Loading…
Loading…
Tender ID
Tender Value
₹45.1 L
EMD Value
₹90,220
Closing Date
26 Feb 2026, 4:00 pmClosed
Executive Engineer rnb division Awantipora
Executive Engineer rnb division Awantipora
Construction of Buildingless school at Middle School Herbagh Patalbagh........ (Sr. No. 1603)
2026_PWDJK_303649_2
Fresh-176/EEA/RNB of 2025-26/10144-54 Dated 17-02-2026
Open Tender
Civil Works
Percentage
90 days
PAMPORE
AS PER NIT
4 documents required · 4 mandatory
₹1,100
Executive Engineer rnb division Awantipora
₹90,220
17 Feb 2026
17 Feb 2026
27 Feb 2026
17 Feb 2026
26 Feb 2026
18 Feb 2026
Earth work in excavation by mechanical means (hydraulic excavator) in trenches for foundations, drains, pipes, cables etc. (not exceeding 1.5 m in width) and for shafts, wells, cesspits and the like not exceeding 10 sqm on plan, including dressing of sides and ramming of bottoms lift upto 1.5 m, including getting out excavated earth and disposal of surplus excavated earth as directed, within a lead of 50 metres: all kinds of soils
Providing & Laying of stone soling (dully hand packed) including watering dressing and ramming with all carriages loading un-loading and stacking etc complete
Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:4:8 coarse sand 40mm nominal size crushed stone agg.)
P/L in position specified grade of reinforced cement cencrete excld. The cost of centring, shuttering, finishing and reinforecement-All work upto plinth level. 1:1.5:3 graded stone agg. 20mm nominal size
Providing & laying in position cement concrete of specified grade excld. The cost of centring and shuttering all work upto plinth level(1:2:4 coarse sand 20mm nominal size crushed stone agg.)
Reinforced cement concrete work in beams, suspended floors, roofs having slope upto 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases upto five level including curing but excluding the cost of centring, shuttering, finishing and reinforcement with 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforced cement concrete work in walls (any thickness) including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts upto floor five level including curing but excluding cost of centering shuttering, finishing and reinforcement. 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size)
Reinforcement for RCC work incld straightning, cutting, bending, placing in position & binding all complete (TMT bars of grade Fe-500D or more.)
Brick work with common burnt clay (non-modular) bricks of class designation 7.5 in foundation and plinth including curing in Cement mortar 1:6 ( 1 cement : 6 coarse sand)
Extra for brick work with common burnt clay bricks/cement concrete bricks in superstructure above plinth level upto floor five level
Providing wood work in frames of doors, windows, clerestory windows & other frames, wrought framed & fixed in position KD wood of German Quality
Providing & fixing panelled or panelled & glazed shutters for doors & windows and clerestory windows including ISI marked black enamelled M.S Butt hingeswith necessary screws excluding panelling KD wood of German Quality 30mm thick
Providing and fixing 35 mm thick wire gauze shutters using galvanised M.S. wire gauze of average width for apertyre 1.4 mm in both direction with wire of dia. 0.63 mm for doors, windows and clerestory windows with hinges and necessary screws: KD wood of German Quality
Providing and fixing panelling or panelling and glazing in panelled or panelled or glazed shutters for doors, windows and clerestory windows (Area of opening for panel inserts excluding portion inside grooves or rebates to be measured) panelling for panelled or panelled and glazed shutters KD Wood German Quality 25mm to 40mm thick.
Providing & fixing 3.5 mm Thick Glass panes i/c necessary beading and nails complete as directed. By EIC
12mm Cement Plaster of mix 1:6(1 cement:6 coarse sand)
6 mm cement plaster to ceiling of mix 1:3(1 cement: 3 fine sand)
Providing and applying white cement based putty of specified thickness, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. 2 mm thick
Distempring with 1st quality acrylic washable distemper (ready made) of approvedd manufacture & of required shade/ colour compleate as per manufacture's specifications Two or more coats on New Work
Wall Painting with acrylic emulsion paint of approved brand and manufacture to give an even shade. Two or more coats on new work
Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade, one or more coats on new work.including applying of priming coat: with ready mixed pink or grey primer of approved brand and manufature on wood work (hard and soft wood).
Providing & fixing of 40x5mm flat iron hold fast 40cm long including fixing to frameswith 10mm dia bolts nuts & wooden plugs and embedding in cement concrete block 30x10x5cm 1:3:6mix (1cement:3coarse sand:6 graded st agg)20mm nominal size.
Filling available excavated earth (excl. rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20 cm in depth, consolidating each deposited layer by ramming and watering, lead upto 50 m and lift upto 1.5 m.
Cement concrete flooring 1:2:4 (1cement: 2 coarse sand: 4 graded stone aggregate) finished with a floating coat of neat cement including cement slurry and curing complete, but excluding the cost of nosing of steps etc. complete. 50 mm thick with 20mm nominal size stone aggregate.
Providing and fixing strips in joints of terrazzo/ cement concrete floors. Glass strips (4 mm thick)
Centring and shuttering incld. Strutting, proping etc & removal of form work for Founadtions, footings, bases of columns for mass concrete.
Centring and shuttering incld. Strutting, proping etc & removal of form work for suspended floors, roofs, landings, balconies & access plateform
Centring and shuttering incld. Strutting, proping etc & removal of form work for Lintel, Beams etc
Centring and shuttering incld. Strutting, proping etc & removal of form work for colums, pillars, piers, abts, posts and strats
Structural steel work in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. i/c soffits / eaves board Welded
Providing corrugated G. S. sheet roofing including vertical/curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (upto any pitch in horizontal/vertical or curved surface)excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.0.50 mm thick with zinc coating not less than 275 gram/m2
Providing ridges of hips of width 60cm overall width plain GS sheets fixed with polymer coated J or L hooks bolts & nuts 8mm dia GI limpet & bitumen washers complete 0.50mm thick with zinc coating not less than 275g/sqm
Providing and fixing aluminum tower bolts ISI marked anodized (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade with necessary screws etc. complete : 100x10 mm
Providing and fixing aluminum handles ISI marked anodized (anodic coating not less than grade AC 10 as per IS: 1868) transparent or dyed to required colour and shade with necessary screws etc. complete. 125 mm
Providing and Fixing of L Drop of Standard make i/c Locking system complete
Making plinth protection 50mm thick of cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 20 mm nominal size) over 75mm bed of dry brick ballast 40mm nominal size well rammed and consolidated and grouted with fine sand including finishing the top smooth and curing complete
Provding & fixing 04 layer 18 gauge (304)plain stainless steel railing of approved make Like Jindal i/c master pillar and boster on alternate steps or equlant i/c welding, polishing as per directions of engineer incharge complete
Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge. Polished Granite stone slab jet Black, Cherry Red, Elite Brown, Cat Eye or equivalent.
Carriage of materails By Mech.Transport, from source to site of work
Stone agg. for an avg lead of 10 km
Sand from for an avg lead of 5 km
Bricks from for an avg lead of 15 km
Electrification.
Wiring for light point/ fan point/ exhaust fan point/ call bell point with 2x1.5 sq.mm FRLS PVC insulated copper conductor Havell/Polycab/Anchor/eq,standard make as desired by engineer incharge ) single core cable in surface/recessed medium class PVC conduit, with modular switch (Anchor ramn plus/ Legand Mylinc /SSK NV/Schnelder/ABB Tvisho make) moduar plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.as approved by EIC.
Wiring for Light /Power Plug with 2 x 4 sq.mm+1x4 sqmm Earth wire,FRLS PVC Insulated Copper Conductor (Havell/Polycab/finolex/Anchor/equivalent as directed by Engineer-incharge) single core cable in surface/Recessed medium class PVC Conduit
Supplying and fixing suitable size GI Box with modular plate and cover infront on surface or in recess, including providing and fixing 6 pin 5/6 & 15/16 A Modular socket outlet and 15/16 A modular switch, modular plate suitable GI Box connections etc, as required. Modular Switch & socket (Anchor roma plus/Legrand Myllnc/SSK NV/Schneider Lelya/ABB Tvisha make) same to be approvedby Engineer incharge.
Wiring for lighting Circuits/ inverter circuits/ 6-10 amp power plug with 2x2.5 sq.mm FRLS PVC insulated copper conductor (Havell/polycab/ Fenolex/Anchor/Equivalent as direted by Engineer incharge) single core Cable in surface/Recessed medium class PVC conduit along with 1 No 2.5 sq mm FRLS PVC insulated copper conductor single core cable for loop earthing as required.
Supplying and fixing suitable size GI Box with modular plate and cover infront on surface or in recess, including providing and fixing 2 nos 3 pin 5/6 A Modular socket outlet and 2 nos 5/6 A modular switch, connections etc as required (for light plugs to be used in non residential buildings). Modular switch and socket (Anchor roma plus/Legrand Myllnc/SSK NV/Schneider Lelya/ABB Tvisha make) same to be approvedby Engineer incharge.
Supplying and fixing suitable size GI Box with modular plate and cover infront on surface or in recess, including providing and fixing 3 pin 5/6 A Modular socket outlet and 5/6 A modular switch, connections etc as required.
supplying installation testing and commissioning of indicator of Anchor roma plus/Legrand Mylinc/SSK NV Schnelder Livla/Crabtree athena make.)
Sub Head -2 Fixtures and fittings
Supply fixing testing and commissioning of backlite holder /batten holder/angle holder /ceilling rose SSK/Anchor make incl. PVC Block and 15 watt LED Lamp, Phillips/Trulux /Wipro make / sample to approved before installation.
Supply, Installation, Testing and Commissioning of 1200 mm sweep, ceiling fan with 3 No. Aluminium blades, 30 cm long down rod, 2nos, canopies, shackle kit, Power Factor not less than 0.9, Service Value Including safety pin, nut bolts, washers, temperature rise-75 degree C (max.), Insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hx, and including iron hook complete. USHA/Havells/Crompton make ( sample to be approved before installation)
Supply and fixing of 6 amp/250 V AC fan dimmer step type 2 module with cover plate Anchor roma plus/Legrand Mylinc /ABB Thysha/schneider Livia/Havell Coral make.
S/F testing and comm. Of MCB's 10 K of the below mentioned capacities in sub main controls legrand C curve/ Schinidor/ABD /equivalent make as directed by engineer Incharge
6-32 Amp SP MCB
40-63 amp DP MCB
Supplying and fixing following way. single pole and neutral, sheet steel, MCB distribution board, legrand/Shtaider/lager mako) 240 V, on surface/ recess,complete with tinned copper trus bar, neutral bus bar, earth bar,din bar, interconnections, powder jpainted including earthing etc.as required. (But without MCB/RCCD/Isolator)
24 way, Double door
Supply fixing testing and commissioning of backlite holder /batten holder/angle holder /ceilling rose SSK/Anchor make incl. PVC Block and 15 watt LED Lamp, Phillips/Trulux /Wipro make / sample to approved before installation.
S/L, testing and commissioning of PVC XLPE Insulated PVC (unarmoured) cable 650 V/1100 V Grade as per IS: (Part 1) 1988 with upto Date Amendments.Havell/Eq. standard make as directed by engineer Incharge and making end termination withs brass compression gland and aluminium lugs of required size.
25 sq.mm 2 core
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.77 MB
BOQ_986110.xls
BOQ • 0.39 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .