Loading…
Loading…
Tender ID
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.5 LAdmitted-Finance BANIKHET NAVEEN KUMAR BANIKHET CHAMBA HIMACHAL PRADESH 176303 | CHAMBA | HIMACHAL PRADESH | 176303 | L1 | Admitted-Finance | |
| 2 | L2₹1.5 L+₹1,416.90 (0.93%)Admitted-Finance C O NIDHI MEDICAL STORE LAKKAR BAZAR SHIMLA 01 | SHIMLA | HIMACHAL PRADESH | 171001 | L2 | Admitted-Finance | |
| 3 | L3₹1.6 L+₹3,117.18 (2.04%)Admitted-Finance VILL CHANDERYAR PO SADHOT TEHSIL DHARAMPUR DISTT MANDI H P | L3 | Admitted-Finance |
| Sl No | Description | Qty | Unit | Pankaj L3 | Naveen Kumar L1 | Roshan Lal L2 |
|---|---|---|---|---|---|---|
| 1.00 | Complete Removal & Cleaning of base of tank / walls from sludge & slurry deposited on surface & Base of tank. Cleaning of Complete Concrete Inner surface by throughly brooming with wire brush and surface grinder to remove the sludge depositions, algae, dirt and all type of foreign material deposited on all inner surfaces of tank. Removal of residual water from the base of tank. | 94.46 | Sqm | 90 ₹8,501.4 | 83 ₹7,840.18 Lowest | 85 ₹8,029.1 |
| 2.00 | Chiselling/ Drilling of all wall & base joints inside Water tank to remove fatigued surfaces & capiliaries leading to water seepages.Developing coved surface [ goal formation] on entire base & wall joint inside tank areas for leakage protection & strengthening.. Application of plaster with PIDILITE URP 301 compound on entire surface area after removal of fatigued concrete to a minimum thickness of 3 mm on entire surface area of tanks. Developing coved surface [ gola formation ] on entire wall and base joints for additional strengthening against leakages. Installation of fibre mesh on entire surface of tank with Pidilite URP mixture. Application of Fosroc Priming agent followed by Micr-concreting the entire surface for leagake protection . After Micro concreting the entire surface is coated with Fosroc Rendroc plug for water tighting the concrete, | 94.46 | Sqm | 480 ₹45,340.8 | 473 ₹44,679.58 Lowest | 477 ₹45,057.42 |
| 3.00 | Installation of fibre mesh on entire surface of tank with Pidilite URP mixture.WATER PROOFING & SEEPAGE PROTECTION CEMENTITIOUS ELASTOMERIC FOOD GRADE COATING PIDILITE MAKE FASTFLEX TO BE DONE ON ENTIRE INNER SURFACE AREA OF STORAGE TANK IN TWO LAYER SYSTEM , ONE COATING LAYER TO BE PERPENDICULARLY COATED ON THE SECOND LAYER. AFTER DRYING OF FINAL LAYER BUFFER LAYERING TO BE DONE AT WALL & BASE JOINT AREAS TO PROVIDE ADDITIONAL COATING STRENGTH. | 94.46 | Sqm | 1,082 ₹1,02,205.72 | 1,063 ₹1,00,410.98 Lowest | 1,072 ₹1,01,261.12 |
Tender Value
₹1.5 L
EMD Value
₹3,050
Closing Date
9 Mar 2026, 5:00 pmClosed
Executive Engineer
JS Division Dharampur Bharari
RM of LWSS Proh ka Galoo in GP Sidhpur Tehsil Dharampur Distt. Mandi HP
2026_HPIPH_129798_1
16121-71 Dated 27-02-2026
Open Tender
Civil Works
Item Rate
Dharampur
Please refer Tender documents.
8 documents required · 8 mandatory
₹500
₹3,050
20 Mar 2026
28 Feb 2026
10 Mar 2026
28 Feb 2026
9 Mar 2026
28 Feb 2026
Complete Removal & Cleaning of base of tank / walls from sludge & slurry deposited on surface & Base of tank. Cleaning of Complete Concrete Inner surface by throughly brooming with wire brush and surface grinder to remove the sludge depositions, algae, dirt and all type of foreign material deposited on all inner surfaces of tank. Removal of residual water from the base of tank.
Chiselling/ Drilling of all wall & base joints inside Water tank to remove fatigued surfaces & capiliaries leading to water seepages.Developing coved surface [ goal formation] on entire base & wall joint inside tank areas for leakage protection & strengthening.. Application of plaster with PIDILITE URP 301 compound on entire surface area after removal of fatigued concrete to a minimum thickness of 3 mm on entire surface area of tanks. Developing coved surface [ gola formation ] on entire wall and base joints for additional strengthening against leakages. Installation of fibre mesh on entire surface of tank with Pidilite URP mixture. Application of Fosroc Priming agent followed by Micr-concreting the entire surface for leagake protection . After Micro concreting the entire surface is coated with Fosroc Rendroc plug for water tighting the concrete,
Installation of fibre mesh on entire surface of tank with Pidilite URP mixture.WATER PROOFING & SEEPAGE PROTECTION CEMENTITIOUS ELASTOMERIC FOOD GRADE COATING PIDILITE MAKE FASTFLEX TO BE DONE ON ENTIRE INNER SURFACE AREA OF STORAGE TANK IN TWO LAYER SYSTEM , ONE COATING LAYER TO BE PERPENDICULARLY COATED ON THE SECOND LAYER. AFTER DRYING OF FINAL LAYER BUFFER LAYERING TO BE DONE AT WALL & BASE JOINT AREAS TO PROVIDE ADDITIONAL COATING STRENGTH.
stage.html
html • 0.03 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.03 MB
Tendernotice_1.pdf
PDF • 0.59 MB
Form6.pdf
Tender Documents • 0.82 MB
Form8.pdf
Tender Documents • 1.28 MB
BOQ_191858.xls
BOQ • 0.27 MB
TC.pdf
Tender Documents • 0.13 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .