Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹5.2 LAccepted-AOC | L1 | Accepted-AOC L1 | |
| 2 | L2₹5.9 L+₹71,223 (13.7%)Rejected-AOC | L2 | Rejected-AOC L2 | |
| 3 | L3₹6.3 L+₹1.1 L (21.4%)Rejected-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L3 | Rejected-AOC L3 | |
| 4 | L4₹6.4 L+₹1.2 L (23.5%)Rejected-AOC KANCHANTULLI SOUTH BADHARGHAT AGARTALA WEST TRIPURA PIN 799014 | WEST TRIPURA | TRIPURA | 799014 | L4 | Rejected-AOC L4 | |
| 5 | L5₹7.2 L+₹2.0 L (39.4%)Rejected-AOC | L5 | Rejected-AOC L5 |
Tender Value
₹8.3 L
EMD Value
₹16,685
Closing Date
30 Nov 2022, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Annual Maintenance Contract for the AC systems installed at Old IGM Hospital Building, Agartala
2022_CEPWD_34255_1
87/EE/DNIeT/MECH.DIVN/AGT/2022
Open Tender
Electrical Works
Works
730 days
AGARTALA
Please refer Tender documents.
7 documents required · 7 mandatory
₹1,000
₹16,685
24 Jan 2023
21 Nov 2022
30 Nov 2022
21 Nov 2022
30 Nov 2022
21 Nov 2022
Amount
General servicing of 1.5/2.0 TR capacity AC machines (indoor & outdoor unit) half yearly as per direction of the Engineer-in-Charge.
General servicing of 1.5 TR window type AC machines half yearly as per direction of the Engineer-in-Charge.
Leak testing of Condensing & evaporator unit for performance and pressure testing etc for 1.5/2.0 TR capacities split type AC's and repair with brazing as per direction of the Engineer-in-Charge.
Leak testing of Condensing & evaporator unit for performance and pressure testing etc for 1.5 TR capacities window type AC's and repair with brazing as per direction of the Engineer-in-Charge.
Charging fresh refrigerant gas for 1.5 TR/2.0 5TR Capacity split type Ac's as per direction of the 4Engineer-in-Charge.
Charging fresh refrigerant gas for 1.5 TR Capacity window type Ac's as per direction of the Engineer-in-Charge.
Providing, fitting & fixing of hermetically sealed reciprocating compressor for 1.5 TR capacity split type AC's replacing old one as per direction of the Engineer-in-Charge.
Providing, fitting & fixing of hermetically sealed reciprocating compressor for 2.0 TR capacity split type AC's replacing old one as per direction of the Engineer-in-Charge.
Providing fitting & fixing of hermetically sealed reciprocating compressor for 1.5 TR capacity window type Ac machines replacing old one as per direction of the Engineer-in-Charge.
Supply & installation of additional length of copper pipe of 5/8 " diameter and 1/4 " diameter for suction and liquid line with insulation and necessary wiring to connect the indoor and outdoor units as per direction of the Engineer-In-Charge.
Fitting, fixing of blower motor of Ac's after rewinding in/c necessary replacement of bush, shaft etc with complete varnishing as per direction of the Engineer-in-Charge.
Fitting, fixing of scroll motor of indoor unit of Ac systems as per direction of the Engineer-In-Charge.
Replacement of running capacitor as per direction of the Engineer-in-Charge.
Replacement of Starting Capacitor as per direction of the Engineer-in-Charge.
Providing & fitting fixing of PCB Circuit as per direction of the Engineer-in-Charge.
Providing fitting Fixing of MS Platform for placement for condensing unit by using MS Angle of (50*50*5) mm size base plate /cradle with necessary nuts & bolts etc in/c painting , fitting fixing grouting by cement mixture as per direction of the Engineer-In-Charge.
Providing hard PVC pipe of good quality of 25 mm size diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
Dismantling & storing at site of Split AC machine as per direction of the Engineer-in-Charge.
Re-installation of Split AC machine as per direction of the Engineer-in-Charge.
Providing and installation of new DC fan motor of indoor unit by replacing old one as per direction of the Engineer-in-Charge.
Repairing of outdoor fan motor unit as per direction of the Engineer-in-Charge.
Repairing of PCB circuit of indoor unit as per direction of the Engineer-in-Charge.
Providing & fitting fixing of hermetically sealed condenser unit for 1.5 TR capacity split type AC machines replacing old one as per direction of the Engineer-in-Charge.
Providing & fitting fixing of hermetically sealed condenser unit for 1.5 TR capacity split type AC machines replacing old one as per direction of the Engineer-in-Charge.
Providing & fitting fixing of hermetically sealed condenser unit for 2.0 TR capacity split type AC machines replacing old one as per direction of the Engineer-in-Charge.
Providing and fitting fixing of Inverter Compressor (1.5) TR capacity Split type AC's as per direction of the Engineer-in-Charge.
Providing and fitting fixing of Inverter Compressor (2.0) TR capacity Split type AC's as per direction of the Engineer-in-Charge.
Charging fresh refrigerant gas for Split type Inverter AC's as per direction of the Engineer-in-Charge.
Providing fitting fixing of PCB circuit of Inverter AC (1.5/2.0 TR) as per direction of the Engineer-in-Charge.
Providing fitting fixing of indoor fan motor of split AC (1.5/2.0 TR) capacity as per direction of the Engineer-in-Charge.
Providing , fitting fixing of the following spare parts:
Capacitor 2.5 mfd
Capacitor 4 mfd
Capacitor 6 mfd
Capacitor 25 mfd
Capacitor 36 mfd
Capacitor 45 mfd
Capacitor 50 mfd
Capacitor (80-120) mfd
Terminal Clip
PVC tape ( Black tape)
Thermostat
Air Filter (Coir)
Starting relay
SHIV SAKTI REFRIGERATION
R.P.ELECTRONICS
S.D Refrigeration
ASHIRBAD REFRIGERATION
stage.html
html • 0.05 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_34786.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .