| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹75.2 LAccepted-AOC | L1 | Accepted-AOC LOWEST REASONABLE BID | |
| 2 | L2₹82.3 L+₹6.6 L (8.77%)Rejected-Finance 77 KAILASH PURI BIKANER RAJASTHAN PIN 334001 | BIKANER | RAJASTHAN | 334001 | L2 | Rejected-Finance NOT LOWEST | |
| 3 | L3₹86.6 L+₹10.9 L (14.4%)Rejected-Finance | L3 | Rejected-Finance NOT LOWEST | |
| 4 | L4₹98.4 L+₹22.7 L (30.0%)Rejected-Finance 33 MAHAVEER NAGAR NANDRI ROAD PO SARAN NAGAR JODHPUR 342015 | JODHPUR | JODHPUR | RAJASTHAN | 342015 | L4 | Rejected-Finance NOT LOWEST | |
| 5 | L5₹1.1 Cr+₹33.1 L (43.7%)Rejected-Finance | L5 | Rejected-Finance NOT LOWEST |
Tender Value
₹99 L
EMD Value
₹1.7 L
Closing Date
1 Mar 2022, 6:00 pmClosed
Eligibility, documents, scope and key termsEligibility, required documents, scope of work and key terms of this tender, in one click.
CWE ARMY JODHPUR
CWE ARMY MULTAN LINE ARMY AREA JODHPUR
REPAIR TO RCC WALLS COLUMNS BEAM ROOF PROJECTIONS AND REPAIR TO ROLLING SHUTTER ETC. AT ARMY AREA UNDER GE BANAR JODHPUR
2022_MES_502751_1
82122/52/E8
Open Tender
Civil Works
Item Rate
365 days
GE BANAR
Please refer Tender documents.
8 documents required · 8 mandatory
₹1,000
Yes
GE BANAR
₹1.7 L
Yes
16 Mar 2022
20 Jan 2022
7 Mar 2022
20 Jan 2022
1 Mar 2022
15 Feb 2022
60 days
Amount
Razing off/ taking down old existing unserviceable cement plaster, loose / unsound weaken cement concrete of any description and in any position from existing external / internal surfaces of RCC roof / Slab / Beams / Columns / RCC facias, or any surface average depth 5-25mm (Approx height up to 7.5 m from natural ground level) with power driven of pneumatic chisel and removal of demolished material outside MOD land including cutting of all edges, making square shoulders of the cavities, roughening the smooth surfaces, scrapping out / removing corrosion all loose / scale / rust etc from the visible unplastered surface and applying one coat of styrene butadiene polymerized cement mortar modifier or AR. Chemicals for B/P the surface before application of rheoplastic cementious based repair must conform to BS 6319. Ensure no porosity in surface complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M & L for applying technoseal V1 or technically Techno-commercial equivalent of other makes as per appendix "D", on the floors of RCC roofs of shed @ 3.5 kg/sqm for two coat, a cement based powder modified with special additives and ready to use, mixed with water,it cures forming a coating, with limited thickness which resists the penetration of water to achieve the compressive thickness of 36N/mm2 in 3 days adhesive bond strength of 8.2 N/mm2 coating to be applied after proper surface penetration to remove dust, dirt etc. cleaning, mixing using slow speed drill and application of two coats in 3 days complete as specified and directed by Engr-in-charge. Note—(i)This item work shall be executed by the authorized applicator of manufacturer. (ii) Min 24 hours gap duration between Ist & IInd coat.
Supply and injecting low viscous epoxy resin with hardner for injection grouting having specific gravity 1.1-1.2 gms/cc in combination with expanding powered or dual shrinkage compensating non shrink free flow plasticized grouts .Dose 80gm/hole or complete all as specified and directed by Engr-in-Charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M&L for drilling hole in RCC structures for pressure grouting using drilling machine up to a depth of 100 mm and 14 mm dia, with the gap of 600mm C/C removing dust, etc by vacuum cleaner and blowers, providing and fixing of PVC perforated nozzles 12 mm dia, 100 mm long in both direction and fixing with using Polyster Resin based Anchoring material in concrete complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M & L for providing and applying passivating protective matrix conforming to EN 1504-7-2006 on corroded visible steel surface and old RCC surface forming a continuous film not less than 1 mm of single component and preparing the surface to receive the epoxy grout mortar including and providing necessary proportions. Bracing and runners to relieve the members as required and as per design and pattern including preparing the surface to match with the existing surface complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M&L for providing and applying of alkaline based Anti oxidizing compound for steel structure conforming to ASTM D 1748-10(2015) after cleaning to loose scale or oxidized chips from bars having specific gravity 1.2 -1.22. The material to be applied to the rusted metal using brush, allow it to react for 16 to 24 hrs and afterwards wire brushing the surface and cleaned with dry cloth before application of protective coating etc complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M & L for providing 10 mm thick component chloride free thixotropic fibre reinforced polymer modified repair mortar 5F in the ceiling area of RCC compling with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 in cement mortar in the ratio 1:4 mixed with styrene butydiene polymerized cement mortar modifier or AR for bonding with cementious mortar specially adhering to BS 6319 having specific gravity of 1.025 to 1.04, ( minimum 43% solid contents) not less than 2% by weight of cement and as per manufacturer's instructions for external or internal surface of RCC /slab /beam /columns/facias/any brick or stone wall surface etc. Top surfaces of the plaster shall be finished even and smooth with using extra cement including taking down of old cement plaster and dispose of to a distance to 50 mtr. etc complete all as specified and as directed by Engr-in-charge. Note—This item shall be undertaken by the authorized rep of manufacturer.
M & L for drilling hole chemical anchoring of reinforcement on existing columns/chajj/beams with Hiti HIT-HY 70 in, minimum hole depth 100mm, steel bar 12 mm dia and drill bit dia 14 mm, fixing with shear connectors complete all as specified and directed by Engineer-in-charge. Polyster Resin based Anchoring material for Horizontal or vertical applications complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M & L for providing and applying Rheoplastic non shrink, corrosion resistant, High strength compound on external or internal surface of RCC roof/floors/ceilings/chajjas /slab/balconies /beam /columns/facias/wall surface etc, BS 66 having compressive strength as Bs 4551-80 thickness of 40- 50mm with 1:4 cement mortar and strength (ASTM C 109)-80 Mpa @ 28 days, Tensile strength 2.0N/mm2 @ 28 days (ASTM C 348)- 4 Mpa @ 28 days, Flextural strength 10N/mm2 (ASTM C 348)-11 Mpa @ 28 days, Young's modulus -27 KN/sqmm (ASTM D469), Expansion charactristics (ASTM C 827-1987) Unrestrained expansion upto 4% pressure to restrain plastic Expansion approx. 0.004 N/sqmm. Before pouring micro concrete it is recommended to apply granolithic E-Resin based solvent free concrete bonding agent/EP in accurate proportion with complete homogenesity having mix density of 1.45 to 1.5 kg/litre, Compressive strength (BS 6319 pt.2)-40 Mpa at 7 days, Flextural strength (BS 6319 pt.3)- 25 Mpa at 7 days, Tensile strength (BS 6319 pt.7)- 15 Mpa at 7 days, Bond strength (ASTM C 881)- 11 N/sqmm at 7 days, having an over lay time of 03 hrs at 30 C. Pouring of micro concrete into the formwork must be done using suitable arrangement or pumping device for uniform flow of micro concrete. The side shuttering can be removed after 3 days and the bottom shuttering after 7 days, ensuring proper bond between the micro concrete and existing concrete substrate etc complete including all tools and tackles as directed by Engr-in-Charge. Note: - Rate quoted shall include for necessary formwork required in the item complete all as specified and as directed by Engr-in-charge. Note—This item shall be undertaken by the authorized rep of manufacturer.
M&L for providing and fixing external surface of RCC/roof/slab surface etc welded MS meshscreen to be fitted mechanically with screw weighing not less than 1 kg/sqmt and applying of alkaline based Anti oxidizing compound for steel structure conforming to ASTM D 1748-10(2015) Having specific gravity 1.2 -1.22.on wire mesh having Mixed density of 2.01.2.05, Adhesive bond strength - 1 N/mm, touch drying time of 10-15 minutes and applying 50 mm thick one component chloride free thixotropic fibre reinforced polymer modified repair material maxtreat PATCH UP in combination with cement mortar in the ratio of 1:4 mixed with liquid integral waterproofing additive/1000L for concrete conforming to EN 934-2 T9 confirming to IS 2645-2003, having specific gravity 1.1-1.2 gm/cc, & styrene butadiene polymerized cement mortar modifier or AR.. a rheoplastic cementious based repair compound conforming to BS 6319. Ensure no porosity in new surface, having specific gravity of 1.02 in ratio as per recommendation of manufacture compling with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 at the outer or inner Brick or RCC walls to achieve compressive strength of 15 N/mm in 1 Day, 25 N/mm in 3 days adhesion bond strength of > 2 N/mm providing and mixed with styrene butadiene polymerized cement mortar modifier or AR complete all as specified and as directed by Engr-in-charg. Note—This item work shall be executed by the authorized applicator of manufacturer.
M&L providing and filling three components compound (A) graded filler (B) E-Resins (C) thixotropic agents with adjustable consistency by varying the filler component having the density of 1.64 -1.68gm/cc for RCC/brick walls/floor/ columns/ beams cracks after opening up in “V” groove manner covering the area of 300mm from central line of crack with the depth of 10 mm complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M & L for curing of the surface using wax based concrete curing compound CC 75 curing efficiency compling with the internationally recognized ASTM C309-90 standards incuding all tools and tackles complete all as specified and directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M&L for providing 50 mm thick component chloride free thixotropic fibre reinforced polymer modified repair mortar BS5F compling with ASTM C 109 with flexural strength ASTM C 348 @ 7 days meeting 7N/mm2 and tensile strength @ 7 days (ASTM C 307) >3 N/mm2 at the RCC surface mixed with 30 kg cement mortar in the ratio 1:1(BS5F 30kg mix with 30 kg cement mortar of ratio 1:4) and mixed with styrene butydiene polymerized cement mortar modifier or AR for bonding with cementious mortar specially adhering to BS 6319 having specific gravity of 1.025 to 1.04, minimum 43% solid contents @ 2% by weight of cement and as per manufacturer,s instructions.for external or internal surface of RCC /slab /beam /columns/facias/any surface etc. Top surfaces of the plaster shall be finished even and smooth with using extra cement complete all as specified and as directed by Engr-in-charge. Note—This item work shall be executed by the authorized applicator of manufacturer.
M&L dismantling Asbestos cement (corrugated, semicorrugated, etc.) sheets in roof coverings/door covering all as specified and directed by Engr-in-charge.
M&L for 6mm thick asbestos cement,corrugated or semi corrugated sheets in roof fixed with L or J type hook etc complete all as specified and directed by Engr-in-charge.
M&L for dismantling of 100mm dia cast iron pipes, jointed in cement mortar and taking out of trenches, if required all as specified and directed by Engr-in-charge.
S&F for 110mm dia PVC(SWR) rain water pipes single socketed ,in any length with rubber ring joints fixed to wall all as specified and directed by Engr-in-Charge.
S&F 110mm dia PVC(SWR) bends/shoe any radius with access door complete all as directed by Engr-in-Charge.
M&L for taking down chowkats or frames with shutters (W/o taking off shutters from the frames) n exc 1.5 sqm each all as specified and directed by Engr-in-charge.
M&L for taking down chowkats or frames with shutters (W/o taking off shutters from the frames) exc 1.5 sqm but n exc 4sqm each all as specified and directed by Engr-in-charge.
M&L for 2nd Class hard wood as in plain,solid,straight chowkhats and frames,wrought,framed rebated on the solid,rounded or chamfered,put together with glue pinned at joints complete all as specified and directed by Engr-in-charge.
M&L for 2nd Class hard wood Plain fillets, square, rectangular or traingular in section (of sectional area not exc 3 sq. cm), clean sawn, secured with nails or brads all as specified and directed by Engr-in-charge
S & F for Expanded metal (weight not less than 4 Kg per Sqm),cut to length,bet to shape required and tying with and including annealed mild steel wire not less than 0.9 mm dia staples supplied and fixed complete to wood or staples all as specified and directed by Engr in Charge.
Material and labour for preparation of old ceiling surface including pillars etc (plastered or unplastered) by scrapping down smoke spot moulds, moss and efflorescenet salt and treating oil and greasy spots and applying two coat of white wash with moonj brush only complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of newly plastered or unplastered surfaces of ceilings and applying three coats of white wash complete all as specified and directed by Engineer-in-charge.
Material and labour for preparation of old wall surface including pillars etc (plastered or unplastered) by scrapping down smoke spot moulds, moss and efflorescenet salt and treatin oil and greasy spots and applying two coat of white wash with moonj brush only complete all as specified and directed by Engineer-in-charge.
M&L for two coats of cement base paint on newly plastered or untreated surfaces of walls including necessary preparation of surfaces all as specified and directed by Engr-in-charge.
M&L for two coats of cement base paint on old surfaces of stone masonry walls including necessary preparation of surfaces all as specified and directed by Engr-in-charge.
M&L for complete removal of existing treatment on walls and applying two coats of oil emulsion distemper including preparation of surfaces complete all as specified and directed by Engr-in-charge.
M&L for two coats of oil emulsion distemper on newly plastered/untreated surface of walls over a coat alkali resistant priming paint including preparation of surfaces all as specified and directed by Engr-in-charge.
M&L for raking out joints/pointing to squared rubble masonry, coursed or uncoursed built in cement mortar complete all as specified and directed by Engineer-in-charge.
Material and labour for keyed pointing to stone masonary surface in CM 1:4 complete all as specified and directed by Engineer-in-charge.
Material and labour for two coats of synthetic enamel paint over a coat of pink primer including preparation of newly wooden surfaces of girth exc 10cm complete all as specified and directed by Engineer-in-charge.
Material and labour for one coat of synthetic enamel paint including preparation of old painted wooden surfaces of girth exc 10cm complete all as specified and directed by Engineer-in-charge.
Material and labour for one coat of synthetic enamel paint including preparation of old treated steel surfaces of girth exc 10cm complete all as specified and directed by Engineer-in-charge.
M&L for repair to sliding door of size n exc 10 sqm made of MS Plate manual/gear operative type, denting of various parts, cleaning of guide rails, laths by kerosene and proper greasing , oiling to make the system smooth/easy functional , including supply and fix new nuts & bolts of existing size by removing old/rusted nuts and bolts , necessary welding wherever required, all as specified and directed by Engineer-in-charge
All as per Srl item No 36 above but area exc 10 Sqm but n exc 20 Sqm
All as per Srl item No 36 above but area exc 20 Sqm but n exc 25 Sqm
All as per Srl item No 36 above but area exc 25 Sqm but n exc 30 Sqm
M&L for removing and refixing of wheels 200mm size with ball bearing fixed at bottom of sliding doors to move/slide on rails after oiling, greasing and cleaning the bearing and fixed in correct position by making in alignment complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair wheel of sliding door as fixed in existing sliding door of any dia & specification, of ISI marked complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of sliding doors of 90/100mm size and description complete all as specified and directed by Engineer-in-charge.
M&L for repair to rolling shutters of size n. exc 5 Sqm each, manual/gear operative type , denting of various parts, cleaning of guide rails, laths, top cover by kerosene and proper greasing , oiling to make the system smooth/easy functional , including new nuts & bolts and greasing of gear box if required of existing size by removing old/rusted nuts and bolts , necessary welding & taking down wherever required, as directed, giving proper tension to the spring all as specified and directed by Engineer-in-charge.
All as per Srl item No 43 above but area exc 05 Sqm but n exc 10 Sqm
All as per Srl item No 43 above but area exc 10 Sqm but n exc 20 Sqm
All as per Srl item No 43 above but area exc 20 Sqm but n exc 30 Sqm
All as per Srl item No 43 above but area exc 30 Sqm but n exc 40 Sqm
M&L for Repair to MS door of size n exc 10 sqm making necessary repair or necessary welding, drilling wherever required with new or old hinges if required, hold fasts,pivot, making the surface good all as specified and directed by Engineer-in-charge.
All as per Srl item No 48 above but area exc 10 Sqm but n exc 15 Sqm
All as per Srl item No 48 above but area exc 15 Sqm but n exc 25 Sqm
All as per Srl item No 48 above but area exc 25 Sqm but n exc 30 Sqm
Supply and fixing in repair gear box of standard size for rolling shutter with complete fitting/various parts of gear box, spring etc including painting all as specified and directed by Engineer-in-charge.
Supply and fixing in repair ball bearing of rolling of 90/100mm size and description complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair spring hinge of rolling shutter of Gde-0 600mm long all as specified and directed by Engineer-in-charge.
Supply and fixing in repair spring hinge of rolling shutter of Gde-0 450mm long all as specified and directed by Engineer-in-charge.
Supply and fixing in repair 600mm Mild steel sliding door bolts made of 16mm dia round bar with MS hasp & staple complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair Safety lever locks of mild steel with 4 leavers for rolling shutters all as specified and directed by Engineer-in-charge.
Supply and fixing in repair of MS pipe of existing dia (50/40 mm) to operate gear box complete including new hold fasts/ brackets for fixing in shaft all as specified and directed by Engineer-in-charge.
Supply and fixing in repair cover hood of 1mm thick MS sheet including 02 coat of synthetic enamel paint over a coat of Red oxide primer matching to existing finish all as specified and directed by Engineer-in-charge.
Supply and fixing in repair MS bracket plate to the side of cover hood made of 6mm to 8mm dia MS plate all as specified and directed by Engineer-in-charge.
Material and labour for two coats of synthetic enamel paint over a red oxide primer including preparation of newly replaced steel surfaces of girth over 10cm matching to the existing finish complete all as specified and directed by Engineer-in-charge.
S & F in repair framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks,locking arrangement for doors and similar work conforming to Fe 410-0 or Fe 310-0 complete all as specified and directed by Engineer-in-charge.
Supply and fixing in repair collapsible steel gates, top hung, consisting for channel pickets, pivoted flat bars, top and bottom runners, brass handles etc., as specified, erected in position and securing runners with holdfasts and brackets complete all as specified and directed by Engineer-in-charge.
M&L for repair to Steel gate of size exc 5 sqm but area n exc 10 sqm making necessary repair or necessary welding, drilling wherever required with new or old hinges if required, hold fasts,pivot, making the surface good including one coat synthetic enamel paint on all surface complete all as specified and directed by Engineer-in-charge.
All as per Srl item No 64 above but area exc 10 Sqm but n exc 15 Sqm
All as per Srl item No 64 above but area exc 15 Sqm but n exc 25 Sqm
Hiring HYDRA to realgin & lift the heavy MS Door or sliding Door during repair work Note : (i) Time of HYDRA shall be commenced after reaching at site of work. (ii) HYDRA shall be deployed only for heavy MS Door/Sliding Door as directed by Eng-in-charged.
S&F in repair rolling shutter side motor (copper wiring) of single phase of power 370W,220 V,Frequency- 50Hz,Speed-4.8r/mi,lifting capacity of 600 Kg with remote of as per sample complete all as specified and directed by Engr in Charge.
S&F in repair garari of rolling shutter of suitable size as per ground requirement (height of rolling shutter up to 7.0 mtr) complete all as specified and directed by Engr in charge
S&F in repair curtains/Laths of 1mm thick of rolling shutter of suitable size as per ground requirement (height of rolling shutter up to 7.0 mtr) complete all as specified and directed by Engr in charge
Labour for taking out carefully existing aluminum/copper strip of any size including mounting porcelain/PVC insulators and air termination rods from roof/wall of height upto 10mtr and seperating the complete as a serviceable and unserviceable for reuse/taking store as credit schedule.
Labour for Re-fixing the aluminum strip retieved from Srl item No 71 in position with new insulators and proper layout on roof/wall of height upto 10mtr as directed by Engr-in-Charge at site.
S&F in replacement of GI strip of size 32 x6 mm incl saddles on wall 32mm and burried in ground depth not less than 60cm complete all as specified and directed.
S&F in replacement of aluminum strip of size 25x3.15mm incl saddles/supporting insulators to run over the roof complete all as specified and directeed.
S&F in replacement of copper strip of size 25x3.15mm incl saddles/supporting insulators to run over the roof complete all as specified and directeed.
Supply and fixing in replacement of gun metal test point terninal block of size 75 x 75 x 25 mm drilled and screwed inlcuding 3 Nos 8 mm dia 25 mm long hex head screw mounted on PVC Box of size 100x100x50mm fixed on wall complete all as specified and directed.
Supply and fixing in replacement of air termination aluminium rod 12mm dia 300mm long complete all as specified and directed.
Supply and fixing in replacement of air termination copper rod 12mm dia 300mm long complete all as specified and directed.
Supply and fixing in replacement of GI tubing 40mm dia medium grade in incl necessary fittings for lowering in borewell of depth upto 30 mtr and PCC work for grouting at roof top to mount the air termination rod complete all as specified and directed.(Note : PCC work for grouting on roof will be measured and paid seperately under relevent item of Schedule).
M&L for earthing in replacement/renewal of complete with galvanised steel earth plate electrode size 600x600x6.0mm thick buried directly in ground vertically in a pit of depth not less than 2.25 mtr below ground levels with top edge of the earth plate not less than 1.5 mtr below normal ground level surrounded from all sides by mixture of charcoal and common salt and electrode connected to and including galvanised strip as earth continuity conductor of size 25x4mm bracing with plate by means of bolts, nuts, check nuts and washers of galvanised steel and GI pipe light grade 20mm dia bore for watering funnel with wire mesh refilling with vegetable soil without bolders and stones, gravels and aggregate etc,and CI cover with frame, PCC chamber pit with PCC 1:3:6 type C-2 excavation and earth work all as shown in electrical plate No 3 connected to earthing test point all as specified or indicated including testing on completion. NOTES : The earth pit shall be refilled by boulders free vegetable soil.
M & L for bore well earthing with mechanical boring machine of 150 mm dia - 30 mtr depth including PVC pipe 150 mm dia heavy duty upto 6 mtr and including PCC form work around the casing pipe for grouting the casing pipe of size 50x50x40cm with 1:3:6 by using 20mm aggregate abd all as specified and directed.
M&L PCC (1:3:6) Type C1 using 20 mm graded stone aggregate for coping of GI pipe at roof top with form work in any situtaion as required and directed at site.
Note for all above items:- All items are for "Material and labour / Supply and fix" and to be executed in"Repairs" only incl taking down old materials unless otherwise specifically mentioned as "Supply only" or "fixing only" in BOQ. Contractors are requested to quote their rates accordingly.
ABHOG INFRASTRUCTURE PRIVATE LIMITED
AMIT RISHABH BUILDERS PVT LTD
DIWAKAR CONSTRUCTION CO.
M/S RAM SINGH AND COMPANY
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .