specified by the manufacturer), of approved make, in all colours, shades except burgundy, bottle green, black of any size as approved by Engineer-in- Charge, in skirting, risers of steps and dados, over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand) and jointing with grey cement slurry @ 3.3kg per sqm, including pointing in white cement mixed with pigment of matching shade complete.
itemH2Code26
itemH2Code27
11.21.1.1:Providing and fixing 10 mm thick acid and /or alkali resistant tiles of approved make and colour using acid and / or alkali resisting mortar bedding, and joints filled with acid and /or alkali resisting cement as per IS : 4457, complete as per the direction of Engineer-in-Charge. In flooring on a bed of 10 mm thick mortar 1:4 (1 acid proof cement : 4 coarse sand)Acid and alkali resistant tile
itemH2Code28
itemH2Code30
itemH2Code31
itemH30Code10
itemH2Code32
9.48.1:Providing and fixing M.S. Grills of required pattern in frames of windows etc. with M.S. flats, square or round bars etc. including priming coat with approved steel primer all complete.Fixed to steel windows by welding
9.117.1:Providing and fixing factory made uPVC door frame made of uPVC extruded sections having an overall dimension as below (tolerance ±1 mm), with wall thickness 2.0mm (±0.2 mm), corners of the door frame to be jointed with galvanized brackets and stainless steel screws, joints mitred and plastic welded. The hinge side vertical of the frames reinforced by galvanized M.S. tube of size 19 x 19 mm and 1 mm (± 0.1 mm) wall thickness and 3 nos. stainless steel hinges fixed to the frame complete as per manufacturer's specification and direction of Engineer-in-chargeExtruded section profile size 48x40 mm
9.118.1:Providing and fixing to existing door frames24 mm thick factory made PVC door shutters made of styles and rails of a uPVC hollow section of size 59x24 mm and wall thickness 2 mm (± 0.2 mm) with inbuilt edging on both sides. The styles and rails mitred and joint at the corners by means of M.S. galvanised/plastic brackets of size 75x220 mm having wall thickness 1.0 mm and stainless steel screws. The styles of the shutter reinforced by inserting galvanised M.S. tube of size 20x20 mm and 1 mm (± 0.1 mm) wall thickness. The lock rail made up of 'H' section, a uPVC hollow section of size 100x24 mm and 2 mm (± 0.2 mm) wall thickness,fixed to the shutter styles by means of plastic/galvanised M.S. 'U' cleats. The shutter frame filled with a uPVC multi-chambered single panel of size not less than 620 mm, having over all thickness of 20 mm and 1 mm (± 0.1 mm) wall thickness. The panels filled vertically and tie bar at two places by inserting horizontally 6 mm galvanised M.S. rod and fastened with nuts and washers, complete as per manufacturer's specification and direction of Engineer-in-charge( For W.C. and bathroom door shutter).
21.3.1:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 4.0 mm thickness (weight not less than 10kg/sqm)
25.8:Design supply & installation of suspended Spider Glazing system designed to withstand the wind pressure as per IS 875 (Part-III). The Suspended System held with Spider Fittings of SS-316 Grade Steel of approved manufacturer with glass panel having 12 mm thick clear toughened glass held together with SS- 316 Grade Stainless steel Spider & bolt assembly with laminated glass fins 21 mm thick. The Glass fins and glass panel assembly shall be connected to Slab/beams by means of SS- 316 Grade stainless steel brackets & Anchor bolts and at the bottom using SS channel of 50x25x2mm using fastener & anchor bolts, non staining weather sealants of approved make, Teflon/ nylon bushes and separators to prevent bi-metallic contacts, all complete to perform as per specification and approved drawings. The complete system to be designed to accommodate thermal expansion & seismic movements etc. The joints between glass panels (6 to 8 mm) and gaps at the perimeter & in U channel of the assembly to be filled with non staining weather sealant, so as to make the entire system fully water proof & dust proof. The rate shall include all design, Engineering and shop drawing including approval from structural designer, labour, T&P, scaffolding, other incidental charges including wastage, enabling temporary services all fitting fixers nut bolts, washer, Buffer plates, fastener, anchors, SS channel laminated glass etc. all complete. For the purpose of payment, actual elevation area of Glazing including thickness of joints and the portion of Glass panel inside the SS channel shall be measured.
21.1.1.2:Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS : 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminnium snap beading for glazing /paneling, C.P. brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge.(Glazing, paneling and dash fasteners to be paid for separately): For fixed portionPowder coated aluminium (minimum thickness of powder coating 50 micron)
21.1.2.2:For shutters of doors, windows & ventilators including providing and fixing hinges / pivots and making provision for fixing of fittings wherever required including the cost of EPDM rubber/ neoprene gasket required (Fittings shall be paid for separately)Powder coated aluminium (minimum thickness of powder coating 50 micron)
21.3.2:Providing and fixing glazing in aluminium door, window, ventilator shutters and partitions etc. with EPDM rubber / neoprene gasket etc. complete as per the architectural drawings and the directions of Engineer - in -Charge. ( Cost of aluminium snap beading shall be paid in basic item):With float glass panes of 5.50 mm thickness (weight not less than 12.50 kg/sqm)
itemH2Code41
21.2.1:Providing and fixing 12 mm thick prelaminated particle board flat pressed three layer or graded wood particle board conforming to IS : 12823 Grade I Type II, in panelling fixed in aluminum doors, windows shutters and partition frames with C.P. brass / stainless steel screws etc. complete as per architectural drawings and directions of Engineer - in- Charge.Pre-laminated particle board with decorative lamination on one side and balancing lamination on other side
itemH2Code43
9.82:Providing and fixing bright finished brass hanging type floor door stopper with necessary screws, etc. complete.
9.88:Providing and fixing chromium plated brass 100 mm mortice latch and lock with 6 levers and a pair of lever handles of approved quality with necessary screws etc. complete.
9.92.1:Providing and fixing chromium plated brass handles with necessary screws etc. complete:125 mm
50.9.1.1:Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required dia & length (hold fast lugs or dash fastener shall be paid for separately), using good quality Anjili wood /jack wood
50.9.2.1:Providing and fixing paneled and glazed shutters for doors, windows and clerestory windows, 35 mm thick shutters including ISI marked M.S. pressed butt hinges bright finished of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineerin - charge using Anjili/ Jack wood
50.9.4.1:Providing and fixing paneling or paneling and glazing in paneled o
9.53:Providing 40x5 mm flat iron hold fast 40 cm long including fixing to frame with 10 mm diameter bolts, nuts and wooden plugs and embeddings in cement concrete block 30x10x15 cm 1:3:6 mix ( 1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size)
itemH2Code51
9.55.1:Providing and fixing ISI marked IS : 1341 M.S. pressed butt hinges bright finished with necessary screws etc. complete :125x65x2.12 mm
itemH2Code52
itemH30Code11
OD244956/2025-2026:Providing and fixing polycarbonate profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 0.50 mm (+0.05%), total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in-charge. The sheet shall be fixed using self drilling/self tapping screws of size (5.5x55mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. (Modified 12.8)
itemH2Code56
itemH2Code57
itemH2Code58
itemH2Code59
itemH3Code2
itemH3Code3
itemH3Code4
17.78:Providing and fixing white vitreous china extended wall mounting water closet of size 780x370x690 mm of approved shape including providing & fixing white vitreous china cistern with dual flush fitting, of flushing capacity 3 litre/6 litre (adjustable to 4 litre /8 litres), including seat cover, and cistern fittings, nuts bolts and gasket etc complete.
OD302310/2025-2026:Supplying, installing, testing & commissioning at site sanitary fixtures for handicapped toilet including one number white vitreous china floor mounted water closet with soft close seat cover and cistern, wash basin, one pair mounting brackets, one number elbow operated pillar cock and all other related fittings like waste coupling, one number hinged rail, 76 cm long & 4 sets of of grab rails, each of 60cm long etc designed for people with special needs comes with as per manufactures specification including cutting and making good the walls and floors wherever required as per drawing and as directed by Engineer in charge
17.7.4:Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern, including painting of fittings and brackets, cutting and making good the walls wherever require:White Vitreous China Flat back wash basin size 550x 400 mm with single 15 mm C.P. brass pillar tap
itemH3Code5
18.56.2:Providing and fixing PTMT pillar cock of approved quality and colour.15 mm nominal bore, 125 mm long foam flow, weighing not less than 120 gms
18.53.1:Providing and fixing C.P. brass angle valve for basin mixer and geyser points of approved quality conforming to IS: 893115 mm nom
itemH3Code7
17.71:Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall of standard shape with bracket of the same materials with snap fittings of approved quality and colour, weighing not less than 105 gms
50.17.1.2:Supplying and fixing CP Towel rod 45cm or nearest available length including cost of materials and labour charges etc complete as per the direction of site Engineer-in-charge.
itemH3Code11
18.55.2:Providing and fixing PTMT stop cock of approved quality and colour.20 mm nominal bore, 89 mm long, weighing not less than 88 gms
itemH3Code13
18.58.1.2:Providing and fixing PTMT grating of approved quality and colour. Circular type125 mm nominal dia with 25 mm waste hole
17.31:Providing and fixing 600x450 mm beveled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete.
