Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹1.7 LAccepted-AOC ATAL CHOWK CHANWARIDAND MANENDRAGARH KOREA CHHATTISGARH | KOREA | CHHATTISGARH | 497442 | ₹1.7 L | L1 | Accepted-AOC As being L1 and qualifies eligibility criteria |
| 2 | Rejected-Technical NEAR CSP OFFICE REGIONAL COLONY GODRIPARA CHIRIMIRI DISTT MCB C G 497555 | KOREA | CHHATTISGARH | 497555 | - | - | Rejected-Technical Not taken for technical evaluation as not being L1 |
| 3 | Rejected-Technical GHUTRI DAFAI HALDIBADI CHIRIMIRI DISTT KOREA C G 497451 | KOREA | CHHATTISGARH | 497451 | - | - | Rejected-Technical Not taken for technical evaluation as not being L1 |
Tender Value
₹3.7 L
EMD Value
₹4,700
Closing Date
24 May 2024, 5:00 pmClosed
Staff Officer (EnM), Chirimiri Area
Office of the General Manager, SECL Chirimiri Area , P.O. West Chirimiri Distt. MCB (C.G.) 497773
A) Diversion/erection of 3.3kV Overhead Line for UG pump from turra pond to mine substation at Kurasia Colliery. B) Extension of 3.3kV OHL from 6 no. feeder up to new 5 no. bore hole site over seam-V at Kurasia Colliery.
2024_SECL_308049_1
SECL/GM/CHRM/EM/e-Tender/ 24-25/07 dtd. 13.05.2024
Open Tender
Electrical and Maintenance Works
Item Rate
30 days
Kurasia Colliery, Chirimiri Area
As per NIT
5 documents required · 5 mandatory
₹4,700
4 Sept 2024
13 May 2024
25 May 2024
13 May 2024
24 May 2024
14 May 2024
14 May 2024 - 21 May 2024
Amount
Diversion/erection of 3.3kV Overhead Line for UG pump from turra pond to mine substation at Kurasia Colliery
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 10.00 metre and upto 12.00 metre
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 4.00 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of all aluminium conductor of 7/1.96 mm to 7/3.10 mm diameter including binding etc. as required.
Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Erection of disc/ pin insulator for 11 KV over head lines as required.
Extension of 3.3kV OHL from 6 no. feeder up to new 5 no. bore hole site over seam-V at Kurasia Colliery
Erection of RCC/ PCC pole of following length in brick ballast and ramming the foundation, finishing with 150mm thick cement concrete (1:3:6) layer on top with including excavation and refilling etc as required. Above 10.00 metre and upto 12.00 metre
Supplying and erection of stay set complete (galvanised) with 19/20 mm dia X 1.8 metres long stay rod, anchor plate of size 45 cm X 45 cm X 7.5 mm, thimble, stay clamps, turn buckle ( 20 mm X 60 cm ), 7/ 3.15 mm dia G.I. stay wire and strain insulator etc in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40 mm nominal size ) foundation including excavation and refilling etc. as required.
Erection of ACSR conductor of 7/3.35 mm to 7/4.00 diameter and above including binding etc. as required.
Erection of G.I. Wire No. 8 SWG including binding etc. as required.
Supplying of two lengths of channel iron 75 mm X 40 mm X 6 mm (7.14 kg per metre) double pole cross arm for three wire 11KV over head line conductors complete with through bolts and nuts for clamping to the poles, 50 mm X 6 mm M.S. flats welded on one side to the channel iron and with bolts and nuts on the other side for tying the cross arms together, including drilling holes for insulator pins/ fittings, bolts, nuts and washers etc (as per drawing) and painting with primer and finish paint as required.
Erection of double pole 3 wire cross arm for 11KV/ 22KV/ 33 KV over head lines as required.
Supplying and erection of 11 KV pin insulator complete with large steel head G.I. pin, nuts, washers etc. as required.
Supplying and erection of 11 KV disc insulator for 11 KV over head lines with galvanised insulator fittings, ball and socket type and complete with galvanised strain clamps, bolts, nuts, washers etc. as required.
Total impact of GST for the purpose of CTC
DEVENDRA TEWARI
JAI MAA KALI ENTERPRISES
tech_eval.pdf
fin_eval.pdf
aoc.pdf
finance_319201.pdf
boq_comp_chart.xlsx
xlsx
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .