Loading…
Loading…
| # | Company | Amount | Rank | Status |
|---|---|---|---|---|
| 1 | L1₹15.5 LAccepted-AOC 17 1 ABHOY HALDER LANE KOLKATA | KOLKATA | L1 | Accepted-AOC lowest | |
| 2 | L2₹15.6 L+₹8,502.30 (0.55%)Rejected-Finance 1 1A VANSITART ROW 2ND FLOOR ROOM NO 2 KOL 700 001 | KOLKATA | KOLKATA | WEST BENGAL | 700001 | L2 | Rejected-Finance 2nd lowest | |
| 3 | L3₹15.7 L+₹15,951.05 (1.03%)Rejected-Finance 138 CANNING STREET GROUND FLOOR KOLKATA | KOLKATA | WEST BENGAL | L3 | Rejected-Finance 3rd lowest |
Tender Value
Refer Docs
EMD Value
₹32,000
Closing Date
27 Sept 2024, 11:00 amClosed
The Executive Engineer, PMD,PHE.Dte
Office of the Executive Engineer Purulia Mechanical Division,PHE.Dte Ranchi Road,Purulia.
Supply delivery and installation of MS pipe, specials including supply and laying of different size cables including allied works at WTP site under Augmentation of Balarampur Water supply scheme under Purulia Mechanical Division, PHE Dte. in the Dist
2024_PHED_740767_19
07 /EE/PMD/PHED OF 2024-2025
Open Tender
MECHANICAL
Item Rate
60 days
Purulia
Please refer Tender documents.
6 documents required · 6 mandatory
₹32,000
Yes
24 Jan 2025
2 Sept 2024
30 Sept 2024
2 Sept 2024
27 Sept 2024
2 Sept 2024
Amount
Supply delivery of following MS pipes :- a) 125 mm dia of 8 mm thickness
b) 150 mm dia of 8 mm thickness
c) 200 mm dia of 8 mm thickness
d) 250 mm dia of 8 mm thickness
Supply and delivery of 1.1 KV Grade , XLPE insulated Al. Ar. Cable as per IS-7098(Part-I) following cables at site :- a) 400 sq mm 3.5 core Al. Ar. Cable.(For substation to MCC Panel). Make-As per PHED Approved vendor List
b) 70 sq mm 3 core Al. Ar. Cable (for Zone-I Pump and motors).Make-As per PHED Approved vendor List
c) 35 sq mm 3 core Al. Ar. Cable (for Zone-II pump and motors). Make-As per PHED Approved vendor List
d) 25 sq mm 3 core Al. Ar. Cable (for Zone-II pump and motors).Make-As per PHED Approved vendor List
d) 4 sq mm 4 core Al. Ar. Cable . Make-As per PHED Approved vendor List
e) 1.5 sq mm 10 core copper Cable . Make-As per PHED Approved vendor List
f) 95 sq mm 3.5 core Al. Ar. Cable (for substation to intake site).Make-As per PHED Approved vendor List
Laying the above supplied cable by cable tray and also hanging the cable tray by tie rod inside the pump house by expert electrician from and to basis complete the job. a)400 sq mm 3.5 core Al. Ar. Cable.(For substation to MCC Panel).
b) 70 sq mm 3 core Al. Ar. Cable (for Zone-I Pump and motors).
c) 35 sq mm 3 core Al. Ar. Cable (for Zone-II pump and motors).
d) 25 sq mm 3 core Al. Ar. Cable (for Zone-II pump and motors).
e) 4 sq mm 4 core Al. Ar. Cable .
f) 1.5 sq mm 10 core copper Cable.
Laying of one No. cable of 95 sqmm in underground trench 460mm wide x 760mm average depth, with brick protection on the top of the cable with 8 (eight) Nos. bricks per Mtr. including filling the space between the bricks and cable and also the trenchwith shifted soil, leveling up and restoring surface duly rammed.
Supply and delivery at site 2 mm thick CRCA enclosed IP-54 LPBS for pump motor set (Make : PHED Approved Make)
Supply and delivery 250 mm X 300 mm reducer for header line.
Supply, delivery and storage at site of following dia. MS Dismantling joints with Rubber compression Ring and adjustable follower flanged complete assembled unit with galvanized stud and nuts. a)DN-150 mm, PN-1.0 (At Suction side of the Zone-I Pump)
b) DN-200 mm, PN-1.0 (At Suction side of the Zone-II Pump)
c) DN-200 mm, PN-1.0 (At Suction side of the Backwash Pump)
d) DN-125 mm, PN-1.6 (At Delivery side of the Zone-I Pump)
e) DN-150 mm, PN-1.6 (At Delivery side of the Zone-II Pump)
f) DN-150 mm, PN-1.0 (At Delivery side of the Backwash Pump)
Supply and delivery at site alluminium extension ladder for pump house requirement.
Fitting fixing the above new supplied item (Sl. No.1 & 5 to 7.06) with supply of fixing materials by expert mechanic and also manual labour complete the job as per direction of EIC.
Supply and delivery of following puddle pipes :- a)200 mm Size, 600 mm length for suction line
b) 150 mm Size, 600 mm length for suction line
Add GST @ 18%
Add CESS @ 1%
ALOK ENTERPRISE. A Unit of Saket Trexim Pvt. Ltd. (BID ID -5540941)
WEST BENGAL ENGINEERING CO. (BID ID -5538008)
tech_bid_open.pdf
tech_eval.pdf
fin_bid_open.pdf
boq_comp_chart.xlsx
xlsx
fin_eval.pdf
aoc.pdf
Download all tender documents and submit your bid
Disclaimer: TenderKart has made every reasonable effort to ensure that the information on this page is accurate and authentic, however it cannot be held liable for any third-party claims or losses or any damages. TenderKart makes no warranty, expressed or implied, as to the results obtained from the use of this information. If you notice any error or omission, please let us know at .