| 1 | SITC of 1.5 TR Capacity split AC | SITC of 1.5 TR, Minimum cooling capacity 17000 BTU/Hr , Hi-wall mount, Cold type, BEE rated 5 STAR Split type Air conditioner with inverter type compressor filled with R410a/ R32 gas, copper condensor tube/coil, cordless remote control for temperature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode, turbo mode, with LED display for temperature and other standard features suitable for operation on 230 V, 50 Hz , AC supply including wiring with suitable size FR, PVC flexible copper cable for control/power wiring, Suction and liquid line copper piping between indoor and outdoor unit (approx distance of 10 ft) with insulation as per technical specifications etc complete as required. | 8 | Each | [email protected] | 60 |
| 2 | SITC of 2.0 TR Capacity split AC | SITC of 2.0 TR, Minimum cooling capacity 20000 BTU/Hr , Hi-wall mount, Cold type, BEE rated 5 STAR Split type Air conditioner with inverter type compressor filled with R410a/ R32 gas, copper condensor tube/coil, cordless remote control for temperature adjustment, indoor unit blower speed, swing adjustment, auto restart, sleep mode, turbo mode, with LED display for temperature and other standard features suitable for operation on 230 V, 50 Hz , AC supply including wiring with suitable size FR, PVC flexible copper cable for control/power wiring, Suction and liquid line copper piping between indoor and outdoor unit (approx distance of 10 ft) with insulation as per technical specifications etc complete as required. | 5 | Each | [email protected] | 60 |
| 3 | | Dismantling of existing 1.5 TR Nominal capacity window type AC from installed location to shift to another location and submission it to AAI as per direction of E.I.C etc complete as required. | 8 | Each | [email protected] | 60 |
| 4 | | Dismantling of existing 2.0 TR Nominal capacity split type AC from installed location to shift to another location and submission it to AAI as per direction of E.I.C etc complete as required. | 4 | Each | [email protected] | 60 |
| 5 | Supply and fixing of AC Stand | Supply and fitting of appropriate size and thickness of MS Stand / L-Chair for fixing 1.5/2.0 TR split AC outdoor unit or condensing units along with necessary vibration pads , anchor fastner/bolt & nuts etc on concrete/brick wall or floor etc. as required. | 13 | Each | [email protected] | 60 |
| 6 | Supply and fixing of copper refrigerant pipe | Supply & fixing of extra copper refrigerant piping with insulation and suitable size FR , PVC copper cable for control/power wiring between indooor and outdoor units for installation of above units etc as required at site. | 20 | Mtr | [email protected] | 60 |
| 7 | Supply and fixing of drain pipe | Supply and fixing of PVC drain piping of proper dia for installation of above units as required at site beyond company provided standard length. | 40 | Mtr | [email protected] | 60 |
| 8 | SITC of Voltage stabilizer for 2.0 TR Ac | Supply, Installing, Testing and Commissioning of 5 KVA voltage Stabilizer suitable for 2.0 TR Split AC unit having stabilising range (170-280 V), Digital display showing input and output voltage, Time delay system , Low & High Voltage Cut-off Protection, Built In Thermal Overload Protection, wall mounting cabinet design and other standard functions including providing connections etc. complete as required. | 5 | Each | [email protected] | 60 |
| 9 | SITC of Voltage stabilizer for 1.5 TR Ac | Supply, Installing, Testing and Commissioning of 4 KVA voltage Stabilizer suitable for 1.5 TR Split AC unit having stabilising range (170-280 V), Digital display showing input and output voltage, Time delay system , Low & High Voltage Cut-off Protection, Built In Thermal Overload Protection, wall mounting cabinet design and other standard functions including providing connections etc. complete as required. | 8 | Each | [email protected] | 60 |
| 10 | SITC of AC controler timer | SITC of Timer, bassed on Micro control technology, for control two nos AC, programmable, LCD display, Automatic override facility to second AC if running AC fails, Input 230V AC +/- 15%, 50 HZ, Contact rating 30A at 230V, change over time delay range upto 01-12 hours (site selectable switch),complete as required. | 2 | Each | [email protected] | 60 |