itemH3Code15
50.18.8.5.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. concealed work, including cutting chases and making good the wall etc. 40 mm pipe 10 kgf/ cm2
50.18.8.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 50 mm pipe 10 kgf/cm2
50.18.7.4.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 32 mm dia 10Kgf/cm2- Internal work - Exposed on wall
50.18.7.6.1:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 50 mm dia 10 Kfg/cm - Internal work- Exposed on wall
itemH3Code20
50.18.7.3.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step PVC solvent cement and testing of joints complete as per direction of Engineer-in-Charge 25 mm dia 10Kgf/ cm2- Internal work- Exposed on wall
itemH3Code22
18.28.2:Providing lead caulked joints to spun iron or C.I pipes and specials including testing of joints but excluding the cost of pig lead:125 mm diameter pipe
18.18.3:Providing and fixing ball valve (brass) of approved quality, High or low pressure, with plastic floats complete:25 mm nominal bore
itemH3Code25
18.16.2:Providing and fixing brass stop cock of approved quality :20 mm nominal bore
50.18.9.6.1:Providing and fixing PVC pipes includings jointing of pipes with one step PVC solvent cement, trenching, refilling & testing of joints complete as per direction of Engineer in Charge. 50 mm dia 10Kgf/cm2
itemH3Code27
50.18.9.10.1:Providing and fixing PVC pipes includings jointing of pipes with one step pvc solvent cement, trenching , refilling & testing of joints complete as per direction of Engineer in Charge. 150 mm dia 6 Kgf/cm2
itemH3Code29
itemH3Code30
itemH3Code31
50.18.8.9.2:Providing and fixing PVC pipes, fittings including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes with one step PVC Solvent cement and testing of joints complete as per direction of Engineer-in-Charge. Concealed work, including cutting chases and making good the wall etc. 110 mm pipe 4 kgf/cm2
19.16:Providing orange colour safety foot rest of minimum 6 mm thick plastic encapsulated as per IS: 10910 on 12 mm dia steeel bar conforming to IS:1786, having minimum cross section as 23 mm x 25 mm and over all minimum length 263 mm and width as 165 mm with minimum 112 mm space between protruded legs having 2 mm tread on top surface by ribbing or chequering besides necessary and adequate anchoring projections on tail length on 138 mm as per standard drawing and suitable to with stand the bend test and chemical resistance test as per specifications and having manufactures permanent identification mark to be visible even after fixing including fixing in manholes with 30x20x15 cm cement concrete block 1:3:6 ( 1cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) Complete as per design
18.33.1:Constructing masonry chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement:4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix ( 1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size), i/c necessary excavation, foundation concrete 1:5:10 ( 1 cement : 5 fine sand: 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 ( 1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design:With common burnt clay F.P.S (non modular) bricks of class designation 7.5
19.4.2.1:150x100 mm size P typeWith common burnt clay F.P.S. (non modular) bricks of class designation 7.5
18.19.2.2:Providing and fixing gun metal non-return valve of approved quality (screwed end): 32 mm nominal boreVertical
18.19.3.2:Providing and fixing gun metal non-return valve of approved quality (screwed end): 40 mm nominal boreVertical
18.19.4.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 50 mm nominal boreHorizontal
18.19.5.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 65 mm nominal
boreHorizontal
18.17.5:Providing and fixing gun metal gate valve with C.I. wheel of approved quality (screwed end) :65 mm nominal bore
18.19.6.1:Providing and fixing gun metal non-return valve of approved quality (screwed end): 80 mm nominal boreHorizontal
18.19.6.2:Providing and fixing gun metal non-return valve of approved quality (screwed end): 80 mm nominal boreVertical
itemH3Code40
itemH3Code41
itemH3Code42
itemH3Code43
itemH3Code44
50.18.9.21.8:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement -75 mm dia End cap
50.18.9.22.1:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110 mm dia Elbow
50.18.9.22.10:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement -110 mm dia End Cap
50.18.9.22.12:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x75 mm dia Reducer
50.18.9.22.3:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement-110 mm dia Door Elbow
50.18.9.22.4:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes, including jointing with PVC solvent cement- 110 mm dia Bend
50.18.9.22.5:Providing and fixing PVC moulded fittings/ accessories for Rigid PVC pipes including jointing with PVC solvent cement 110x110x110 mm dia Tee
50.18.9.22.6:Providing and fixing PVC moulded fittings/accessories for Rigid PVC pipes, including jointing with PVC solvent cement - 110x110x110 mm dia Door tee
OD315952/2025-2026:Supply, installation, testing and commissioning of Sewage Treatment Plant (MBBR Type) of 10KLD capacity with Ultra Filter. The work is inclusive of FRP tanks, all necessary Plumbing and Electrical works including electrical control panel, Cabling work with all accessories required for complete installation as per the detailed technical specifications.
OD315960/2025-2026:Making holes in RCC slabs floors, using core cutting machine, for laying pipes with standard clearance and rendering the same in RCC M20, including nominal reinforcement wherever required, complete. The quoted rate shall also include water proofing compound (ConbextraGP-2/GP-10) for complete sealing the same joints around the pipes for full depth etc to the satisfaction of the Project Manager including supply of all materials. RCC slabs (For Wash Basin, EWC & Floor Trap) 130 mm thick -For 110 mm dia.
itemH3Code59
itemH3Code62
itemH3Code60
itemH3Code61
1.55.3:Wiring for group controlled (looped) light point/fan point/exhaust fan point/ call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit, and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.Group C
1.10.3:Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLS PVC insulated copper conductor single core cable etc as required.Group C
point
OD245351/2025-2026:Wiringforstaircaselightpointswith2.5sq.mmFRLSPVCinsulatedcopperconductorsinglecorecableinandincludingsurface/recessedmediumclassPVCconduitandallaccessoriesrequiredforcompleteinstallationetc,with1waymodularswitch,modularplate,suitableGIboxmediumclassPVCconduitandallaccessoriesrequiredetcandearthingthepointwith2.5sq.mmFRLSPVCinsulatedcopperconductorsinglecorecableetcasrequiredandinstructedbyengineerincharge/consultant.(Note-Staircase light point shall be controlled by a single switch located inside fire control room in ground floor as per
latest fire norms) 4.02 Loop wiring for Light point
1.14.1:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2x1.5 sq.mm + 1x1.5 sq.mm earth wire
itemH4Code7
itemH4Code8
itemH4Code9
1.14.2:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire
1.14.3:Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface / recessed medium class PVC conduit as required2 X 4 sq. mm + 1 X 4 sq. mm earth wire
1.21.1:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm
1.21.2:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.25 mm
1.21.3:Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.32 mm
OD272634/2025-2026:PVCFLEXIBLECONDUIT-SupplyandclampingthefollowingsizeofcorrugatedpvcflexibleconduitwithnecessarylockingringandchecknutatterminationpointedusingsuitablesizeGI/paintedMSsaddlesspacingnotexceeding60cmsonsurfaceincludingmakinggood the damages, colour washing etc.as required. 20mm dia
OD272649/2025-2026:PVCFLEXIBLECONDUIT-SupplyandclampingthefollowingsizeofcorrugatedpvcflexibleconduitwithnecessarylockingringandchecknutatterminationpointedusingsuitablesizeGI/paintedMSsaddlesspacingnotexceeding60cmsonsurfaceincludingmakinggood the damages, colour washing etc.as required 25mm
OD272657/2025-2026:PVCFLEXIBLECONDUIT-SupplyandclampingthefollowingsizeofcorrugatedpvcflexibleconduitwithnecessarylockingringandchecknutatterminationpointedusingsuitablesizeGI/paintedMSsaddlesspacingnotexceeding60cmsonsurfaceincludingmakinggood the damages, colour washing etc.as required 32mm
OD272687/2025-2026:PVCFLEXIBLECONDUIT-SupplyandclampingthefollowingsizeofcorrugatedpvcflexibleconduitwithnecessarylockingringandchecknutatterminationpointedusingsuitablesizeGI/paintedMSsaddlesspacingnotexceeding60cmsonsurfaceincludingmakinggood the damages, colour washing etc.as required 40mm dia
1.25:Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required.
1.26:Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required.
1.31:Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 amps modular switch, connection etc. as required. (For light plugs to be used in non residential buildings).
90.11.1.11:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43)
90.11.1.13:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required12 way (8+36) - three phase double cover (IP 42/43)
OD245353/2025-2026:POP-UPBOX-Wiringforpopupboxsuitableforfixing2No6Asocketwithswitch&1Noofnetworkpointfixedinrecessusing1.5sq.mmFRLSPVCinsulatedcoppersinglecorestrandedwireandearthingusingusing1.5SqmmFRLSPVCinsulatedcoppersinglecorestrandedwire,greencolourcontinuousrunthoroughexistingfloortrunkingandthroughPVCflexibleconduitfromtrunkingearthingetcandalsoincludingUTPCAT6socketfornetworkpointincludingallaccessoriesasrequiredforcompleteinstallationbutexcludingCat6cableandcircuitmainasdirectedbyengineerinchargeandmakinggoodalldamagesmadeforinstallation.(Cost inclusive of approved make Pop-up box with two 6A socket and data point I/O and flexible wire for 6A socket and PVC flexible conduit)
1.33:Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden block including connection etc as required.
1.41:Installation, testing and commissioning of pre - wired, fluorescent fitting/ compact fluorescent fitting of all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required.
1.44:Installation, testing and commissioning of ceiling fan, including wiring the down rods of standard length (upto 30 cm) with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable etc. as required.
Distribution Boards
itemH5
90.11.1.10:Supply and installation of sheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/ isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required4 way (8+12) - three phase double cover (IP 42/43)
itemH5Code3
itemH5Code6
itemH5Code7
itemH5Code9
itemH6Code1
OD245460/2025-2026:Supplyandinstallationofperforatedcabletrayswithhorizontalandverticalbends,reducers,tees,crossovers,suitablesupports,brackets,andothernecessaryaccessoriesincompliancewithIEC61537:2023.ThetrayshallbegalvanizedforcorrosionprotectioninaccordancewithDINENISO1461:2023.Thetraysmustbetestedforamaximumsafeworkingloadof150kgwithaspanof1.5meters,ensuringdeflectionremainswithinstandardlimits.Thesafetyfactorshouldbe1.7timesthesafeworkingload.Theperforatedtrayshall be supplied in a standard length of 3 meters. Make: OBO Bettermann or equivalent.50 mm width X 60mm Height
itemH6Code2
MV Cable Supply, Laying & End Termination
itemH4Code17
itemH4Code18
itemH4Code19
itemH4Code20
OD245431/2025-2026:Supplyofthefollowingsize1.1kVgradeXLPEinsulatedPVCsheathed,armouredAluminiumconductorpowercableconfirmingtoIS7098 (part 1) amended up to date.4C X 10 Sq.mm Al Cable
OD245428/2025-2026:Supplyofthefollowingsize1.1kVgradeXLPEinsulatedPVCsheathed,armouredAluminiumconductorpowercableconfirmingtoIS7098 (part 1) amended up to date.2C X 6 Sq.mm Al Cable
itemH7Code6
itemH7Code8
itemH7Code9
itemH7Code10
itemH7Code11
itemH7Code12
itemH7Code13
itemH7Code14
7.8.2:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp)
7.8.3:Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp)
itemH7Code17
itemH7Code18
9.1.26:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 150 sq. mm (50mm)
9.1.23:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 70 sq. mm (38mm)
9.1.22:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2 X 50 sq. mm (35mm)
itemH7Code19
9.1.21:Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3 1/2X 35 sq. mm (32mm)
itemH7Code21
itemH7Code22
itemH7Code25
OD280609/2025-2026:Supplyingandfixing40Ato63Arating,240/415V,10kA,“C”curve,miniaturecircuitbreakersuitableforinductiveloadoffollowing poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Four pole
itemH7Code27
itemH7Code28
MCB, RCBO, MCCB & ISOLATORS
2.10.1:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole
itemH8
itemH8Code1
Heating Ventilation & Air-Conditioning (HVAC) System-VENTILATION SYSTEM
2.10.3:Supplying and fixing 5A to 32 A rating, 240/415 volts, 10 kA, ""C"" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Double pole
itemH8Code2
2.11:Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required.
OD245395/2025-2026:RCBO:Supplying,fixing,testingandcommissioningfollowingfourpoleanddoublepole,415voltsand240volts,residualcurrentcircuitbreakerwithoverloadprotection(RCBO)ofthefollowingratingandsensitivitycurrentintheexistingMCBSPNandTPNhorizontal/vertical DB's complete with connections, etc. as required and instructed by engineer in charge/consultant.32A 100mA FP RCBO
OD245399/2025-2026:MCCB:Supply,fixing,testingandcommissioningoffollowingrating,breakingcapacityandpole,ThermalMagneticReleasetypeMCCBinexistingVerticalDistributionBoardwithspreaderlinks,terminalconnectionsandallaccessoriesasrequiredmakingallnecessaryconnections etc as required and instructed by engineer in charge/consultant. 40 16 kA FP MCCB
OD245394/2025-2026:IsolatorWithEnclosure-SupplyandfixingoffollowingDP/FP230V/415V,isolatorsinsheetsteelpowdercoatedenclosurewithdoorinterlockfacilityonsurfaceconfirmingtoIEC60947-3completewithallaccessories,connections,testingandcommissioningetcasrequired and as instructed by engineer in charge also making good any damages made during installation63A - 80A FP Isolator with enclosure
itemH9
itemH9Code1
OD245472/2025-2026:Supply,installation,testingandcommissioningof3phase,415V,0.8PF50HzradiatorcooledDGsetoftherating82.5kVAPrimeDutyDieselGeneratorSetcomprisingofdieselenginealternator,fueltank,startingsystem,battery,batterycharger,electronicgovernoretcwithallaccessoriesrequiredforsynchronisingtheDGwithanotherDG's.ThebatterychargerofauxiliaryDCpowersupplyunit,withdrybatterieswithconnectingleadsandterminalswithstationarytype,highdischargeperformance,ValveRegulatedLeadAcid(VRLA)sealedmaintenancefree,batterychargerincludingallotheraccessorieslikeinterconnectingcablesetcasrequiredforcompleteinstallation.TheGeneratorsetshallhaveaintegraltypeacousticenclosureasperthelatestCPCBnorms.Dieselengineshallbe suitable for continuous operation of generator set and satisfies with EURO-II specifications
OD245471/2025-2026:EXHAUSTPIPES-Supplyingandfixingexhaustgaspipingofsuitabledia,weldedblackM.Sclass'B'pipeconfirmingtoIS:3589cuttorequiredlengthsandinstalledwithnecessarybends,supportsandclamps,anti-vibrationmountings,insulationofexhaustsystemwithmineralWool/Rockwool,50mmthickwiremesh&aluminiumcladdingetc.afterapplyingonecoatHRpaintaspermanufacturerrecommendation,asrequiredasperspecifications.suitableraincapfortoptoavoidrainwaterentry.Thedistancebetweenexhaustpipeattopandraincapshouldbehigherthandiameterofpipe.Horizontalrunofexhaustpipingshouldslopedownwardsawayfromenginetothecondensatetrap.Silencershouldbeinstalledwithdrainplugatbottom.Fixingshallbedonewithproperclamps,expansionbolts,andallotheraccessoriesasinstructedbytheEngineerandtherateinclusiveofallminorcivilworksrequired,bolts,clampsetcasrequiredforinstallation.Supporttoexhaustpipingshouldbedoneinsuchamannerthatloadofexhaustpipingisnotexertedtoturbochargerandtheverticalrunofthepipesshallbeprovidedwithindirectsupportingmethodsothatwhenthepipesarehotandexpandedtheywillbeliftedintothesupports.Exhaustpipeheightshallbe3mmorethanthetopofanyadjacentbuildingwithing 10m radius of the exhaust. For 82.5 kVA DG Set
itemH9Code2
LT Panels
, TP+NL TM Based MCCB - 1 Nos. 125A FP Isolator - 1 No 40 A FP MCB ISOLATOR-1 No. Supply, Installation, Testing and Commissioning
OD245453/2025-2026:STREET LIGHT PANEL Fabrication,supply,erection,testing,andcommissioningofacubicle-type,dustandvermin-proof,floor-mounted,front-operatedMVMainPanelBoard,madefrom14SWGthickCRCAsheetwithan11-tanktreatment,fullycompartmentalizedandconstructedtoaminimumofForm4A.ThepanelshallhaveaprotectionratingofIP-54fordustandwateringressandanimpactprotectionratingofIK09.Itshallincludehingedandearthedfrontdoors,anameplate,dangernoticeboard,heavy-dutyrubbergaskets,andremovablegland plates made from 3mm thick sheet steel. All components shall be as shown in the schematic drawing, and all opening parts of the panel shall be sealable to ensure proper protection against environmental and operational hazards. Incomer - 25A,10kA FP MCB - 1No. 40A, 415V, 25 kA best conductivity Al TPN bus bar with SMC supports, heat shrinkable sleeves etc complete as required. RYB phase indicating LED lamps with control fuses and switches - 1 set. DigitalTimeSwitchwithAstronomicalfunction:DigitalTime-switchwithAstronomicalfunctionForswitchingon/offlightsandotherelectricdevicesaccordingtotherising/settingofthesun.Dailyastronomicalcalculationofthesunrise/sunsettimesbasedontheentered location or location coordinates etc. with suitable connection as required Outgoing 6 - 32 A, TP MCB - 4 Nos. 6 - 32 A, FP Contactor - 3 Nos.
2.21:Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required.
Light and Fan Fixtures
itemH11
itemH11Code1
OD245332/2025-2026:Supply of linear surface-mounted LED batten with luminous efficacy of up to100 lumens per watt. The system wattage shall not exceed 20W,and the luminaire must have a rated system lifetime of 50,000 burning hours. It should feature a color temperature of 5700K and a Color Rendering Index(CRI) greater than 80.The driver of the luminaires hall have a Total Harmonic Distortion(THD) of less than10% and a Power Factor(PF)greaterthan0.95.The housing shall be made from high-efficiency extruded aluminum with a polycarbonate diffuser for uniform light distribution. The design should be similar to Wipro Make Model No:LL24-251-XXX-57-XX or equivalent.
OD245336/2025-2026:Supplyof9WRecessedmountedroundLEDDownlighterhighefficiencywithanominalsystemlumenoutputof300lumens.Luminairewattageshouldnotexceed9W.Theluminaireshouldhavea CRI>80.DriveroftheluminaireshallhaveTHD<20%andPF>0.9.TheheatsinkshouldbemadeofdiecastaluminiumandtheluminaireopticsshallhaveahighefficiencyPCdiffuser.SimilartoWipromakeModelNo: LD06-111-XXX-57-XX or equivalent.
OD245331/2025-2026:Supplyof12WRecessedmountedroundLEDDownlighter,highefficiencywithanominalsystemlumenoutputof300lumens.Luminairewattageshouldnotexceed12W.Theluminaireshouldhavea CRI>80.DriveroftheluminaireshallhaveTHD<20%andPF>0.9.TheheatsinkshouldbemadeofdiecastaluminiumandtheluminaireopticsshallhaveahighefficiencyPCdiffuser.SimilartoWipro make Model No:LD90-111-XXX-65-XX* or equivalent.
OD245333/2025-2026:Supplyof15WRecessedmountedroundLEDDownlighter,highefficiencywithanominalsystemlumenoutputof1800lumens.Luminairewattageshouldnotexceed15W.Theluminaireshouldhavea CRI>80.DriveroftheluminaireshallhaveTHD<20%andPF>0.9.TheheatsinkshouldbemadeofdiecastaluminiumandtheluminaireopticsshallhaveahighefficiencyPCdiffuser.SimilartoWipro make Model No: LD06-171-XXX-57-XX** or equivalent.
OD245339/2025-2026:Supplyof18W1X1LEDSQUARELIGHTwithanominalsystemlumenoutputof500lumensandaminimumsystemefficacyof2000lm/W.Theluminaireshallhavearatedsystemlifetimeof50,000burninghoursatL70.Theluminaireshouldhaveacolortemperatureof6000KandCRI>80.TheluminaireshallmeetIP54ratingwithTHD<10%andPF>0.9.Aestheticwhiterimmoldedinengineeredplastic.The total power consumption should not exceed18W. LED Shall be Similar to Wipro MakeLD81-131-XXX-60-SM or equivalent
OD245343/2025-2026:SupplyofMirrorLight,highefficiencywithanominalsystemlumenoutputof760lumens.Luminairewattageshouldnotexceed9W.Theluminaireshouldhavea CRI>80.DriveroftheluminaireshallhaveTHD<10%andPF>0.9.SlimLEDbatteninaluminiumhousinganddecorativeendcaps.Robustdriverwithwidevoltagerange100-240voltsandinbuiltprotection.AestheticallydesignedmirrorLEDlightfixtureof4000K,ofsurfacemountingwhichprovidessoft-lightandglarefreesymmetricalillumination.SimilartoModelnumberLIGHT LL24-541-XXX-57-CD of Wipro make or equivalent
OD245340/2025-2026:SupplyofLEDBulkHeadLuminairewithmaxwattageof10Wwithsystemlumensnotlessthan300Lumes.Theluminaireshallhavearatedsystemlifetimeof50,000burninghoursatL70.HousingshallbepressurediecastaluminiumwithIP65rating.luminaireshouldhaveacolortemperatureof5700KandCRI>80.Driveroftheluminaires
OD245334/2025-2026:SupplyofGateLightLuminairewithmaxwattageof30W.HousingshallbediecastaluminiumhousinginpurepolysterUVresistantpowdercoatedblackfinishwithHETPMMAdiffuserforuniformillumination,luminaireshouldhaveacolortemperatureof5700KandCRI>80. Similar to Wipro Make LP07-431-XXX-57-CL or Equivalent
OD245341/2025-2026:FAN FIXTURES:Supplyingofceilingfanof1200mm(48inch)EnergyEfficient5StarRatedHighSpeedBLDCCeilingFanwithRegulatortype,highspeed, including the down rod as per the site condition. Similar to atomberg ikano or equivalent
OD245338/2025-2026:Supply,installation,testingandcommissioningofexhaustfanofapprovedmake250mm(sweep size)BLDC motor Energy Saving Exhaust Fan (Black) as per the specification. Similar to atom Berg efficio or equivalent
itemH12
itemH12Code1
OD245345/2025-2026:30kVAUPS:Supply,installation,andcommissioningof30kVAUPSstandaloneConfiguration.3phaseinandout.withindoor(IP20)withsurgeprotectionsystemwith15Minbackupbattery@30kvaLoadMinimumVAH15600perUPSSMFbatteryofapprovedmake,Inputpf>0.99,InputTHDi<5%,doubleconversiontechnology,230V,50Hzsinglephase,output230V,50Hzsinglephase,Itshallbe100%generatorcompatible,withEfficiency>94%andoutputpowerfactorunity(30kVA=30kW),EcomodeEfficiency>96%andincludingallaccessoriesetcasrequired.Theacousticnoiseat1mofthesystemshouldbe<50dB.ThesystemshallcomplytoIEC/EN62040-1forSafety,EN/IEC62040-2forelectromagneticcompatibility,EN/IEC62040-3forPerformance,IEC62040-4forEnvironmentallyfriendly,CE,BIS,ROHS,Certificates,andrelevantISstandards.Thesystemshallbetrueonlinedouble-conversionDSPbasedUPSsystemandUPSshallbewithautomaticbypassbuilt-in.ThesystemshallhaveIGBTrectifierandinverter.warranty2years for UPS and batteries, open rack and interconnecting cables are considered for batteries.
Lightning and Earth Protection
itemH13
itemH13Code1
itemH32Code1
OD245314/2025-2026:LIGHTNING PROTECTION:Supply,installationandtestingof3meterairterminalwithaccessories,providingandfixingairterminalsasperIEC-62305part-316mmrodtaperedto10mmaluminiumrod:MeetsthetechnicalspecificationaccordingtoDINEN50164-2(VDE0815part202).MeetstherequirementofVDE0185/305(IEC62305)101VL4000:semi-hard(E-AlMgSiO5correspondstoDIN48801)Suitableforhighwindload.SystemconsistofFangFixwithbaseandclamponthetopairterminaliserected.Fangfixclampmadeofcablebracket,lightningtestedfor100KA10/350microsecwaveform.2nosof16KGstoneof365mmdiameter,highlevelofstability.Quickandeasymountingofinterceptionrodusinganchors.Concrete,frost-resistant,canbestacked,includingallaccessoriesasrequiredforcomplete installation as instructed by engineer in charge.
OD245319/2025-2026:Supplyandinstallationof8mmsolidaluminiumroundconductor:ForconcretebuildingMeetsthetechnicalspecificationaccordingtoDINEN50164-2(VDE0815part202).MeetstherequirementofVDE0185/305(IEC62305)RD8/ALU:semi-hard(E-AlMgSiO5correspondstoDIN48801)With50sq.mmcrosssectionalarea.PolyamideConductorholder:WithM8femalethreadordiameter7mm,M8Screwtoconnecttheconductorholder.Weatherandtemperatureresistantfrom-35to+90degreeCelsiustested.Conductorholder@1meterdistance, including all accessories as required for complete installation as instructed by engineer in charge. a) Vertical run- Down conductor
OD245313/2025-2026:Supplyandinstallationof8mmsolidaluminiumroundconductor:ForconcretebuildingMeetsthetechnicalspecificationaccordingtoDINEN50164-2(VDE0815part202).MeetstherequirementofVDE0185/305(IEC62305)RD8/ALU:semi-hard(E-AlMgSiO5correspondstoDIN48801)With50sq.mmcrosssectionalarea.PolyamideConductorholder:WithM8femalethreadordiameter7mm,M8Screwtoconnecttheconductorholder.Weatherandtemperatureresistantfrom-35to+90degreeCelsiustested.Conductorholder@1meterdistance, including all accessories as required for complete installation as instructed by engineer in charge. b) Horizontal run - Parapet application
OD245316/2025-2026:Supplyandinstallationof8mmsolidaluminiumroundconductor:ForTERRACEAPPLICATIONMeetsthetechnicalspecificationaccordingtoDINEN50164-2(VDE0815part202).MeetstherequirementofVDE0185/305(IEC62305)RD8/ALU:semi-hard(E-AlMgSiO5correspondstoDIN48801)With50sq.mmcrosssectionalarea.StainlesssteelbasewithPolyamideConductorholdertop:Adjustablewidthfrom185-260mm.Infinitelyadjustableconductorholder.Fastinstallationusingwingscrew.Bottomsectionwith8.5mmdiameterslotWithM8femalethreadordiameter7mm,M8Screwtoconnecttheconductorholder.Weatherandtemperatureresistantfrom -35 to +90 degree Celsius tested. Conductor holder @ 1 meter distance
OD245310/2025-2026:Supply and fixing of cross connector/T connector :to route vertical down conductor/mesh formation made of stainless steel/hotdippedgalvanisedironwithnecessaryscrewsetcasrequired.Installedwith4hexagonalboltsM8*25withM8hexagonalnutsandallaccessories as required for complete installation
OD245308/2025-2026:Supply and fixing of PVC trapezoidal 1.5m long ducts including the fastening clamps and all accessories as required.
OD245312/2025-2026:Providing and fixing of Cross connector for Flat: Suitable for 30mm Galvanised steel strip. Installed with 4 nos of hexagonal plate.
OD245320/2025-2026:SupplyandlayingthefollowingsizesofCustripslaid0.6mbelowgroundlevelincludingexcavatingtrenchofsuitablesizeandrefilling,includingnecessaryclampsandboltsetcandallaccessoriesasrequiredforcompleteinstallationasinstructedbyengineerincharge/consultants 25 X 3 Cu strips tinned at the joints
OD245307/2025-2026:Supplyandlayingthefollowingsizesofearthingbarecopper/stripsoncabletrayorwallsurface,includingnecessaryclamps(eachclamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.25 X 3 Cu strips tinned at the joints
OD245315/2025-2026:Supplyandlayingthefollowingsizesofearthingbarecopper/stripsoncabletrayorwallsurface,includingnecessaryclamps(eachclamp not exceeding 60 cm) and bolts etc as required for complete installation as instructed by engineer in charge/consultant.Copper wire No.8 SWG
Metering Cubicle with KWH meter
itemH14
itemH14Code1
OD245478/2025-2026:Fabrication,supply,erection,testingandcommissioningofcubicletype,dustandverminproof,wallmountedmeteriungcubiclemadeoutofCRCAsheetcompletewithhingedandearthedfrontdoorswithnameplate,heavydutyrubbergaskets,removableglandplatesincludingallaccessoriesrequiredforcompleteinstalationasperKSEBLstandard.Thefrontdoorshallbewithvisionpanel/glassfor meter reading and locking arrangement. All opening parts of the panel shall be sealable. Meter-ThreephaseLTenergy/TODmeterwithnecessaryaccessoriesrequiredforcompleteinstallation.Themetershallbetestedandaprovalshallbetakenfromtheconcerneddepartment(KSEBL)includingallaccessoriesrequiredforcompleteinstallationanditsconnections and inter connections etc - 1 Set - 200 A TP Cutout fuse unit with Neutral link - 1 Set - 200 A FP Isolator, handle operated type - 1 Set - Supply, Installation, testing and commissioning
Solar System
OD245455/2025-2026:15kWpGridTiedSolarPowerPlantwithThreePhaseSolarInverter:Supply,installation,testingandcommissioingof15kWpgridtiedsoalrpowerplantwithallnecessarymaterialsrequiredforcompleteinstallationaspertheapproveddrawingandasperthedetailedtechnicalSpecification.ThecostinclusiveofSolarPanels,Inverter,Panelmountwithallnecessaryframesandfabricationworks,panels&Distributionboards,Cables,wiresanditsconnections,necessaryearthingsystemwithallaccessoriesrequiredforcompleteinstalation including necessary approvals with KSEBL and KSEI and as directed by the engineer in charge
OD245467/2025-2026:SintexBox:Supply,installation,testingandcommissioningofSMCJunctionboxes,shockproof,rustproof,cableentryfrombottomorside, dimension(140x140x95). including all accesories as required for complete installation as instructed by engineer in charge.
OD245469/2025-2026:Supplyandfixingof4KgABCDryPowder(StoredPressure)TypeFireExtinguisher.pressurizedwithdrynitrogengasat15bar.Design,constructionandtestingasperIS2171-1999externalepoxypowdercoatingwithPORedShadeNo.538ofIS5,Suppliedwithstandardaccessories.
OD245466/2025-2026:Supply and providing First Aid Box.
OD245468/2025-2026:Supply and providing laminated First Aid chart duly framed and placed in a conspicuous location for clear vision.
OD245465/2025-2026:Supply & fixing Laminated drawings of electrical lay out, schematic drawing etc on good frame work.
OD245470/2025-2026:Supplyingandinstallingatapprovedlocationapprovedmakefirebucketsof24gaugegalvanizedsteelsheet,standard9litrecapacityandofroundbottomshape,paintedwhiteinsideandredoutsideandblackonthebottom,inscribedwithletters"FIRE"inblackandgold or , duly painted over a coat of primer. Cost inclusive of providing 3 Nos of fire bucks and MS stand frame
itemH16Code1
Fire Pipes, Valves & Accessories
itemH17
itemH17Code1
OD245484/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.25mm
OD245485/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.32mm
OD245499/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.40mm
OD245482/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.50 mm
OD245493/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.di
a.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.65mm
OD245495/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.80mm
OD245494/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.100mm
OD245502/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.150mm
OD245481/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.200mm
OD245492/2025-2026:Hydrant,SprinklerSystemandPlantRoom:Providing,fixing,pressuretestingandcommissioningofAboveGroundPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-IIwithallaccessoriessuchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,fixinginducts,onwalls,ceilingetc.byusingsuitableandstrongenoughsupportsasperrequirement,providinghighersizesofSleeves/Opening,whereverrequired,andclosingthegapbetweenthepipesandsleeves/openingsasperthedirectionofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapproved painting system as per technical specification.250mm
OD245479/2025-2026:Providing,fixing,pressuretestingandcommissioningofUndergroundFireProtectionPipeWorkwithHeavyDuty(Class-C)MildSteelPipes,confirmingtoIS:3589/1239Part-I(whereverapplicable)andwithHeavyDutyBlackDuctileIronScrewedFittingsforPipesupto50mm.dia.andButWeldedFittings,forpipesabove50mm.dia.confirmingtoIS:1239Part-II,suchastees,elbows,reducers,checknuts,unions,flanges,nipplesandneoprenegasket,bolts,nuts,washersetc.includingcutting,threading,welding,joining,layingintrenches,providingthrustblocks,providinghighersizesofProtectiveSleeve/PipesandRCCencasement,allasperrequirementandtotheapprovalofEngineer-in-Charge/Consultant.Thetotalpipeworkshallbeprotectedwithapprovedpainting systems and bitumen based flexible wrapping, all as per Technical Specifications.100mm
OD245488/2025-2026:Providing,fixing,testingandcommissioningofForgedBallValve,PN-16orabovegunmetal/castalloy,SS handle including necessary accessories and connections 25mm
OD245486/2025-2026:Providing,fixing,testingandcommissioningofButterflyValve,PN-16orabove,slimseal,standardleveroperatedtypeconfirmingto BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete.50 mm
OD245497/2025-2026:Providing,fixing,testingandcommissioningofButterflyValve,PN-16orabove,slimseal,standardleveroperatedtypeconfirmingto BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete80mm
OD245487/2025-2026:Providing,fixing,testingandcommissioningofButterflyValve,PN-16orabove,slimseal,standardleveroperatedtypeconfirmingto BS:5155 with IS: 13095 Mark, with required companion flanges, nuts, bolts etc. complete.250MM
OD245489/2025-2026:Providing,fixing,testingandcommissioningofNonReturnValve,WaferSwingChecktype,PN-16orabove,Vertical/HorizontalType , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete.80mm
OD245483/2025-2026:Providing,fixing,testingandcommissioningofNonReturnValve,WaferSwingChecktype,PN-16orabove,Vertical/Horizontal Type , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete.100 mm
OD245501/2025-2026:Providing,fixing,testingandcommissioningofNonReturnValve,WaferSwingChecktype,PN-16orabove,Vertical/HorizontalType , as per final requirement, conforming to IS: 13095 with nuts, bolts etc. complete.150mm
OD245490/2025-2026:Supply,installation,testingandcommissioningofHydraulicallyOperatedFireSprinklerAlarmValve(InstallationControlValve),GroovedEnd,ULListed/FMapproved,completewithConstantPressureTrimAssembly,WaterMotorGong,controlvalves,pressureswitch, pressure gauges etc. including all necessary fixing accessories 150mm
OD245500/2025-2026:Supply,installation,testingandcommissioningofAirReleaseValveGunmetal,conformingtoIS903:1993,havingrubberballwithsealing seat and with 25mm. BSP threaded male inlet, including necessary accessories and connections.
OD245498/2025-2026:ProvidingandfixingsightglassassemblyofbrassbodyandbrassballwithchromeplatedTest&dr
OD245503/2025-2026:Supply,installation,testingandcommissioningoffollowing4"dia.BourdonTypePressureGauge,withISIMarkorofequivalentInternational Standards. Weather / Water Proof Type Pressure Gauge with shut off cock and connection Pipe.
Fire Hose Reel & Hydrant Systems
itemH18Code1
itemH33Code1
itemH34Code1
itemH34Code4
itemH35Code1
itemH36
itemH36Code4
itemH36Code1
itemH36Code2
itemH36Code3
itemH36Code5
itemH37Code1
itemH38
itemH38Code1
itemH39
itemH39Code1
itemH13Code15
OD245321/2025-2026:EARTHING:Supply,installationandtestingof1200mmx1200mmx12mmCIplateelectrodeearthstationconformingtoIS:3043-1987/NEC/IEEcompletewithbrickmasonrychamber,CIcover,CIframe,GIwateringpipeof50mmdiawithfunnelhaving20GGIwiremeshetc.TheCIcoverframe/chambershallbeof1000mmx500mmx600mmsize.CImanholecoverwithframeshallbepaintedwithbitumasticpaint,identificationofearthpitwithyellowpaintbelowthechambercover,mixturesofcharcoal&commonsaltaroundelectrodeincludingdiggingofpituptopermanentmoisturelevelbutnotlessthan3metredepthandbackfilling.(valueofearthresistance should be less than 1 ohm )
OD245511/2025-2026:Providing,fixing,testingandcommissioningofTerracePump,HorizontalCentrifugalPump,Electricdriven,Capacity:900LPMat35Mtr.Head,suitableHPwithBronzeImpeller,SSShaft,MechanicalSeal,coupledtoHighEfficientIE-3RatedSquirrelGaugeInduction Electric Motor, 3ph, 2900/3000 RPM, TEFC, complete with base Plate.
OD245477/2025-2026:Providing,fixing,testingandcommissioningofStandardCoverage,QuickResponseAutomaticFireSprinkler,K-Factor:5.6(80Metric) with all accessories necessary for complete installation. The Fire Sprinklers shall be UL listed / FM Approved Upright Type, 68 Degree C Rating.
OD245476/2025-2026:Providing,Fixing,testingandcommissioningofFlowSwitch,with20BarWorkingPressureProtectionwithallnecessaryaccessories,formonitoringFireSprinklerSystem.ThecontrolcablingfromflowswitchestoFireSprinklerAnnunciatingPanelshallbemeasuredseparately.
itemH19Code2
Fire Pumps and Accessories
itemH20Code4
itemH20Code5
itemH20Code6
OD245329/2025-2026:Supply,&fixingoffollowingPortableFireExtinguisherasperBIS2190andBIS:15683:2006andwithrelevantISIStamping/ Marking. ABC Dry Powder, Propellant - Dry Nitrogen, Store Pressure Type - 4 Kg.
itemH21
itemH21Code1
itemH21Code2
itemH21Code3
Talk Back System
OD245410/2025-2026:Supply,installation,testingandcommissioningofPublicAddressspeakerwithtalkbackfacility6WattswithLMTandcallswitch,madeoutofpowdercoatedCRCAsheet,wallmountingtypeandtobeinstalledataheightofnotlessthan150CMfromthefinishedfloor levels, suitable for concealed mounting.
itemH22
itemH22Code1
itemH22Code2
Signages
itemH23
OD245405/2025-2026:SupplyandinstallinpositionfollowingSignBoardsmadeoutof3mmthick"Opaque"PVCfoamboardwithcomputercut,PVCnon-reflectiveselfadhesivevinylpaintedfoamboard,completewithmirrorfastenerswithallaccessoriesrequiredforcompleteinstallation as directed by the Engineer in charge. SignagePrinted"INCASEOFFIRE,USESTAIRSUNLESSINSTRUCTEDOTHERWISE"of1.25cm.heightlettersinredwithwhitebackground.Thesizeoftheboardshallbe25x30Cm.andshallbefixedattheheightof2Mts.fromfinishedfloornearManualPullStations.
17.2.9:INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of intelligent addressable thermal detector with rate of rise cum fixed tempreature thermistor complete with base as required.
17.2.15:INTELLIGENT FIRE ALARM SYSTEMSupplying, installation, testing & commissioning of addressable horn cum strobe complete as required.
OD245404/2025-2026:FloorIdentificationSignage(MAINSTAIRCASE,FIRESTAIRCASE,FIREASSEMBLYPOINT,PUMPROOM,FIRECONTROLROOM,ELECTRICALROOM,FIRELIFT,PASSENGERLIFTEtc.)ateachstairenclosureoneveryfloor,indicatingthefloornumberinwords,lettering size shall be 5 Cm. with contrasting colour from back ground. Size shall be 15cm x 30cm.
OD245406/2025-2026:SupplyandinstallinpositiontheSignage"FIREORDER"itshouldcontainthematterspecifiedinthetechnicaldetailson3mmthick"Opaque" PVC foam board of computerized cut, PVC non-reflective self adhesive vinyl painted foam board of 2' x 3'.
itemH23Code2
MISCELLANEOUS ITEMS
OD245414/2025-2026:fabrication,supply,andinstallationatsiteofHeavyDutyGalvanizedMildSteelPuddleFlange,fabricatedfromheavy-gradeM.S.pipe conforming to IS: 1239 (Part 1) or IS: 3589, with PN 20 drilled mild steel flanges as per BS-10 Table specifications, and M.S. plate, allaspertenderdrawingsandapprovedtechnicalspecifications.Aftercompletefabrication,thepuddleflangeshallbehot-dip galvanized as per IS:4759, and further coated with epoxy to the satisfaction and approval of the Engineer-in-Charge and Consultant.100 mm dia
OD245416/2025-2026:Supply,installation,testing&commissioningof2HourFireratedsteeldoorsetoffollowingsizeswithallaccessorieslikeballbearinghinges,Gasket,panicbar,firerated6mmclearvisionpanel,Doorcloser,etc.includingframeforthedoorasperthespecification required for complete installation.1000 X 2400 MM, Single Leaf with vision panel, Mortise sash lock, Lever handle, Surface Door closer
OD245413/2025-2026:Supply,installation,testing&commissioningof2HourFireratedsteeldoorsetoffollowingsizeswithallaccessorieslikeballbearinghinges,Gasket,panicbar,firerated6mmclearvisionpanel,Doorcloser,etc.includingframeforthedoorasperthespecification required for complete installation.1200 X 2400 MM, Single Leaf with vision panel, Mortise sash lock, Lever handle, Surface Door closer, etc.
OD245415/2025-2026:FIRESEALANTforallShafts-SupplyandFixingofloadbearingFirestopmortarsystemwithminimum2hoursfireratingwhentestedinaccordancewithUL1479standards,foropeningsinfloorsorslabsafterpassingservicelines.ThemortarshallbealightweightcementitiousproductandshallcarrytestcertificateinaccordancewithIEC60068-2-57:1999-11(EnvironmentalTesting)asperPart2-57:TestforVibration-Time-historymethodandVERTEQIIforseismiczone4.TheproductshallbeagetestedasperDafstbandDIBTstandards.Theproductshallcarrytestcertificateformoldresistanceratingof0asdeterminedbyASTMG21-96andshallhaveaVOCcontentofapprox.<1g/lasperLEED2009.Firestopinstallationshouldbedonebytrainedapplicators(HAFSC)andinaccordancewithmanufacturer'sguidelinesbyproviding10mmdiarebarsat200mmc/cbothwayswithchemicalanchoringalongthelengthandbreadthoftheshaftandprovide2layersofchickenmeshetc.Themortarshallbeappliedwithaminimumthicknessof65mm&havingloadbearingcapacityof200kg/sqm.Properengineeringjudgementneedstobesubmittedthroughthemanufacturer.Complete installation report through Software CFS DM shall also be submitted for inspection purpose.
itemH24
itemH24Code1
EXTRA LOW VOLTAGE SYSTEM-IP SURVEILLANCE SYSTEM
itemH25
OD245326/2025-2026:NetworkVideoRecorderwithStorage:Supply,installation,testingandcommissioningofFollowingChannelNetworkVideoRecorderwithRecordingStoragespaceserverfor30days,Supportscorrespondingchannels720Presolutionvideorecordingatrealtime,NVRONVIFsupporting,Recordingresolutionof4MPorabove,shouldsupportdualvideoHDMIoutput,H.265,H.264atrealtime.Videostorageexpansionforrecording,withallaccessoriesrequiredforcompleteinstallationanddirectedbyengineerincharge.(ConsiderthesufficientHDDsfor720p@20FPSfor30dayscontinuesrecordingforallchannels).Storagecalculationdetailsshallbesubmitted. 16 channels 720 P resolution
OD245327/2025-2026:NetworkVideoRecorderwithStorage:Supply,installation,testingandcommissioningofFollowingChannelNetworkVideoRecorderwithRecordingStoragespaceserverfor30days,Supportscorrespondingchannels720Presolutionvideorecordingatrealtime,NVRONVIFsupporting,Recordingresolutionof4MPorabove,shouldsupportdualvideoHDMIoutput,H.265,H.264atrealtime.Videostorageexpansionforrecording,withallaccessoriesrequiredforcompleteinstallationanddirectedbyengineerincharge.(ConsiderthesufficientHDDsfor720p@20FPSfor30dayscontinuesrecordingforallchannels).Storagecalculationdetailsshallbesubmitted.32 channels 720 P resolution
EXTRA LOW VOLTAGE SYSTEM-CLIENT MONITORING SYSTEM
OD245450/2025-2026:LEDDisplay-Supply,installation,testingandcommissioningof43inchfullHDLEDdisplayforvideowallarrangementfor24x7Setupincludingnecessaryconnection,HDMIcable,ratingtrayetc.asrequiredforcompleteinstallationwithallaccessoriesasrequiredanddirectedbyengineerin charge.
OD245449/2025-2026:Supply,installation,testingandcommissioningofClientMonitoringSystemwithIntelI7letestgenerationprocessrororabove,16GBramandSufficientTBHDDaspercalcultionwithsoftwarefor CCTV integration
itemH26
itemH26Code1
EXTRA LOW VOLTAGE SYSTEM-PUBLIC ADDRESSING SYSTEM(PAS)
OD245401/2025-2026:Speakers-CeilingMountedSpeaker-Supply,fixing,testingandcommissioningofceilingmountMetalGrilleSpeakerswithinbuiltlinematchingtransformerwithpower6Wwithallaccessoriesrequiredforcomplete instllation as required.
OD245403/2025-2026:Amplifiers 7.00 AllinoneAmplifier-Supply,Installation,Testing&Commissioningof2zoneamplifier180Wforconnectingtheabovespeakerswithnecessaryjacksandcableforconnectionsandinterconnectionwith all accessories required for instllation as required.- Built in FM with preset memories- 4 microphone input- USB/ SD Card support with MP3 Support- 180 W- Remote Control for Music source
OD245402/2025-2026:Cables & Conduits SpeakerCable-Supplyinganddrawingof2Core,TwinTwisted,ATCtinnedcopper,overallsheathed,ArmouredSpeakercable,16AWGforspeakersthroughsurface/Traywithallacessoriesasrequiredforcompleteinstallationandasinstructedbyengineerincharge/consultantandmaking good all damages made for installation.
EXTRA LOW VOLTAGE SYSTEM-STRUCTURED CABLING COMPONENTS
OD245358/2025-2026:Outlets, Cables & Patch Panels - Copper InformationOutletRJ45forData-Supply,fixing,fluketestingandcommissioningofCAT6InformationOutlets(Keystone)withShutteredFaceplate,Single port, white, jack, suitable PVC/GIModularBoxetc.includingnecessaryconnectionswithallaccessoriesrequiredforcompleteinstallation as directed by the Engineer in charge.
OD245359/2025-2026:InformationOutletRJ45forWi-Fi/CCTV-Supply,fixing,fluketestingandcommissioningofCAT6InformationOutlets(Keystone)withShutteredFaceplate,Singleport,white,jack,suitablePVC/GIModularBoxetc.includingnecessaryconnectionswithallaccessoriesrequiredforcomplete installation as directed by the Engineer in charge.
OD245368/2025-2026:InformationOutletRJ11-Supply,fixing,testingandcommissioningofRJ11InformationOutlets(Keystone)withshutteredFaceplate,singleport,white,jack,suitablePVC/GIModularBoxetc.includingnecessaryconnectionswithallaccessoriesrequiredforcompleteinstallationasdirectedby the Engineer in charge.
OD245360/2025-2026:CeilingConnectorAssembly-Supply,fixing,testingandcommissioningofreusableceilingconnectorassemblyforconnectingCAT5e/6/6Adirectlytothewirelessaccesspointsalongwithpigtailincludingnecessaryconnectionswithallaccessoriesrequiredforcompleteinstallationas directed by the Engineer in charge.
OD245380/2025-2026:CAT6Cable-SupplyinganddrawingofCAT6U/UTP23AWGLSZHAsperEIA/TIAStandards,surface/recessedmediumclassPVCconduitthroughwall/traywithallacessoriesasrequiredforcompleteinstallationandasinstructedbyengineerincharge/consultantandmakinggoodalldamages made for installation
OD245355/2025-2026:2PairCable-Supplyinganddrawingof2pairtelephonecableconsistsof0.5mmdiaFR,PVCCompoundannealedcopperconductor,unarmoredtelephonecableinsurface/recessedmediumclassFRSPVCconduitthroughwall/traywithallacessoriesasrequiredforcompleteinstallationandasinstructedbyengineerincharge/consultantandmakinggoodalldamagesmadeforinstallation.
OD245379/2025-2026:PairCable-Supplyingandlayingoffollowingmultipairarmouredtelephonecablethroughwall/traywithallacessoriesasrequiredforcompleteinstallationandasinstructedbyengineerincharge/consultant and making good all damages made for installation. 20 Pair Telephone Cable
OD245356/2025-2026:kroneBox-Supply,erection,testingandcommissioningoffollowingpairkronewithBoxincludingmountingframe,enclosureofISIgradewithlockablefrontcoverwithallaccessoriesrequiredforfor complete installation in wall as directed by the Engineer in charge. 20 Pair IDF Krone
OD245369/2025-2026:kroneBox-Supply,erection,testingandcommissioningoffollowingpairkronewithBoxincludingmountingframe,enclosureofISIgradewithlockablefrontcoverwithallaccessoriesrequiredforfor complete installation in wall as directed by the Engineer in charge.
OD245376/2025-2026:Patch Cord & Panels - CAT 6 PatchCable-Supply,Installation,Testing&CommissioningofCAT6PatchCordLSZHwithMouldedbootsOver-mouldedboo
tateachendprovidestrainreliefandmaintainsminimumbendradiusofthecable-2MeterwithTenderspecificationsandalltherequiredaccessoriestocomplete the system.
OD245373/2025-2026:PatchCable-Supply,Installation,Testing&CommissioningofCAT6PatchCordLSZHwithMouldedbootsOver-mouldedbootateachendprovidestrainreliefandmaintainsminimumbendradiusofthecable-1MeterwithTenderspecificationsandalltherequiredaccessoriestocomplete the system.
OD245364/2025-2026:PatchPanelforData-Supply,Installation,Testing&Commissioningof24PortfullyloadedPatchpanelCAT6(1Uwithrearwiremanager)45?silver-platedIDCs(insulation displacement connection)forsecure,reliablegas-tightconnectionswithTenderspecificationsandalltherequired accessories to complete the system.
OD245367/2025-2026:Cables & Patch Panels - Optical Fibre OFCCable-SupplyinganddrawingoffollowingArmouredMultimodeOpticalFibreCablethroughwallwithsufficientlamps/traywithallacessoriesasrequiredforcompleteinstallationandasinstructedbyengineerincharge/consultant and making good all damages made for installation. Armoured 6 Core Fibre Cable Multimode (MM) OM3/ OM4
OD245370/2025-2026:FibrePatchCable-Supply,Installation,Testing&commissioningofFibreopticPatchCordsLSZHMM(SCtoLCPC)-50/125-1MeterwithTenderspecificationsandalltherequiredaccessories to complete the system
OD245366/2025-2026:Supply,Installation,Testing&commissioningofFollowingPortLIU,19"rackmount,withadaptors,Swing-outsplicetrayin1USize.Shouldhavefrontaccessforeasysplice&patchmanagement.FullyloadedwithSCMMPigtails&adaptersforallthecourseswithTenderspecifications and all the required accessories to complete the system. 6 port Light Interface Unit
OD245377/2025-2026:Supply,Installation,Testing&commissioningofFollowingPortLIU,19"rackmount,withadaptors,Swing-outsplicetrayin1USize.Shouldhavefrontaccessforeasysplice&patchmanagement.FullyloadedwithSCMMPigtails&adaptersforallthecourseswithTenderspecifications and all the required accessories to complete the system.12 port Light Interface Unit
OD245365/2025-2026:Network Racks Supply,installation,testingandcommissioingoffollowingNetworkRackwithFrontglassdoor,RearPerforateddoorwithhandleLock&key.Front/Rearmountingangles,top,bottomopen,RAL9005/7035texturefinish,includingnecesaryexhaust/circulationfan,19"PowerSocketStrip with all accessories required for complete installation as directed by the engineer in charge. 9 U Network Rack
OD245378/2025-2026:SupplyandfixingofUnPerforatedCabletraywithcover/CeilingRacewayclosedwithsnapfitlid,suitablesupportsandbracketsandotheraccessoriesasrequiredconfirmingtoIEC-61537.TheTrayshallbegalvanizedforcorrosionprotectionconfirmingtoDINEN10346/ISO1461.TheCeiling Raceway shall be supplied with cover with the standard length of 3 Mtr.50 mm width x 60mm Height with Cover
OD245375/2025-2026:SupplyandfixingofUnPerforatedCabletraywithcover/CeilingRacewayclosedwithsnapfitlid,suitablesupportsandbracketsandotheraccessoriesasrequiredconfirmingtoIEC-61537.TheTrayshallbegalvanizedforcorrosionprotectionconfirmingtoDINEN10346/ISO1461.TheCeiling Raceway shall be supplied with cover with the standard length of 3 Mtr.100 mm width x 60mm Height with Cover
OD245371/2025-2026:Data Active: Switching Supply,Installation,Testing&CommissioningofFollowingPortLayer-2Non-PoESwitch10/100/1000Mbpswith2SFP+Slotsminimumloadedwith2X10GUplinkwithrackmountngbrackets with all accessories required for complete installation as per Tender specifications. 8 Port 10/100/1000 Mbps, layer 2, Non - POE, switch
OD245362/2025-2026:Supply,Installation,Testing&CommissioningofFollowingPortLayer-2Non-PoESwitch10/100/1000Mbpswith2SFP+Slotsminimumloadedwith2X10GUplinkwithrackmountngbrackets with all accessories required for complete installation as per Tender specifications.24 Port 10/100/1000 Mbps, layer 2, Non - POE, switch
OD245361/2025-2026:Supply,Installation,Testing&CommissioningofFollowingPortLayer-2PoESwitch10/100/1000Mbpswith2SFP+Slotsminimumloadedwith2X10GUplinkwithrackmountngbracketswithallaccessoriesrequiredforcompleteinstallationasperTenderspecifications.Theswitch should be capable to provide sufficient power budget to IP cameras as per the requirement. 8 Port 10/100/1000 Mbps, layer 2, POE, switch
OD245372/2025-2026:Supply,Installation,Testing&CommissioningofFollowingPortLayer-2PoESwitch10/100/1000Mbpswith2SFP+Slotsminimumloadedwith2X10GUplinkwithrackmountngbracketswithallaccessoriesrequiredforcompleteinstallationasperTenderspecifications.Theswitch should be capable to provide suffient power budget to IP cameras as per the requirement.24 Port 10/100/1000 Mbps, layer 2, POE, switch
itemH30Code18
OD245374/2025-2026:Supply,Installation,TestingandinstallationoffollowingportLayer3ManageableCoreswitchfullyloadedwith10GFP+Modelsfordownlink,includingrackmountingbrackets,inputconnectorshallbeasperIEC-320-C14withallaccessoriesrequiredforcompleteinstallationpopulatedwithminimum 2 X 10G SFP+ module for uplink as required as directed by the engineer in charge. 12 port Layer 3 Fibre switch
OD245354/2025-2026:Wireless Supply,Installation,Testing&CommissioningoffollowingIndoorTypeCeiling/WallMountofWi-FiAccessPointwithTenderSpecificationsallthenecessarylicensesandaccessoriestocomplete the system Wi-Fi Access Point, Type 1
itemH29
OD245457/2025-2026:Telephone PBX & Softwupply,Installation,Testing&CommissioningofPBXSystemwith40Analogextensionsexpandableupto50withallaccessoriesrequiredforcompleteinstallationaspertheTenderSpecifications.
OD245456/2025-2026:SurgeProtectionDeviceForPBX:Supply,Installation,TestingandcommissioningofSPDwithenclosure,thesurgeprotectiondeviceshallbesuitabletoprotecttelephonelinesdesignedtowithstandbothlightningcurrentandswitchingsurges.Technology:GDtube,NominalVoltage:180V,PulsedCurrent(10/350μs)Iimp:1KA,NominalDischargeCurrent(8/20μs)/phaseIn:5KA,Maximum discharge current: 10 KA,Voltage Protection Level(sym)<700V, Response time<1n sec
itemH30
itemH30Code17
OD245473/2025-2026:TVs/ Displays 50 Inch Display/ TV with wall mount and all the accessories.
OD245475/2025-2026:Projectors & Screens 3400ANSILumensWXGAShortthrowProjectorwithHDMI,VGAandRS232controlwithstandardlens
OD245474/2025-2026:Cables & Accessories 15 Meter HDMI Cable with 4K Support
Heating Ventilation & Air-Conditioning (HVAC) System-SPLIT AC UNITS
OD245389/2025-2026:Supply,installation,testing,andcommissioningoffollowingair-cooledINVERTERsplit-typeairc
itemH30Code16
itemH30Code15
OD245391/2025-2026:Supply, installation, testing, and commissioning of following air-cooled split-type air conditioners, with the specified minimum capacities. Each unit shall includearotary/scrollcompressor,air-cooledcondenser,GSScasing,filters,coolingcoils,canvasconnection,VCD,andfanmotors,asperthedrawings.Thesystemshallalsoincludecontrolwiring,refrigerantcontrols,andnecessaryaccessories.Theairconditionersshallbeequippedwithamicroprocessor-basedcontrolsystemwithindicationlampsforsystemoperationandathermostatintheIDUtoadjusttemperatureasrequired.RefrigerantshallbeR410AorR32,ensuringcompliancewithenvironmentalstandards.Thepriceshallincludeallduties,pre-filters,andGIpowder/epoxycoatedframeworksforoutdoorunits.Thescopealsocoversmakinggoodofanycivilworksasrequired.Allunitsshallbefactory-assembled,wired, piped, and tested before delivery to ensure quality and performance. 6 TR CEILING SUSPENDED DUCTABLE SPLIT UNIT
itemH30Code14
Heating Ventilation & Air-Conditioning (HVAC) System-DOUBLE SKIN AIR-HANDLING UNITS WITH DX COILS, VFD & PLUG FANS
itemH32
OD245411/2025-2026:Thesupply,Freight,Loading,unloadingoffollowingDoubleSkinAirHandlingUnitswithPowdercoatedInnerandouter0.6mm120GSMGSSsheet,40mmthickPUFinsulationof40kgdensitysandwichpanelswithpreplasticisedfinish,extrudedaluminumframework,ThermalbreakswithFansection,coilsection,filtersection,insulatedSSdrainpan,withplugfans,backwardcurvedDIDWblower,highefficiencyIE3ratedTEFCmotor,VFDdriven,IntertwinedCoolingcoilcoppertubesize1/2inch,aluminumfinsmin.450fins/mtr,10mmthicksyntheticmediafilterwithframe.90%efficiencydownto10micron,inspectionlampswithlimitswitch,VibrationIsolators,InletandOutletvolumecontroldampers,firedampersatoutletwithmicroswitchandwiringtoshutdowntheAHU,DoublecanvasconnectionsoffireretardantqualityforconnectingAHU'stoducting/plenum.Therequiredsandwichpanels,Motorassembly,Motorbase,CoolingCoilandDriers,Valvesinbothsides,VFDautomanuelcontrolpanelswithbypassfullyautomaticstarterpanelforcontrollingtheunitsetc.,AHUKit,commissioningfiltersetsandallotherstandardaccessoriesrequiredforcompleteinstallationasrequired.Lockableon/offpushbuttonincludingnecessarycontrolconnectionstobeprovidednearAHU.AllAHU’swillbegivenonlyonepowerinputcable. Any looping should be done by OEM in case of multiple motors in one AHU. 11.0 TR, 4400 CFM, 6 Row Double skin ceiling suspended AHU with DX coil, Mixing Box, VFD Drive Plug Fans
Heating Ventilation & Air-Conditioning (HVAC) System-CONDENSING UNIT (OUTDOOR UNIT) FOR AHU
itemH33
OD245381/2025-2026:Supply,Installation,testing&commissioningofAir-cooledcondensingunitcompletewithscroll/rotarycompressorconsistingofmicroprocessorbasedcontrol panel, sufficient refrigerant R410A / R32, vibration isolator etc. Condensing unit of minimum 11.0 TR capacity
itemH34
Heating Ventilation & Air-Conditioning (HVAC) System-REFRIGERANT PIPING
OD245419/2025-2026:ElectricalPowerCabling:Supply,layingandterminationofelectricalpowercablingofsuitablesizeandrunsincludingearthwithFRLSPVCinsulatedcopper conductor single core cable in PVC flexible conduit of suitable size from isolator to outdoor / indoor units outdoor units.
OD245421/2025-2026:DrainWaterPiping:Supply,installation,testingandcommissioningofcondensatedrainofuPVCpipingofadequatesizeasperBIS4985withnecessaryclamps,supports,hangersandfittingsuchasbend,tees,reducersetc.dulyinsulatedwith9mmthickclosedcellnitrilerubberasperthedrawingandtechnical specification
OD245417/2025-2026:Supply,installation,testingandcommissioningoffollowingWiredhandsetforIDU'swithallaccessoriesrequiredincludingwiringfromunittoremotelocation
itemH30Code12
Heating Ventilation & Air-Conditioning (HVAC) System-DUCT WORK
itemH30Code13
itemH35
OD245324/2025-2026:AcousticInsulation:Supplyandfixingof10mmthickClass1opencellnitrilerubberinsulationwithin-builtlifetimeantimicrobialprotectionofsupplyair duct upto three meter from the mouth of indoor unit. Insulation density shall be 140 - 180 Kg/m3. Material shall be EPA approved
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Tendernotice_1.pdf
PDF • 0.06 MB
CorrigendumTender.pdf
Other Document • 5.24 MB
StructuraldwgofKottarakkara.pdf
Additional Documents • 4.66 MB
MEP_Drawings.pdf
Additional Documents • 20.09 MB
PaymentDeclaration.pdf
Other Document • 0.24 MB
BOQ_1376944.xls
BOQ • 0.68 MB
RtenderSBDKottarakkara.pdf
Tender Documents • 1.37 MB
KOTTARAKKARA_MUNICIPALITY_ARCH_DRWNS.pdf
Additional Documents • 13.77 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .