| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹230.1 CrAccepted-AOC | ₹230.1 Cr | L1 | Accepted-AOC Since L1 |
| 2 | L2₹233.3 CrRejected-Finance | ₹233.3 Cr | L2 | Rejected-Finance Not L1 hence rejected |
| 3 | L3₹233.4 CrRejected-Finance | ₹233.4 Cr | L3 | Rejected-Finance Not L1 hence rejected |
| 4 | L4₹248.6 CrRejected-Finance | ₹248.6 Cr | L4 | Rejected-Finance Not L1 hence rejected |
| 5 | L5₹263.0 CrRejected-Finance EN 62 7TH FLOOR SALTLAKE CITY KOLKATA SECTOR V WEST BENGAL 700091 | 24 PARAGANAS NORTH | WEST BENGAL | 700091 | ₹263.0 Cr | L5 | Rejected-Finance Not L1 hence rejected |
Tender Value
₹213.1 Cr
EMD Value
₹15 L
Closing Date
18 Jan 2022, 6:00 pmClosed
DDG AND CE
DGNP Naval Base post Visakhapatnam 530014
PROVISION OF EXTERNAL ELECTRIC SUPPLY AND OTHER ALLIED WORKS
2021_MES_486428_1
DDGCE TOKEN 05 OF 2021 2022
Open Tender
Civil Works
730 days
VISAKHAPATNAM
As per NIT
8 documents required · 8 mandatory
₹3,000
DGNP
₹15 L
Yes
DDG CE Conference Hall
22 Mar 2022
5 Nov 2021
20 Jan 2022
5 Nov 2021
18 Jan 2022
10 Jan 2022
5 Nov 2021 - 25 Nov 2021
18 Nov 2021
Amount
Lump sum amount worked out by the contractor for "Buildings & Structures" as listed in Schedule 'A' Part-I on Serial Page No. 45
Lump sum amount worked out by the contractor for "Site Clearance / Area Development / Earthwork excavation" as listed in Schedule 'A' Part-II on Serial Page No. 46
Lump sum amount worked out by the contractor for "Pile Foundation and RCC Duct" as listed in Schedule 'A' Part-III on Serial Page No. 49
Lump sum amount worked out by the contractor for "Internal Water Supply" as listed in Schedule 'A' Part-IV on Serial Page No. 50
Lump sum amount worked out by the contractor for "Internal Electrification" as listed in Schedule 'A' Part-V on Serial Page No. 52
Lump sum amount worked out by the contractor for "External Electrification" as listed in Schedule 'A' Part-VI on Serial Page No. 56
Lump sum amount worked out by the contractor for "Lightning Protection" as listed in Schedule 'A' Part-VII on Serial Page No. 57
Lump sum amount worked out by the contractor for "Retaining Wall / Sewage Disposal" as listed in Schedule 'A' Part-VIII on Serial Page No. 58
Schedule "A" Part - IX: [Miscellaneous Items] [Pile Foundation, Internal Water Supply, Internal Electrification, External Electrification, Lightning Protection, DG Set and EOT Crane]: [To be quoted by the bidder.]
M&L for Point wiring with 1.5 Sq.mm FRLSH PVC insulated unsheathed copper conductor cable, single core multi stranded 1100Volt grade confirming to IS 694: 1977, drawn in and including rigid PVC conduit not less than 20mm bore, concealed type, medium grade as per IS 9537 (Part 1-1983) with conduit accessories, junction boxes, tees, terminal boxes with and including concealed pressed steel terminal box of suitable size fabricated out of 2mm thick MS sheet and 3mm thick lminated hylam sheet top cover for fixing switches, switch socket, including one run of 1.5 Sq.mm single core FRLSH PVC unsheathed copper conductor cable as earth continuity conductor and connected to common earth dolly, for one light point controlled by one way switch, complete all as specified and as directed. Note: Cutting chases and making good surfaces shall be included in the unit rate.
Description all as per Serial Item No. 9 here in before but for fan point controlled by one way switches complete.
Description all as per Serial Item No. 9 here-in-before but with 1.5 Sqmm copper conductor cable and 1.5 Sqmm cable as earth continuity conductor for 3 pin 5Amp switch socket point, on independent board, complete all as specified.
Description all as per Serial Item No. 9 here-in-before but for 3 pin 5Amp switch socket point, on Same board, complete all as specified.
Description all as per Serial Item No. 9 here-in-before but with 4.0Sqmm copper conductor cable and 4.0 Sqmm cable as earth continuity conductor for 3 pin 5/15Amp switch socket point, on independent board, complete all as specified.
S&F Wall mounting fan 450mm sweep of approved colour and model, with complete accessories (Energy Efficient) including provision of suitable clamp, flexible cable suitable for 230 Volt, AC 50 Hz, complete all as specified and as directed.
S&F Energy saving, environmentally friendly & robust High bay light LED 80 Watt energy efficient, P.F>0.95, >100 lum/watt, with and including LED light driver holder connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. Make: Cat No. LHELAAU7PG7S080 of Havells or Equivalent in makes given here-in-after.
S&F Decorative luminary suspended type mounting 40/35 watt, 220Volt, P.F>0.95, >100 lum/watt, complete with 30/35 watt, lamp holder, complete made up of polycarbonate, connecting of with three core flexible copper conductor cable of suitable size, complete all as directed by Engr-in-charge. Make Cat. BLRL 35CDMT 35W of Bajaj or equivalent in makes given here-in-after.
S&F LED Building Security light fitting 40Watts, 230 volts, >100lum/W, with Suitable size GI bracket made out of 25/40mm GI pipe fixed with clamps, nuts&bolts etc., complete with IP 65/66 protection with LED lamp, driver, bracket with impact and corrosion resistant and all accessories, complete all as specified and as directed. Make Cat. CIS-300-40-57-SL-DP-NGR for batten and LT8-20-865(2) for tube of Crompton or equivalent in makes given here-in-after.
S&F 15mm dia 2 in 1 Bib cock, fancy type, twin elbow valve faucet wall mounted type, with and including SS health faucet & jet spray with SS flexible tube & hook, complete all as specified and as directed. Make: Cat No. F-330004 for Bib cock and F-160023 for Health Faucet of Hindware or equivalent in makes given here-in-after.
M&L for Earthing complete with galvanised steel earth plate electrode 60cm X 60cm X 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less than 1.5 metres below normal ground level, connected to galvanised earth lead 4mm GI wire by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No.3 of SSR Part-I, including excavation / earth work in any strata, adequate quantity of charcoal and common salt, PCC chamber with with RCC 1:2:4 type B1 40mm thick cover slab with suitable handle and angle iron frame of suitable size to fix the cover, with 20mm bore GI pipe light grade for watering with funnel, wire mesh and 15mm bore GI pipe medium grade for GI wire protection and 4mm GI earth wire, including testing after completion, complete all as specified and directed. Note: Earth wire will be measured after 7.5mtr from the earth strip or earth testing terminal block whichever is lesser under relevant item.
All as per Serial Item No. 19 here in before but with copper plate 60cm×60cm ×3.15mm thick electrode and 20mm×3mm copper strip as earthing lead and 25mm bore GI pipe medium grade as protection pipe.
All as per Serial Item No. 19 here in before but using galvanised iron strip 32 x 6mm earthing lead and 50mm bore GI pipe medium grade as protection pipe. Notes for Serial Item No. 19 to 21: On testing on completion if the desired earth resistance is not obtained the earthing shall be redone at no extra cost.
M&L for Design, Manufacture, supply, testing and commissioning of electrically operated, double girder EOT crane as per IS -807 & IS -3177 with span 6.6mtrs (Apx) having 5Ton capacity and lifting ht 5.0mtrs from floor level, long travel of length 40mtrs with required crane track rail, Speed of main hoist - 3mtr/min, Main Creep Speed - 0.3m/min, Long Creep Speed - 1m/min, Speed of long travel - 10mtr/min, All micro speed will be 1/10 of main speed by all motions, DSL system with PVC sheated copper bus bar for 3 Phase & neutral with earth bus system with locking system & VVF Drive system, push button system, radio remote controlling systems, all safety provisions and audio visual alarm system to all motions, single phase preventer, over load relay, safety siren/over load alarm with and including connection upto DB with suitable cable from panel board to crane and conduit as per site requirement, additional push button system with interlocking wiring with and including all connected accessories like rope drum, steel wire rope, sheaves, pulleys, hydraulic brake, single phase preventer, overload relay, SFU, air brake contactor, main hoist motor, micro hoist motor, long & cross travel motor, lift hook, service platform, walkway with railing, safety latch, load indicator, catwalk along length of crane, ladders, buffers, hooks & clamps on wall etc., complete all as specified and as directed. Note: Span and Long travel may vary slightly as per site condition.
M&L for Earth Grid with GI strip of size 100mm x 10mm, including jointing by riveting/welding as required, laid in trenches / ducts, complete all as specified and as directed.
M&L for Earth Grid with GI strip of size 75mm x 10mm, including jointing by riveting/welding as required, laid in trenches / ducts, complete all as specified and as directed.
M&L for Earth Grid with GI strip of size 50mm x 6mm, including jointing by riveting/welding as required, laid in trenches / ducts, complete all as specified and as directed.
S&F Voltage stabilizer 1KVA for automatic operation, suitable for deep freezers / refrigerator / water cooler / 2 Ton AC, single phase naturally air cooled indoor type and designed for input variation 170V to 250V, output voltage stabilized at 230Volt with accuracy of ± 2.50%, complete all as specified and as directed.
All as per Serial Item No. 27 here in before but for cable size 33KV 3.0core x 300.00Sqmm, complete all as specified and as directed.
All as per Serial Item No. 27 here in before but for cable size 33KV 3.0core x 400.00Sqmm, complete all as specified and as directed.
S&F Cable jointing kit for 33 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm, complete all as specified.
S&F Cable jointing kit for 33 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm, complete all as specified.
S&F Cable jointing kit for 33 KV (Earthed) grade cable for straight through cold shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 240 sqmm to 400 sqmm, complete all as specified.
S&F Cable jointing kit for 132 KV (Earthed) grade cable for indoor termination cold shrink type joint complete with jointing material and accessories suitable for 1C XLPE armoured aluminium conductor cable of size 630 sqmm, complete all as specified.
S&F Cable jointing kit for 132 KV (Earthed) grade cable for outdoor termination cold shrink type joint complete with jointing material and accessories suitable for 1C XLPE armoured aluminium conductor cable of size 630 sqmm, complete all as specified.
Design, Supply and fixing sandwich type bus trunking system, OEM design with separate bus bar for earth where ever requires bus trunking system with aluminium busbar 2000Amp, 40kA breaking capacity, IP-54 protection, 440Volt, complete all as specified and as directed.
Design, Supply and fixing sandwich type bus trunking system, OEM design with separate bus bar for earth where ever requires bus trunking system with aluminium busbar 4000Amp, 40kA breaking capacity, IP-54 protection, 440Volt, complete all as specified and as directed.
Supply, fix, test and commission of HT isolator with center break, out door electrically operated, 2500 Amps, 40 KA for 3 secs, of nominal system voltage : 132 kV, Highest system voltage : 145 kV, System frequency : 50 Hz, 3 Phase, System neutral shall be effectively earthed, Isolator and earth switch both working manually and electrically, with Auxiliary Electrical equipment/contacts, electrically interlocking with circuit breaker, Mechanism neutral grounded, Center break, outdoor ELECTRICALLY gang operated etc., complete all as as per IS-9921, complete all as specified and as directed.
Supply, install, test and commission of lightning arrestor single pole made of porcelain brown glazed, heavy duty station class, gapless, zinc oxide type (non linear) fitted with pressure relief device, arc diverting ports, grading/corona rings, discharge counter with ammeter, mounting insulator complete all as specified and as per IS 3070 (Part I) and with following parameters:- Makes: ABB / CG / SIEMENS
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 300 KVAR with capacitor banks (25KVARx2Nos+50KVARx5Nos) steps with ACTIVE HORMONIC FILTER, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 400 KVAR with capacitor banks (25KVARx2Nos+50KVARx7Nos) steps with ACTIVE HORMONIC FILTER, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 540 KVAR with capacitor banks (20KVARx2Nos+25KVARx2Nos + 50KVARx9Nos) steps with ACTIVE HORMONIC FILTER, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 160 KVAR with capacitor banks (5KVARx3Nos+10KVARx2Nos+25KVARx3Nos + 50KVARx1No) steps with ACTIVE HORMONIC FILTER, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 100 KVAR with capacitor banks (5KVARx1No + 10KVARx2Nos + 25KVARx1No + 50KVARx1No) steps with ACTIVE HORMONIC FILTER, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Design, Supply, install test and commissioning of Automatic Power Factor Correction (APFC) Panel for 3 Phase, 415 V & 50 Hz system of capacity 50 KVAR with capacitor banks (5KVARx1No+10KVARx2Nos+25KVARx1No) steps with ACTIVE HORMONIC FILTER, APFC relay, suitable capacitor banks with MCB/MCCBs/ACB having standard components & accessories, compleete all as specified and as directed.
Supply, lay, test and commissioning of one run of minimum 6 Fibre OFC cable with and including 40mm HDPE duct pipe with and including all its connected accessories, laid in trenches or ducts or through the pipe etc., complete all as specified and as directed. Note: One run of Cable and one run of duct Pipe shall be measured as one RM.
Supply, fix and testing of Loop in Loop Junction box of size 4"x 8" of FRP made with IP 65 protection of thermoplastic circuit breaker boxes with metric knockouts for cable entry and exit, comb climate Cable Glands of IP66/IP67 for cable entry and Grommets IP 65 for conduit for cable exit with MCB 6 Amps, 10KA, C Curve overload and short Circuit protection, with 4 way connector, terminals as bus terminals for cable with necessary fixing arrangements and with cable glands etc all as specified and directed.
M&L Boring of holes under road, pavement, hard standing by trenchless technology using ultra sound technique and necessary machine with and including HDPE pipe of 150mm dia suitable for 6 KGF/Sq.cm working pressure, complete all as specified and as directed.
M&L for Cable route indicator for cable route marker, made out of cast iron round shape of 100mm dia, with supporting length of MS angle 40x40x6mm and 750mm long fixed with nuts & bolts, duly marked with word such as HT Cable 11KV or 33KV as directed, duly painted with two coats of super enamel silver colour over a coat of primer, including grouting in ground 300mm x 300mm x 300mm deep with and including PCC 1:2:4 (Type B1), complete all as specified and directed.
M&L for Galvanized Steel High mast light 16m height, mast shaft with hot dip galvanized, suitable for wind velocity of 198Km/hour and soil bearing capacity of 20 TON/Sqm as per IS-875, 3mm section thickness with top 150mm dia and bottom 340mm dia, suitable for 8 lantern symmetrically fitted along with their control gear and having two point suspension system with stainless steel wire rope of 6mm dia, 97/19 gauge and double drum winch with luminaire mounting arm, pulley assembly, galvanised carriage arrangement for 8 lights, 3 phase integral power tool with motor for lifting and lowering, lightning arrester spike, with foundation bolts manufactured from special steel along with nuts, washers, anchor plates, control panel with control cable, outdoor standard feeder pillar with 32A TPN MCB incomer, single dial time switch, 25A TP Contactor for automatic operation of luminaries, power tool control with 2 Nos Contacts and raise lower push button, switch gears and templates, with all accessories, including excavation, earth work, RCC M30 foundation as per OEM recommendations, complete all as specified and as directed. Note: Light fittings will be measured and paid for separately. Make: Cat No. BHMRL 16E of Bajaj or Equivalent in makes given here-in-after.
Supply, laying, testing and commissioning of FRLSH PVC insulated sheathed, multi standard, copper conductor cable of size 3.0 core x 1.5Sqmm, 1100 volts grade and including cable glands, ferrules and connected accessories, multi stranded 1100 Volt grade confirming to IS 694: 1977, complete all as specified and as directed.
Supply, laying, testing and commissioning of FRLSH PVC insulated sheathed, multi standard, copper conductor cable of size 4.0 core x 1.5Sqmm, 1100 volts grade and including cable glands, ferrules and connected accessories, multi stranded 1100 Volt grade confirming to IS 694: 1977, complete all as specified and as directed.
S&F Hot dip Galvanised perforated cable tray with cover for fixing XLPE cables at various places to accommodate the cables for MCBs, Panel etc of size not less than 300X150mm, 2mm thick with necessary bends, angles, supports for fixing etc., complete all as specified and as directed.
S&F Compact type Timer Panel of capacity 6KW including of Power contactor of 32Amp TP, MCB 40 Amps TP and Digital Timer switch 415Volt, steel enclosure, complete all as specified.
Supply, Installation, testing & commissioning of fully type tested HT 33KV, 25 kA, Line VCB panels switchboard consisting of 2 Incoming 1250 Amps VCB and 1 NO 1250 Amp Buscoupler with 8 Nos 800Amp outgoing VCBs, VCB panel indoor type totally enclosed, free standing floor mounting type, compartment based with truck mounted vacuum circuit breaker spring operated electrically and manually charged operating mechanism suitable for horizontal isolation, horizontal draw out type VCBs with copper bus bars, Self supported Insulated Busbar with full voltage rated shall be used. The switchgear panel shall be of sheet steel construction with Aluminum Zinc not less than 2.5mm thickness for load bearing section and not less than 2mm thickness for non-load bearing and shall totally dust and vermin proof. Complete VCB panel confirming to IEC 62271-100 & IEC 62271-200 standards and IP 4X class of protection comprising necessary bus-bars extension and connections and following protective and control devices as specified below. Circuit Breaker shall be suitable for E2, M2, C2 duty. Vacuum Interrupters of the circuit breakers shall be completely encapsulated in epoxy housing. The manufacturer of circuit breaker shall also be the manufacturer of the Vacuum Interrupter, Relay. Panels shall be with temperature measurement sensors at all critical points Medium voltage cable connection & Busbar joints/ Connections for local investigation and local monitoring. HMI shall be provided for condition monitoring data and alarms as per Specifications. The switchgear and control gear panels shall be of the fully arc proof for 25kA for 1 Sec., complete with the following accessories:- (A) Relay shall be Microprocessor based Numerical Relay Communicable type in line with IEC 61850 Protocol and RS-485 port comprising of three over current , one earth fault protection relay with high set for both phase & earth and with fault memory equivalent to P3U30 of M/s Schneider or equivalent, universal auxiliary supply, Master Trip Relay, Trip Circuit Supervision relay ,Digital Multifunction meter and RS-485 port with Class 0.5 with copper wound double ratio double core Current Transformer, MFM 0.2 class. Note: Incoming shall be with PT, Transfomer Outgoing shall be Differential relay & Annunciator.
(B) Relay Specifications:- (a) MIMIC display with single line representation and switch gear controls shall be possible through the MIMIC. (b) The device shall support following communication protocols: Native IEC 61850, IEC 60870-5-101, IEC 60870-5-103, Modbus TCP, Modbus RTU, DNP 3.0, SPA-bus communication, (c) Relay shall have front USB for connecting to PC. (d) Relay shall have conformal coating to withstand harsh environment. (e) Relay shall support PRP/RSTP redundancy communication protocol on RJ45/ FO. (f) Relay shall have web server (web HMI) feature to monitor and control using LAN. (g) Relay shall have minimum 2000 events. (h) Relay shall support SNTP time synchronization. (i) Relay shall support customer defined programmable logic. (j) Relay shall have minimum 8 programmable LED. (k) Relay shall have disturbance recorder with settable sample rate from 32/cycle up to 1per minute and shall support virtual simulation through which protection functions and logic testing can be achieved without any separate software. (l) Phase overcurrent (50/51), Directional phase overcurrent (67),SOTF Switch on to fault (50 HS),Current unbalance (46),Thermal overload (49),Earth fault (50N/51N),Directional earth fault (67N), Undervoltage (27),Overvoltage (59), Zero sequence voltage protection (59N), Frequency (81), directional power (32), auto reclose (79), Circuit breaker failure (50BF),Cold load pick-up and magnetizing inrush, Programmable stages (99),Synchro check (25),CB wear. (m) The relay shall have 4CT and 4 VT inputs. (n) The relay shall be provided with at least 16 digital inputs and 8 digital out puts and 1 self-supervision output.
All as per Serial Item No. 57 here in before but for HT 33KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 1600Amp VCBs and 1 NO 1600 Amp Buscoupler with 8 Nos of 1250Amp outgoing VCBs, complete all as specified nd as directed.
All as per Serial Item No. 57 here in before but for HT 11KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 1250Amps VCB and 1 No Buscoupler 1250Amp with 6 Nos 800Amp outgoing VCBs, complete all as specified.
All as per Serial Item No. 57 here in before but for HT 11KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 800Amp VCBs and 1No Buscoupler 800Amp with 4 Nos 630Amp outgoing VCBs, complete all as specified.
All as per Serial Item No. 57 here in before but for 11KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 1250Amp VCBs and 1No Buscoupler 1250Amp with 8 Nos 800Amp outgoing VCBs, complete all as specified.
All as per Serial Item No. 57 here in before but for HT 11KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 800Amp VCBs and 1No Buscoupler 800Amp with 6 Nos 630Amp outgoing VCBs, complete all as specified.
All as per Serial Item No. 57 here in before but for HT 11KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 1250Amp VCBs and 1No Buscoupler 1250Amp with 10 Nos 800Amp outgoing VCBs, complete all as specified.
All as per Serial Item No. 57 here in before but for HT 11KV, 25 kA, Line VCB panels switchboard consisting of 2Nos Incoming 1250 Amps VCB and 1No Buscoupler 1250A with 14 Nos 800 A outgoing VCBs and 2 suitable feeders for 11kV HT DG SET with Bus PT and Bus riser PT, complete all as specified.
Supply, Installation, testing & commissioning of copper wound step down Transformer, Indoor type complete with standard fittings, 3Phase, 7500KVA, 33/11KV Delta/Star "vector group Dyn 11", OLTC Natural Ester Oil cooled transformers, temp rise, Impedance and losses shall conform to IS 1180- level III, radiators shall be Hot dip galvanized (HDG) to avoid corrosion. HV Cable Box and LV Cable Box as per Specifications, with and including with Nitrogen Fire Protection system, Civil Foundation as per OEM recommendations, complete all as specified and as directed. Notes: (i) Pile & Pile Cap for foundation and mounting rails shall be measured and paid separately. (ii) Drawings Shall be Approved by PGCIL. (iii) Foundation shall be as per manufacturers recommendation. (iv) The two winding power transformer shall be nature oil immersed conform to IS-1180, Level-III and IEC-62770 standard for nature ester oil filled transformer. The equipment shall confirming to latest applicable standards as follows: (a) IS:2026 for tests and tolerance on guaranteed particulars. (b) IS: 1180 for Losses and Impedance. (c) IS:3639 for fittings and accessories (d) IS : 2099 for brushing > 1000V (e) IS:7421 for brushing <1000V. (f) IS:1271 for electrical insulation classified by thermal stability.
All as per Serial Item No. 65 here in before but for 12500KVA capacity transformer, complete all as specified.
All as per Serial Item No. 65 here in before but for 20000KVA capacity transformer, complete all as specified.
Design, Supply, Installation, Testing & Commissioning of Nitrogen injection fire protection system and extinguishers for outdoor type transformer 132/11KV of 10/16MVA capacity, confirming to latest IS, complete all as per OEM recommendations, complete all as specified and as directed.
Supply, Installation, testing & commissioning of copper wound step down Transformer, Indoor type complete with standard fittings, 3Phase, 1250KVA, 11/0.433KV OCTC (+7.5% to -7.5%@ 2.5%) Dyn11 Natural Ester Oil cooled Level 3 transformers, temp rise, Impedance and losses shall conform to IS 1180 Level III, radiators shall be Hot dip galvanized (HDG) to avoid corrosion, HV Cable Box and LV Cable Box as per Specifications. with and including Civil Foundation as per OEM recommendations, complete all as specified and as directed. Note: Drawings Shall be Approved by PGCIL.
All as per Serial Item No. 69 here in before but for 3200KVA capacity transformer, complete all as specified.
All as per Serial Item No. 69 here in before but for 2000KVA capacity transformer, complete all as specified.
All as per Serial Item No. 69 here in before but for 1000KVA capacity transformer, complete all as specified.
All as per Serial Item No. 69 here in before but for 800KVA capacity transformer, complete all as specified.
All as per Serial Item No. 69 here in before but for 500KVA capacity transformer, complete all as specified.
All as per Serial Item No. 69 here in before but for 250KVA capacity transformer, complete all as specified.
All as per Serial Item No. 69 here in before but for 100KVA capacity transformer, complete all as specified.
Supply, Installation, testing & commissioning of Power transformer step down outdoor type 132/33 KV, 40/50 MVA KNAN/KNAF, Natural Ester Oil Cooled as per IEC 62770, Vector group Delta/Star (Dyn11) with on load tap changing gear + 5% to -15% in steps of 1.25% on HV side, with terminal arrangement of HV Cable Box /LV Cable Box and all standard accessories as per IS 1180 Level II and as specified in PS, including first fill of oil, radiators shall be Hot dip galvanized (HDG) to avoid corrosion with and including with Nitrogen Fire Protection system, Civil Foundation as per OEM recommendations, complete all as specified and as directed. Note: Drawings Shall be Approved by PGCIL.
Supply, Installation, testing & commissioning of copper wound step down Transformer, outdoor type trolley mounted, complete with standard fittings, 3Phase, 500KVA, 11/0.433KV OCTC (+7.5% to -7.5%@ 2.5%) Dyn11 Natural Ester Oil cooled Level 3 transformers, temp rise, Impedance and losses shall conform to IS 1180 Level III, radiators shall be Hot dip galvanized (HDG) to avoid corrosion, HV Cable Box and LV Cable Box as per Specifications, including trolley required as per OEM recommendations, complete all as specified and as directed.
Supply, Installation, testing & commissioning SF6 Gas Circuit breaker for 145KV, 1600Amp for outdoor yard to be installed at the incommer of APTRANSCO 132kV line, with and including necessary conncetions with ACSR conductor/ clamps etc., to the existing double bus bar connected to the booms at site, including the civil works for foundation and any other accessories to make the circuit breaker functional with the existing system, complete all as specified and as directed.
Supply, Installation, testing & commissioning of Silent Diesel Engine driven generating set, prime mover with electronic governing 415Volt (at 0.8 PF) 200KVA, 3 phase, 50 Hz, 1500RPM with acrostic enclosure and canopy type (indoor use) made out of min 14 gauge CRCA sheet with AMF Panel with and including all excavation, PCC foundation (as per manufacturers recommendation's), anti vibration pads, tamper standard control panel as per manufacture instructions, The DG set will comprise of following: - (a) Alternator: Standard design alternator rated at 200KVA net out put at site, self excited, self regulated through an AVR, screen protected, revolving field, brushless design with permanent lubricated bearings with winding in each pole, insulation class H, voltage regulation ± 1.5 % of rated voltage 'No load to full load'. The alternator shall be in a position to generate supply with frequency regulation within ± 1 % tolerance and permissible overload of 10 % for one hour in 12 hrs continuous run and conforming to IS 13364 with latest amendments. (b) Diesel Engine adequate capacity suitable for 200 KVA Alternator water cooled to dirve indpependently the above alternator directly coupled through flexble coupling multi cylinder Multi stroke direct injection cold strating 1500RPM as per revant IS, IS:10001/ 10002 BS 5514 with in overload capacity of 12 hrs continious running, with standard accessories all as specified and required for site handling and operation, the scope of accessories shall be as under :- (i) Air intake system : air intake manifold air cleaner. (ii) Exhaust system : Turbo charger SS Flexible below silencer complete with MS exhaust piping of suitable size upto and outside the building covered with glass wool covered under aluminium foil of 28 gauge, adequate to exhaust without transferring vibration to building/walls as per latest CPCB Norms. (iii) Coolant system : Engine water pump, radiator with fan and fan belt. (iv) Lubricting system Oil pump of suitable capacity, lub oil pump and lub oil filter. (v) Fuel system : Fuel injection pump 12/24 Volts (as per OEM recommendation) DC solonoid switch nozzle mechanical/electronic governor, replaceable fuel filter, fuel tank made of 14 SWG sheet with drain valve, air vent inlet and outlet connection, fuel supply piping from tank to pump & to engine including return of over flow fuel with level indicating arrangement duly marked in inches/Litres. Fuel tank should be of adequate capacity for 8 hrs running at full load.
All as per Serial Item No. 80 here in before but for 160KVA capacity DG Set with alternator at 160KVA net output at site and capacity of diesel engine shall be adequate for 160KVA alternator, complete all as specified.
All as per Serial Item No. 80 here in before but for 250KVA capacity DG Set with alternator at 250KVA net output at site and capacity of diesel engine shall be adequate for 250KVA alternator, complete all as specified.
All as per Serial Item No. 80 here in before but for 100KVA capacity DG Set with alternator at 100KVA net output at site and capacity of diesel engine shall be adequate for 100KVA alternator, complete all as specified.
All as per Serial Item No. 80 here in before but for 500KVA capacity DG Set with alternator at 500KVA net output at site and capacity of diesel engine shall be adequate for 500KVA alternator, complete all as specified.
All as per Serial Item No. 80 here in before but for 750KVA capacity DG Set with alternator at 750KVA net output at site and capacity of diesel engine shall be adequate for 750KVA alternator, complete all as specified.
All as per Serial Item No. 80 here in before but for Outdoor type Trolley mounted 500KVA capacity DG Set with alternator at 500KVA net output at site and capacity of diesel engine shall be adequate for 500KVA alternator, with and including trolley as per manufacturer's instructions, complete all as specified.
S&F Fully automatic transfer Change over switch with RJ 45 ethernet connect port along with cable integrated with SCADA for source change, cubical type with arc chute of capacity 160 Amps, range 63A to 160A, AC 23A, 4P conforms to latest IS/IEC codes with inter chargeable dual shaft position with site convertibility and flip-able handle able 160A capacity in LT panel, including necessary interconnections of cables and control wiring, complete all as specified and as directed.
All as per Serial Item No. 87 here in before but of capacity 315 Amps.
All as per Serial Item No. 87 here in before but of capacity 400 Amps.
All as per Serial Item No. 87 here in before but of capacity 500 Amps.
All as per Serial Item No. 87 here in before but of capacity 630 Amps.
All as per Serial Item No. 87 here in before but of capacity 800 Amps.
All as per Serial Item No. 87 here in before but of capacity 1250 Amps.
Supply, Installation, testing & commissioning of indoor type, metal enclosed corrosion proof aluminium alloy gas insulated switchgear 145 KV 3Ø 50 HZ, 2500 Amps, 3 phase encapsulated consisting of two Nos transformer bays on existing double bus bar system, including installation tools, spares, refill kits with and including following items along with GIS system:- a) Local control cubicles b) Gas handling equipment for draining and refilling of each compartment of GIS including filtration and purification equipment and vacuum pump. c) SF6 gas sufficient for first filling of entire switch gear including usual losses during commissioning. d) 2 Bottles (40 Kg each) of SF6 gas in non returnable vessels. e) Gas leakage detectors. f) Gas Purity Tester for air content and moisture content in SF6 gas. g) Special tool and tackles for erection operation and maintenance of GIS. h) Mandatory spares and tools. Note:- The GIS system offered by the contractor shall be designed, manufactured, assembled and tested in accordance with the IEC 62271-203 for switch gear and other relevant IEC.
Item No.95 Contd/- (a) Windows based Application Server, Server with minimum 8 GB RAM, minimum 512 GB HDD, 36/72 GB Cartridge magnetic tape drive, DVD-R Drive, GPS Time Synchronization card & all interface cables along with one keyboard & one mouse and speakers, 10/100/1000 USB ports, ports for connecting to cartridge Magnetic Tape-2 sets (Connected in Main & hot standby mode) (b) Dual 21” TFT Colour monitor (1280x1024 resolutions)-2 Nos. workstation console WITH Two 21” TFT Monitors Window based PC with minimum 8 GB RAM, minimum 512 GB Auxiliary memories, DVD-RW drive all interface cable along with one keyboard & one mouse and speakers, 10/100/1000, USB ports, ports for connecting cartridge Magnetic Tape-2 Nos. Engineering console Window based PC with minimum 8 GB RAM, minimum 512 GB HDD, DVD-RW drive all interface cable along with one keyboard & one mouse and sperakers, 10/100/1000, USB ports, ports for connecting cartridge Magnetic Tape-2 Nos. DPR Black & White laser printer (1200 dpi, A4, 10 ppm both colour and black & white, one Enthernet port) – 1 NO LCD screen size 52” – 1 No LAPTOP for maintenance – 01 No.
Workstation console for LDMS Windows based PC with minimum 8 GB RAM, minimum 512 GB HDD, DVD-RW drive all interface cable along with one keyboard & one mouse and speakers, 10/100/1000, USB ports, ports for connecting cartridge Magnetic Tape-4 Nos. 10/100/1000 Mbps Ethernet L2 Switch for single LAN (24 ports) -04 Nos. Black & White Laser printer (1200 dpi ,A4,10 ppm both colour and Black & White)- 04 Nos. Fiber Optic Transmission Equipment as per specification - 05 Nos. Bay Control Unit: BCU 132/33/11 KV – independent unit and compactible with future BCU s for 10 UCs 33kV /11Kv s/s (i) Should have GPS with Antena and Display (time) Note- BCU for 10 Distribution 33kV &11 KV SS not in scope Software: SCADA /MMI/ISR/SNMP based NMS software for redundant system- 1 lot, Web browser client license/ client software -5 Nos. Software tools for development of SCADA Database, display, reports - -1 lot Development of SCADA Database, Display, Reports Generation and RTU database – 1 lot, LDMS software -4 lots BCU Test Tools: Data Base Configuration & Generation software tool-1 lot Master station-cum-BCU simulator & protocol analyser software tool-1 lot Laptop for above software tools along with interface cables & connectors -1 set (Note- All required items deemed included as per requirement per independent unit 33/11 KV /0.433KV for substation: Training: 2-week training on SCADA at site by OEM.
All as per Serial Item No. 96 here in before but for for Bus coupler for back up protection for 132 KV, complete all as specified.
Design, Supply Install test and commissioning of 33 KV Capacitor bank out door type internally fused double star connected including necessary bus bar of capacity 3600 KVAR and 0.2% reactors NCT, LA consisting of 5 Nos Banks (200KVAR, 400KVAR, 600KVAR, 1200KVAR-02Nos) with individual capacitor unit, including civil foundation as per OEM instructions, complete all as specified.
Design, Supply, Install, Test and commissioning of Automatic Power Factor Control panel suitable for 3600 KVAR 33 KV including VCB, APFC relay, Isolator including necessary CTs,HT cable and any other acceas per site conditions for connecting to the 33kv HT VCB panels, complete all as specified and directed.
Supply, Installing, testing and commissioning of OEM factory made, totally type tested panel confirming to IEC 61439 Part-1 & 2(IEC Type tested panel & Switch gear) confirming to IP 54 Protection, Free standing mounted on PCC pedestal, dust and vermin proof LT cubical panel board, compartmentalised, Indoor type, fabricated with 2.00mm thick CRCA sheet and shall be given pre-treatment for degreasing, phosphatising etc. In seven tank process and shall be powder coated with RAL7035 coat with matt finish after due preparation of surfaces. The panel shall consist of high conductivity Aluminium Alloy bus bar TPN of rating 1.5times the incoming switchgear Amps capacity and shall be provided with colour coded heat shrinkable sleeves mounted on porcelain insulator supports, suitable double compression aluminium cable glands and panel shall be provided with separate compartments for each switch, with gland plates lifting hooks, shutter type ventilating louver at top & bottom duly internally secured with wire mesh, suitable size, including instrumentation such as digital Ampere meter, digital Volt meter, Phase indicating lamps [RYB] etc with double stud hinged door, Operating handle & locking arrangement with back door common openable(screwed/Lockable) including interlocking with switch gears and suitable for 1100 volts Grade, 3 phase 4 wire with rated operational voltage 433V,50Hz, AC supply and to with stand short circuit fault level of not less than 100KA, rated insulation voltage of 1000V and Impulse withstand of 12kV and minimum internal Arc with-stand of 65kA, 500mSec as per IEC61641, weather proof. The panel shall be fixed with angle iron frame 50x50x6mm at corners and ISMC of suitable size base fixing PCC 1:2:4 type B1 for the pedestal and foundation as per the OEM recommendation and connecting of incoming/outgoing cable etc., complete with and including M&L for following accessories:- Note: Drawing shall be approved by PGCIL, All Incoming MCCBs are of Microprocessor based and out going MCCBs are of Adjustable type.
BLANK
M&L for Cutting & Chipping of laitance concrete in piles above cut off level upto a maximum of 1m from cut of level and disposal to distance of exc. 50m but n. exc. 250m and depositing where directed by Engineer-in-Charge.
M&L for Drilling or boring for 600mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
All as per Serial Item No. 167 here in before but for 600mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified.
M&L for Drilling or boring for 750mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
All as per Serial Item No. 169 here in before but for 750mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified.
M&L for Drilling or boring for 1000mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
All as per Serial Item No. 171 here in before but for 1000mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified.
M&L for Drilling or boring for 800mm nominal dia. bored cast-in-situ piles through any or all types of strata i.e soft/loose soil, stiff clay, gravel, cobble stone, compact moorum, soft conglomerate or loose boulders, disintegrated rock, weathered rocks etc., (except hard rock for socketing depth) upto top of socketing depth/founding depth by adopting suitable method with perennial water and disposal of drilling/bored materials outside MD land as directed, complete all as specified and as directed.
All as per Serial Item No. 173 here in before but for 800mm nominal dia through hard rock for founding depth minimum 2D (Where D is dia of pile), complete all as specified. Notes for Item Nos. 167 to 174:- (i) The depth of boring for piles shall be measured from existing ground level to the approved founding level. (ii) It shall be ensured that the waste bentonite slurry/ drilled or bored material is pumped off from the premises to locations shown by GE to contractor at his own cost. (iii) All channels/tanks made for bentonite circulations shall be filled with approved moorum obtained by contractor at his cost after clearing all bentonite cakes. (iv) The contractor may use any approved method as approved by GE for boring without any extra cost to the Govt. The rates for boring of piles shall be inclusive of any method/ casing that may be used by the contractor for bored piles. Nothing extra shall be paid. (v) For the purpose of payment of boring/drilling, description of hard rock shall be as given in SSR Part-I specification. (vi) The rate quoted by the contractor shall be inclusive of the rates for the shifting and setting up of piling rig as many times as required.
Carrying out initial load tests on test pile of 600mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for 2.5 times of the design load in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile) depth, complete all as specified. Note: Load rquired for testing as per IS shall be arranged by the contractor and test pile shall be abondoned after testing.
Carrying out initial load tests on test pile of 750mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for 2.5 times of the design load in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile) depth, complete all as specified. Note: Load rquired for testing as per IS shall be arranged by the contractor and test pile shall be abondoned after testing.
Carrying out initial load tests on test pile of 800mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for 2.5 times of the design load in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile) depth, complete all as specified. Note: Load rquired for testing as per IS shall be arranged by the contractor and test pile shall be abondoned after testing.
Carrying out initial load tests on test pile of 1000mm dia as per standard procedure laid down in IS-2911 by static load test method with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc. as specified and as directed by GE and submission of reports for 2.5 times of the design load in non-working areas in the vicinity of site, including the cost of new piles with specification as same as working pile with minimum depth of socketing into the hard rock 2D (Where D is dia of pile) depth, complete all as specified. Note: Load rquired for testing as per IS shall be arranged by the contractor and test pile shall be abondoned after testing.
Carrying out routine load test on 600mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 1.5 times of the design load, complete all as specified and as directed.
Carrying out routine load test on 750mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 1.5 times of the design load, complete all as specified and as directed.
Carrying out routine load test on 800mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 1.5 times of the design load, complete all as specified and as directed.
Carrying out routine load test on 1000mm dia pile (working pile) as per standard procedure given in IS-2911 (Part IV) by high strain dynamic load with compressive strength, including construction of test cap, dismantling the cap after the test and clearing the site and maintaining complete records of load settlements etc and submission of reports for 1.5 times of the design load, complete all as specified and as directed.
SALASAR TECHNO ENGINEERING LIMITED
SLC PROJECTS Pvt Ltd
Vijay Nirman Company Pvt Ltd
GUPTA POWER INFRASTRUCTURE LIMITED
Sterling and Wilson Pvt. Ltd
NCC LIMITED
Sri Gopikrishna Infrastructure Private ltd
stage.html
html • 0.06 MB
tech_eval.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf