Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.1 LAccepted-AOC MOHANPURA MAHAMMADPUR SOUTH CIVIL LINES PO MILAP NAGAR ROORKEE 247667 | ROORKEE | HARIDWAR | UTTARAKHAND | 247667 | L1 | Accepted-AOC L1 | |
| 2 | L2₹8.6 L+₹50,576 (6.24%)Rejected-AOC DEHRADUN | DEHRADUN | UTTARAKHAND | 248001 | L2 | Rejected-AOC L2 | |
| 3 | L3₹8.6 L+₹50,992 (6.30%)Rejected-AOC D 89 SHASTRI NAGAR MEERUT 250004 | MEERUT | UTTAR PRADESH | 250004 | L3 | Rejected-AOC L3 | |
| 4 | L4₹8.9 L+₹83,149.43 (10.3%)Rejected-AOC | L4 | Rejected-AOC L4 |
Tender Value
₹10.0 L
EMD Value
₹19,980
Closing Date
29 Jan 2020, 6:00 pmClosed
Kashi Prasad IDSE
S R Bhatt
PROVN OF COMPOUND WALL OF BLDG NO 461 OF ASCE AND PROVN OF LED LIGHTS 40W VAP 10 NOS INCLUDING ELECTRIC POLES AND ALLIED WORKS IN MT AND GUN PARK OF 262 FD REGT AND CERTAIN MINOR WORK AT RAIWALA UNDER AGE I RAIWALA
2019_MES_306721_2
8810/E8
Open Tender
Civil Works
Item Rate
180 days
Raiwala
AS per tender documents
8 documents required · 8 mandatory
₹500
Yes
AGE(I) Raiwala
₹19,980
Yes
11 Feb 2020
13 Jan 2020
30 Jan 2020
13 Jan 2020
29 Jan 2020
18 Jan 2020
Amount
Excavation in trenches, n.exc 1.5 m wide and n.exc 1.5 m in depth for foundation etc n.exc 10 sqm on plan and getting out in hard/dense soil.
M&L for PCC 1:3:6 type C-2 (40 mm graded aggregate) as in foundations, filling and mass concrete all as specified.
M&L for brick work with sub class 'B' bricks, straight or curved on plan exc 6 m mean radius built in CM 1:4 complete all as specified and directed.
M&L for rendering 15mm thick on fair faces of brick work or concrete surfaces in CM 1 : 4 finishing fair & even without using extra cement
M&L for providing pre-cast cement concrete louvers and jallies type B0 1:2:4 (12.5mm graded aggregate) 25mm thick ( measured solid) including all mouldings set in CM 1:6.complete all as specified and directed.
M&L for two coats of cement base paint over a coat of primer including preparation of newly plastered surfaces complete all as specified including preparation.
Returning, filling in, including spreading, levelling, watering and well ramming in layers n.exc 25 cm in hard/dense soil complete all as specified and directed.
Removing excavated material exc 250 m and n exc 500 m depositing where directed at a level n.exc 1.5 m above the starting point
M&L RCC Type B1, 1:2:4 (sing 20 mm Graded stone aggregate) cast in situ in lintels up to 1.5 M span,cills and other similar bends ,plinth courses, parapets, coping, bed plates and the like including wethering , slightly rounded or chamfered angles and throating as directed including use and waste of form work.
S&F mild steel TMT bars 10 mm dia and over, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding witgh and including mild steel wire (annealed not less than 0.9 mm dia or securing with clips.
E/M PORTION Excavation in trenches, not exceeding 1.5 metre wide and not exceeding 1.5 metre in depth for poles, laying of electric cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and as directed.
Excavation in trenches, exceeding 1.5 metre wide but exceeding 1.5 metre in depth for poles, laying of electric cable and GI tubing (where provided for protection of cables) and getting out trimming the sides, forming bottom surface to required level in any type of soil complete all as specified and as directed.
Returning, filling in , including spreading, leveling, watering and well ramming in layers not exceeding 25 centimetre thick after laying and testing of cable complete all as specified and as directed.
Removing excavated material not exceeding 50 metre and depositing where directed at a level not exceeding 1.5 metre above the starting point complete all as specified and as directed.
Material and labour for Brick protection with sub class ‘B’ bricks old size, laid dry, flat over cable, perpendicular across the cable in trenches complete all as specified and as directed.
Material and labour for Sand cushioning with layer of fine sand 80 mm thick before laying of cable and 150 mm thick after laying of cable in trenches complete all as specified and as directed.
M &L for Cement concrete Type B2 1:2:4 (40 mm in graded aggregate) foundations,filling and mass concrete for foundation and cassing of pole complete all as specefied and directed.
M &L for Cement concrete Type C2 1:3:6 (40 mm in graded aggregate) foundations,filling and mass concrete for copping of pole complete all as specefied and directed.
S&F Pipe galvanised light grade of size 80mm dia light grade including all fittings laid in trenches and wall and floors etc complete all as specified and directed.
S&F Pipe galvanised light grade of size 40mm dia light grade including all fittings laid in trenches and wall and floors etc complete all as specified and directed.
Supply and fixing street light junction box IP -43 all weather proof non corrosive including 06 Amp MCB SPN and provisoin of fixing digital timer switch complete all as specefied and as directed by engr -in- charge. Make:- Sintex/Havells/crompton/Bajaj
S&F LED street light of capacity 40 Watt made up of pressure die cast aluminium housing with high power LED as lighting source and lense embedded PC with impact resistance of IK 07 with 10kv bulit in surge protection device with isolated electronic LED driver ( SMPS based constant current supply ) with lower THD output open / short circuit protection , over voltage protection , phase to phase protection upto 440 V and other safety test as per IS -15885 Part 2/ Sec 13 and Power factor ≥0.95 , THD ≤10% Colour temp 5700K , IP 66 , CRI ≥ 70 system lumen 3500 lm and working voltage range 140V to 270 V with efficay>105 lm/w and optics as per LM 79 with one year warranty as given by the company along copper multistrand FRLS connection from MCB all as specified and directed by Engr-in-Charge. Make : Crompton Cat part No LSTS-40 -CDL or Equivelent to SURYA ,Havells, Philips.
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 6.0 sq mm 2 core
Supply, laying and testing cable XLPE Insulated ,screened, PVC bedded, galvanized steel strip or wire armoured, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor of size 10.0 sq mm 2 core
Supply and fix steel tubular swaged poles type 410 SP-31 (9.00 meter long) complete with CI base plateincluding Painting to LT MS tubuler Pole having length 6.5 mtr approx from top of pole one coat of red oxide primer with two coats of synthetic enamell aluminium paints and 1.2 mtr height from ground level in alternate band of white and black with synthetic enamel paint complete all as specified and directed.
M&L cross arms , bracings supports clamps and back plates fabricated incuding nuts , bolts ,washers , welding ,bending cold or hot. Drilling holes for bolts in any shape or size as indicated or directed and inclusive of one primer coat , one under coat , one under coat , one under coat and one finishing coat of paint .
Supply and fixing Digital time switches programmable every 1 min , with backup 6 years , 28 memory locations , current capacity 16 A weekly program , with cangeover ( 1CO total 28 programs complete all as specefied and as directed by engr -in- charge. Make:- Indoasian Model No DIN Type Daily / weekly with 1 CO Cat part no TDA43110 or equivalent make in Legrand / hager.
M & L for point wiring with PVC unsheathed, fire resistance, stranded copper conductor of size 1.5 sqmm (nominal cross sectional area ) single core cable in and including concealed (surface only on roof & colomns) wiring incl PVC conduit medium grade, ISI marked, 20 mm or higher dia complete with all accessories/fittings and sunkan MS boxes of thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, complete all as specified & directed for One light /fan /bell /exhaust fan point controlled by one, one way 5/6 switch.
S & F switch piano flush type white /ivory finish 5/6 Amps, single pole one way complete all as specified & directed.
S & F Exhaust fans AC single phase 230/ 240 V of size 300 mm sweep. Make Havells Ventil Air -DB
S & F Heavy duty Exhaust fans AC single phase 230/ 240 V of size 450 mm sweep 900 RPM. Make Havells
S & F ceiling rose surface Bakelite AC 220/240 volts 3 terminals complete all as specified & directed.
M & L for cutting holes into brick walls built in cement mortar and stone walls built in lime mortar and making good in cement mortar 1:3 or cement concrete 1:2:4 type B1 as required with superficial area ex 150 sq.cm but n.ex 400 sq.cm for exhaust fan complete all as specified and directed.
S & F Water heater storage type, electric,capacity 25 litres.BEE 5 star rated complete all as specified & directed.Make Bajaj Shakti GPV SWH ABS body or equivalent in approved makes.
M & L for point wiring with PVC unsheathed, fire resistance, stranded copper conductor of size 2.5 sqmm (nominal cross sectional area ) single core cable in and including rigid non metalic PVC conduit 20 mm dia or higher size "medium " grade ISI marked concealed (surface only on roof & colomns) complete with all accessories/fittings and MS box thickness not less than 1.2 mm covered with 3 mm thick plastic laminated hard glassy surface sheet cover concealed in wall with brass screws & washers including unsheathed single core PVC insulated cable green in colour 1.5 sqmm stranded copper conductor as earth wire and connecting to earth dolly, for one three /six pin 15/16 amps power socket controlled by one 15/16 amps switch complete all as specified & directed.
S & F switch piano flush type white /ivory finish 15/16 Amps, single pole one way complete all as specified & directed.
S & F 240 Volt single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 20A.
S & F necessary connecting items for making geyser water supply connection from the exisiting 15 mm GI pipeline including hot water PVC connection(02 No.), necessary 15 mm GI pipe medium grade from exisiting water supply to geyser and two nos of 15 mm Stop cocks and one no of cromimum plated tap with inculding all fittings and fixtures to install geyser on cemented / brick wall all as specified and directed .
S & F Desert Cooler Plastic body , AC single phase 230/ 240 V of size 4000cfm including copper winded pump and motor complete all as specified and as directed Make :- Bajaj/Havells/Crompton
S & F Sheet metal encloser DBs when MCBs to be used 4 Way 240 volt complete all as specified and as directed.
S & F MCBs SP 240 volt 6 to 32 amp complete all as specified and as directed.
S & F MCBs SPN 240 volt 6 to 32 Amp complete all as specified and as directed.
S & F ceilling fans, AC single phase 230/ 240 V of size 1200 mm sweep 5 star rating of Make :- Bajaj/Havells/Crompton
M& L for earthling complete with galvanized steel earth plate, electrode 600 x 600x6 mm thick , buried directly under ground (earth pit not less than 2.25 m below ground level ) with top edge of the plate not less than 1.5 below ground level connected to galvanized earth wire 4.0 mm dia by means of nuts, bolts, check nuts & washers, of galvanized iron or steel all as Shown in electrical plate No 5 connected to main switch board, including all necessary excavation & earth work in hard/dense soil, common salf and charcoal dust mixed & packed 150 mm thick homogeneous layer all around the GI earth plate, earth pit chamber made out of cast iron frame with hinged door , GI protection pipe light grade upto 7.5 meter from electrode complete all as specified & shown on drawings with watering pipe including GI wire connect to poles.Note :- (1) Earth lead and GI pipe light grade 15 mm dia for protection against mechanical damage beyond 7.5 mtr from electrode to earth terminal point/main switch board. Etc shall be measured separately . (2) On testing, after completion of Job , if desired earth resistance is not obtained, the earthing shall be redone at no extra cost to contractor.
TARUN ENGINEERING WORKS
mohanlal gupta
national engineers and associates
stage.html
html • 0.05 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .