Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹8.9 LAccepted-AOC V P O MILLAH TEHSIL SHILLAI DISTT SIRMOUR 173029 | SIRMAUR | HIMACHAL PRADESH | 173029 | ₹8.9 L Quoted ₹9.0 L | L1 | Accepted-AOC AOC |
| 2 | L2₹9.6 L+₹59,160 (6.58%)Rejected-Finance NOT AVAILABLE | FARIDABAD | HARYANA | 121004 | ₹9.6 L+₹59,160 (6.58%) | L2 | Rejected-Finance Second lowest bidder |
Tender Value
₹7.5 L
EMD Value
₹15,000
Closing Date
24 Aug 2022, 5:00 pmClosed
Executive Engineer
HPSIDC Shimla
Providing Electrical Installation
2022_SIDC_63658_1
Job No. 5
Open Tender
Electrical Works
Item Rate
90 days
Nahan
Please refer Tender documents.
9 documents required · 9 mandatory
₹900
₹15,000
22 Sept 2022
17 Aug 2022
25 Aug 2022
17 Aug 2022
24 Aug 2022
17 Aug 2022
Amount
Wiring for light point / fan point / exhaust fan / call bell point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group C.
Wiring for twin control light point with 1.5 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit with 2-way, 5/6 amps. modular switch, modular plates, suitable G.I. box and earthing the light point with 1.5 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable as required. Group B.
Wiring for circuit/sub-main with following size PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 1 No.HRFRLS/PVC insulated single core copper conductor cable of same size for earthing as required. (i) 2x1.5 Sq. mm.
(ii) 2x2.5 Sq. mm.
(iii) 2x4.0 Sq. mm.
(iv) 2x10 Sq. mm.
Wiring for power plug with 4x4 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed steel conduit along with 2 No.4 Sq.mm. HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Wiring for circuit / sub-main with 4x10 Sq. mm. PVC insulated heat resistant flame retardant (HRFR) and low smoke single core (flexible) copper conductor cable in surface/recessed PVC conduit along with 2 No.10 Sq.mm. (4x10+2x10) HRFRLS/PVC insulated single core copper conductor cable for earthing as required.
Supplying and fixing following rating Modular switch /socket in the existing switch box / cover plate including connections etc. as required. (i) S.P. 5/ 6 Amps one way Modular switch.
5 pin, 5/ 6 Amps Modular socket outlet.
Supplying and fixing stepped type Modular fan regulator on the existing modular box including making connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 5 pin 5/6 amps modular socket outlet and 5/6 amps, modular switch, connections etc. as required.
Supplying and fixing G.I. Modular box of (140mmx78mmx50mm) size with modular plate and cover in recess including providing and fixing 6 pin 15/16 amps modular socket outlet and 15/16 amps, modular switch, connections etc. as required.
Supplying and erection of 6 amps. to 32 amps. rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Single pole. Cat-A.
Supplying and erection of 40/50/63 amps rating, 10 KA breaking capacity, 240 volts, 'C' curves, miniature circuit breaker of following poles in the existing MCB DB complete with connections etc. as required:- Double pole. Cat-A.
Supplying and fixing following rating, four pole, 415 volts, Isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and fixing following rating, four pole (three phase & neutral) 415 volts, residual current circuit breaker (RCCB), having a sensitivity current up to 300 miliampers in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63 Amps. Cat-A.
Supplying and fixing of following way, single pole and neutral sheet steel MCB distribution board, 240 volts, on surface / recess, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, blanking plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Double door-12 way
Supplying and fixing of following way triple pole and neutral, sheet steel MCB distribution board, 415 volts, on surface / recess, with provision for 4-pole MCB/Isolator/RCCB/RCBO as incomer and SP MCBs as outgoing, complete with tinned copper bus- bar, wire-set, neutral link, earth bar, din-bar, detachable gland plate, cable, identification labels interconnections, phosphatized and powder painted, including earthing etc. as required:- Single door-8 way (8+24), horizontal type
Earthing with G.I earth pipe 4.5 mtr. long and 40mm dia, including accessories and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. ( but without charcoal or coke and salt ) complete as required.
Extra for using salt and charcoal for pipe earth electrode complete as required.
Providing and fixing 6 SWG (4 mm dia.) G.I. wire on surface or in recess for loop earthing as required.
Providing and laying of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade direct in ground; to be laid 1 meter below the ground level including excavation sand cushioning, protective covering and refilling the trench etc. of the required size:- Armoured cable 16 sq. mm (four core)
Providing, laying and fixing of one No. aluminium conductor, PVC insulated and PVC sheathed, armoured/XLPE power cable, working voltage 1100 volts grade on surface etc. of the required size:- Armoured cable 16 sq. mm (four core)
Providing, Installation, testing and commissioning of ceiling fan with regulator, including wiring the down rods of standard length (up to 30 cm) with 16/0.20 mm twin twisted flexible, cotton braided, copper cable, including providing and fixing phenolic laminated sheet cover on the fan box and earthing etc. as required:- Ceiling Fan 1200 mm sweep, Category-A
Providing and installation of exhaust fan of following sizes in the existing opening, including making the hole to suit the size of the above fan, making good the damages, connections, testing and commissioning etc. as required:- Exhaust Fan, heavy duty, 300 mm sweep
Providing & fixing surface/ recess mounted 15W LED panel of Syska/Havells/Philips/ Bajaj make as required complete in all respect equivalent to Bajaj CAT No.BGSLO Sleek Surface 15W WHSQ
Providing & fixing LED Batten aluminium body integrated LED channel of Bajaj make having Bajaj/ Havells / Philips make as below:(i) Batten/LED integrated channel fitting 10W
Batten/LED integrated channel fitting 20W
Providing & fixing surface/ recess mounted 9W LED panel of Syska/Havells/Philips/ Bajaj make as required complete in all respect equivalent to Bajaj CAT No.BGSLO Sleek Surface 9W WHSQ
Providing & fixing BLAZE LED Highway Luminaire equivalent to Bajaj CAT No. BGHBM 80W LED XE complete with fixing arrangement as approved & directed by engineer in charge.
Providing & fixing 45 Watt Street/Flood light fitting with suitable GI pipe bracket equivqlent to Bajaj/ Havells/ Philips/ Syska as per CAT No. BRTFG 36W LED V2 complete in all respect .
Providing & fixing surface/ recess mounted 24W LED panel of Syska/Havells/Philips/ Bajaj make as required complete in all respect equivalent to Bajaj CAT No.CS 24/1*1 of C& S
Providing & Fixing outdoor wall spotlight of Changi/ Syska/ Decon make LED 2*5 watt CH-015-2*5W both side as per item code No.668 complete in all respect to the best satisfaction of engineer in charge. including connection extra as required complete in all respect.
P/F shutter suitable for heavyv duty exhaust fan as approved & directed by Engineer_In-Charge.
P/F CO2 fire extinguisher 4.5 Kg confirming to IS complete with hooks as approved & directed by Engineer_In-Charge.
P/F water CO2 fire extinguisher 9 Kg confirming to IS complete with hooks as approved & directed by Engineer_In-Charge.
Yog Raj
stage.html
html • 0.04 MB
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Tap a document below to read it instantly. You can also download everything as a ZIP if you prefer.
details.html
html • 0.04 MB
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .