Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹18.8 LAccepted-AOC JOYNAGAR MIDDLE ROAD AGARTALA PIN 799001 | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | L1 | Accepted-AOC L1 | |
| 2 | Rejected-Technical NEAR RAMNAGAR ROAD NO 2 TG ROAD AGARTALA WEST TRIPURA | WEST TRIPURA | TRIPURA | 799002 | - | Rejected-Technical RES | |
| 3 | Rejected-Technical 31 A K ROAD AGARTALA | AGARTALA | WEST TRIPURA | TRIPURA | 799001 | - | Rejected-Technical RES |
Tender Value
₹22.9 L
EMD Value
₹45,859
Closing Date
25 Jan 2024, 3:00 pmClosed
Executive Engineer, Mechanical Division,PWD, Aga
Executive Engineer, Mechanical Division,PWD, Agartala
Providing, Installation and Commissioning of Air Conditioning Machines at the residences and quarters of the VIPs of Govt. of Tripura for the S.P.Mukherjee lane, Rabindra Palli and adjoining areas during the year of 2023 24
2024_CEPWD_45999_1
62/EE/DNIeT/MECH.DIVN/AGT/2023
Open Tender
Electrical Works
Works
730 days
AGARTALA
Please refer Tender documents.
6 documents required · 6 mandatory
₹1,000
₹45,859
18 Jul 2024
16 Jan 2024
25 Jan 2024
16 Jan 2024
25 Jan 2024
16 Jan 2024
Amount
Providing of Split type High wall 2.00 TR (rated cooling capacity should not be less than 6,000 Kcal/ hr or 24000 BTU/hr or 7000 KW) split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must be of pure copper) not less than 3 (Three) Star rating (latest Standard),operates on Single Phase 230 volt, 50Hz, AC Supply maximum current drawn 11.0 ampere, including supply of 3.0 Mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (Four) core electrical connecting cable, Remote control unit in/c batteries,16 amps power Top etc complete, capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.
Providing of Split type High wall 1.50 TR (rated cooling capacity should not be less than 4500 Kcal/ hr or 18000 BTU/hr or 5250KW) split A.C. Machine with Inverter Compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for wall mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must be of copper pipe) not less than 3 (Three) Star rating (latest Standard),operates on Single Phase 230 volt, 50Hz, AC Supply maximum current drawn 8.50 ampere including supply of 3.0 Mtr copper pipe (both for suction & liquid line), 3.0 mtr 4 (Four) core electrical connecting cable, Remote control unit in/c batteries,16 amps power Top etc complete, capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge.
Providing of Cassette type split A.C Machine with inverter compressor technology operating on non-CFC refrigerant (R-410A/R-32/equivalent refrigerants) suitable for ceiling mounting conforming to IS:1391 (Part-II) specification (Evaporator & Condenser must have copper pipe) suitable for operation on 230 volt +- 10%, not less than 3 (Three) Star rating , 50Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. 2.0TR (minimum 6000 kcal/hr)
Providing of Split type High wall AC Machine with heat pump ( Condenser and evaporator pipe should be made of copper) with hermetical; y sealed Inverter Compressor suitable for refrigerant confirming to IS 1391 (part-2) specification (except power consumption ) suitable for operating on 230 volt +-10% ,not less than 3 (Three) Star rating , 50Hz, Single Phase AC Supply capable of performing a) Cooling b) Dehumidifying c) Air Circulation d) Filtering as per direction of the Engineer-in-Charge. 2.0TR (minimum 6000 kcal/hr)
Standard installation ,testing and commissioning including necessary cement plastering of holes of 1.5 TR/2.00 TR capacity High Wall Split type Air Conditioning machine /2.0TR stand (Vertical) Air Conditioning machine.
Standard installation,testing and commissioning of 2.00 TR capacity Cassette type Split Air Conditioner.
Fabrication of M.S. platform for placement of condensing unit( outdoor unit) by using M.S. angle of (50x50x5) mm size base plate, nuts & bolts or cradle of suitable sizes i/c painting, fitting, fixing grouting by cement mixer as per direction of the Engineer-in-Charge.
Supply and installation of additional length of copper pipe of suitable diameter for suction and liquid line with installation and necessary wiring between between indoor and outdoor units beyond the standard length as per direction of the Engineer-in-Charge.
Supply installation testing and commissioning including vaccumization and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRF/VRV system, complete with fittings, with suitable adjustable ring type hanger supports, jointing /brazing including accessories insulated with XLPE Class O tubular insulation/with Class O closed cell elastomeric nitrile rubber tubular sleeves sections of specified thickness as below for Suction and Liquid lines, all accessories as per specification etc as required:
6.4 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
9.5 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
12.7 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
15.86 mm dia (OD) (soft drawn) with tube thickness 1.2 mm with 19mm thick insulation
19 mm dia (OD) (Hard drawn) with tube thickness 1.2 mm with 19mm thick insulation
Providing hard PVC pipe of best quality of suitable diameter including necessary clamping and fitting for draining of condensate water from indoor unit as per direction of the Engineer-in-Charge.
Providing and connecting Electric Control cables between MCB to indoor/outdoor. A) 3 core minimum 2.5 Sq. mm Copper Cable.
STANDARD ELECTRONICS
Eastern Commerce
stage.html
html • 0.04 MB
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_46745.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .